• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Near Infrared Fluorescent Imaging of Brain Tumor With IR780 Dye Incorporated Phospholipid Nanoparticles

Li, Shihong, Johnson, Jennifer, Peck, Anderson, Xie, Qian 23 January 2017 (has links)
Background: Near-IR fluorescence (NIRF) imaging is becoming a promising approach in preclinical tumor detection and clinical image-guided oncological surgery. While heptamethine cyanine dye IR780 has excellent tumor targeting and imaging potential, its hydrophobic property limits its clinical use. In this study, we developed nanoparticle formulations to facilitate the use of IR780 for fluorescent imaging of malignant brain tumor. Methods: Self-assembled IR780-liposomes and IR780-phospholipid micelles were prepared and their NIRF properties were characterized. The intracellular accumulation of IR780-nanoparticles in glioma cells were determined using confocal microscopy. The in vivo brain tumor targeting and NIRF imaging capacity of IR780-nanoparticles were evaluated using U87MG glioma ectopic and orthotopic xenograft models and a spontaneous glioma mouse model driven by RAS/RTK activation. Results: The loading of IR780 into liposomes or phospholipid micelles was efficient. The particle diameter of IR780-liposomes and IR780-phospholipid micelles were 95 and 26nm, respectively. While stock solutions of each preparation were maintained at ready-to-use condition, the IR780-phospholipid micelles were more stable. In tissue culture cells, IR780-nanoparticles prepared by either method accumulated in mitochondria, however, in animals the IR780-phospholipid micelles showed enhanced intra-tumoral accumulation in U87MG ectopic tumors. Moreover, IR780-phospholipid micelles also showed preferred intracranial tumor accumulation and potent NIRF signal intensity in glioma orthotopic models at a real-time, non-invasive manner. Conclusion: The IR780-phospholipid micelles demonstrated tumor-specific NIRF imaging capacity in glioma preclinical mouse models, providing great potential for clinical imaging and image-guided surgery of brain tumors.
2

Localisation du ganglion sentinelle au moyen de nanoparticules fluorescentes émettant dans le proche infrarouge : application au cancer du sein / Mapping of sentinel lymph node with near-infrared emitting nanoparticles : Breast cancer application

Helle, Marion 14 November 2012 (has links)
La biopsie du ganglion sentinelle (GS) est actuellement la technique de référence pour le diagnostic des métastases ganglionnaires du cancer du sein. Cependant, les traceurs utilisés pour la cartographie du GS (colorant bleu et radiocolloïde) ne sont pas idéaux et peuvent occasionner des réactions allergiques et engendrer des coûts importants. Une alternative à l'utilisation de ces traceurs repose sur le repérage du GS par imagerie de fluorescence proche infrarouge à l'aide de nanoparticules. Deux types de nanoparticules ont été étudiés : les Quantum Dots (QDs) à base d'indium et les nanoparticules de silice (NPSi) renfermant de la cyanine 7. Dans un modèle murin de carcinome mammaire, tous les GS envahis par les métastases ont pu être visualisés grâce à la fluorescence des QDs-indium. L'étude de biodistribution a mis en évidence une capture majeure des QDs au point d'injection et dans les ganglions associée à une faible concentration dans le foie et la rate. La toxicité des QDs a été évaluée in vitro et a démontré une toxicité fortement réduite des QDs-indium par rapport aux QDs-cadmium. Les NPSi présentent les avantages suivants : biocompatibilité, amélioration de la rétention dans le ganglion et des propriétés photophysiques par rapport au fluorophore libre. Le GS est rapidement visualisable par fluorescence suite à l'injection de NPSi. Le suivi des souris, pendant 3 mois post-injection, n'a révélé aucun signe de toxicité générale ou hépatique. Ces deux types de nanoparticules fluorescentes sont particulièrement bien adaptés à la cartographie du GS et pourraient avantageusement remplacer les traceurs employés actuellement / Sentinel lymph node (SLN) biopsy is a reliable technique for the diagnosis of metastases in breast cancer. However, the tracers used (blue dye and radiocolloid) are not optimal because they can cause allergic reactions and major costs in waste processing. Our strategy was to use near-infrared emitting nanoparticles for the mapping of SLN: indium-based Quantum Dots (QDs) and cyanine 7 embedded in silica nanoparticles (SiNP). In a murine model of mammary carcinoma, all SLN containing lymphatic metastases could be visualized with fluorescent indium-based QDs. The biodistribution study concluded that the major organs of retention were the injection point and lymph nodes whereas liver and spleen accumulated fewer QDs. The cytotoxicity tests demonstrated a weak in vitro toxicity of indium- compared to cadmium-based QDs. SiNP show several advantages over free fluorophore such as biocompatibility, better retention in the SLN and greatest photophysical properties. SLN could be mapped as soon as 5 minutes after SiNP injection. The in vivo toxicity in mice was followed during 3 months after injection and did not reveal any signs of general or hepatic toxicity. Both fluorescent nanoparticles are thus well adapted for the mapping of the SLN and could be a favourable substitute to the actually tracers
3

