Spelling suggestions: "subject:"ondas elétrica"" "subject:"ondas elétrico""
11 |
Contribuição ao projeto de filtros ativos monofasicos de potenciaAtaide, Marcus Vinicius 27 January 1997 (has links)
Orientador: Jose Antenor Pomilio / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-22T10:31:58Z (GMT). No. of bitstreams: 1
Ataide_MarcusVinicius_M.pdf: 5078211 bytes, checksum: 6a7d34e5151e3966f322f4d72fb4ccbf (MD5)
Previous issue date: 1997 / Resumo: Este trabalho apresenta um estudo aplicado a Filtro Ativo Monofásico de Potência, tendo como "foco principal" o projeto do filtro passivo de saída e da malha de controle. Na análise são considerados os limites estabelecidos por normas internacionais com respeito à interferência eletromagnética conduzida e ao limite de harmônicas de corrente. Os efeitos da impedância da linha e das perdas no filtro passivo também são considerados para o correto dimensionamento do mesmo, visando a não degradação da performance do filtro ativo. Consegue-se uma filtragem da corrente drenada da rede por uma carga não linear, de maneira satisfatória, com freqüência de corte do filtro passivo de saída superior a 3kHz (50!:! harmônica da corrente de linha) sendo os limites de IEM atingidos através do filtro de saída, não amortecido, e com ordem elevada. Resultados de simulação e experimentais são apresentados / Abstract: This work presents a study of single-phase active filters investigating specifically the design of the output filter and the control loop. The limits imposed by international standards regarding harmonics and conducted EMI are considered. The effect of the line impedance and the losses in the filter elements must be taken into account to have a secure design. An excellent harmonic compensation is obtained by means of a flat frequency response up to 3kHz, while the EMI limits is obtained by using a high order undraped low-pass filter. Simulation and experimental results are presented. / Mestrado / Mestre em Engenharia Elétrica
|
12 |
Projeto e implementação de filtro ativo trifasico de potencia, usando o metodo da sintese de carga resistivaNuñez Zuñiga, Teresa Esther 21 May 1999 (has links)
Orientador: Jose Antenor Pomilio / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-25T12:45:06Z (GMT). No. of bitstreams: 1
NunezZuniga_TeresaEsther_M.pdf: 3630934 bytes, checksum: 2acfac5c80f239575de6eac9da690d96 (MD5)
Previous issue date: 1999 / Resumo: A presente dissertação trata do estudo de um Filtro Ativo de Potência (FAP) trifásico a três fios, em sistemas elétricos nos quais se considera a presença de tensões simétricas, mas distorcidas, seguindo o método da síntese de carga resistiva. Discutem-se os problemas que podem surgir no sistema quando se faz a síntese de corrente senoidal em situações com tensões distorcidas. O circuito de controle está baseado em multiplicadores, como nos circuitos corretores do fator de potência, permitindo assim que a corrente siga a mesma forma de onda da tensão, usando um modulador MLP. No projeto foram considerados os limites estabelecidos pelas normas internacionais com relação às harmônicas de corrente e à interferência eletromagnética conduzida. Apresentam-se resultados práticos e de simulação do FAP trifásico / Abstract: This work deals with the study of a Three-Phase Active Power Filter in a Three-wire grid, used in electric systems where the voltage is balanced but distorted. This work follows the Resistive Load Synthesis over the Sinusoidal Current Synthesis. The control structure is based on multipliers, like in power factor corrector topologies, in order to generate the necessary compensating current using a PWM modulator. The limits imposed by international standards regarding harmonics and conduced EMI are considered in the filter design. Simulations and experimental results are presented. / Mestrado / Mestre em Engenharia Elétrica
|
13 |
Uma contribuição ao estudo de controle de reativos em fontes retificadoras assimetricas semi-controladasMilanez, Dalgerti Lelis 15 July 2018 (has links)
Orientador : Mauro Sergio Miskulin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-15T05:02:44Z (GMT). No. of bitstreams: 1
Milanez_DalgertiLelis_M.pdf: 3411964 bytes, checksum: 6de7080f3b65fdb40ab96ed873535f94 (MD5)
Previous issue date: 1987 / Resumo: A Ponte Assimétrica Semi-Controlada com controle de fase e com a inclusão de um filtro RC na entrada. é analisada quanto ao fator de potência e conteúdo de harmônicas das ondas de tensao e corrente. A simulação digital foi efetuada pelo metodo de Runge-Kutta de 4a. ordem o qual mostrou-se inadequado; e por um metodo analítico que serviu de base ao levantamento dos dados para a obtenção das formas de ondas e suas analises. Os resultados da simulação digital foram comparados com as medidas feitas em um prot5tipo com potência reduzida. Demonstra-se que o filtro apresenta viabilidade / Abstract: Not informed / Mestrado / Mestre em Engenharia Elétrica
