• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Stabilisation et positionnement actifs précis de modules mécaniques

Le Breton, Ronan 05 July 2013 (has links) (PDF)
Cette thèse s'inscrit dans le cadre de l'étude de la stabilisation de modules d'un futur collisionneur linéaire, CLIC (Compact Linear Collider). Afin d'assurer le fonctionnement et la collision des particules dans ce futur grand instrument de physique, il faut garantir l'alignement de modules guidant des faisceaux de dimensions nanométriques. Les travaux développés ont pour support expérimental deux dispositifs : un dispositif de micropositionnement, avec une résolution inférieur au 1µm, où les perturbations peuvent être simulées et un prototype de nanostabilisation active pour charges importantes (>50kg @300Hz), avec une résolution validée expérimentalement inférieur à 0,15 nm, permettant de démontrer la faisabilité du contrôle de la stabilisation subnanométrique en s'intéressant particulièrement au rejet des mouvements du sol. Les problématiques traitées lors de ces travaux portent sur la méthodologie de conception de tels systèmes, ce qui inclue la conception électromécanique et l'instrumentation, ; la mise en œuvre et la modélisation du comportement des prototypes ,; le contrôle avec notamment les aspects de non linéarité des actionneurs. Les performances obtenues de ces différents travaux et validées expérimentalement incluent notamment les points suivants: La bande passante de fonctionnement pour du micro-positionnement à l'aide d'actionneurs piézoélectriques a été augmentée grâce à la compensation d'hystérésis : Rejet de perturbation issue du support jusqu'à 100 Hz et positionnement jusqu'à 190 Hz. Il a été démontré la faisabilité du contrôle à l'aide de capteurs sismiques. L'isolation active réalisée présente une atténuation des nano-mouvement du sol dans une bande passante comprise entre 12 et 100Hz. Expérimentalement, cela conduit à une réduction des mouvements du sol de 0,6nm [rms] à 0,25nm [rms] à 50Hz et de 3,7nm [rms] à 0,9nm [rms] à 20Hz.
2

Stabilisation et positionnement actifs précis de modules mécaniques / Precise active positioning and stabilization of mechanical modules

Le Breton, Ronan 05 July 2013 (has links)
Cette thèse s'inscrit dans le cadre de l'étude de la stabilisation de modules d'un futur collisionneur linéaire, CLIC (Compact Linear Collider). Afin d'assurer le fonctionnement et la collision des particules dans ce futur grand instrument de physique, il faut garantir l'alignement de modules guidant des faisceaux de dimensions nanométriques. Les travaux développés ont pour support expérimental deux dispositifs : un dispositif de micropositionnement, avec une résolution inférieur au 1µm, où les perturbations peuvent être simulées et un prototype de nanostabilisation active pour charges importantes (>50kg @300Hz), avec une résolution validée expérimentalement inférieur à 0,15 nm, permettant de démontrer la faisabilité du contrôle de la stabilisation subnanométrique en s'intéressant particulièrement au rejet des mouvements du sol. Les problématiques traitées lors de ces travaux portent sur la méthodologie de conception de tels systèmes, ce qui inclue la conception électromécanique et l'instrumentation, ; la mise en œuvre et la modélisation du comportement des prototypes ,; le contrôle avec notamment les aspects de non linéarité des actionneurs. Les performances obtenues de ces différents travaux et validées expérimentalement incluent notamment les points suivants: La bande passante de fonctionnement pour du micro-positionnement à l'aide d'actionneurs piézoélectriques a été augmentée grâce à la compensation d'hystérésis : Rejet de perturbation issue du support jusqu'à 100 Hz et positionnement jusqu'à 190 Hz. Il a été démontré la faisabilité du contrôle à l'aide de capteurs sismiques. L'isolation active réalisée présente une atténuation des nano-mouvement du sol dans une bande passante comprise entre 12 et 100Hz. Expérimentalement, cela conduit à une réduction des mouvements du sol de 0,6nm [rms] à 0,25nm [rms] à 50Hz et de 3,7nm [rms] à 0,9nm [rms] à 20Hz. / This thesis takes place in the framework of a general study about the stabilization of the mechanical modules of a future linear collider, CLIC (Compact Linear Collider). In order to guarantee the good operation and the particle collision, the nanometer sized beams need to be stabilized. The proposed approach was developed on two mock-ups: one dedicated to micropositioning with disturbances generation capabilities, and an active isolation system operating heavy load (up to 50kg at 300Hz) at the nanometer scale with an experimentally validated resolution of 0.15 nm. This work studies the electromechanical design and the instrumentation, the implementation of the two set-ups and their modeling,; the control scheme that takes into account the nonlinearities of the actuators. The experimental achievements include the increase of the bandwidth for piezoelectric micro-positioning thanks to an inverse hysteresis operator: the perturbation rejection is efficient until 100 Hz and the tracking control until 190 Hz. A control scheme using seismic sensors is developed to attenuate ground motion and to isolate a platform in a 12 Hz to 100 Hz frequency range. The experimental displacement is reduced from 0.6 nm to 0.25 nm at 50 Hz and from 3.7 to 0.9 at 20 Hz.
3

