• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 174
  • 57
  • 11
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 283
  • 140
  • 134
  • 127
  • 97
  • 86
  • 76
  • 70
  • 41
  • 39
  • 35
  • 31
  • 29
  • 28
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Reparação do tecido ósseo peri-implantar após enxerto ósseo autógeno e heterógeno: estudo experimental histológico em cães

De Santis, Enzo [UNESP] 05 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-05Bitstream added on 2014-06-13T21:04:26Z : No. of bitstreams: 1 desantis_e_dr_araca.pdf: 2787266 bytes, checksum: b11c83dbba262a0641d23d2d0ceb74da (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: avaliar a regeneração da crista óssea alveolar e o processo de osseointegração de implantes instalados em sítios enxertados com blocos de osso autógeno e osso bovino mineral (DBBM),associado a membrana de colágeno. Material e método: em 6 cães labradores foram extraidos os molares inferiores bilateralmente, nos quais foi removida a tábua óssea vestibular, criando-se um defeito em formato de caixa. Após 3 meses de regeneração, os retalhos foram elevados e posicionado um guia com uma lima endodôntica, com a finalidade de alinhar paralelamente à parede vestibular do defeito. O guia foi removido e, no lado direito inferior (grupo controle), foi obtido um enxerto ósseo do ramo ascendente da mandibula, que foi fixado a parede lateral do defeito por meio de parafusos. No lado esquerdo inferior (grupo teste), foi fixado um bloco de DBBM no defeito mandibular. Em ambos os lados, os blocos enxertados foram protegidos por uma membrana de colágeno reabsorvível. Em seguida os retalhos foram suturados. Após elevação do retalho, utilizou-se o guia para instalação de um implante de cada lado da mandíbula, entre o enxerto e o osso remanescente. Após 3 meses, os animais foram eutanasiados para obtenção das peças a serem processadas laboratorialmente para análise histológica. Resultados: Todos os implantes apresentaram-se clinicamente estáveis. A espessura da crista alveolar no grupo teste foi de 5.4, 9.4 e 9.3 mm, antes, imediatamente após a enxertia, e no momento da instalação dos implantes respectivamente. No grupo controle (enxerto ósseo autógeno), a espessura da crista alveolar foi de 5.2, 9.0 mm antes e imediatamente após o procedimento de enxertia (reconstrução). Após 3 meses... / Aim: - to evaluate the healing of the alveolar bony crest and the integration of implants installed in augmented sites with autologous bone or DBBM blocks, concomitantly with a collagen membrane. Material & methods: Mandibular molars were extracted bilaterally in 6 Labrador dogs, the buccal bony wall was removed and a box-shaped defect was created. After 3 months, flaps were elevated and a device was applied to a stent and used for the placement of an endodontic file that was lined up parallel to the buccal wall of the defect. The stent was removed and, in the right mandibular side, a bony graft was harvested from the ascending ramus and secured to the lateral wall of the defect by means of screws. In the left mandibular side, a DBBM block was fixed to the defect. A resorbable membrane was applied both sides. The flaps were sutured. After three months, one bone graft was exposed, and the dog was excluded from further analysis. After flap elevation, the stent and the device were used as guide to install one implant in each mandibular side, between the graft and the parent bone. After 3 months, biopsies were harvested and ground sections prepared for histological evaluation. Results: All implants were clinically stable. The width of the alveolar crest at the test sites was 5.4mm before, 9.4mm immediately after grafting, and 9.3mm at implant installation. At the control sites (autologous bone graft), the width of the alveolar crest was 5.2mm before and 9.0mm immediately after the grafting procedure. After 3 months of healing, the width was 8.7mm. One autologous bone block graft was lost before implant installation. All implants installed were available for histological evaluation (n=5). The autologous bone... (Complete abstract click electronic access below)
32

Regeneração óssea de defeitos circunferenciais criados cirurgicamente ao redor de implantes submersos. Estudo experimental em cães /

