• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 2
  • 1
  • Tagged with
  • 14
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Conception préliminaire d'une orthèse modulaire pour aider les mouvements fonctionnels de la main

Faucher, Gabriel 30 November 2022 (has links)
La capacité d'utiliser ses mains est essentielle pour accomplir certaines activités de la vie quotidienne comme manger, boire ou écrire. Certains groupes d'individus ne sont toutefois pas en mesure d'accomplir ces activités sans assistance, ce qui peut grandement nuire à leur qualité de vie. Ces individus sont parfois en mesure de contrôler le mouvement de leur bras, mais pas nécessairement le mouvement de leur main et de leur poignet limitant leur capacité à saisir certains objets. L'objectif de ce projet est de concevoir une orthèse de main capable d'assister le mouvement de flexion et d'extension des doigts pour aider ces individus à prendre les objets du quotidien de manière autonome. Deux versions ont été conçues, soit une première seulement mécanique et une deuxième mécatronique. La première version utilise des ressorts pour assister le mouvement des doigts. Elle permet deux configurations, soit une première qui assiste les muscles fléchisseurs et une deuxième qui assiste les muscles extenseurs. Le même module est utilisé pour les deux configurations et pour choisir la bonne configuration, il suffit de positionner les ressorts dans la bonne orientation. En fonction des besoins de l'utilisateur, la force d'assistance peut être ajustée en changeant la position de la butée ou en modifiant les points d'attache de chaque ressort. La deuxième version utilise un moteur linéaire pour contrôler la flexion et l'extension des doigts. Le moteur linéaire peut également amplifier la force de préhension de l'utilisateur pour lui permettre de saisir, de manière autonome, certains objets du quotidien. L'intention de mouvement de l'utilisateur est détectée avec des capteurs EMG capables de détecter le signal électrique généré par les groupes musculaires responsables de ce mouvement. Le signal est alors traité par un algorithme de contrôle qui est basé sur la méthode « tout ou rien » et qui détermine la commande à envoyer au moteur linéaire. / Using one's hands to perform activities of daily living such as eating, drinking or writing is essential for living independently. However, for some people, it is not possible to perform these activities independently, which affect their quality of life. These people are sometimes able to control the movement of their arms, but not necessarily the movement of their hand and wrist. This project focus on the design of a hand orthosis capable of assisting the flexion and extension of the fingers to enhance the user's grasping capabilities. Two versions were designed. The first one is a mechanical solution and, the second one is a mechatronic solution. The first version uses springs to assist the movement of the fingers. It has two configurations, one that assists the flexor muscles and another one that assists the extensor muscles. The same module is used for both configurations and only the springs have to change orientation to switch between each configuration. The assistive force can be adjusted by changing the position of the stopper or by modifying the fixation points of each spring. The second version uses a linear motor to control finger flexion and extension. The linear motor can also enhance the grip strength of the user. The user's intention is detected with EMG sensors capable of detecting the electrical signal generated by the targeted muscles. The signal is then processed by an algorithm based on the "On-Off" method which controls the linear motor.
2

Orthèse électro-hydraulique pour l'analyse du contrôle de la marche

Noël, Martin January 2007 (has links)
No description available.
3

Analyse de la cinétique, cinématique et l’électromyographie du membre inférieur de personnes atteintes de la dysfonction du tendon tibial postérieur (DTTP) de stade léger à modéré avec l’influence de l’orthèse plantaire sur mesure et l’orthèse plantaire préfabriquée