|
14 |
Desenvolvimento de um simulador de redes elétricas para estudos da propagação de harmônicosLIMA, Diorge de Souza 23 August 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-04T13:44:49Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-10T17:41:03Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5) / Made available in DSpace on 2017-01-10T17:41:03Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DesenvolviementoSimuladorRedes.pdf: 3993762 bytes, checksum: d833db03c025ab4cf9cb2cc2e7498a7e (MD5)
Previous issue date: 2016-08-23 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O setor elétrico brasileiro tem enfrentado grandes mudanças devido a modernização dos equipamentos elétricos, principalmente quando se refere aos consumidores residenciais. Isso tem proporcionado um aumento considerável do nível de distorção de harmônicos nas redes elétricas de distribuição, o que pode ser justificado pelo uso acentuado de equipamentos baseados na eletrônica de potência, na tentativa de torná-los cada vez mais eficientes e compactos. Portanto, torna-se necessário a realização de diagnóstico quanto aos níveis de distorções harmônicas em sistemas elétricos. O monitoramento por analisadores de energia é a melhor forma de obter os dados do sistema elétrico, entretanto a simulação computacional é uma eficiente ferramenta capaz de reproduzir os distúrbios e o comportamento da rede elétrica para diferentes modos de operação. Logo, este trabalho tem como objetivo apresentar um ambiente computacional que auxilie nos estudos de propagação de harmônicos nos sistemas elétricos. Para isso, utilizou-se o software ATP (Alternative Transient Program) para a modelagem do sistema elétrico, o comportamento harmônico de uma carga não linear é representado por valores eficazes de medidas de correntes harmônicas em função do tempo. As medidas foram obtidas por meio de analisares de qualidade da energia conectados em uma rede de distribuição da região norte do Brasil. Logo, para esse conjunto de medidas, foi realizado um conjunto de simulações, disponibilizando ao usuário valores de tensões harmônicas para todos os barramentos do sistema elétrico. Portanto, com o simulador de redes elétricas será possível realizar estudos de propagação de harmônicos em diversos sistemas elétricos, podendo auxiliar como uma ferramenta de planejamento estratégico quanto ao uso de medidas mitigadoras ou mesmo para o controle estratégico das distorções harmônicas, a partir das avaliações dos principais momentos críticos de distorções harmônicas em todos os pontos da rede elétrica. Para demonstrar a utilização, o sistema industrial de 13 barras foi utilizado como um sistema teste para as análises nesta dissertação. / The electricity sector in Brazil has faced many changes due to the modernization of electrical equipment, especially when it refers to residential consumers. This has provided a considerable increase in the level of harmonic distortion in the electric distribution networks, which can be explained by the large use of devices based on power electronics in an attempt to make them more efficient and compact. Therefore, it becomes necessary execute analysis of the levels of harmonic distortion in the power systems. Monitoring by power quality analyzer is the best way to collect data of the electrical system; however, the computer simulation is an efficient tool capable of reproducing the disturbances and behavior of the electric networks for different operating modes. Thus, this paper aims to present a computational environment that helps the harmonic propagation studies in electrical systems. For this, it was used the software ATP (Alternative Transient Program) for modeling the electrical system, the harmonic behavior of a nonlinear load is represented by effective values of harmonic currents in function of time. The measurements were obtained through power quality analysis of a distribution network in the North Region of Brazil. Thus, for this set of measures, a set of simulations was performed, providing for the users the values of harmonic voltages for all buses of the electrical system. Therefore, with the simulator of electrical networks it is possible perform harmonic propagation studies in several electrical systems, and it can work as a strategic planning tool for the use of mitigating measures or for the strategic control of harmonic distortion, from evaluations of most critical moments of harmonic distortion at all points of the network. To demonstrate its use, the industrial system of 13 bar was used as a test system for analysis in this dissertation.