Rossi, Fabio. January 2011 (has links)
Orientador: Daniele Botticelli / Banca: Wilson Roberto Poi / Banca: Idelmo Rangel Garcia Júnior / Banca: Márcio de Moraes / Banca: Thaís da Silveira Rodrigues / Resumo: Objetivo: descrever o processo de reparo em defeitos marginais ao redor de implantes submersos 1mm abaixo ou acima da crista óssea. Estudo experimental em cães. Material e Métodos: Em 12 cães labradores, todos os pré-molares inferiores e primeiros molares foram extraídos bilateralmente. Três meses após as extrações, foi realizada a incisão sobre o rebordo e o descolamento dos retalhos de espessura total do lado direito da mandíbula. Foram preparados dois sítios cirúrgicos para instalação de implantes, com a região marginal alargada em 5mm de diâmetro para obtenção de um gap de 0,5 mm na região mesial (defeito pequeno) e um gap de 1,25 mm na região distal (defeito grande). Os parafusos de cobertura foram colocados aos implantes e os retalhos suturados para permitir um processo de cicatrização totalmente submerso. Posteriormente, foram realizados os mesmos procedimentos experimentais no lado esquerdo da mandíbula. O momento da realização dessas cirurgias e as eutanásias foram planejados de forma a se obter biópsias com 5, 10, 20, 30 dias de pósoperatórios. Após a eutanásia, os cortes histológicos foram processados laboratorialmente para análise histomorfométrica. Resultados: Aos 30 dias pós-operatório, os defeitos ósseos apresentaram-se parcialmente preenchidos por osso neoformado em todos os espécimes. A formação óssea ocorreu originando-se a partir da base do defeito e das paredes laterais. Um maior volume de osso neoformado foi observado nos defeitos grandes quando comparado aos pequenos. A maior parte de osso neoformado nos defeitos grandes formou-se entre o décimo e vigésimo dias de pósoperatórios. Entretanto, o contorno do osso neoformado localizou-se a uma distância similar da superfície do implante (aproximadamente 0,4 mm) em ambos os tipos de defeitos, no... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: to describe the healing of marginal defects below or above one millimeter of dimension around submerged implants in a dog model. Material and Methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two recipient sites were prepared and the marginal 5 mm were widened to such an extent to obtain, after implant installation, a marginal gap of 0.5 mm at the mesial site (small defect) and of 1.25 mm at the distal site (large defect). Titanium healing caps were affixed to the implants and the flaps were sutured allowing a fully-submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20, 30 days. Ground sections were prepared and histomorphometrically analyzed. Results: The filling of the defect with newly formed bone was incomplete after one month of healing in all specimens. Bone formation occurred from the base and the lateral walls of the defects. A larger volume of new bone was formed in the large compared to the small defects. Most of the new bone at the large defect was formed between the 10 and the 20-day period of healing. After one month of healing, the outline of the newly formed bone was, however, located at a similar distance from the implant surface (about 0.4 mm) at both defect types. Only minor newly formed bone in contact with the implant, starting from the base of the defects, was seen at the large defects (about 0.8 mm) while a larger amount was detected at the small defects (about 2.2 mm). Conclusion: Marginal defects around titanium... (Complete abstract click electronic access below) / Doutor
33

Efeito in vivo da deposição de filmes de DLC com e sem nanopartículas de prata sobre liga de titânio para utilização em próteses articulares /

