• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 80
  • 2
  • 2
  • 1
  • Tagged with
  • 85
  • 85
  • 85
  • 57
  • 50
  • 30
  • 27
  • 22
  • 21
  • 16
  • 15
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Avaliação in vitro da capacidade seladora e da qualidade da obturação de quatro cimentos endodônticos utilizando a técnica do cone único / In vitro evaluation of sealing-ability and obturation quality of four endodontic sealers using the single cone obturation technique

Pablo Andres Amoroso Silva 10 May 2013 (has links)
O objetivo deste trabalho foi avaliar o selamento apical em 7 e 30 dias de, obturações de canais radiculares com a técnica de cone único utilizando 4 cimentos endodônticos, AH Plus, MTA Fillapex, cimento Portland, e cimento experimental Sealepox, por meio do sistema de infiltração de fluidos FLODEC, e a qualidade de obturação, em microscopia confocal a laser, analisando o perímetro de penetração dos cimentos nos túbulos dentinários, e a porcentagem de fendas na interface cimento/dentina, e por meio de estereomicroscopia, a porcentagem de cimento, guta-percha e espaços vazios a 2,4 e 6mm do ápice radicular, dos cimentos. Sessenta e oito dentes unirradiculados, com canais únicos tiveram seus canais instrumentados e, então, obturados com os cimentos, previamente corados com Rodamina B. As amostras foram conservadas em meio úmido a 37º de temperatura. Após 7 dias, os dentes foram adaptados para os testes de infiltração de fluidos, fazendo-se as leituras durante 12 minutos constantes, para todos os espécimes. Trinta dias depois, as leituras foram realizadas novamente com os mesmos parâmetros anteriores. Todos os espécimes foram cortados em secções de 2mm de espessura nos níveis de 2,4 e 6mm do ápice radicular. Mediante estereomicroscopia, foram calculadas as porcentagens de cimento, guta-percha e espaços vazios, e em microscopia confocal, as porcentagens de fendas e o perímetro de penetração dos cimentos no interior dos túbulos dentinários, em todas as secções. Os resultados obtidos mostraram que, todos os cimentos permitiram a infiltração de fluidos em 7 dias, sendo que, o MTA Fillapex exibiu, significativamente, menor infiltração que os cimentos AH Plus e Portland. Em 30 dias não houve diferenças estatísticas entre os cimentos. Nas avaliações em microscopia confocal, observou-se a presença de fendas na interface dentina/cimento em todas as secções avaliadas. À estereomicroscopia observaram-se espaços vazios em todas as secções, bem como, variações nas porcentagens de cimento e guta-percha. / The aim of this study was to evaluate sealing-ability at 7 and 30 days of root canal obturations using a single cone obturation technique of 4 endodontic sealers, AH Plus, Mta Fillapex, Portland Cement and a experimental sealer Sealepox, using a fluid filtration recording device (FLODEC), to evaluate the obturation quality using confocal laser microscopy analyzing interfacial adaptation of sealer/dentin interface, perimeter of sealer penetration into dentinal tubules, and using stereomicroscopy, the percentage of sealer, guta-percha and voids at 2, 4 and 6mm from de apex. Sixtyeight single rooted teeth with one canal were instrumented and then, obturated, with the sealers, in which, Rodamine B was previously added. Samples were stored in 100% humidity and at 37º temperature. After 7 days, all the specimens were submitted to microleakage tests for a 12-minute period. Mta Fillapex showed the lowest leakage percentage when compared with AH Plus and Portland cement. 30 days after the first test, microleakage evaluations were repeated, and the results showed no statistical differences. Then, all samples were cut horizontally of 2mm of thickness at 2,4,6mm from the apex. Using estereomicrocopy, percentage of sealer, guta-percha and voids were measured, and using confocal laser microscopy percentages of interfacial adaptation and perimeter of sealer penetration into dentinal tubules were calculated. According to the results it was concluded that all sealers permitted fluid filtration at 7 and 30 days, being that, at 7 days, MTA Fillapex exhibited significantly, less fluid filtration than AH Plus and Portland Cement. At 30 days, no statistically differences were found. On confocal evaluations, it was observed the presence of gaps at the sealer/dentin interface in all evaluated sections. Stereomicroscopy assessments showed voids in all sections and as well variations on sealer and guta-percha percentages.
62

Análise em microtomografia computadorizada do preparo e obturação em canais mesiais de molares inferiores /

