• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aukštadvario, Sukončių ir Pabradės hidroelektrinių darbo efektyvumo tyrimai / Aukstadvaris, Sukonciai and Pabrade small hydropower plant analysis

Gaidys, Vytautas 14 January 2009 (has links)
Žinome, kad Lietuva didelių vandens išteklių neturi.Todėl racionalus jų naudojimas, kai nedaroma žala gamtai, arba ji visiškai nereikšminga, – kiekvieno hidroenergetiko rūpestis. Neišnagrinėjus visų, su tuo susijusių reiškinių, klaidingai apskaičiavus ir įvertrinus sukauptus duomenis mažose hidroelektrinėse, ne tik bus neefektyvus vandens panaudojimas, bet ir gali būti katastrofinės pasekmės, galinčios neigiamai paveikti gamtinę aplinką. Esami šalies vandens ištekliai – brangus mūsų turtas, todėl reikia stengtis, kad hidroenergetikoje panaudotas kiekvienas kubinis metras vandens, atneštų kuo didesnę naudą visuomenei. Trijose mažosiose Lietuvos hidroelektrinėse: Aukštadvario, Sukončių ir Pabradės buvo atliekami tyrimai, kiek vandens sunaudoja kiekviena elektrinė atskirai, kokia pratekančio vandens energija, esant skirtingiems patvankų aukščiams, bei kaupiami duomenys, kiek kiekviena elektrinė pagamina elektros energijos (kW). Pradėjus sisteminti elektrinėse sukauptus duomenis, buvo sudaryta pro turbinas pratekančio vandens ir išgaunamos elektros energijos kiekio (kW) skaičiavimo metodika. Iš gautų duomenų išvedamos hidroelektrinių efektyvumo kreivės, kurios palyginamos su kitų gamintojų hidroagregatų efektyvumo duomenimis. Prasminiai žodžiai: racionalus naudojimas, naudingumo koeficientas, efektyvumas. / The problem considered in this paper is that there aren’t many natural water resources in Lithuania. That’s why, rational consumption of water with any or very insignificant harm to the nature done, is a matter of great concern of every hydroenergetic. All matters should be taken into consideration. However, without bearing in mind all the concerning matters, having incorrect technical data or its incorrect evaluation may lead to ineffective usage of water resources in little water-power stations and even catastrophic consequences, that may affect natural environment. Available water resources are precious. So, it is important to strive to use every cubic metre of water in hydroenergetics to be of the greatest benefit for the society. Three small hydropower plants in Aukstadvaris, Sukonciai and Pabrade were tested for amount of water consumption and for flowing water energy with different water head. Also there was collected data about produced electrical energy in every water- power station (kWh). After having organized all the data, was worked out technique how to count amount of water flowing through turbines and also amount of electricity (kWh) generated by those turbines. The facts make the output graphs that are compared with other producers aggregates’ data of efficiency. Keywords: rational usage, coefficient of efficiency, efficiency.
2

Centrinio šildymo kieto kuro katilo ,,Kalvis - 4D'' parametrų tyrimas / Reaserch parameters of central heating solid fuel boiler ,,Kalvis – 4D’’

Stašys, Gintaras 31 August 2012 (has links)
Šiame darbe pateikti kuro kaloringumo priklausomybės nuo drėgmės skaičiavimai. Atlikus bandymus, nustatyta katilo nominali ir minimali galia. Skaičiuojant tiesioginiu ir netiesioginiu metodu nustatytas katilo naudingumo keficientas. Atlikta katilo korpuso įtempimo būvio analizė. Buvo skaičiuojama katilo šiluminė varža, pateikti pasiūlymai katilo techninių parametrų gerinimui. / This paper presents the dependence on fuel moisture calorie calculations, tests the boiler nominal and minimum power. Calculation of direct and indirect method keficientas the boiler. Boiler body made of life stress analysis. The calculated resistance of the boiler įiluminė, proposals to improve technical parameters of the boiler.
3

Kuro elementai ir jų panaudojimo galimybės, aprūpinant pastatų kompleksą energija / Fuel Cells and Their Application Possibilities for Buildings Complex Power Supply