Chicoine, Dominic 03 February 2021 (has links)
La dysfonction du tendon tibial postérieur (DTTP) affecte 3,3% des femmes de plus de 40 ans. Elle se caractérise par une dégénérescence du tendon tibial postérieur (tendinose). La biomécanique de cette population est marquée par une augmentation de l’éversion de l’arrière-pied et du moment de force en inversion à la cheville. L’orthèse plantaire (OP) diminue ces déficits biomécaniques chez la population asymptomatique. Cependant, aucune étude n’a isolé l’effet de l’OP sur la biomécanique du membre inférieur chez cette population. L’objectif de ce projet de recherche était de faire l’état des connaissances sur la DTTP et de mesurer l’effet de trois types d’OP sur la biomécanique de quatorze individus atteints de la DTTP ; OP préfabriquée, OP sur mesure et OP sur mesure varisée avec un biseau médial de 5° et un biseau calcanéen médial de 4 mm. La principale hypothèse était que l’OP sur mesure diminuerait les déficits retrouvés chez la population DTTP comparativement à l’OP préfabriquée. Pour ce faire, une analyse de la cinétique, de la cinématique et de l’activité musculaire à la marche du membre inférieur atteint ont été effectuées. Une diminution de l’angle d'éversion de l'arrière-pied, une diminution du moment d'inversion à la cheville et une augmentation du moment d’abduction du genou ont été observées avec des OP sur mesure par rapport au port de la chaussure et de l’OP préfabriquée (p <0.001). Les OP sur mesures pourraient être plus adaptées que les OP préfabriquées pour optimiser la biomécanique observée à l’articulation de la cheville chez la population DTTP. Cependant, les résultats montrent des effets se répercutant à l’articulation du genou qui pourraient être bénéfiques pour cette population. Une étude clinique, telle qu’un essai contrôlé randomisé, est requise afin de savoir si ces effets biomécaniques se traduiront en bénéfices cliniques pour les individus atteints d’une DTTP. / Posterior tibial tendon dysfunction (PTTD) affects 3.3% of women over the age of 40. It is characterized by the degeneration of the posterior tibial tendon (tendinosis). The biomechanics of this population is marked by an increased eversion of the hindfoot andankle inversion joint moment. Foot orthoses (FO) are more efficient to reduce those biomechanical features in the asymptomatic population. Also, FO reduce the pain associated with PTTD. However, no study has isolated the biomechanical effect of OP on this population. The aim of this research project was to synthesize knowledge on PTTD and determine the effect of three types of FO; prefabricated FO, custom FO and custom-varus FO with a 5 ° medial wedge and a 4 mm medial heel skive on the biomechanics of fourteen individuals with PTTD. The first hypothesis was that both custom FO will reduce the biomechanical deficits observed in PTTD population compared to prefabricated FO. To do so, a quantitative analysis of the gait on the affected lower limb of the kinematic, kinetic and muscular activity was conducted. A decreased in the angles of eversion of the hindfoot,a decreased ankle inversion moment and an increased knee abduction moment wereobserved with both custom FO compared to wearing shoes and prefabricated FO (p<0.001). Custom FO could be more appropriate than prefabricated FO to optimize the biomechanics of the lower limb observed at the ankle joint in PTTD population. However,clinicians should be careful when prescribing custom FO for PTTD since unwanted collateral biomechanical effects can be observed at the knee. A clinical study, such as arandomized controlled trial, is required to find out the clinical impact of those biomechanical effects.
4

SAMI, Services d'assistance mobiles et intelligents

Groussard, Pierre-Yves January 2012 (has links)
Au Canada, le nombre de personnes atteintes de troubles cognitifs n'est pas négligeable et les conséquences de ces troubles sur les activités de la vie quotidienne (AVQ) de ces personnes sont dramatiques. Suivant la sévérité des troubles, les personnes sont capables de réaliser leurs activités avec quelques difficultés ou sont totalement incapables de les faire, ce qui conduit souvent au placement de ces personnes dans des centres spécialisés. Ce placement, ainsi que le suivi de ces personnes, sont particulièrement onéreux pour la société. Pour cette raison, les gouvernements visent à favoriser des solutions de maintien à domicile. Une des pistes de solutions est de fournir aux personnes atteintes de troubles cognitifs un ensemble de services d'assistance technologiques, disponibles en tout temps et en tous lieux, capables de s'adapter aux différents outils technologiques présents dans l'environnement pour offrir une assistance continue. L'objectif de cette thèse est de concevoir une telle solution d'assistance en menant une recherche sur deux axes entrecroisés. Le premier axe concerne les solutions d'assistance d'un point de vue technologique, le second les aborde d'un point de vue plus clinique. Sur le plan technologique, à partir des solutions d'assistance déjà existantes ainsi que de leurs limitations, nous avons identifié un ensemble de services essentiels et les avons regroupés au sein de trois catégories. Nous présentons un modèle d'architecture logicielle pour la conception de ceux-ci visant à favoriser leur adaptation à différents contextes, leur évolution ainsi que l'intégration de nouveaux services. Enfin, nous présentons notre solution d'assistance baptisée SAMI. Au niveau clinique, nous montrons l'importance d'impliquer les personnes atteintes de troubles cognitifs, ainsi que leurs intervenants, tout au long du processus de conception de telles solutions. Nous présentons notre protocole de conception participative ainsi que sa mise en oeuvre dans le cadre de la conception de SAMI. La conception de cette solution a impliqué quatre patients ainsi que leurs intervenants professionnels et a été testée durant huit semaines. Les résultats montrent tout d'abord la possibilité de mettre en oeuvre de telles méthodes de conception, les patients ainsi que les intervenants ayant grandement participé tout au long du processus de conception. Ils montrent également la capacité des patients à apprendre à utiliser l'assistant élaboré ainsi que leur capacité à l'utiliser dans leur quotidien.
5