Pinto, Jáder Camilo. January 2018 (has links)
Orientador: Mário Tanomaru Filho / Resumo: Objetivo: Avaliar preparo e dilatação adicional com instrumentos de NiTi tratados termicamente em movimento rotatório ou reciprocante, capacidade de preenchimento pelas técnicas de onda contínua de condensação (OCC) ou compactação lateral (CL) e por OCC com cimentos AH Plus (AHP) ou Neo MTA Plus (NMTAP) em raízes mesiais de molares inferiores. Metodologia: Molares inferiores com dois canais radiculares e curvatura entre 20° e 40° foram preparados (n=24) por ProDesign Logic (PDL) 25.01 e 25.06 em movimento rotatório e ProDesign R (PDR) 25.06 em movimento reciprocante. Dilatação adicional foi realizada com PDL35.01 e PDL35.05 ou PDR35.05. Canais preparados por PDL35.05 foram obturados (n=12) por CL ou OCC, associados a AHP. Canais preparados por PDR35.05 foram obturados por OCC e AHP ou NMTAP. Escaneamentos com 9 µm foram realizados com Micro-CT (SkyScan 1176) antes e após o preparo, após a dilatação adicional e após a obturação. Percentual de aumento volumétrico (%AV), debris (%D) e superfície não instrumentada (%SNI), transporte, centralização e tempo de preparo foram analisados. Análises volumétricas foram realizadas para determinação do percentual de material obturador e de falhas como um todo e em cada terço dos canais radiculares. Os testes estatísticos ANOVA e Tukey ou Kruskall-Wallis e Dunn foram realizados (P<0,05). Publicação 1 - Resultados: PDL25.06 promoveu maior %AV no terço apical e menor %D e %SNI em comparação ao PDR25.06 (P<0,05). Após dilatação adicional PDL35... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Introduction: The aim of this study was to evaluate root canal preparation and additional enlargement using NiTi instruments thermally treated in rotary or reciprocating motion, filling capacity by continuous wave of condensation (CWC) or lateral compaction (LC) and CWC using AH Plus (AHP) or Neo MTA Plus (NMTAP) in mesial roots of mandibular molars. Methods: Mesial roots of mandibular molars, degree of curvature between 20° and 40°, were prepared (n=24) by ProDesign Logic (PDL) 25.01 and 25.06 in rotating motion or ProDesign R (PDR) 25.06 in reciprocating motion. Additional enlargement was performed using PDL 35.01 and 35.05 or PDR 35.05. Root canals prepared by PDL 35.05 were filled (n=12) by LC or CWC, associated with AHP. Root canals prepared by PDR 35.05 were filled by CWC associated with AHP or NMTAP. Scanning with 9μm resolution were performed by Micro-CT (SkyScan 1176) before and after preparation, after additional enlargement and after filling. Percentage increase in volume (%VI), debris (%D) and uninstrumented surface (%US), root canal transportation, centralization and preparation time were analysed. Volumetric analyzes were performed to determine the percentage of obturator material and voids as a whole and in each third of the root canals. ANOVA and Tukey or Kruskal-Wallis and Dunn tests were used (α=0.05). Publication 1 - Results: PDL 25.06 promoted higher %VI in the apical third and lower %D and %US compared to PDR 25.06 (P<0.05). After additional enlargement, ... (Complete abstract click electronic access below) / Mestre
63

Preparo e obturação de canais distais achatados de molares inferiores : análise por microtomografia computadorizada /

Santos Júnior, Airton Oliveira. January 2020 (has links)
Orientador: Juliane Maria Guerreiro Tanomaru / Resumo: Objetivo: Avaliar o preparo com instrumentos de níquel-titânio tratados termicamente em movimento rotatório ou reciprocante e a associação com inserto ultrassônico e capacidade de preenchimento pelas técnicas híbrida de Tagger ou cone único empregando o cimento Bio-C Sealer em canais radiculares achatados. Metodologia: Canais distais achatados de molares inferiores com diâmetro vestíbulo-lingual igual ou maior que 4 vezes o diâmetro mésio-distal foram preparados (n=12) por Reciproc Blue (RB) R40 em movimento reciprocante ou ProDesign Logic (PDL) 40.01 e 40.05 em movimento rotatório. Etapa complementar de instrumentação foi realizada com inserto ultrassônico Flatsonic nos dois grupos. Os canais foram obturados (n=12) pela técnica híbrida de Tagger ou cone único com o cimento Bio-C Sealer. Escaneamentos em resolução de 8,74 µm foram realizados em microtomografia computadorizada (micro-CT) antes e após todas as etapas experimentais. Percentual de aumento volumétrico, debris e superfície não instrumentada foram analisados para as etapas de preparo e percentual de falhas para obturação. Testes estatísticos ANOVA e Tukey, teste t pareado e não pareado foram realizados com nível de significância de 5%. Publicação 1 – Resultados: O percentual de aumento volumétrico, debris e superfície não instrumentada foi semelhante entre RB e PDL na extensão total do canal (P>0,05). PDL promoveu menor percentual de debris no terço cervical e menor percentual de aumento volumétrico no terço apical ... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
64

Análise por microtomografia computadorizada do preparo e obturação de canais radiculares achatados de segundos pré-molares superiores /