Pakulytė, Giedrė 20 June 2006 (has links)
Human’s energy demand is growing and there is a necessity to solve questions of sustainable energetics, such as security of energy supply, energy efficiency and environment protection. Possible way of the solution of these problems is new and more efficient technologies and new energy sources. Fuel cells are one of the developing and environmentally clean technologies. This master’s report is dealing with cogeneration technologies and only fuel cells are analyzed thoroughly. Most usable type of fuel cells for decentralized power and heat generation is identified and its operating principles and properties are analyzed. Advantages and disadvantages of solid oxide fuel cells are given. Power of the fuel cell is chosen in the particular case, when energy demand of building complex of the hospital is analyzed. The fuel cell is integrated into the energy supply system with other equipment. There are made several alternatives to estimate the operation of the system technologically and economically. The simple pay back period and the net present value are used to estimate economical benefit of the system, when prices of energetic sources and fuel cells are varied. Finally, academic knowledge and calculation results are summarized and conclusions of the final report are given.
4

Mažos galios hidroelektrinės energetiniai tyrimai / Energetic Research of Low Power Hydroelectroplant / Енергетические исследования мини гидроэлектростанция

Ozgirdas, Romualdas 09 June 2009 (has links)
Darbe ištirti veikiančios mažos galios hidroelektrinės generatorių parametrai, įvertinant teorinius skaičiavimus ir eksperimentinių tyrimų rezultatus ir jų priklausomybė nuo vandens debito.Turbina paleidžiama įvairiais režimais, tam kad būtų galima sudaryti P; Q, S grafikų priklausomybę nuo vandens tekėjimo debito. Parodymai nuimami, šešis kartus, turbinai dirbant įvairiuose režimuose, kompiuterio pagalba. Parodymai pridėti prieduose. Ištirta turbinos naudingumo koeficiento priklausomybė nuo vandens debito ir jo įtaka P, Q, S parametrams. Pasinaudojus gautais grafikais nustatytas ekonomiškiausias turbinos darbo režimas. Atlikus grafikų analizę galima teigti, kad esant mažam vandens debitui turbinos dirba neekonomiškai. Turbina gali pradėti dirbti tik nuo 5 . Tai parodo, kad turbinos yra parinktos neekonomiškam darbo režimui. Remiantis tyrimo rezultatais siūloma statyti mažesnės galios turbiną. Pateikti ekonominiai skaičiavimai dirbant turbinai, esant mažai vertei yra nuostolinga. Pagrindinis dėmesys atkreiptas į sanitarinį vandens debitą, kuris yra 0,74 . Esant tokiam vandens debitui siūloma statyti atskirą turbiną kuri dirbtų ekonomiškai ištisus metus. / Darbe ištirti veikiančios mažos galios hidroelektrinės generatorių parametrai, įvertinant teorinius skaičiavimus ir eksperimentinių tyrimų rezultatus ir jų priklausomybė nuo vandens debito.Turbina paleidžiama įviriais režimais, tam kad būtų galima sudaryti P; Q, S grafikų priklausomybę nuo vandens tekėjimo debito. Parodymai nuimami, šešis kartus, turbinai dirbant įvairiuose režimuose, kompiuterio pagalba. Parodymai pridėti prieduose. Ištirta turbinos naudingumo koeficiento priklausomybė nuo vandens debito ir jo įtaka P, Q, S parametrams. Pasinaudojus gautais grafikais nustatytas ekonomiškiausias turbinos darbo režimas. Atlikus grafikų analizę galima teigti, kad esant mažam vandens debitui turbinos dirba neekonomiškai. Turbina gali pradėti dirbti tik nuo 5 . Tai parodo, kad turbinos yra parinktos neekonomiškam darbo režimui. Remiantis tyrimo rezultatais siūloma statyti mažesnės galios turbiną. Pateikti ekonominiai skaičiavimai dirbant turbinai, esant mažai vertei yra nuostolinga. Pagrindinis dėmesys atkreiptas į sanitarinį vandeans debitą, kuris yra 0,74 . Esant tokiam vandens debitui siūloma statyti atskirą turbiną kuri dirbtų ekonomiškai ištisus metus. / Магистранскай работе исследованны параметры турбины малой мочносты, имейя виду теоретические расщёты и экспериментальные результаты о также зависимость их от дебета боды. Турбину запускаем разными режимамы, для того чтобы можно было составить график работ P; Q; S; зависимость от дебета боды. Показания снимаем шесть раз при помощи компютера. Показания приложены к дополниением. Исследован коэфициент полезной деятельности , его зависимость от дебета воды, влияния на P; Q; S; параметры. Установлений самый экономический режим. Турбина может работать только от Это показывает, что не правильно падобраны турбины. Предлагаю ставить меньшей мочносты. Представлены расчеты показывает что работа турбин при малой оценки убыточные. Главное внимание обращено на санитарный дебет, который есть Предлагаю поставить турбину на этот режим. Она работала круглый год.

Page generated in 0.2399 seconds