El Abras Ankha, Milagros del Valle. January 2015 (has links)
Orientador: Yasmin Rodarte Carvalho / Co-orientador: Polyana Alves Radi Gonçalves / Banca: Luana Marotta Reis de Vasconcellos / Banca: José Renato Cavalcanti de Queiroz / Resumo: Materiais de revestimento duros para melhorar as propriedades biotribológicas das próteses articulares, estão sendo foco de pesquisa há algum tempo. Vários tipos de filmes de carbono têm sido descritos relatando falhas e sucessos e também sugerindo a necessidade de mais pesquisas. Frente a isso, este trabalho teve o objetivo de avaliar as características estruturais e de neoformação óssea de filmes de carbono tipo diamante com e sem nano-partículas de prata (DLC e DLC-Ag, respectivamente), aplicados por plasma (PECVD) em liga de titânio (Ti-6Al-4V). Sessenta amostras de Ti-6Al-4V, foram dividas em três grupos nos quais: 20 eram recobertas com filme de DLC, 20 com DLC-Ag e 20 sem recobrimento. Após a caracterização estrutural, as amostras foram fixadas bilateralmente no ângulo da mandíbula de 30 coelhos da raça Nova Zelândia. Após os períodos de 15 e 90 dias os animais foram eutanasiados e cinco amostras por grupo foram escolhidas aleatoriamente para a caracterização pósoperatória e cinco para análise qualitativa e quantitativa da neoformação óssea. Os dados foram tratados estatisticamente, por análise descritiva e inferencial, mediante o teste paramétrico ANOVA dois fatores de medidas repetidas e quando foi necessário o teste de comparação múltipla de Tukey (p<0,05%). Verificou-se que os filmes de DLC e DLC-Ag apresentaram alta resistência elétrica e não sofreram grandes modificações em seu espectro Raman, após os períodos de 15 e 90 dias. Na análise histológica após o período de 15 dias, observou-se trabéculas ósseas imaturas proliferando do osso preexistente em direção à amostra e, por vezes, recobrindo parcialmente a superfície da mesma. No período de 90 dias foi difícil delimitar a área de osso neoformado do preexistente, apresentando-se com as características de osso maduro e organizado, abrangendo a interface quase na sua totalidade, na maioria doos casos. Isto foi observado nos três.. / Abstract: Hard coating materials to improve the biotribologic properties of joint prostheses have been the focus of research for some time. Various types of carbon films have been described, reporting failures and successes and also suggesting the need for more research. Because of that, the aim of this work was to evaluate the structural characteristics and biocompatibility of diamond-like carbon films with and without nano-particles of silver (DLC and DLC-Ag, respectively), applied by plasma (PECVD) on a titanium alloy (Ti-6Al-4V). Sixty samples of Ti-6Al-4V, were divided into three groups in which 20 were coated with DLC film, 20 with DLC-Ag and 20 without coating. After the structural characterization, samples were fixed bilaterally in the mandible angle of 20 rabbits of New Zealand race. After periods of 15 and 90 days the animals were euthanized and five samples per group were randomly assigned to postoperative characterization and five for qualitative and quantitative analysis of new bone formation. The data were treated statistically, using descriptive and inferential analysis, by ANOVA parametric test two factors for repeated measures and when necessary, the multiple comparison test of Tukey (p<0.05%). It has been found that the DLC and DLC-Ag films showed high electrical resistance and did not suffer significant changes in its Raman spectrum after periods of 15 and 90 days. Histological examination after 15 days showed proliferating immature bone trabeculae, from the preexisting bone in the direction of the sample and .and sometimes partially covering its surface. At 90 days it was difficult delineate the newly formed bone area of the preexisting. Mature and organized bone was seen within the interface, comprising almost its entirety, in most cases. This was observed in all groups, confirming the results obtained in the histomorphometric analysis, there was no statistically significant ... / Mestre
34

Biocompatibilidade in vitro em amostras densas e porosas de titânio-35nióbio submetidas a tratamento biomimético /

Andrade, Dennia Perez de. January 2011 (has links)
Resumo: Titânio (Ti) é um dos melhores biomateriais para a confecção de implantes cirúrgicos, porém, estudos com novas ligas de Ti e variações da topografia visam otimizar os resultados da osseointegração. O objetivo deste estudo in vitro foi avaliar a biocompatibilidade de amostras densas e porosas da liga titânio- 35nióbio submetidas ou não ao tratamento biomimético, comparadas a amostras de Ti puro grau 2. As amostras foram divididas em 6 grupos (G): a) G1- Ti denso; b) G2 - Ti poroso; c) G3 - Ti poroso tratado; d) G4 - Ti-35Nb denso; e) G5 - Ti-35Nb poroso; f) G6 - Ti-35Nb poroso tratado. Células osteogênicas obtidas da calvária de ratos recémnascidos foram plaqueadas sobre as amostras e a adesão celular foi avaliada após 4 e 24 horas, enquanto a proliferação celular foi avaliada em 1, 3, 7 e 10 dias. A viabilidade foi avaliada em 1, 3, 7 e 10 dias. Para os demais testes as células foram cultivadas por 7, 10 e 14 dias. Após 14 dias, as culturas foram coradas com vermelho de Alizarina S para detecção dos nódulos de mineralização. As amostras foram caracterizadas por espectroscopia por dispersão de energia (EDS), difração de raio X (DRX), análise metalográfica e de rugosidade. Os dados da análise metalográfica foram submetidos ao teste de Kruskal Wallis e os dados das análises celulares foram comparados pelos testes Kruskal Wallis, Mann-Whitney e T-Student, (p<0,05). O EDS demonstrou a presença de íons sódio, fósforo, magnésio e cálcio nas amostras tratadas de ambos os grupos. O DRX demonstrou a presença dos metais titânio e nióbio na liga teste. A análise metalográfica demonstrou que as amostras porosas apresentavam poros interligados, com morfologia variada e a análise pelo rugosímetro demonstrou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium (Ti) is one of the best biomaterials for surgical implants fabrication. Studies with new titanium alloys and varied surface topographies seek for improved osseointegration results. The aim of the present in vitro study was to evaluate dense and porous titanium- 35 niobium alloys, submitted or not to biomimetic treatment in comparison to degree 2 pure titanium specimens. Specimens were divided into 6 groups (G): a) G1 - dense Ti; b) G2 - porous Ti; c) G3 - treated porous Ti; d) G4 - dense Ti-35Nb; e) G5 - porous Ti-35Nb and f) G6 - treated porous Ti-35Nb. Osteogenic cells from newborn rats calvarium were plated over the samples and cell adhesion assessed after 4 and 24 hours. Cell proliferation and viability were assessed at 1, 3, 7 and 10 days. Cells were cultured for 7, 10 and 14 days for further testings. Cell cultures were stained with Alizarin Red S after 14 days for mineralization nodules detection. Specimens were characterized by means of Energy Dispersion Spectrophotometry (EDS), X-Ray Diffraction (XRD), metallographic and profilometer analyses. Metallographic data were submitted to Kruskal Wallis, while cell analyses were assessed with Kruskal Wallis, Mann-Whitney and T-Student tests (P<0.05). EDS results detected the presence of sodium, phosphor, magnesium and calcium ions in treated specimens from both groups. XRD showed the presence of titanium and niobium for the test alloy. Metallographic analysis revealed interconnected pores and varied morphology within the porous specimens. Greater rugosity was detected by the profilometer analysis within the dense alloy specimens. In vitro tests revealed similar biocompatibility of Ti- 35Nb and degree 2 pure Ti. Porosity did not interfere, but in some scenarios improved alloy biocompatibility. The biomimetic treatment favor greater production... (Complete abstract click electronic access below) / Orientador: Yasmin Rodarte Carvalho / Coorientador: Carlos Alberto Alves Cairo / Banca: Débora Pallos / Banca: Adriana Aigotti Haberbeck Brandão / Banca: Renata Falchete do Prado / Banca: Maria Aparecida Neves Jardini / Doutor
35