|
15 |
Estudo e implementação de um filtro ativo de potência paralelo aplicado em sistemas trifásicos a quatro fios com controle e modulação vetorialAcordi, Edson Junior 31 August 2012 (has links)
O presente trabalho realiza o estudo e implementação de um filtro ativo de potência paralelo (FAPP) aplicado em sistemas trifásicos a quatro fios utilizando a topologia de um inversor de tensão four-legs, visando a redução do conteúdo harmônico gerado por cargas não lineares e a compensação de reativos. A geração das correntes de referência de compensação é obtida através da estratégia de compensação baseada no sistema de eixos de referência síncrona (SRF) a qual utiliza conceitos de controle vetorial. O sincronismo do sistema SRF é realizado através de um circuito q-PLL (q-Phase Locked Loop) o qual é baseado no conceito da teoria da potência instantânea imaginária (teoria pq). A análise matemática da topologia four-legs é desenvolvida a fim de se obter um modelo linear em espaço de estados que represente o sistema físico para os sistemas de coordenadas abc, αβ0 e dq0. O método de controle proposto é implementado em eixos dq0, através de três controladores do tipo PI (Proporcional-Integral), os quais são projetados utilizando os conceitos de margem de estabilidade. Um estudo detalhado da modulação Space Vector aplicada a sistemas trifásicos four-legs é apresentado. Resultados de simulações são apresentados para validar o modelo do filtro proposto bem como a técnica de controle aplicada. Por fim, os resultados experimentais obtidos são avaliados considerando a a recomendação IEEE 519-1992 para mostrar a capacidade do FAPP na supressão de correntes harmônicas e compensação de potência reativa. / This work deals with the study and analysis of a parallel active power filter (APF) applied to three-phase four-wire systems using a four-leg inverter, aiming the suppresion of the harmonic content of non-linear loads and reactive power compensation. The generation of the compensation current references is obtained by means of the strategy based on the synchronous reference frame (SRF) system, which utilizes the concepts of vector control. The timing of the SRF system is performed through a q-PLL (q-Phase Locked Loop) circuit that is based on the imaginary instantaneous power theory. Mathematical analysis is developed in order to obtain a linear model in state space that represents the physical system in the coordinate systems abc, αβ0 and dq0. The proposed control method is implemented in dq0 axes through three Proportional-Integral (PI) controllers, which are designed using the concepts of stability margin. A detailed study of Space Vector modulation applied to three-phase four-leg inverter is presented. Simulation results are presented to validate the model of the APF and the control technique adopted. Finally, experimental results are obtained and evaluated considering the recommendation IEEE 519-1992 to show the capability of the parallel APF of current harmonic suppression and reactive power comensation.
|
16 |
Sistema UPS line-interactive monofásico com compensação ativa de potência série e paralelaBarriviera, Rodrigo 31 July 2012 (has links)
Este trabalho apresenta o projeto e implementação de um sistema UPS (Uninterruptible Power Supply) Line-Interactive monofásico com compensação ativa de potência série e paralela, o qual realiza a supressão de harmônicos e compensação de afundamentos e elevações da tensão da rede elétrica, além de manter a tensão na carga regulada. Adicionalmente, a UPS atua na compensação de potência reativa e supressão dos harmônicos de corrente da carga, resultando em uma efetiva correção do fator de potência. Desse modo, com a rede elétrica presente, a UPS opera como filtro ativo universal realizando a compensação da corrente de entrada, bem como da tensão de saída. Quando a rede elétrica está ausente, a UPS alimenta a carga com tensão regulada e com baixa taxa de distorção harmônica. Para este fim, dois conversores monofásicos PWM são empregados, sendo estes chamados de filtro ativo série (FAS), o qual atua como fonte de corrente senoidal e o filtro ativo paralelo (FAP), o qual atua como fonte de tensão senoidal, ambos controlados para operar em fase com a tensão da rede. Com o objetivo de extrair a corrente de referência senoidal de compensação, usada no controle do FAS, é utilizado um algoritmo baseado no sistema de eixo de referência síncrona (SRF-Synchronous Reference Frame). Para a obtenção da referência da tensão senoidal de saída, assim como as coordenadas do vetor unitário síncrono utilizados pelo algoritmo SRF, um sistema de detecção de ângulo de fase (PLL-Phase Locked Loop) monofásico é utilizado. Ensaios experimentais, bem como simulações computacionais são realizados a fim de confirmar o desenvolvimento teórico e avaliar o desempenho dinâmico e estático do sistema UPS. / This work presents a single-phase Line-interactive UPS System implementation with series and parallel active power-line compensation, which performs harmonic suppression and voltage sag/swell compensation of the utility voltage, as well as maintaining the output voltage regulated. Additionally, the UPS performs reactive power compensation and harmonic suppression of the load current, resulting in an effective power-factor correction. Thereby, when the incoming power grid is present, the UPS works as a universal active power filter compensating the input current and output voltage. On the other hand, when an outage occurs, the UPS feeds the load with regulated and harmonic free voltage. For this purpose, two single-phase PWM converters are employed, which are referred as series active power filter (SAPF), which acts as a sinusoidal current source, and parallel active power filter (PAPF), which acts as a sinusoidal voltage source. Both the APFs are controlled to be in phase with the input voltage. In order to extract the sinusoidal compensation reference current, used in SAPF control, an algorithm based on synchronous reference frame (SRF) is used. The sinusoidal output voltage reference and the coordinates of the synchronous vector are obtained by using a phase-locked loop (PLL) algorithm. Experimental results and computational simulations are presented to confirm the theoretical development and evaluate both the dynamic and steady state behavior of the UPS system.