Tavares, Karina Ines Medina Carita. January 2020 (has links)
Orientador: Mario Tanomaru Filho / Resumo: Objetivo: Avaliar o preparo empregando dois sistemas rotatórios de níquel-titânio tratados termicamente e efeito do novo inserto ultrassônico e instrumento de menor diâmetro e a capacidade de preenchimento dos cimentos Bio-C Sealer ou AH Plus pela técnica de cone único em canais radiculares achatados de segundos pré-molares superiores. Metodologia: Canais radiculares achatados de segundos pré-molares superiores humanos com diâmetro vestíbulo-lingual igual ou maior que 4 vezes o diâmetro mésio-distal foram preparados com sistemas rotatórios(n=16): ProDesign Logic (PDL) 30.01 e 30.05 ou HyFlex EDM (HEDM) 10.05 e 25.08. Etapa do preparo complementar foi realizada com inserto ultrassônico Flatsonic (terço cervical e médio) e PDL 25.03 (terço apical) (FPDL) em ambos os grupos. Os canais radiculares foram obturados (n=16) com o cimento Bio-C Sealer ou AH Plus pela técnica de cone único. Escaneamentos em resolução de 8,74 µm foram realizados em microtomografia computadorizada (micro-CT) antes e após as etapas experimentais. Percentual de aumento volumétrico, debris e superfície não instrumentada foram analisados para as etapas de preparo e percentual de falhas para obturação. Os testes estatísticos específicos para o preparo e obturação foram realizados com nível de significância de 5%. Publicação 1 – Resultados: Não houve diferença estatística entre PDL e HEDM para o aumento de volume, debris e superfície não instrumentada no canal como um todo (P>0,05). PDL obteve maior percentual... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study was to evaluate root canal preparation using two rotary nickel-titanium systems thermally treated and the effect of ultrasonic tip and small diameter instrument; and the filling capacity of sealers Bio-C Sealer and AH Plus by single cone technique in flattened root canals of maxillary second premolars. Methods: Flattened root canals of human maxillary second premolars with buccolingual diameter 4 or more times larger than the mesiodistal diameter were prepared with rotary systems (n=16): ProDesign Logic (PDL) 30.01 e 30.05 or HyFlex EDM (HEDM) 10.05 e 25.08. Complementary preparation step was performed with ultrasonic tip Flatsonic (cervical and middle thirds) and PDL 25.03 (apical third) (FPDL) in both groups. The root canals were filled (n=16) with Bio-C Sealer or AH Plus by single cone technique. Scanning in resolution of 8,74 µm were performed by microcomputed tomography (micro-CT) before and after the experimental steps. Percentage of increase in volume, debris and uninstrumented surface were analysed for the preparation steps and percentage of voids for obturation. The statistical tests specific to preparation and obturation analyses were performed with a significance level of 5%. Publication 1 - Results: There was no statistically difference between PDL and HEDM for volume increase, debris and uninstrumented surface, in entire canal (P>0,05). PDL showed higher debris in the middle and apical thirds than HEDM (P<0,05). The FPDL protocol ... (Complete abstract click electronic access below) / Mestre
65

Propriedades físico-químicas e citotoxicidade de materiais obturadores de canais radiculares de dentes permanentes / Physicochemical properties and cytotoxicity of root canal filling materials of permanent teeth

Marques, Fernanda Vicioni 06 June 2018 (has links)
O presente estudo teve como objetivo avaliar as propriedades físico-químicas e citotoxicidade quatro cimentos endodônticos, com diferentes bases químicas, utilizados na rotina clínica do Cirurgião-dentista. Foram utilizados os cimentos AH Plus®, BioRoot RCS®, Endomethasone N® e Sealapex®. Foram realizados os testes físico-químicos de tempo de endurecimento, radiopacidade e escoamento, segundo a especificação nº 57 da ANSI/ADA (2012). Para o teste de citotoxicidade, foram coletadas amostras sanguíneas de seis doadores voluntários adultos, com idade entre 18 e 35 anos, de ambos os gêneros. Foi realizada a cultura de células primárias de linfócitos do sangue periférico humano em contato com o eluato dos cimentos obturadores, e a viabilidade celular foi analisada por meio do ensaio de MTT. Cada teste foi realizado em triplicata, tanto para propriedades físico-químicas como para o ensaio do MTT, sendo os resultados analisados empregando o programa GraphPad Prism 5®, por meio do teste Oneway ANOVA e pós-teste de Tukey, com nível de significância de 5%. De acordo com os resultados obtidos, tanto o AH Plus® quanto o BioRoot RCS® apresentaram tempo de endurecimento de 1450 minutos e 255 minutos, respectivamente; Endomethasone N® não tem tempo de endurecimento citado pelo fabricante, e Sealapex® não tomou presa no período do estudo (168 horas). Para o teste de radiopacidade, todos os materiais avaliados apresentaram radiopacidade acima de 3 mm alumínio, como recomendado pela especificação nº 57 da ANSI/ADA (2012). Para o teste de escoamento, segundo a ISO 6876:2012, um cimento endodôntico não deve apresentar um diâmetro inferior a 17 mm. Observamos a maior média para AH Plus® (39,68 mm), seguido em ordem decrescente por Sealapex® (35,73 mm), Endomethasone N® (34,22 mm) e BioRoot RCS® (23,81 mm). Quanto à viabilidade celular, Endomethasone N® foi citotóxico sobre os linfócitos em todas as concentrações (p<0,05). Sealapex® apresentou menor viabilidade celular na diluição de 1:32 (3,125mg/mL) (p<0,05). AH Plus® e BioRoot® não demonstrou citotoxicidade em nenhuma das concentrações avaliadas (p>0,05). Podemos concluir que todos os materiais avaliados atenderam aos parâmetros estabelecidos pela ANSI/ADA para os testes físico-químicos realizados. Além disso, o Endomethasone N® apresentou citotoxicidade sobre os linfócitos humanos, e os demais materiais analisados apresentaram viabilidade celular em níveis aceitáveis / The present study had as objective to evaluate the physicochemical properties and cytotoxicity of four root canal sealers with different chemical bases, used in the clinical routine of the Dentistry. The AH Plus®, BioRoot RCS®, Endomethasone N® and Sealapex® cements were used. The physicochemical tests of setting time, radiopacity and flowability were performed according to ANSI/ADA specification (nº 57). For the cytotoxicity test, blood samples were collected from six adult voluntary donors, aged 18-35 years, of both genders. Primary human lymphocyte cell cultures were placed in contact with the eluate from the plug cements, and cell viability was analyzed by the MTT assay. Each test was performed in triplicate, both for physicochemical properties and for the MTT assay. The results were analyzed using the GraphPad Prism 5® program, using the Oneway ANOVA test and Tukey\'s post-test, with a significance level of 5%. According to the results obtained, both AH Plus® and BioRoot RCS® presented setting time of 1450 minutes and 255 minutes, respectively; Endomethasone N® does not have setting time quoted by the manufacturer, and Sealapex® did not set in the study period (168 hours). For the radiopacity test, all evaluated materials had radiopacity above 3 mm aluminum, as recommended by the ANSI/ADA specification (nº 57). For the flow test, according to ISO 6876:2012, an endodontic cement must not have a diameter of less than 17mm. We observed the highest mean for AH Plus® (39.68 mm), followed in descending order by Sealapex® (35.73 mm), Endomethasone N® (34.22 mm) and BioRoot RCS® (23.81 mm). Regarding cell viability, Endomethasone N® was cytotoxic on lymphocytes at all concentrations (p <0.05). Sealapex® presented lower cell viability at 1:32 dilution (3.125 mg / mL) (p <0.05). AH Plus® and BioRoot® showed no cytotoxicity at any of the concentrations evaluated (p> 0.05). We can conclude that all materials evaluated met the parameters established by ANSI/ADA for the physicochemical tests performed. In addition, Endomethasone N® showed cytotoxicity on human lymphocytes, and the other materials analyzed presented cell viability at acceptable levels
66