Prótese protocolo com barra pré-fabricada : comportamento ósseo variando o tipo de osso e a configuração horizontal do arco mandibular no MEF-3D /

Almeida, Erika Oliveira de. January 2008 (has links)
Orientador: Eduardo Passos Rocha / Banca: Wirley Gonçalves Assunção / Banca: Marco Antonio Luersen / Resumo: A barra pré-fabricada é uma opção de tratamento vantajosa por minimizar o tempo de confecção da prótese implantossuportada do tipo protocolo de carga imediata com níveis de adaptação e passividade previsíveis. No entanto, para a sua aplicação, o arco do paciente deve adaptar-se anatomicamente ao formato da barra pré-fabricada, e a qualidade óssea deve ser compatível com a indicação da carga imediata. Além disso, a literatura não apresenta dados numéricos sobre a influência de diferentes formatos horizontais do arco mandibular na distribuição das tensões no osso, assim como não é homogênea a definição do critério de análise a ser utilizado quando materiais frágeis, como o osso, são estudados utilizando o método dos elementos finitos. Devido a isso, foi realizada uma revisão da literatura com o objetivo de relacionar as propriedades dos materiais estudados com o critério de análise adotado. Para isto, foram levantados 2061 artigos através do indexador Medline database, durante os anos de 2004 a 2008. Observou-se que tanto o critério das tensões de von Mises como a máxima tensão principal foram utilizados para o estudo dos materiais considerados frágeis ou não. Para o estudo da influência de diferentes formatos horizontais do arco mandibular e diferentes tipos de osso na distribuição das tensões no osso cortical e medular na simulação de uma prótese fixa implantossuportada do tipo protocolo mandibular confeccionada através do sistema pré-fabricado Neopronto (Neodent, Implante Osseointegrável), quatro modelos (M) representativos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Prefabricated bar is a profitable treatment option for minimizing the preparation time of fixed protocol-type prosthesis in immediate load with adaptation levels and predictable passivity. Nevertheless, in order to be applied, the patient's arch must be anatomically adapted to the format of the prefabricated bar, and bone quality must be compatible to immediate load indication. However, literature does not show any numerical data about the influence of different horizontal formats of the mandibular arch on bone stress distribution, as well as it is not homogeneous which analysis criterion is to be used when friable materials, such as the bone, are studied by making use of the finite element method. Due to this, a literature review was elaborated with the purpose to relate the materials' properties through the adopted analysis criterion. Therefore, 2061 articles were raised through the Medline Database Indexer from 2004 to 2008. It was noticed that not only Von Mises's equivalent stress criterion but also maximum principal stress were used for the study of materials considered as friable or not. For the study of the influence of different horizontal formats of mandibular archs and different types of bone in stress distribution on the cortical and medular bone in simulating a fixed implant-supported protocol-type mandibular prosthesis prepared through the Neopronto prefabricated system (Neodent, Osseointegratable Implant), four representative models (M) of a totally endentulate mandibular arch restored by the Neopronto prefabricated system (Neodent, Osseointegratable Implant) over four interforaminal implants were prepared through the SolidWorks 2007 program with a bone range (I to IV) (M.I - M.II - M.III - M.IV), considering the horizontal dimension as of regular size... (Complete abstract click electronic access below) / Mestre
36