Caractérisation d'un modèle cellulaire et animal orthotopique des cancers des VADS : du ciblage tumoral in vitro ou rôle de l'imagerie de fluorescence in vivo dans l'exérèse tumorale / Characterization of a cellular and an orthotopic animal model of head and neck cancer : from in vitro tumor targeting to in vivo fluorescence imaging-guided tumor resection

Atallah, Ihab Nader Tawfik 30 June 2014 (has links)
Introduction : La thérapie ciblée des cancers des VADS nécessite la mise au point de nouveaux vecteurs spécifiques. Ces vecteurs servent à acheminer des substances thérapeutiques, mais aussi ils peuvent être couplés à des fluorophores afin de les utiliser dans la chirurgie guidée par l'imagerie de fluorescence proche infrarouge.Objectifs : L'objectif de notre travail est de tester de nouveaux vecteurs des cancers des VADS et d'étudier l'apport de l'imagerie de fluorescence proche infrarouge dans la chirurgie des cancers des VADS chez un modèle animal orthotopique que nous mettons au point.Matériel et méthodes : La lignée cellulaire des cancers des VADS CAL33 est caractérisée in vitro et in vivo. De nouveaux vecteurs qui ciblent un ou plusieurs récepteurs des cellules CAL33 comme l'intégrine alpha v beta 3, l'EGFR et la NRP1, sont testés in vitro. Parallèlement, un modèle animal orthotopique des cancers des VADS est développé par implantation de fragments tumoraux des cellules CAL33, au niveau de la cavité buccale de la souris nude. La résection des tumeurs orthotopiques est guidée par l'imagerie de fluorescence proche infrarouge, après injection systémique du peptide RAFT-c[RGD]4 couplé à un fluorophore. Ce peptide cible l'intégrine alpha v beta 3 et est préalablement testé in vivo sur les cellules CAL33.Résultats : Nos résultats préliminaires montrent que certaines molécules bispécifiques présentent une liaison accrue in vitro aux cellules CAL33. Par ailleurs, la chirurgie guidée par l'imagerie de fluorescence proche infrarouge ciblant l'intégrine alpha v beta 3, présente un impact positif sur la survie sans rechute dans notre modèle orthotopique, à travers la détection de reliquats tumoraux qui pourraient passer inaperçus si l'exérèse tumorale avait été réalisée exclusivement d'une façon macroscopique. Elle permet aussi de détecter les adénopathies métastatiques.Conclusion : L'imagerie de fluorescence proche infrarouge améliore la qualité de l'exérèse tumorale dans notre modèle orthotopqiue optimisé des cancers des VADS. Cette étape préclinique est indispensable avant de tester cette technique chez l'être humain. / Introduction: Targeted therapy of head and neck squamous cell carcinoma (HNSCC) requires the development of novel specific vectors that can deliver therapeutic molecules. These vectors could also be coupled to fluorophores to be used in near infrared fluorescence imaging-guided surgery.Objectives: The aim of our work is to test new targeted vectors of HNSCC and to study the role of the near infrared fluorescence imaging-guided surgery in HNSCC resection in a novel orthotopic animal model that we develop.Materials and Methods: The HNSCC cell line CAL33 is characterized in vitro and in vivo. Novel vectors that target one or more receptors of this cell line such as alpha v beta 3 integrin, EGFR and NRP1, are tested in vitro. Meanwhile, an orthotopic animal model of HNSCC is developed by implanting tumor fragments of CAL33 cells, in the oral cavity of nude mice. Surgical resection of orthotopic tumors is guided by the near infrared fluorescence imaging after systemic injection of RAFT-c[RGD]4 peptide coupled with a fluorophore. This peptide targets alpha v beta 3 integrin and is previously tested in vitro.Results: Our preliminary results show that bispecific vectors would present an increased binding to CAL33 cells in vitro. On the other hand, near infrared fluorescence imaging-guided surgery has a positive impact on the recurrence-free survival rate in our orthotopic model, by detecting fluorescent cancer foci that could remain unidentified if resection was performed exclusively under visual guidance. Our results show also that near infrared fluorescence imaging can also help to detect metastatic lymph nodes.Conclusion: Near-infrared fluorescence imaging-guided surgery improves the quality of tumor resection in our optimized orthotopic animal model of HNSCC. This preclinical stage is essential before testing this novel technique in humans.

Page generated in 0.1233 seconds