Avaliação da resposta inflamatória periapical resultante da infiltração coronária em dentes de cães obturados com diferentes cimentos resinosos e técnicas obturadoras / Evaluation of periapical inflammation response from coronal leakage in dog´s teeth obturated using different resin-based sealers and different obturation techniques

Akisue, Eduardo 14 April 2009 (has links)
Considerando-se a necessidade da obturação tridimensional e o adequado selamento marginal do sistema de canais radiculares, como fatores decisivos para o êxito da terapia endodôntica, este estudo objetivou avaliar as respostas inflamatórias periapicais resultantes da infiltração coronária em dentes de cães obturados com diferentes cimentos resinosos (AH Plus®, RealSeal® e RealSeal SE®) e técnicas obturadoras (condensação lateral e termoplástica). Para tanto, pré-molares e incisivos centrais e laterais de 5 cães tiveram o tratamento endodôntico realizado empregando-se limas de NiTi e creme de Endo PTC associado ao hipoclorito de sódio a 1%, estabelecendo-se como limite de instrumentação à distância de 1mm a 1.5mm aquém do vértice radiográfico. A seguir os condutos foram obturados de acordo com os grupos experimentais (n=12) e grupos controles (n=10): GI- AH Plus/condensação lateral, GII- AH Plus/termoplástificação, GIIIRealSeal/ condensação lateral, GIV- RealSeal/ termoplástificação, GV- RealSeal SE/condensação lateral, GVI- RealSeal SE/ termoplástificação, Grupo controle positivo e Grupo controle negativo. As cavidades coronárias ficaram expostas ao meio bucal por um período de 75 dias e, passado este período experimental, os cães foram eutanásiados por superdosagem de anestésico. Foi realizada a remoção cirúrgica das partes correspondentes aos pré-molares e incisivos da maxila e da mandíbula, fixação das mesmas em solução de formol a 10% por 72h e desmineralização em solução de ácido fórmico a 20% + citrato de sódio a 10% pelo período mínimo de 90 dias. Posteriormente, realizou-se a rotina histológica com cortes seriados com espessura de 6m e estes foram corados com hematoxilina e eosina (HE). Cada corte histológico foi digitalizado e analisado em relação à existência de patologia periapical por três avaliadores independentes. Os dados obtidos foram confrontados estatisticamente utilizando o teste de Kruskal-Wallis seguido do teste comparativo de Dunn, observando-se que em relação às técnicas, a termoplástificação por ondas contínuas de condensação associada à técnica de injeção mostrou melhores condições periapicais quando comparada à técnica de condensação lateral (p=0.0055), sendo que a utilização desta técnica resultou em reações inflamatórias mais intensas para o cimento RealSeal SE (p=0.002). Em relação aos cimentos avaliados, o RealSeal SE mostrou-se menos eficaz em evitar a percolação, produzindo maiores níveis de inflamação crônica independentemente do sistema de obturação (p=0.0088). / Considering the need for three-dimensional obturations and adequate marginal sealing of the radicular canal system as being decisive factors for successful endodontic therapy, this study had as its objective the evaluation of periapical inflammatory responses resulting from coronary infiltration in dog\'s teeth obturated using different resin sealers (AH Plus, RealSeal and RealSeal SE) and different obturation techniques (lateral condensation and thermoplastic). For this study, premolars, central and lateral incisors from five dogs had endodontic treatment employing NiTi files and Endo PTC cream associated with 1% sodium hypochlorite. The working length was established at a distance of 1.0 to 1.5mm short of the radiographic apex. After this, the teeth were obturated according to their experimental groups (n=12) and control groups (n=10). The groups were defined as follows: GI - AH Plus/lateral condensation, GII - AH Plus/thermoplastic, GIII - RealSeal/lateral condensation, GIV - RealSeal/thermoplastic, GV - RealSeal SE/lateral condensation, GVI - RealSeal SE/ thermoplastic, a positive control group and a negative control group. The coronal access were left exposed to the oral environment for a period of seventy-five days, and after this experimental period, the dogs were euthanized by anesthetic overdose. The parts corresponding to the premolars and the maxilar incisors were surgically removed. These were then submitted to a solution of 10% formol for 72 hours and then demineralized in a solution of 20% formic acid and 10% sodium citrate for a minimum period of ninety days. Before hand, a histological routine of serial cuts having a width of 6m was undertaken and these were colored with hematoxilin and eosin (HE). Each histological cut was digitalized and analyzed with respect to the existence of periapical inflammation by three independent evaluators. The data obtained was statistically compared, firstly using the Kruskal-Wallis test and then the comparative Dunn test, where it was noted that in relation to the techniques, thermoplastification by continuous wave of condensation associated with the injection technique showed better periapical conditions than what was seen for the lateral condensation technique (p=0.0055). On the other hand, for the sealers evaluated, the condensation technique resulted in more intense inflammatory reactions when the sealer RealSeal SE was used (p=0.002). In relation to the sealers evaluated, RealSeal SE was seen to be less effective against percolation, thus producing greater levels of chronic inflammation irrespective of the obturation system employed (p=0.0088).
67