Utilisation d'une orthèse robotisée pour évaluer la spasticité des fléchisseurs plantaires pendant la marche chez les individus ayant subi une lésion médullaire

Labbé, Benoit 19 November 2021 (has links)
La spasticité affecte entre 67 et 78% des individus vivant avec une lésion médullaire (LM) d'origine traumatique, ainsi qu'entre 15 et 56% des individus ayant une LM non-traumatique. Ce phénomène s'identifie comme étant un désordre moteur caractérisé par une augmentation vélo-dépendante (vitesse-dépendante) du réflexe tonique d'étirement avec une exagération du réflexe ostéotendineux, résultant d'une hyperexcitabilité du réflexe d'étirement. L'impact de la spasticité des membres inférieurs sur la fonction locomotrice fait l'objet de vifs débats dans la littérature scientifique existante. Cette disparité pourrait être expliquée, en partie, par les limites des outils cliniques utilisés pour mesurer la spasticité. Les outils cliniques sont régulièrement basés sur une échelle ordinale de la résistance perçue par l'évaluateur lors d'un mouvement passif du segment évalué, ce qui soulève des questionnements quant aux qualités métrologiques de ces outils. Il a été suggéré qu'une évaluation de la spasticité basée sur des données neurophysiologiques, tel que le réflexe d'étirement, et effectuée pendant la marche, pourrait procurer une approche plus directe pour étudier la relation entre ce désordre et la fonction locomotrice. L'objectif principal de mes études de maîtrise consistait à décrire la réponse réflexe des muscles fléchisseurs plantaires (FP) à l'étirement, mesurée avec un protocole d'évaluation pendant la marche, chez des individus ayant subi une LM incomplète. Également, la relation entre la spasticité des FP et la fonction locomotrice a été étudiée. Pour atteindre ces buts, une orthèse robotisée électrohydraulique a été utilisée pour induire des étirements contrôlés des muscles FP, pendant la phase d'appui et la phase d'oscillation de la marche. Les résultats de cette étude pourront permettre de mieux comprendre le phénomène de la spasticité, et ainsi d'établir des bases solides pour justifier le développement et l'utilisation de protocoles d'évaluation de la spasticité basés sur des données neurophysiologiques ET effectués pendant la marche. À plus long terme, l'utilisation de ce type de protocole pourrait contribuer à démontrer l'efficacité de certaines interventions utilisées en physiothérapie ciblant la spasticité. / Spasticity affects approximately 67 to 78% of individuals living with a traumatic spinal cord injury (SCI), in addition to between 15 to 56% of individuals living with a non-traumatic SCI. This phenomenon is defined as a motor disorder characterized by a velocity-dependent increase in tonic stretch reflexes with exaggerated tendon jerks, resulting from hyperexcitability of the stretch reflex. Existing literature presents equivocal results regarding the impact of lower limb spasticity on locomotor function. These divergent results may be explained, at least partly, by the limitations of the clinical assessment tools used to measure spasticity. Clinical tools are regularly based on an ordinal scale and are focused on the perceived resistance to passive stretching, which raise questions about the metrological qualities of these tools. It has been suggested that an assessment of spasticity including neurophysiological data, such as stretch reflex (SR), performed during gait may provide a more direct approach to study the relationship between this disorder and locomotor function. The main objective of my master studies was to investigate plantarflexors SR response to stretching, using an assessment while walking among individuals living with an incomplete SCI. In addition, relationship between spasticity and locomotor function was studied. To achieve these goals, a robotic electrohydraulic orthosis was used to induce controlled plantarflexor stretches during the stance and swing phases of gait. Results of this study will allow to better understand spasticity, to establish solid justifications to develop and use assessment protocols based on neurophysiological data AND during gait. In the long term, the use of this type of assessment could contribute to demonstrating the effectiveness of interventions used in physical therapy targeting spasticity
6