Etude des vibrations et de la stabilisation à l'échelle sous-nanométrique des doublets finaux d'un collisionneur linéaire

Bolzon, Benoît 12 November 2007 (has links) (PDF)
CLIC est un des projets actuels de construction d'un collisionneur linéaire de haute énergie. La taille verticale des faisceaux de 0,7nm lors de la collision et le mouvement rapide du sol de quelques nanomètres imposent une stabilisation active des doublets finaux au cinquième de nanomètre au-dessus de 4Hz.<br />La majorité de mon travail a porté sur l'étude des vibrations et de la stabilisation active de poutres en porte-à-faux et élancées afin de représenter les doublets finaux de CLIC.<br />Dans une première partie, les performances mesurées de différents types de capteurs de vibration associés à une instrumentation appropriée ont montré que des mesures précises du mouvement du sol sont possibles de 0,1Hz jusqu'à 2000Hz sur un site calme. Egalement, des capteurs électrochimiques répondant à priori au cahier des charges de CLIC peuvent être incorporés dans la stabilisation active au cinquième de nanomètre.<br />Dans une deuxième partie, une étude expérimentale et numérique des vibrations d'une poutre a permis de valider l'efficacité de la prédiction numérique incorporée par la suite dans la simulation de la stabilisation active. Egalement, une étude de l'impact du mouvement du sol et du bruit acoustique sur les vibrations d'une poutre a montré qu'une stabilisation active est nécessaire jusqu'à au moins 1000Hz.<br />Dans une troisième partie, les résultats sur la stabilisation active d'une poutre à ses deux premières résonances sont montrés jusqu'à des amplitudes d'un dixième de nanomètre au-dessus de 4Hz en utilisant en parallèle un système commercial réalisant une stabilisation passive et active de l'encastrement.<br />La dernière partie a porté sur une étude d'un support pour les doublets finaux d'un prototype d'un collisionneur linéaire en phase de finalisation, le prototype ATF2. Ce travail a montré que le mouvement relatif entre ce support et le sol est en-dessous des tolérances imposées (6nm au-dessus de 0,1Hz) avec des conditions aux limites appropriées.
4

Contribution à l'étalonnage d'une machine à mesurer de très haute précision : mesure de rectitude et de planéité à un niveau d'incertitudes nanométriques

Boripatkosol, Siriwan 07 October 2010 (has links) (PDF)
L'objet de ce travail est de proposer une étude métrologique visant à la maîtrise d'incertitudes de l'ordre de ±10 nanomètres sur une rectitude de longueur 300mm mesurée avec un pas constant. Une extension permet d'appliquer cette méthode au cas de la planéité. Le plan ainsi étalonné est destiné à constituer la référence verticale d'une table croisée de haute exactitude développée par le Laboratoire National de Métrologie et d'Essais. Une instrumentation basée sur une matrice carrée de 16 capteurs capacitifs distants de 20mm et une paire de niveaux électroniques a été développée. Les acquisitions sont réalisées avec un pas égal à la distance entre les capteurs. La redondance des mesures permet de séparer les défauts de mise en position du porte-capteur, les écarts de forme de l'élément à étalonner et les inconnues correspondantes à la connaissance des positions relatives des capteurs. La méthodologie proposée correspond à un processus dit de mesure par propagation. L'utilisation de l'hypothèse des petits déplacements conduit à la résolution d'un système linéaire surdéterminé. Nous montrons que le choix des unités des mesures provenant soit des indications des capteurs exprimées en unité de longueur soit des niveaux exprimés en unité d'angle a l'effet d'une pondération. C'est pourquoi nous mettons en œuvre une résolution au sens des moindres carrés pondérés. Nous étudions particulièrement les solutions dites extrêmes selon que les incertitudes des capteurs sont négligeables devant celles des niveaux ou réciproquement. Nous réalisons une étude métrologique du processus de mesure incluant la phase d'étalonnage sur la base d'un raccordement à un laser interférométrique. Nous simulons les incertitudes par une méthode de Monte-Carlo. Nous en déduisons deux méthodes conduisant à proposer une pondération optimale du système. Nous montrons une reproductibilité sur 10 acquisitions contenue dans une bande de ±5 nanomètres par rapport à la moyenne des profils mesurés.

Page generated in 0.0362 seconds