• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 33
  • 5
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 95
  • 95
  • 31
  • 18
  • 16
  • 14
  • 13
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

AN EFFICIENT SEQUENTIAL INTEGER OPTIMIZATION TECHNIQUE FOR PROCESS PLANNING AND TOLERANCE ALLOCATION

KANSARA, SHARAD MAHENDRA January 2003 (has links)
No description available.
32

LARGE SCALE LINEAR OPTIMIZATION FOR WIRELESS COMMUNICATION SYSTEMS

Hosny, Sameh Shawky Ibrahim 23 May 2017 (has links)
No description available.
33

Quality constrained scheduling of mining operations

Bai, Yang January 1994 (has links)
No description available.
34

Misuse Detection in Dynamic Spectrum Access Networks

Bhadriraju, Abhay Rao 01 July 2014 (has links)
With dynamic spectrum access emerging as an important paradigm for efficient spectrum use, mechanisms are required to ensure disciplined spectrum access by secondary users. This must be done without requiring secondary users to disclose private data, such as their exact usage pattern or identities of parties involved. We formulate, design and evaluate a mechanism to collect spectrum activity information using a set of CPEs. A system design is presented which uses a number of techniques to address mobility and security issues involved in relying on CPEs to collect spectrum activity information. The system imposes an observation probability such that a rational cheater is dissuaded from spectrum misuse. The minimum number of CPEs required to impose this observation probability is determined by formulating it as an integer linear program. The security and privacy of this system is analyzed, along with simulation results to evaluate the quality of the solution. Based on the current design, directions for future work are identified and preliminary approaches are presented. / Master of Science
35

SOBRE O PROBLEMA DE DESIGNAÇÃO DE SALAS DE AULA PARA A PUC GOIÁS: UM ESTUDO DE CASO PARA A ÁREA 3, CAMPUS I / THE PROBLEM OF CLASSROOM ASSIGNMENT PROBLEM FOR THE PUC GOIÁS: A CASE STUDY FOR AREA 3, CAMPUS I

Campos, Geovane Reges de Jesus 04 September 2012 (has links)
Made available in DSpace on 2016-08-10T10:40:17Z (GMT). No. of bitstreams: 1 Geovane Reges de Jesus Campos.pdf: 308868 bytes, checksum: 7d7dde587ca6eede4281609bfad2c151 (MD5) Previous issue date: 2012-09-04 / This paper presents a study for the classroom assignment problem for the PUC Goiás, Area 3, Campus I, based on a programming system (SAPA), the Hungarian algorithm, and on the idea of solving the problem time by time. The problem is solved with real data no more than 6 seconds. / Este trabalho apresenta um estudo para o problema de designação de salas de aula para a PUC Goiás, área 3, Campus I, baseado em um sistema de programação (SAPA), no algoritmo Húngaro e na idéia de resolver o problema horário por horário. O problema é resolvido, com dados reais, em não mais do que 6 segundos.
36

O PROBLEMA DE DESIGNAÇÃO DE SALAS DE AULA DA PUC GOIÁS.

Ribeiro, Jeancarlo 17 June 2013 (has links)
Made available in DSpace on 2016-08-10T10:40:20Z (GMT). No. of bitstreams: 1 JEANCARLO RIBEIRO.pdf: 683766 bytes, checksum: 28e6690b67012436dd91788ec7ff346b (MD5) Previous issue date: 2013-06-17 / The classroom assignment problem at universities consist in distributing classes scheduled for the appropriate rooms, respecting the requirements in each situation. The objective of this work is to apply the Hungarian algorithm and a computational system to solve the classroom assignment problem time by time. The tests were performed with real data from the PUC Goiás for a quantitative of 5116 classes into 313 classrooms. As a result, we solved the problem in approximately 12 minutes and the solution quality was compared with manual designation usually applied by the institution, which takes a month and a half. / O problema de designação de salas de aula em Universidades consiste em distribuir turmas programadas para as devidas salas, respeitando os requisitos estabelecidos em cada situação. O objetivo deste trabalho é a aplicação do algoritmo húngaro e de um sistema computacional para a resolução do problema de alocação horário por horário. Os testes foram realizados com dados reais da PUC Goiás para um quantitativo de 5116 turmas em 313 salas de aula. Como resultados, resolvemos o problema em aproximadamente 12 minutos e comparamos a qualidade da solução com a designação manual usualmente realizada pela Instituição, a qual leva um mês e meio.
37

MELHORIAS PARA O PROBLEMA DE DESIGNAÇÃO DE SALAS DE AULA DA PUC GOIÁS.