Estudo da perda precoce de implantes osseointegraveis realizados na Faculdade de Odontologia de Piracicaba - Unicamp no periodo de julho de 1996 a julho de 2004 / Evaluation of early failure of dental implants performed at Piracicaba Dental School - Unicamp from july 1996 to july 2004

Sverzut, Alexander Tadeu, 1975- 23 February 2006 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T03:09:52Z (GMT). No. of bitstreams: 1 Sverzut_AlexanderTadeu_M.pdf: 2148820 bytes, checksum: 85cecee7cb4767985821dc5ca0bd831f (MD5) Previous issue date: 2006 / Resumo: As perdas de implantes dentários podem ser classificadas em precoces ou tardias segundo BUSER et al. (1991). Esse trabalho objetivou analisar a perda precoce de implantes dentários e os fatores de risco associados. Foram utilizados para análise os prontuários clínicos dos pacientes tratados pela Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba-Unicamp que foram submetidos à instalação de implantes dentários no período de julho de 1996 a julho de 2004. Foram selecionados pacientes submetidos à instalação de implantes osseointegráveis e que foram submetidos à segunda fase cirúrgica. As variáveis selecionadas para o estudo foram: gênero, idade, uso do tabaco, uso do álcool, protocolo de instalação de implantes, reconstruções prévias, comprimento do implante, diâmetro do implante, área de instalação do implante, tipo de superfície do implante, uso de contraceptivos orais, terapia de reposição hormonal, hipertensão arterial, hipotireoidismo, hipertireoidismo e diabetes. Foram catalogados 1403 prontuários sendo que 660 prontuários efetivamente foram utilizados no estudo. Foram instalados e analisados 1649 implantes, 62 destes sofreram perda precoce. Os dados coletados foram analisados através de estatística univariada e regressão logística multivariada, demonstrando a significância e o fator de risco quanto à perda precoce de implantes dentários. De acordo com a metodologia empregada a conclusão do estudo foi que a infecção precoce é o maior fator de risco relacionado à perda precoce de implantes dentários, aumentando em 44 vezes chance de falha relacionadas a implantes que não apresentaram nenhum tipo de infecção, implantes curtos 6-9mm exibem um fator de risco quanto à perda precoce 4 vezes maiores que implantes com comprimentos maiores e processos reconstrutivos prévios, condições sistêmicas, vícios, gênero, idade, não influenciam a perda precoce de implantes / Abstract: Dental implant failures can be classified in early or delayed, according to BUSER et al. (1991). The purpose of this study was to evaluate the risk factors related to early loss of dental implants. The clinical files of all patients subjected to the installation of dental implants in the Oral and Maxillofacial area, Piracicaba Dental School, State University of Campinas, in the period from 1996 to 2004, were analyzed. The inclusion criterion was the installation of dental implants in patients that had been subjected to the second surgical phase. The selected variables were: gender, age, tobacco use, alcohol use, implant installation protocol, previous reconstructive procedures, implant length, implant width, area of installation of the implants, implant surface, hormonal contraceptive use, hormone reposition therapy, arterial hypertension, hypothyroidism, hyperthyroidism and diabetes. A total of 1403 files were evaluated and 660 could be used in the study. A number of 1649 implants were installed and analyzed, and 62 of them had suffered early loss. The collected data were analyzed through univariate statistics and multivariate logistic regression, showing the significance and risk factors for early loss of dental implants. According to the employed methodology, it could be concluded that early infection is the main factor of risk related to early dental implant loss, increasing in 44 times the failure possibility when compared to implants without any type of infection; short implants (6-9mm) increase the risk of early implant loss in 4 times. Narrow implants presented significance for early loss, but are not considered risk factors. Previous reconstructive procedures, systemic conditions, addictions, gender and age did not present statistical significance and are not risk factors for early loss of dental implants / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
37