|
17 |
Sistema UPS line-interactive monofásico com compensação ativa de potência série e paralelaBarriviera, Rodrigo 31 July 2012 (has links)
Este trabalho apresenta o projeto e implementação de um sistema UPS (Uninterruptible Power Supply) Line-Interactive monofásico com compensação ativa de potência série e paralela, o qual realiza a supressão de harmônicos e compensação de afundamentos e elevações da tensão da rede elétrica, além de manter a tensão na carga regulada. Adicionalmente, a UPS atua na compensação de potência reativa e supressão dos harmônicos de corrente da carga, resultando em uma efetiva correção do fator de potência. Desse modo, com a rede elétrica presente, a UPS opera como filtro ativo universal realizando a compensação da corrente de entrada, bem como da tensão de saída. Quando a rede elétrica está ausente, a UPS alimenta a carga com tensão regulada e com baixa taxa de distorção harmônica. Para este fim, dois conversores monofásicos PWM são empregados, sendo estes chamados de filtro ativo série (FAS), o qual atua como fonte de corrente senoidal e o filtro ativo paralelo (FAP), o qual atua como fonte de tensão senoidal, ambos controlados para operar em fase com a tensão da rede. Com o objetivo de extrair a corrente de referência senoidal de compensação, usada no controle do FAS, é utilizado um algoritmo baseado no sistema de eixo de referência síncrona (SRF-Synchronous Reference Frame). Para a obtenção da referência da tensão senoidal de saída, assim como as coordenadas do vetor unitário síncrono utilizados pelo algoritmo SRF, um sistema de detecção de ângulo de fase (PLL-Phase Locked Loop) monofásico é utilizado. Ensaios experimentais, bem como simulações computacionais são realizados a fim de confirmar o desenvolvimento teórico e avaliar o desempenho dinâmico e estático do sistema UPS. / This work presents a single-phase Line-interactive UPS System implementation with series and parallel active power-line compensation, which performs harmonic suppression and voltage sag/swell compensation of the utility voltage, as well as maintaining the output voltage regulated. Additionally, the UPS performs reactive power compensation and harmonic suppression of the load current, resulting in an effective power-factor correction. Thereby, when the incoming power grid is present, the UPS works as a universal active power filter compensating the input current and output voltage. On the other hand, when an outage occurs, the UPS feeds the load with regulated and harmonic free voltage. For this purpose, two single-phase PWM converters are employed, which are referred as series active power filter (SAPF), which acts as a sinusoidal current source, and parallel active power filter (PAPF), which acts as a sinusoidal voltage source. Both the APFs are controlled to be in phase with the input voltage. In order to extract the sinusoidal compensation reference current, used in SAPF control, an algorithm based on synchronous reference frame (SRF) is used. The sinusoidal output voltage reference and the coordinates of the synchronous vector are obtained by using a phase-locked loop (PLL) algorithm. Experimental results and computational simulations are presented to confirm the theoretical development and evaluate both the dynamic and steady state behavior of the UPS system.