Impacto da ativação sônica e ultrassônica do cimento obturador dos canais radiculares na adaptação e resistência de união à dentina / Impact of sonic and ultrasonic activation of root canal sealer in the adaptation and bond strength to dentin

Wiesse, Paúl Ernesto Baca 07 April 2016 (has links)
O objetivo deste estudo foi avaliar a resistência de união, a penetração e a adaptação à dentina radicular de cimentos obturadores à base de resina epóxica e de silicato de cálcio com e sem ativação sônica e ultrassônica. Raízes de caninos superiores com 16 mm de comprimento foram submetidas a preparo biomecânico com instrumentos rotatórios de níquel titânio sob irrigação constante com NaOCl 2,5% e irrigação final com EDTA 17%. As raízes foram distribuídas em grupos de acordo com os cimentos obturadores: AH Plus e MTA Fillapex. Cada grupo foi subdividido em função da ativação do cimento obturador (n=13): sem ativação; ativação sônica por 30 segundos; ativação ultrassônica por 30 segundos. Em cada subgrupo, a manipulação dos cimentos obturadores foi realizada de acordo com as instruções dos fabricantes para 10 espécimes, para os 3 espécimes restantes, o cimento foi acrescido de Rodamina B 0,1% previamente à manipulação. A obturação foi realizada de acordo com o protocolo de cada subgrupo em relação ao cimento e ativação, utilizando-se a técnica de condensação lateral. Após três vezes os tempos de endurecimento dos cimentos, os espécimes foram seccionados obtendo-se 3 slices de 1,0 mm de espessura de cada terço radicular. Dois slices de cada terço foram submetidos ao teste de push-out e o padrão de falha foi determinado. O terceiro slice de cada terço radicular foi submetido à análise qualitativa da adaptação do cimento à dentina radicular e presença de vazios, por meio de microscopia confocal de varredura a laser. Nos espécimes em que o cimento foi acrescido de Rodamina B 0,1%, avaliou-se a penetração do cimento na dentina radicular por microscopia confocal de varredura a laser com fluorescência. Os dados foram analisados por testes estatísticos paramétricos e não-paramétricos. O cimento AH Plus (2,58±1,21) apresentou maior resistência de união comparado ao MTA Fillapex (1,45±0,71) (p<0,122). A ativação ultrassônica (2,64±1,44) propiciou maior resistência de união comparada aos grupos sem ativação (1,58±0,73) (p<0,0001) e com ativação sônica (1,83±0,85) (p<0,0001), não havendo diferença entre estes (p=0,3303). O terço cervical apresentou maior resistência de união (2,48±1,49) comparado ao médio (2,08±0,94) (p=0,0003) e apical (1,48±0,58) (p<0,001). Para o cimento MTA Fillapex houve predomínio de falhas adesivas mistas em todos os grupos, enquanto que para o cimento AH Plus houve predomínio de falhas adesivas mistas para os grupos sem ativação e ativação ultrassônica e falhas adesivas mistas e adesivas ao material obturador para o grupo de ativação sônica. A ativação ultrassônica promoveu, independente do cimento obturador, maior número, densidade e extensão de tags, com massa obturadora mais homogênea e adaptada às paredes do canal radicular. A ativação sônica, por sua vez, apresentou número, densidade e extensão de tags similares ao grupo sem ativação, no entanto a massa obturadora apresentou desadaptações e formação de bolhas. A ativação ultrassônica impactou na maior resistência de união, penetração, densidade e extensão de tags e melhor adaptação do cimento a dentina radicular, ao contrário da ativação sônica que não aumentou a resistência de união e penetração de tags e proporcionou maior desadaptação e inclusão de vazios na massa obturadora. / The aim of this study was to evaluate the bond strength, penetration and adaptation to the root dentin sealers based on epoxy resin and calcium silicate with and without sonic and ultrasonic activation. Maxillary canine roots with 16 mm length were submitted to biomechanical preparation with nickel titanium rotary files, under constant irrigation with 2.5% NaOCl and final irrigation with 17% EDTA. The roots were divided into groups according to the sealers: AH Plus and MTA Fillapex. Each group was subdivided based on sealer activation (n = 13): no activation; sonic activations (30 seconds); ultrasonic activation (30 seconds). In each subgroup, the sealer manipulation was performed according to the manufacturers instructions for 10 specimens, for the 3 remaining specimens, the Rhodamine B 0.1% was incorpored to the sealer prior to manipulation. The root canal filling was performed according to the protocol of each group relative to the sealer and activation, using the lateral condensation technique. After three times the sealer setting times, the specimens were sectioned and obtained 3 slices of 1.0 mm thickness of each root third. Two slices of each third were submitted to the push-out test and the failure pattern was determined. The third slice of each root third was submitted to qualitative analysis of sealer and root dentin adaptation and the presence of voids, by means of confocal laser scanning microscopy. In specimens in which Rhodamine B 0.1% was added in the sealer was evaluated the sealer penetration in root dentin by confocal laser scanning fluorescence. The data were analyzed using parametric and nonparametric statistical tests. The AH Plus (2.58 ± 1.21) showed higher bond strength compared to MTA Fillapex (1.45 ± 0.71) (p <0.122). The ultrasonic activation (2.64 ± 1.44) provided higher bond strength compared to no activation groups (1.58 ± 0.73) (p <0.0001) and sonic activation (1.83 ± 0.85) (p <0.0001), with no difference between them (p = 0.3303). The cervical third showed higher bond strength (2.48 ± 1.49) compared to the middle (2.08 ± 0.94) (p = 0.0003) and apical thirds (1.48 ± 0.58) (P < 0.001). For the MTA Fillapex there was a predominance of mixed adhesive failures in all groups, whereas for AH Plus there was a predominance of mixed adhesive failures for groups without activation and ultrasonic activation and mixed adhesive failures and adhesives to the filling material for the sonic activation group. Ultrasonic activation promoted, regardless of the sealer, the greater number, density and length tags with more homogenous and adapted root canal filling to the root canal walls. On the other hand, the sonic activation, presented number, density and length of tags similar to the group without activation, however the root canal filling showed mismatches and blistering. Ultrasonic activation impacted the highest bond strength, penetration, density and length tags and better adaptation of the sealer root dentin, unlike the sonic activation that not increased bond strength and penetration tags and provided greater mismatch and the inclusion of voids in the root canal filling.
68