Analyzes of the surface integrity of dental implants and the influence of nitriding and amino-functionalization treatments on osteogenesis = Análises da integridade da superfície de implantes dentais e da influência dos tratamentos de nitretação e amino-funcionalização na osteogênese / Análises da integridade da superfície de implantes dentais e da influência dos tratamentos de nitretação e amino-funcionalização na osteogênese

Senna, Plinio Mendes, 1984- 24 August 2018 (has links)
Orientador: Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T02:20:50Z (GMT). No. of bitstreams: 1 Senna_PlinioMendes_D.pdf: 3337065 bytes, checksum: ab1604c24cecde50c75c962908b8301b (MD5) Previous issue date: 2013 / Resumo: Os implantes dentais recebem diversos tratamentos para criar micro- e nano-estruturas na superfície, aumentando a área de contato com o osso e favorecendo a osseointegração. O objetivo deste trabalho foi quantificar por meio de parâmetros de rugosidade as alterações de superfície causadas pelo processo de inserção no tecido ósseo e investigar a presença de partículas soltas de titânio na interface osso-implante (Capítulo 1); avaliar a influência do tratamento de nitretação por plasma nas propriedades de superfície do titânio e na sua biocompatibilidade (Capítulo 2); e avaliar a adsorção de proteínas in vitro e a osteogênese ao redor de implantes amino-funcionalizados instalados em coelhos (Capítulo 3). No Capítulo 1, a rugosidade de três grupos de implantes representando differences geometrias e tratamentos de superfície foi avaliada por interferometria antes e após a inserção dos mesmos em blocos de costela bovina. Os blocos também foram avaliados por microscopia para identificar partículas de titânio presentes na interface. A amplitude de todos os parâmetros de rugosidade das superfícies dos implantes foram menores após a inserção para todos os grupos e as imagens microscópicas revelaram a presença de partículas de titânio a alumínio na interface, concentradas principalmente no nível do osso cortical. Assim, concluiu-se que as superfícies moderadamente rugosas podem gerar partículas soltas de titânio na interface. No Capítulo 2, discos de titânio (12,7 × 2 mm) moderadamente rugosos foram nitretados por plasma a frio. Osteoblastos humanos (SAOS-2) foram cultivados sobre os discos por 1, 3, 5 e 7 dias. A proliferação e diferenciação celular foram avaliadas por MTS, produção de fosfatase alcalina e por qPCR. Foi observado, que a nitretação aumentou a quantidade de nitrogênio na superfície, além da dureza, molhabilidade e nanoestruturas. Não houve diferença no comportamento célular em relação ao grupo não nitretado. Assim, concluiu-se que a nitretação por plasma a frio aumentou a dureza da superfície e não prejudicou a biocompatibilidade do titânio. No Capítulo 3, o titânio foi aminofuncionalizado com 3-aminopropiltrietoxisilano. O perfil protéico adsorvido foi avaliado por espectrometria de massas após discos serem imersos em plasma sanguíneo humano por 3 h. Para a análise da osteogênese, implantes de titânio (3,75 × 6 mm) receberam o mesmo tratamento e foram instalados em 10 coelhos New Zealand adultos (1 na metáfise distal do fêmur e 2 na metáfise proximal da tíbia de ambas as patas). Os animais foram sacrificados após 3 e 6 semanas e os implantes e osso adjacente foram coletados, fixados e incluídos em blocos de resina. Em seguida, lâminas de 20 ?m de espessura foram preparadas na região central de cada implante e coradas com azul de toluidina. A análise histomorfométrica compreendeu a mensuração da área de contato osso-implante. A superfície tratada apresentou maior quantidade total de proteínas adsorvidas; no entanto, com menor abundância relativa de fibronectina. Não houve diferença para a área de contato osso-implante entre os dois grupos de implantes após 3 e 6 semanas. Assim, concluiu-se que a amino-funcionalização aumentou a quantidade de proteínas adsorvidas, mas não foi efetiva para acelerar a osteogênese. / Abstract: Dental implants receive surface treatments to create micro- and nanostructures on surface to increase the contacting area with bone, which favors osseointegration. However, the resistance of these structures in face of the friction against the bone tissue during the implant insertion is not evaluated yet. Thus, the objective in this study was to quantify by means of roughness parameters the surface wear caused by the insertion procedure in the bone tissue and to investigate the presence of loose titanium particles at bone-implant interface (Chapter 1); to evaluate the influence of plasma nitriding treatment on surface properties of titanium and on its biocompatibility (Chapter 2); and to investigate the protein adsorption in vitro and osteogenesis around amino-functionalized implants placed in rabbits (Chapter 3). In Chapter 1, roughness of three implants representing different geometries and surface treatments were evaluated by interferometry before and after insertion into bovine rib blocks. The blocks were also evaluated by microscopy to identify titanium particles at the interface. The amplitude of all roughness parameters were smaller after the insertion procedure for all implant groups and microscopic images revealed presence of loose titanium and aluminum particles at the interface, concentrated at the cortical crest. Therefore, it was concluded that moderately rough surfaces can release loose particles at the interface. In Chapter 2, titanium discs (12.7 × 2 mm) with moderately rough surface were nitrided by cold plasma. Human osteoblasts (SAOS-2) were cultivated on the discs for 1, 3, 5 and 7 days. Cell proliferation and differentiation were evaluated by MTS, production of alkaline phosphatase and by qPCR. It was observed that plasma nitriding increased the nitrogen content on surface, and also hardness, wettability and nanostructures. No significant difference between titanium and nitrided surface was seen on cell behavior. Therefore, it was concluded that nitriding treatment increase surface hardness and does not jeopardize the biocompatibility of titanium. In Chapter 3, titanium was amino-functionalized by 3-aminopropyltriethoxysilane. Protein profile was identified by mass spectroscopy after discs were immersed in human blood plasma for 3 h. To evaluate osteogenesis, titanium implants (3.75 × 6 mm) were placed in 10 New Zealand adult rabbits (1 in the femoral distal metaphysis and 2 in the tibial proximal metaphysis of both legs). The animals were sacrificed after 3 and 6 weeks and implants with adjacent bone were collected, fixed and included in resin blocks. After, 20 ?m thick slides were prepared at the central region of each implant and stained by toluidine blue. Histomorphometric analysis consisted of measuring the bone-to-implant contact (BIC). Treated surface exhibited higher amount of adsorbed proteins; however, lower relative abundance of fibronectin. No significant difference was identified between the groups for BIC values after 3 and 6 weeks. Therefore, amino-functionalization enhance protein adsorption but has no effect on early bone formation. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
38

