Spelling suggestions: "subject:"anline reconstruction"" "subject:"bnline reconstruction""
1 |
Proximal structured sparsity regularization for online reconstruction in high-resolution accelerated Magnetic Resonance imaging / Algorithmes de structures paricmonieuses pour la reconstruction en-ligne d'image haute résolution en IRMEl Gueddari, Loubna 13 December 2019 (has links)
L'imagerie par résonance magnétique (IRM) est la technique d'imagerie médicale de référence pour sonder in vivo et non invasivement les tissus mous du corps humain, en particulier le cerveau.L'amélioration de la résolution de l'IRM en un temps d'acquisition standard (400µm isotrope en 15 minutes) permettrait aux médecins d'améliorer considérablement leur diagnostic et le suivi des patients. Cependant, le temps d'acquisition en IRM reste long. Pour réduire ce temps, la récente théorie de l'échantillonnage comprimée (EC) a révolutionné la façon d'acquérir des données dans plusieurs domaines dont l'IRM en surmontant le théorème de Shannon-Nyquist. Avec l'EC, les données peuvent alors être massivement sous-échantillonnées tout en assurant des conditions optimales de reconstruction des images.Dans ce contexte, les thèses de doctorat précédemment soutenue au sein du laboratoire ont été consacrées à la conception et à la mise en oeuvre de scénarios d'acquisition physiquement plausibles pour accélérer l'acquisitions. Un nouvel algorithme d'optimisation pour la conception de trajectoire non cartésienne avancée appelée SPARKLING pour Spreading Projection Algorithm for Rapid K-space samplING en est né. Les trajectoires SPARKLING générées ont conduit à des facteurs d'accélération allant jusqu'à 20 en 2D et 70 pour les acquisitions 3D sur des images à haute résolution pondérées en T*₂ acquises à 7 Tesla. Ces accélérations n'étaient accessibles que grâce au rapport signal/bruit d'entrée élevé fourni par l'utilisation de bobines de réception multi-canaux (IRMp). Cependant, ces résultats ont été obtenus au détriment d'une reconstruction longue et complexe. Dans cette thèse, l'objectif est de proposer une nouvelle approche de reconstruction en ligne d'images acquies par IRMp non cartésiennes. Pour atteindre cet objectif, nous nous appuyons sur une approche en ligne où reconstruction et acquisition s'entremèlent. Par conséquent, la reconstruction débute avant la fin de l'acquisition et un résultat partiel est délivré au cours de l'examen. L'ensemble du pipeline est compatible avec une implémentation réelle à travers l'interface Gadgetron pour produire les images reconstruites à la console du scanner.Ainsi, après avoir exposé la théorie de l'échantillonage comprimé, nous présentons l'état de l'art de la méthode dédiée à la reconstruction en imagerie multi-canaux. En particulier, nous nous concentrerons d'abord sur les méthodes d'autocalibration qui présentent l'avantage d'être adaptées à l'échantillonnage non cartésien et nous proposons une méthode simple mais efficace pour estimer le profil de sensibilité des différents cannaux. Cependant, en raison de leur dépendance au profil de sensibilité, ces méthodes ne sont pas adapatable à la reconstruction en ligne. Par conséquent, la deuxième partie se concentre sur la suppression des ces profils et celà grâce à l'utilisation de norme mixte promouvant une parcimonie structurée. Ensuite, nous adaptons différentes réularization basées sur la parcimonie structurée pour reconstruire ces images fortement corrélées. Enfin, la méthode retenue sera appliquée à l'imagerie en ligne. / Magnetic resonance imaging (MRI) is the reference medical imaging technique for probing in vivo and non-invasively soft tissues in the human body, notably the brain. MR image resolution improvement in a standard scanning time (e.g., 400µm isotropic in 15 min) would allow medical doctors to significantly improve both their diagnosis and patients' follow-up. However the scanning time in MRI remains long, especially in the high resolution context. To reduce this time, the recent Compressed Sensing (CS) theory has revolutionized the way of acquiring data in several fields including MRI by overcoming the Shannon-Nyquist theorem. Using CS, data can then be massively under-sampled while ensuring conditions for optimal image recovery.In this context, previous Ph.D. thesis in the laboratory were dedicated to the design and implementation of physically plausible acquisition scenarios to accelerate the scan. Those projects deliver new optimization algorithm for the design of advanced non-Cartesian trajectory called SPARKLING: Spreading Projection Algorithm for Rapid K-space samplING. The generated SPARKLING trajectories led to acceleration factors up to 20 in 2D and 60 for 3D-acquisitions on highly resolved T₂* weighted images acquired at 7~Tesla.Those accelerations were only accessible thanks to the high input Signal-to-Noise Ratio delivered by the usage of multi-channel reception coils. However, those results are coming at a price of long and complex reconstruction.In this thesis, the objective is to propose an online approach for non-Cartesian multi-channel MR image reconstruction. To achieve this goal we rely on an online approach where the reconstruction starts from incomplete data.Hence acquisition and reconstruction are interleaved, and partial feedback is given during the scan. After exposing the Compressed Sensing theory, we present state-of the art method dedicated to multi-channel coil reconstruction. In particular, we will first focus on self-calibrating methods that presents the advantage to be adapted to non-Cartesian sampling and we propose a simple yet efficient method to estimate the coil sensitivity profile.However, owing to its dependence to user-defined parameters, this two-step approach (extraction of sensitivity maps and then image reconstruction) is not compatible with the timing constraints associated with online reconstruction. Then we studied the case of calibration-less reconstruction methods and splits them into two categories, the k-space based and the domain-based. While the k-space calibration-less method are sub-optimal for non-Cartesian reconstruction, due to the gridding procedure, we will retain the domain-based calibration-less reconstruction and prove theirs for online purposes. Hence in the second part, we first prove the advantage of mixed norm to improve the recovery guarantee in the pMRI setting. Then we studied the impact of structured sparse induced norm on the reconstruction multi-channel purposes, where then and adapt different penalty based on structured sparsity to handle those highly correlated images. Finally, the retained method will be applied to online purposes. The entire pipeline, is compatible with an implementation through the Gadgetron pipeline to deliver the reconstruction at the scanner console.
|
Page generated in 0.0818 seconds