|
18 |
Uma contribuição ao estudo e projeto de um inversor trifasico de tensão a tres niveisMoreno Martinez, Rodolfo Manuel 05 August 1997 (has links)
Orientador: Ernesto Ruppert Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia e de Computação / Made available in DSpace on 2018-07-22T21:13:02Z (GMT). No. of bitstreams: 1
MorenoMartinez_RodolfoManuel_M.pdf: 9266365 bytes, checksum: 28a887f54983817261be9938956bbcd1 (MD5)
Previous issue date: 1997 / Resumo: : O objetivo deste trabalho é o de estudar, através de simulações, o comportamento em regime permanente de um sistema constituído por um motor de indução trifásico acionando uma carga mecânica, alimentado por um inversor trifásico de tensão a três níveis. Estabeleceu-se modelos matemáticos dinâmicos para o motor e para o inversor e utilizou-se para as simulações os ambientes computacionais Matlab e Pspice de acordo com o tipo de estudo realizado. Para a operação do inversor a três níveis considerou-se as técnicas de modulação em largura de pulso por eliminação seletiva de harmônios e por modulação vetorial que são as técnicas que estão, hoje, em maior evidência na literatura. Mostra-se no trabalho comparações do desempenho do inversor a três níveis com o desempenho do inversor a dois níveis chateados por modulação em largura de pulso senoidal, eliminação seletiva de harmônicos e modulação vetorial. Os inversores a três níveis apresentam baixo conteúdo harmônico em tensão e corrente de saída com baixa freqüência de chaveamento enquanto os de 2 níveis exigem freqüências maiores de chaveamento para a obtenção do mesmo conteúdo do harmônicos resultando em diminuição da vida das chaves e em redução da eficiência. Os inversores a três níveis, pelo fato de terem suas chaves, quando desligadas, submetidas a tensões menores são sujeitos a menos ?stress? de tensão ou passíveis de operar em potências maiores. Neste trabalho também apresenta-se uma técnica de projeto baseada em resultados de simulação / Abstract: The main goal of this thesis is to simulate the steady-state performance of a three-level, three-phase, voltage-controlled inverter driving a three-phase induction motor. Dynamic mathematical models for the motor and the inverter were done and the Matlab and Pspice computational ambients were used according to the type of the study to be performed. To study the operation of the three-level inverter it was considered the following PWM techniques: a) Selective harmonic elimination (SHE), b) Vector modulation. Both techniques are today in great evidence in the concemed literature. It is shown performance comparisons with the two-level inverter switched by sinusoidal PWM, selective harmonic elimination and vector modulation. The three-level inverter presents a small output voltage and current harmonics contents even with small switching frequency while the two-level inverter needs higher swiching frequencies to get the same harmonic contents. This results in the switch life and efficiency deceasing. If the three-level inverter switch is off it is submitted to half voltage, when compared with the two-level inverters, so they are less stressed than the two-level ones and they are able also to operate in higher rates. It is also presented a tree-level inverter design technique based on simulation results / Mestrado / Mestre em Engenharia Elétrica
|
19 |
Um modelo alternativo baseado em conjuntos nebulosos aplicado ao planejamento da compensação reativa em redes de distribuição que contem cargas especiaisPenha, Fernando Diniz 08 November 2000 (has links)
Orientador : Carlos Alberto F. Murari / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T02:49:32Z (GMT). No. of bitstreams: 1
Penha_FernandoDiniz_D.pdf: 5199839 bytes, checksum: 8f72e811cae27b11515175227f6ef6cc (MD5)
Previous issue date: 2000 / Resumo: Este trabalho propõe um modelo de decisão baseado em conjuntos nebulosos para a alocação e dimensionamento de bancos de capacitores-shunt em redes de distribuição de energia elétrica na presença de fontes geradoras de harmônicos (cargas especiais). A característica principal desta metodologia é a incorporação de uma estrutura de preferências do planejador em um adequado processo de decisão no âmbito do planejamento da compensação reativa em redes elétricas que contenham cargas especiais, o que se dá através de uma modelagem baseada em conjuntos nebulosos, permitindo um tratamento matemático das incertezas e/ou imprecisões inerentes ao raciocínio humano. Uma rotina de cálculo de fluxo de carga harmônico, baseada em uma modelagem trifásica da rede elétrica é utilizada como ferramenta computacional para a solução do estado da rede em cada etapa do planejamento e para a definição do universo de discurso do problema de tomada de decisão. Testes foram realizados em algumas redes de distribuição típicas que contêm uma ou mais fontes harmônicas, sob diferentes condições de operação e diferentes níveis de preferência do planejador com o intuito de avaliar as potencialidades e a coerência da aplicação da metodologia proposta / Abstract: This work proposes a decision model which is based on fuzzy sets for location and sizing of shunt capacitors on Distribution Systems Networks in presence of sources harmonics (loads specials). The main characteristic of this methodology is to incorporate a planner preferences structure into an appropriate decision process on scope of reactive compensation planning in power systems which contain specials loads by a model based in fuzzy sets allowing an mathematic treatment of fuzziness and/or imprecision's inherent on human judgment. A routine of harmonic load flow calculus which is based on three-phase model of network is used for to frnd their state solution in each stage of planning and to determine the universal set of decision making problem. Simulations were performed in some typical distribution power systems which contains one or varlous harmonics sources under distinct conditions of operation and levels preferences of the planner with objectives of to evaluate the potentialities and the coherence of the proposed methodology / Doutorado / Doutor em Engenharia Elétrica