Influência do hidróxido de cálcio na penetração do cimento Epiphany TM nos túbulos dentinários e na adaptação às paredes do canal radicular: avaliação pela microscopia confocal de varredura a laser / Influence of calcium hydroxide dressing on Epiphany TM sealer depth of dentinal tubules and interface dentine-sealer: a confocal study

Camargo, Éricson Janolio de 25 May 2009 (has links)
Avaliou-se a influência do curativo intra-canal com pasta de hidróxido de cálcio na penetração do cimento EpiphanyTM no interior dos túbulos dentinários e na adaptação do cimento às paredes dos canais radiculares utilizando-se a microscopia confocal de varredura a laser (MCVL). Foram utilizados 30 incisivos centrais inferiores humanos, extraídos, com apenas um canal radicular. O acesso ao canal foi realizado de forma convencional utilizando-se pontas diamantadas montadas em alta rotação, sob refrigeração. Os canais foram preparados pela técnica progressiva empregando-se instrumentos manuais e rotatórios de níquel-titânio, Protaper e Profile (conicidade 0.4). A irrigação foi realizada usando solução de hipoclorito de sódio a 1% e, ao final do preparo, o soro fisiológico. Após o preparo, os canais radiculares de todos os dentes receberam aplicação de EDTA a 17% por 3 minutos e irrigação final com soro fisiológico. A seguir, os dentes foram divididos em 3 grupos como segue: grupo 1 sem tratamento adicional (controle); grupo 2 curativo de Ca (OH)2 e grupo 3 - curativo de Ca (OH)2 e nova aplicação de EDTA. O curativo de Ca (OH)2 foi empregado na forma de pasta viscosa com propilenoglicol que foi inserida no canal com espiral de Lentulo. Após o curativo, os dentes foram armazenados a ± 37 °C por 14 dias. A remoção do curativo foi feita com irrigação com soro fisiológico e com instrumento manual. A seguir, os canais radiculares de todos os 30 espécimes foram obturados com o Sistema EpiphanyTM utilizando-se o primer, o cimento EpiphanyTM, cones principais de Resilon 40/0.4 e cones auxiliares fino-médio pela técnica da condensação lateral ativa. Antes da obturação, o cimento foi corado com Rodamina B. Foram feitas secções transversais a 3, 7 e 10 milímetros distantes do forame apical (terços apical, médio e cervical), cujas imagens foram analisadas em microscopia confocal por varredura a laser (MCVL). Os resultados foram submetidos aos testes estatísticos de Análise de Variância (ANOVA) e teste Tukey, ambos com 5% de significância. Os resultados indicaram que a maior penetração de cimento no interior dos túbulos dentinários foi verificada nas secções dos terços cervical e médio do grupo II comparado aos grupos I e III. A penetração do cimento em todas as secções foi maior e estatisticamente significante nas faces vestibular e lingual. Em relação à adaptação do cimento às paredes dos canais radiculares, a fluorescência do cimento, considerando o perímetro total do canal mostrou regiões com falhas na interface dentina-cimento. A menor porcentagem de adaptação foi observada no grupo I (78%) comparado com os grupos II (93%) e III (86%) (p<0,05). Em canais obturados com o Sistema EpiphanyTM pela técnica da condensação lateral, o hidróxido de cálcio influenciou positivamente na profundidade de penetração do cimento no interior dos túbulos dentinários e na sua adaptação às paredes dos canais. / The aim of this study was to evaluate the influence of calcium hydroxide on the depth of dentinal tubule sealer penetration and the percentage of sealer-dentin interface in the coronal, middle and apical thirds teeth obturated with the EpiphanyTM Obturation System using 5 x and 40x confocal laser scanning microscopy. Thirty extracted single-rooted mandibular incisor human teeth were instrumented using 1.0 % NaOCl. The smear layer was removed using 17% EDTA for 3 minutes. The teeth were randomly assigned to 3 groups (n=10), according to the presence or absence of intracanal dressing and its removal: GI= non Ca(OH)2 dressing (control); G II= Ca(OH)2 + removal using saline solution and kfile # 40; and G3= Ca(OH)2 + removal using saline solution + kfile # 40 and 17% EDTA. One tooth from groups II and III were ramdomly selected for calcium hydroxide analysis. The calcium hidroxyde was labeled with fluorescent fluorescein and after 14 days of storage in 100% humidity at 37 degrees C, the dressings were removed from experimental groups. All root canals (control and experimental groups) were obturated with Resilon master points 40/0.4, Resilon points fine-medium and EpiphanyTM sealer labeled with fluorescent Rhodamine B dye. The sections cut from the coronal, middle and apical thirds of each root were viewed using 5x and 40x confocal laser scanning microscopy. Twoway ANOVA and Tukey test found significantly lower average depth of sealer penetration in apical sections than middle or coronal sections (p<0,05). The deepest sealer penetration was observed in the coronal and middle secctions of group II compared to the groups I and III. The sealer penetration in all sections was deeper and statistically different in the vestibular and lingual faces. A fluorescent sealer ring was seen around the canal wall in all sections presenting some gaps in the sealerdentin interface. Two-way ANOVA and Tukey tests showed significantly less percentage of sealer-dentin interface in the group I (78%) compared to groups II (93%) and III (86%) (p<0,05). Calcium hydroxide dressing affected positively the deep of sealer penetration and percentagem of sealer dentin interface in the root canals filled with EpiphanyTM resin based sealer.
69