Tratamento químico e térmico em Ti-cp visando a formação de uma superfície bioativa para otimização da osseointegração /

Oliveira, Marcelo Gabriel de. January 2019 (has links)
Orientador: Adriano Alves dos Reis / Coorientadora: Polyana Alves Radi Gonçalves / Banca: Marcos Yutaka Shiino / Banca: Maria Margareth da Silva / Resumo: Embora o titânio e suas ligas sejam amplamente utilizados como materiais de implante, estudos para acelerar a osseointegração têm sido realizados. Uma das técnicas em estudo é o tratamento alcalino e térmico. Este trabalho tem como objetivo avaliar a formação de uma superfície bioativa em titânio comercialmente puro grau 4 após tratamento alcalino e térmico a 600 °C e 900 °C. Técnicas de caracterização via MEV, AFM, Raman, DRX, molhabilidade, nanoindentação e aderência à indentação foram realizadas para avaliar modificações superficiais e na seção transversal além disso, teste in vitro via imersão em SBF (fluido corporal simulado) para avaliar o crescimento de apatita. O tratamento alcalino formou hidrogenotitanato de sódio (1 µm de espessura) e o tratamento alcalino e térmico formou titanato de sódio (1 µm de espessura), enquanto o rutilo (TiO2) aumentou com o aumento da temperatura do tratamento, atingindo até 5 µm de espessura. A superfície passou de ligeiramente hidrofílica para totalmente hidrofílica. A rugosidade e a área de superfície aumentaram, especialmente em tratamento alcalino e térmico a 900 °C. A dureza da camada superficial aumentou significativamente com o tratamento térmico, e a aderência da indentação mostrou que o tratamento alcalino e térmico a 900 °C apresenta maior delaminação da superfície. Testes in vitro confirmaram que o tratamento alcalino e térmico acelera o crescimento da apatita, mas que o tratamento alcalino e térmico a 600 °C é o tratamento qu... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Although titanium and its alloys are widely used as implant materials, studies for rapid osseointegration have been performed. One of the techniques currently in study is the alkali and heat treatment. This work aims to evaluate the formation of a bioactive surface in titanium commercially pure grade 4 after alkali and heat treatment at 600 °C and 900 °C. Characterization techniques via SEM, AFM, Raman, XRD, wettability, nanoindentation and indentation adhesion were performed to evaluate surface and cross sectional modifications. In addition, in vitro test via SBF (simulated body fluid) soaking was performed to evaluate apatite growth. Alkaline treatment formed sodium hydrogen titanate (1 μm thick), and alkali and heat treatment formed sodium titanate (1 μm thick), while rutile TiO2 increased with increasing treatment temperature, reaching up to 5 μm thick. The surface went from slightly hydrophilic to fully hydrophilic. Roughness and surface area increased, especially in alkali and heat treatment at 900 °C. The hardness of the surface layer was significantly increased by the heat treatment, and the indentation adhesion showed that the alkali and heat treatment at 900 °C presented higher surface delamination. In vitro tests have confirmed that alkali and heat treatment accelerate apatite growth, but that alkali and heat treatment at 600 ° C is the treatment that has the highest mechanical strength and is best suited to accelerate osseointegration. / Mestre
39