Alarcão, Davi Taveira Alencar 07 February 2015 (has links)
Made available in DSpace on 2016-08-10T10:40:24Z (GMT). No. of bitstreams: 1 Davi Taveira Alencar Alarcao.pdf: 944757 bytes, checksum: 30d55936bd0acaff3d7ecf1816fe22f5 (MD5) Previous issue date: 2015-02-07 / The classroom assignment problem at universities consist in distributing classes scheduled for the appropriate rooms, respecting the requirements in each situation. The objective of this work is to improve the process of allocation of classroom PUC Goiás. The tests were performed with real data from the PUC Goiás for a quantitative of 5116 classes into 312 classrooms. As a result, we solved the problem in approximately 34 minutes and the solution quality was compared both with manual designation usually applied by the institution, which takes a month and a half, as with the results found in Ribeiro (2012). / O problema de designação de salas de aula em Universidades consiste em distribuir turmas programadas para as devidas salas, respeitando os requisitos estabelecidos em cada situação. O objetivo deste trabalho é o de melhorar o processo de alocação de salas de aula da PUC Goiás. Os testes foram realizados com dados reais da PUC Goiás para um quantitativo de 5116 turmas em 312 salas de aula. Como resultados, resolvemos o problema em aproximadamente 34 minutos e comparamos a qualidade da solução tanto com a designação manual usualmente realizada pela Instituição, a qual leva um mês e meio, quanto com os resultados encontrados em Ribeiro (2012).
38

Determinação de parâmetros do circuito equivalente térmico de transformadores de potência por meio de técnicas de otimização. / Determination of power transformer equivalent thermal circuit parameters by optimization techniques.

Tamura, Leandro Fumio 24 June 2009 (has links)
Transformadores de potência representam um grande volume de investimento em sistemas de transmissão e distribuição. Falhas em transformadores têm um alto impacto econômico na exploração de uma rede. O parâmetro mais importante e que define a vida útil de isolação de um transformador é a temperatura do ponto mais quente de seus enrolamentos. O trabalho analisa dois modelos térmicos de transformadores de potência. Eles nos permitem calcular as temperaturas do óleo no topo e na parte inferior e a temperatura do ponto quente no enrolamento. Ambos os modelos são baseados em circuitos elétricos a parâmetros concentrados. O primeiro é uma proposta de Susa, que envolve a solução de dois circuitos elétricos acoplados. Já Tang sugere um segundo modelo, que consiste em um circuito elétrico de três nós. O principal objetivo deste trabalho é a obtenção dos parâmetros térmicos de ambos os modelos baseados em temperaturas medidas para uma determinada carga. Duas abordagens diferentes de otimização serão avaliadas: uma mono objetivo e outra multi objetivo. A segunda oferece-nos uma análise de sensibilidade de parâmetros do modelo. Ambos os métodos de otimização foram utilizadas para obter os parâmetros térmicos de um transformador de potência 250 MVA resfriamento ONAN (Óleo Natural, Ar Natural). Os parâmetros obtidos do modelo térmico são então utilizadas para outras curvas de carga e também são comparadas com a norma IEEE C57.91 1995 com boa precisão. / Power transformers represent a large amount of investment in transmission and distribution systems. Faults in transformers have a high economic impact in the operation of a network. One of the most important parameters that govern the life of transformers is its hotspot temperature, which defines the loss of life of the equipament. The work analyzes two thermal models for a power transformer. They allow us to calculate the top oil temperature, the bottom oil temperature and the hotspot temperature of power transformers. Both models are based on lumped parameters. The first one is proposed by Susa, and involves the solution of two coupled electrical circuits. Tang suggests the second one, which consists on an electric circuit of three nodes to be solved. The main objective of this work is to obtain the thermal lumped parameters of both models based on measured temperatures for a given load curve. Two different approaches will be adopted: a mono-objective optimization and a multiobjective optimization. The second one provides us a sensitivity analysis of the model parameters. Both optimization methods were used to obtain the thermal lumped parameters in a 250 MVA ONAN power transformer. The obtained parameters of the thermal model are then used for other load curves and compared with the guide IEEE C57.91 1995 with good accuracy.
39

Otimização dos custos de energia elétrica na programação do armazenamento e distribuição de água em redes urbanas / Minimization of the electrical energy cost in water distribution networks