|
20 |
Methodology for evaluating the collective harmonic impact of residential loads in modern power distribution systems = Metodologias para a avaliação do impacto harmônico coletivo de cargas residenciais em modernos sistemas de distribuição de energia elétrica / Metodologias para a avaliação do impacto harmônico coletivo de cargas residenciais em modernos sistemas de distribuição de energia elétricaSalles Corrêa, Diogo 06 April 2012 (has links)
Orientador: Walmir de Freitas Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-21T14:56:46Z (GMT). No. of bitstreams: 1
SallesCorrea_Diogo_D.pdf: 3415156 bytes, checksum: 7835be5cca9af3b1ec11e37200c2f1d3 (MD5)
Previous issue date: 2012 / Resumo: A penetração em massa de equipamentos eletrônicos de maior eficiência energética em residências está resultando em distorções significativas das formas de onda de tensão e corrente dos modernos sistemas de distribuição. Há uma necessidade crescente de técnicas que permitam determinar o impacto coletivo destas cargas residenciais nos níveis de distorção harmônica. Tais técnicas podem ser usadas, por exemplo, para prever os impactos da adoção em massa de lâmpadas fluorescentes compactas. Nesse contexto, esta tese de doutorado propõe uma técnica probabilística para avaliação do impacto dessas cargas residenciais na qualidade de energia tanto no primário como no secundário dos sistemas de distribuição de energia elétrica. O método modela individualmente e de forma estocástica as injeções harmônicas dos típicos eletrodomésticos a partir da distribuição da probabilidade de que cada aparelho seja ligado, a qual foi obtida a partir da pesquisa de dados de comportamento de carga. O resultado é um circuito elétrico equivalente harmônico variável no tempo representando uma casa residencial. Além disso, um modelo probabilístico para transformadores de distribuição foi desenvolvido através da combinação do transformador e das casas conectadas. Resultados de medições de campo confirmaram a validade da modelagem proposta. Em seguida, a metodologia proposta foi aplicada para investigar o impacto de tais cargas residenciais sobre a qualidade de energia dos sistemas de distribuição, tanto no primário como no secundário. Impactos como distorção harmônica na tensão e corrente; carregamento do transformador; elevação da tensão e corrente do neutro; interferência telefônica foram avaliados. A evolução dos impactos ao longo dos próximos anos, a partir de dados de tendências de mercado, também foi determinada. Adicionalmente, realizaram-se estudos para verificar a eficácia de duas soluções possíveis para mitigar distorção harmônica, sendo que a primeira consistiu em adotar os limites de emissão harmônica definidos pelo guia técnico IEC; e a segunda consistiu na instalação de filtros harmônicos no primário do sistema de distribuição / Abstract: The proliferation of electronic-based residential loads has resulted in significant harmonic distortion in the voltages and currents of distribution power systems. There is an urgent need for techniques that can determine the collective harmonic impact of these modern residential loads. Such techniques can be used, for example, to predict the harmonic effects of widespread adoption of compact fluorescent lights (CFLs). In response to this need, this PhD thesis proposes a versatile Monte Carlo simulation method for evaluating the potential impact of such residential loads on the harmonic levels of power distribution systems. The method models the random harmonic current injections of residential loads by simulating their operating states. This is done by determining the switch-on probability of a residential load based on load research results. The result is a time-varying harmonic equivalent circuit representing a residential house. By combining multiple residential houses supplied from a service transformer, a probabilistic model for service transformers is also derived. Field measurement results confirmed the validity of the proposed technique. The proposed methodology is applied to a typical distribution system for evaluating the impact of residential loads on several power quality aspects. The results of different case studies proved to be valuable in answering the following questions: (1) What are the potential power quality impacts of distributed nonlinear residential loads on primary and secondary power distribution systems? The example impacts include voltage distortion, zero sequence harmonics, neutral voltage/current rise, telephone interference, metering error, increased losses, overloading of distribution transformers. (2) How serious the impacts will become when more and more energy efficient appliances and consumer electronics penetrates into the residential loads? (3) If the consequence is of concern, what are the strategies and options available for utilities to manage the problem? / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
|
Page generated in 0.0747 seconds