Seismic Performance Comparison of a Fixed-Base Versus a Base-Isolated Office BuildingMarrs, Nicholas Reidar 01 June 2013 (has links) (PDF)
The topic of this thesis is base isolation. The purpose of this thesis is to offer a relative understanding of the seismic performance enhancements that a typical 12-story steel office building can achieve through the implementation of base isolation technology. To reach this understanding, the structures of a fixed-base office building and a base-isolated office building of similar size and layout are designed, their seismic performance is compared, and a cost-benefit analysis is completed. The base isolation system that is utilized is composed of Triple Friction Pendulum (TFP) bearings.
The work of this thesis is divided into four phases. First, in the building selection phase, the structural systems (SMF and SCBF), layout, location (San Diego, CA), and design parameters of the buildings are selected. Then, in the design phase, each structure is designed using modal response spectrum analysis in ETABS. In the analysis phase, nonlinear time history analyses at DBE and MCE levels are conducted in PERFORM-3D to obtain the related floor accelerations and interstory drifts. Finally, in the performance assessment phase, probable damage costs are computed using fragility curves and FEMA P-58 methodology in PACT. Damage costs are computed for each building and seismic demand level and the results are compared.
|
12 |
Seismic Strengthening Of A Mid-rise Reinforced Concrete Frame Using Cfrps: An Application From Real LifeTan, Mustafa Tumer 01 May 2009 (has links) (PDF)
SEISMIC STRENGTHENING OF A
MID-RISE REINFORCED CONCRETE FRAME
USING CFRPs: AN APPLICATION FROM REAL LIFE
Tan, Mustafa Tü / mer
M.S., Department Of Civil Engineering
Supervisor: Prof. Dr. Gü / ney Ö / zcebe
Co-Supervisor: Assoc. Prof. Dr. BariS Binici
May 2009, 162 pages
FRP retrofitting allows the utilization of brick infill walls as lateral load resisting elements. This practical retrofit scheme is a strong alternative to strengthen low to mid-rise deficient reinforced concrete (RC) structures in Turkey. The advantages of the FRP applications, to name a few, are the speed of construction and elimination of the need for building evacuation during construction. In this retrofit scheme, infill walls are adopted to the existing frame system by using FRP tension ties anchored the boundary frame using FRP dowels. Results of experiments have previously shown that FRP strengthened infill walls can enhance lateral load carrying capacity and reduce damage by limiting interstory drift deformations. In previous, analytical studies, a detailed mathematical model and a simplified version of the model for compression struts and tension ties was proposed and verified by comparing model estimations with test results.
In this study, an existing 9-storey deficient RC building located in Antakya was chosen to design and apply a hybrid strengthening scheme with FRPs and reduced number of shear walls. Linear elastic analysis procedure was utilized (force based assessment technique) along with the rules of Mode Superposition Method for the reftrofit design. FRP retrofit scheme was employed using the simplified model and design was conducted such that life safety performance criterion is satisfied employing elastic spectrum with 10% probability of exceedance in 50 years according to the Turkish Earthquake Code 2007. Further analytical studies are performed by using Modal Pushover and Nonlinear Time-History Analyses. At the end of these nonlinear analyses, performance check is performed according to Turkish Earthquake Code 2007, using the strains resulting from the sum of yield and plastic rotations at demand in the critical sections.
CFRP retrofitting works started at October 2008 and finished at December 2008 for the building mentioned in this study. Eccentric reinforced concrete shearwall installation is still being undertaken. All construction business is carried out without evacuation of the building occupants. This project is one of the first examples of its kind in Turkey.
Keywords: CFRP, Carbon Fiber Reinforced Polymers, Masonry Infill Walls, Reinforced Concrete Infill Walls, Mid-Rise Deficient Structures, Turkish Earthquake Code 2007, Modal Pushover Analysis, Nonlinear Time History Analysis, Linear Elastic Building Assessment
|
13 |
Comportamiento estructural de una edificación esencial de mediana altura usando aisladores de base y disipadores SLBAguirre Herrera, Santiago Alberto, Vidal Barazorda, Elio Andre 09 January 2021 (has links)
Este artículo consiste en analizar una nueva alternativa de control antisísmico de alta tecnología para la construcción de hospitales en el Perú, que en su normativa exige el uso de aislamiento de base para edificaciones esenciales. Para ello, se opta por la evaluación estructural de una edificación construida con aisladores sísmicos y la misma con implementación del sistema de disipación de energía SLB (Shear Link Bozzo). Los resultados analizados, para cada técnica estudiada de control antisísmico, son: derivas de entrepiso, aceleraciones de piso, balance energético y análisis de rotulas plásticas, en base a la filosofía de funcionalidad continua. / This article consists of analyzing a new high-tech anti-seismic control alternative for the construction of hospitals in Peru, which in its regulations requires the use of base insulation for essential buildings. For this, the structural evaluation of a building constructed with seismic isolators is chosen and the same with the implementation of the SLB (Shear Link Bozzo) energy dissipation system. The results analyzed for each anti-seismic control technique studied are: mezzanine drifts, floor accelerations, energy balance and analysis of plastic hinges, based on the philosophy of continuous functionality. / Trabajo de investigación
|
14 |
Influencia de los acelerogramas artificiales compatibles con el espectro de diseño sismorresistente peruano en la respuesta sísmica mediante un Análisis Tiempo Historia no lineal de una edificación multifamiliar de concreto armado en la ciudad de Lima / Influence of artificial accelerograms compatible with the Peruvian seismic design spectrum on the seismic response through a Nonlinear Time-History Analysis of a multifamily reinforced concrete building in the city of LimaCoronel Huanca, Dennys Luis, Mamani Rojas, Marcos Visney 02 August 2021 (has links)
La escasez de registros sísmicos de gran magnitud considerados significativos, limita la determinación de la respuesta sísmica de una edificación de concreto armado. En este sentido, los acelerogramas artificiales representan una alternativa para definir el evento sísmico porque consideran condiciones específicas del sitio en estudio. Esta investigación analiza la respuesta sísmica de las estructuras para diversos registros sísmicos artificiales generados de espectros de diseño para distintas condiciones geotécnicas. El procedimiento de análisis empleado será el dinámico tiempo historia no lineal para obtener una mayor precisión en la respuesta sísmica. Los resultados obtenidos muestran que las derivas de entrepiso de las señales artificiales creadas con la función de intensidad de Liu se ajustan mejor a las derivas obtenidas del sismo real escalado. / The lack of large seismic records in some world regions limits the determination of the seismic response of a building. For that reason, artificial accelerograms represent an alternative to define the seismic event because they consider specific conditions of study site. This research analyses the structures seismic response for various artificial seismic records generated from design spectra and different geotechnical conditions. Dynamic nonlinear time history analysing was used to obtain greater precision in the seismic response. The results obtained show that the mezzanine drifts of the artificial signals created with the Liu intensity function better fit the drifts obtained from the scaled real earthquake. / Tesis
|