Soler, Edilaine Martins 22 February 2008 (has links)
O problema abordado nesta pesquisa consiste na distribuição de água em redes urbanas para o atendimento de demandas conhecidas, com o objetivo de minimizar o custo da energia elétrica necessária para o funcionamento de bombas hidráulicas. As bombas hidráulicas são utilizadas para captar água de poços artesianos ou estações de tratamento de água para abastecer reservatários distribuídos por bairros de uma cidade, de onde a população será atendida por força gravitacional. Como o custo da energia elétrica varia ao longo do dia, se faz necessário um planejamento do funcionamento das bombas para que não sejam ligadas nos horários em que a energia elétrica é mais cara. O problema de planejamento de estoque de água em reservatórios (PPEAR) consiste em decidir em quais períodos ou frações dos períodos do horizonte de planejamento as bombas hidráulicas que abastecem os reservatórios devem permanecer ligadas e em quais períodos ou frações dos períodos deve haver transporte de água entre os reservatórios para que a demanda de cada reservatório seja atendida em cada período e sejam respeitados os níveis mínimos e máximos de água nos reservatórios. Uma solução heurística para resolver o PPEAR é proposta e analisada por comparação com as soluções obtidas pelo método de enumeração implícita. Resultados computacionais comprovam a eficiência da abordagem, tanto pela qualidade das soluções como pelo baixo tempo de resposta / The problem focused in this study consists of reducing the eletrical energy cost necessary to the operation of hydraulic pumps. The hydraulic pumps are used to catch water from artesians wells or Water Treatment Station to supply tanks which are located in districts in a city, from which the population will be supplied by gravitational force. As the cost of electrical energy varies along the day, a schedule of the pumps run is necessary to avoid that they are not turned in the periods when the energy cost is more expensive. The problem of water stock schedule in tanks (WSST) consists of deciding in which periods or parts of them of the horizon planning the hydraulic pumps have to put on, and in which periods or parts of them should transfer water among the tanks so that the demand of each tank is met for each period and lower and upper limits of water shouldn\'t be violated. A heuristic solution is proposed and analyzed by comparing its solutions with the solutions obtained by the branch and bound method. Computational experiments show the efficiency of the heuristic
40

Determinação de parâmetros do circuito equivalente térmico de transformadores de potência por meio de técnicas de otimização. / Determination of power transformer equivalent thermal circuit parameters by optimization techniques.

Leandro Fumio Tamura 24 June 2009 (has links)
Transformadores de potência representam um grande volume de investimento em sistemas de transmissão e distribuição. Falhas em transformadores têm um alto impacto econômico na exploração de uma rede. O parâmetro mais importante e que define a vida útil de isolação de um transformador é a temperatura do ponto mais quente de seus enrolamentos. O trabalho analisa dois modelos térmicos de transformadores de potência. Eles nos permitem calcular as temperaturas do óleo no topo e na parte inferior e a temperatura do ponto quente no enrolamento. Ambos os modelos são baseados em circuitos elétricos a parâmetros concentrados. O primeiro é uma proposta de Susa, que envolve a solução de dois circuitos elétricos acoplados. Já Tang sugere um segundo modelo, que consiste em um circuito elétrico de três nós. O principal objetivo deste trabalho é a obtenção dos parâmetros térmicos de ambos os modelos baseados em temperaturas medidas para uma determinada carga. Duas abordagens diferentes de otimização serão avaliadas: uma mono objetivo e outra multi objetivo. A segunda oferece-nos uma análise de sensibilidade de parâmetros do modelo. Ambos os métodos de otimização foram utilizadas para obter os parâmetros térmicos de um transformador de potência 250 MVA resfriamento ONAN (Óleo Natural, Ar Natural). Os parâmetros obtidos do modelo térmico são então utilizadas para outras curvas de carga e também são comparadas com a norma IEEE C57.91 1995 com boa precisão. / Power transformers represent a large amount of investment in transmission and distribution systems. Faults in transformers have a high economic impact in the operation of a network. One of the most important parameters that govern the life of transformers is its hotspot temperature, which defines the loss of life of the equipament. The work analyzes two thermal models for a power transformer. They allow us to calculate the top oil temperature, the bottom oil temperature and the hotspot temperature of power transformers. Both models are based on lumped parameters. The first one is proposed by Susa, and involves the solution of two coupled electrical circuits. Tang suggests the second one, which consists on an electric circuit of three nodes to be solved. The main objective of this work is to obtain the thermal lumped parameters of both models based on measured temperatures for a given load curve. Two different approaches will be adopted: a mono-objective optimization and a multiobjective optimization. The second one provides us a sensitivity analysis of the model parameters. Both optimization methods were used to obtain the thermal lumped parameters in a 250 MVA ONAN power transformer. The obtained parameters of the thermal model are then used for other load curves and compared with the guide IEEE C57.91 1995 with good accuracy.

Page generated in 0.1156 seconds