Retrospective review of pre surgical variables associated with marginal bone loss measured at 2nd stage abutment surgery for endosseous dental implants

Mancuso, Vanessa Lynn 15 June 2023 (has links)
AIM: To measure marginal bone loss around endosseous dental implants at 2nd stage abutment surgery and retrospectively evaluate the association of pre-surgical variables with bone findings. MATERIALS AND METHODS: Two implant systems were included in the study design. Straumann Bone Level Tapered SLActive and Nobel Biocare Replace Conical Connection. Implants were placed by the same resident from the Periodontics department. Clinical measurements of bone level were recorded at the time of placement and then again at 2nd stage surgery at four different points (mesial, lingual, buccal, distal). RESULTS: Five implants were evaluated in the study. Bone loss averages ranged from 0-1.0mm. Nobel implants had an average loss of .75mm and Straumann implants had an average loss of .67mm. CONCLUSION: Many variables contribute to marginal bone loss around endosseous dental implants at 2nd stage abutment surgery. The current research was designed to understand the relationship between these variables and early marginal bone loss. All implant samples included here were defined as control because of ≤1.0mm bone loss per IRB protocol.
40

Histomorphometric and Biomechanical Analyses of Osseointegration of Four Different Orthodontic Mini Implant Surfaces

Yadav, Sumit January 2011 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Objective: To evaluate the osseointegration potential of four different surfaces of mini-implants .We hypothesized that mini-implants surface roughness alters the intrinsic biomechanical properties of the bone integrated to titanium. Materials and Methods: Mini implants and circular discs were made from alloy Ti6Al4V grade 5. On the basis of surface treatment study was divided into 4 groups: Group 1: Machined: no surface treatment, Group 2: Acid etched: with hydrochloric acid, Group 3: Grit Blasted with alumina and Group 4: Grit blasted +Acid etched. Surface roughness parameters (mean surface roughness: Ra and Quadratic Average roughness: Rq) of the four discs from each group were measured by the optical profilometer. Contact angle measurement of 3 discs from each group was done with a Goniometer. Contact angle of liquids with different hydrophobicity and hydrophilicity were measured. 128 mini implants, differing in surface treatment, were placed into the tibias and femurs of 8 adult male New Zealand white rabbits. Biomechanical properties (Removal torque and hardness) measurements and histomorphometric observations were measured. Results: Ra and Rq of groups were: Machined (1.17±0.11, 2.59±0.09) Acid etched (1.82±0.04, 3.17±0.13), Grit blasted (4.83±0.23, 7.04±0.08), Grit blasted + Acid etched (3.64±0.03, 4.95±0.04) respectively. Group 4 had significantly (p=0.000) lower Ra and Rq than Group 3. The interaction between the groups and liquid was significant. Group 4 had significantly lower contact angle measurements (40.4°, 26.9°), both for blood and NaCl when compared to other three groups (p≤0.01). Group 4 had significantly higher torque than Group 3 (Tibia: 13.67>9.07N-cm; Femur: 18.21>14.12N-cm), Group 4 (Tibia: 13.67>9.78N-cm; Femur: 18.21>12.87N-cm), and machined (Tibia: 13.67>4.08N-cm; Femur: 18.21>6.49N-cm). SEM analysis reveals significantly more bone implant gap in machined implant surfaces than treated implant surfaces. Bone to implant contact had significantly higher values for treated mini implant surface than machined surface. Hardness of the bone near the implant bone interface is 20 to 25% less hard than bone 1mm away from it in both Femur and Tibia. Conclusion: Surface roughness and wettability of mini implants influences their biological response. Grit blasted and acid etched mini implants had lowest contact angle for different liquids tested and highest removal torques.

Page generated in 0.026 seconds