Avaliação da remoção de debris dentinários após diferentes métodos de irrigação final e sua influência na obturação do sistema de canais radiculares, utilizando a microtomografia computadorizada / Hard-tissue debris removal after different final irrigation methods and its influence on the filling of the root canal system, using micro-computed tomography

Freire, Laila Gonzales 03 June 2014 (has links)
A instrumentação do canal radicular possui como conseqüência a formação de debris dentinários, os quais acumulam-se especialmente nas áreas mais complexas do sistema de canais radiculares. Por este motivo, atenção especial tem sido concedida aos métodos de agitação da substâ ncia química auxiliar, com o intuito de melhorar a sua eficácia química e mecânica. No entanto, não está claro se debris dentinários removidos do interior do canal radicular possuem efeito na qualidade da obturação. Portanto, os objetivos deste estudo foram, com o auxílio da microtomografia computadorizada (micro-CT): avaliar e quantificar a presença de debris dentinários em canais curvos, após o preparo químico-cirúrgico; comparar a remoção desses debris, após uso de Irrigação Ultrassônica Passiva (IUP) ou do sistema EndoVac; e avaliar a qualidade da obturação dos mesmos canais, mensurando o volume de material obturador e de espaços vazios. Vinte e quatro raízes mesiais de molares inferiores humanos extraídos foram divididos aleatoriamente em 2 grupos (n=12), de acordo com o método de irrigação final a ser avaliado. Cada espécime foi submetido a quatro escaneamentos: exame préoperatório, exame pós-preparo, exame pós-irrigação final e exame pós-obturação, com um microtomógrafo de raios-X SkyScan 1176, a uma resolução de 17,42 m. Após preparo químico-cirúrgico os grupos receberam irrigação final com IUP ou com o sistema EndoVac e em seguida obturados com a técnica termoplástica de ondas contínuas de condensação. Após a reconstrução das imagens resultantes dos quatro escaneamentos, o corregistro das mesmas foi realizado com o programa DataViewer. Os programas CTAn e CTvol foram utilizados para binarização dos objetos de interesse, análise volumétrica e reconstrução de modelos 3D do canal radicular, dos debris dentinários e do material obturador. Os dados foram analisados estatisticamente com o programa GraphPad Prism por meio do teste t de Student (p < 0,05). As análises de micro-CT revelaram debris dentinários acumulados no interior dos canais radiculares, ocupando uma porcentagem média em relação ao volume do canal de 2,71% para o grupo IUP e 4,10% para o grupo EndoVac. Não houve diferença entre os grupos quanto à remoção de debris dentinários, nem em relação ao volume de material obturador e de espaços vazios (p > 0,05). Concluiu-se que a IUP e o sistema EndoVac foram igualmente eficientes na remoção de debris dentinários, reduzindo em média 50% do seu volume. Também, a ativação dos irrigantes pelos dois métodos não interferiu na qualidade da obturação do canal radicular. / Root canal preparation has as a consequence the formation of hard-tissue debris, which accumulates specially in the complex areas of the root canal system. For this reason, special attention has been given to methods of agitation of the irrigants, aiming to improve its chemical and mechanical efficiency. However, it is not clear if dentin debris removed from the root canal have impact on the quality of root canal filling. Therefore, the objectives of this study were, with the aid of microcomputed tomography (micro-CT): evaluate and quantify the presence of hard-tissue debris in curved root canals, after chemical-surgical preparation; compare the removal of such debris after final irrigation with Passive Ultrasonic Irrigation (PUI) or with the EndoVac system; and evaluate the quality of filling of the same root canals, measuring the volume of filling material and voids. Twenty-four mesial roots of extracted mandibular human molars were randomly divided into 2 groups (n = 12) according to the method of final irrigation being evaluated. Each specimen was subjected to four scans: preoperative, post-operative, post-final irrigation and post-filling, with a microcomputed tomography SkyScan 1176, at a resolution of 17,42 m. After chemosurgical preparation groups received final irrigation with Passive Ultrasonic Irrigation (PUI) or with EndoVac system and were then filled with the continuous wave condensation thermoplastic technique. After the reconstruction of the images resulted from the four scans, co-registration was performed with the DataViewer software. CTAn and CTvol softwares were used for binarization of the objects of interest, volumetric analysis and reconstruction of 3D models of the root canal, hardtissue debris and the filling material. Data were statistically analyzed with the GraphPad Prism program through t students test (p < 0,05). The analysis of micro- CT showed hard-tissue debris accumulated inside the root canal, occupying an average percentage of 2.71 % for the PUI group and 4.10 % for EndoVac group. There was no difference between the groups regarding the removal of hard-tissue debris, or in relation to the volume of filling material and voids (p > 0.05). It was concluded that the EndoVac and PUI were equally efficient in the removal of hardtissue debris, reducing an average of 50% of its volume. Also, irrigants activation with the two methods did not affect the quality of root canal filling.
70

Ausência de correlação entre a penetração do cimento AH Plus nos túbulos dentinários e a qualidade do selamento / Lack of correlation between AH Plus sealer penetration into dentinal tubules and sealability

Maria Cláudia Brandão de Souza 30 March 2010 (has links)
O presente estudo objetivou testar experimentalmente a existência da possível correlação entre a penetração de cimento nos túbulos dentinários e a qualidade do selamento. Foram utilizados 60 incisivos centrais superiores humanos que formaram um único grupo experimental. Após a eliminação das porções coronárias, as raízes foram padronizadas em 13 mm de comprimento. A instrumentação dos canais foi realizada no sentido coroa-ápice, e o comprimento de trabalho estabelecido a 1 mm aquém do forame apical. Como solução irrigadora foi empregado o NaOCl a 5,25% e ao final, EDTA a 17%. Em seguida, todos os canais foram obturados com guta-percha e cimento AH Plus marcado com um corante fluorescente. Para determinar a qualidade do selamento das obturações endodônticas, as amostras foram submetidas ao modelo de infiltração de glicose sob pressão. As raízes foram montadas em um dispositivo de dupla-câmara selada para permitir a infiltração da glicose. Como controle negativo foram utilizados 4 dentes hígidos, e como controle positivo, 2 dentes instrumentados porém, não obturados. Foram utilizados 0,75 mL de solução de glicose a 1 mol/L na câmara superior e 0,75 mL de água deionizada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão desenvolvido com o objetivo de permitir a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15 psi durante 1 hora. Uma alíquota de 50 L foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada através de um método enzimático com o auxílio do Kit Glucose HK e de um espectrofotômetro em um comprimento de onda de 340 nm. Na sequência, as amostras foram desacopladas dos corpos de prova, embutidas em resina epóxi e cortadas em 3 secções transversais. Uma sequência de preparação metalográfica padrão foi realizada para permitir a observação da penetração de cimento nos túbulos dentinários por meio de microscopia confocal e óptica. Os dados obtidos nos 2 experimentos foram cruzados pelo teste de correlação de Spearman, o qual revelou a inexistência de qualquer possibilidade de correlação (r = 0,12). Com base nesses resultados, o presente trabalho concluiu que, dentro das condições experimentais usadas, a quantidade de cimento presente dentro dos túbulos dentinários não teve relação com a qualidade do selamento produzido. / The purpose of the present study was to experimentally test the potential correlation between tubular dentin sealer penetration and sealability. Sixty human maxillary central incisors were selected in order to compose a single experimental group. After removing of crowns, the roots were standardized at 13 mm in length. A crown-down root canal instrumentation was performed 1mm short of the apical foramen (working length). How irrigating solution was used 5.25% NaOCl and final, 17% EDTA. Then, all root canals were filled with gutta percha and AH Plus sealer labeled with a fluorescent dye. To determine the sealability pattern, samples were submitted to glucose leakage model under pressure. Four intact teeth were used as negative control while further 2 instrumented but nonfilled teeth was used as positive control. The roots were mounted in a double-chamber apparatus where 0,75 mL of 1 mol/L glucose solution was placed into the superior chamber and 0,75 mL of deionized water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed in order to allow testing 32 specimens at the same experimental stage. The glucose solution was forced apically under a pressure of 15 psi during 1 hour. A sample of 50 L was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using a Glucose HK Kit readed under spectrophotometry (wave-length of 340 nm). After that, the samples were removed from the apparatus, embedded in epoxy resin and cut into 3 sections. Standard metallographic preparation was performed prior the observation of the sealer penetration into dentinal tubules by confocal and optical microscopy. Data provided by the evaluations were submitted to Spearman correlation test which revealed a lack of correlation between the two variables (r = 0.12). Therefore, the present study concluded that there was no correlation between tubular sealer penetration and sealability in non-bonding conventional root-fillings.

Page generated in 0.0886 seconds