Le contrôle sensorimoteur du pied lors de la course et de la contraction statique fatiguante / The sensorimotor control of the foot during running and tiring static contraction

Vie, Bruno 26 November 2013 (has links)
Le contrôle sensorimoteur du pied est le fondement des adaptations de l’Homme à son environnement. La station debout et la marche nécessitent l’intervention de toutes les composantes du contrôle sensorimoteur, les mécanorécepteurs plantaires renseignant le système nerveux central sur la position du corps dans l'espace. Notre travail de thèse a consisté en un premier temps à établir un protocole permettant de quantifier la sensation tactile plantaire qui nous a permis de nous intéresser à l’effet des orthèses plantaires sur la perception tactile plantaire. Nos résultats mettent en évidence chez la majorité de nos sujets, que les orthèses appliquées sur les seuls appuis rétrocapitaux augmentent la discrimination des plus faibles charges mécaniques après 30 jours de port de semelles. Ces variations dépendent de la position du pied lors de la station debout et du pattern de marche. Nous avons aussi exploré le contrôle moteur lors du maintien de la station debout et d’un exercice de course à vitesse maximale. Après un effort statique maximal recrutant de façon sélective les muscles inverseurs du pied (tibialis antérior, TA), les surfaces d’appui plantaires et la surface du trajet du barycentre augmentent, il existe une altération du réflexe myotatique dans le seul TA faisant suite à des signes de fatigue électromyographique (réduction de fréquence médiane) après appui maximal. Faisant suite à un effort dynamique maximal (course sur tapis roulant), nous observons les mêmes phénomènes : augmentation des surfaces d’appui plantaire et du trajet du barycentre des pressions, et diminution de la fréquence médiane dans le seul muscle TA aux vitesses de course les plus élevées. / The sensorimotor control of foot placement and motion plays a key role in the adaptive response of human being to his environment. The participation of both sensory and motor components is needed to control the foot placement during gait and posture and mechanoreceptors in the foot sole give major information on the body position. First, we established a protocol to quantify the sensation of foot sole pressure stimulation, which allowed us to examine the effects of metatarsal pads, and heel lifts in healthy subjects. We observed that 30-days of occupational activities with metatarsal pads elicited significant changes in sensation, lowering the threshold for the detection of the lowest pressure loads and, depending on the pattern of foot placement during upright standing and walking, modifying the global gain for the foot sensation. Second, we examined the consequences of fatiguing static contraction of foot invertor muscles (tibialis anterior or TA) and of maximal running exercise on a treadmill on post-test changes in foot placement using a baropodometer, maximal force production by TA. Power spectrum analyses of electromyographic (EMG) events were performed during both static and dynamic efforts and we also explored the myotatic reflexes through the recording of the tonic vibratory response (TVR) in foot muscles. Our results showed significant changes in post-test foot placement in the direction of foot eversion in both situations, significant decrease in maximal inversion force, a leftward shift of EMG spectrum in the sole TA muscle, indicating EMG signs of fatigue, and 4) significant reduction of TVR amplitude in the sole TA muscle after sustained static effort.
7

Caractérisation et modélisation des actions mécaniques des orthèses du genou

Pierrat, Baptiste 10 December 2013 (has links) (PDF)
L'articulation du genou est sujette à de nombreuses pathologies pouvant entraîner des instabilités. Les démarches thérapeutiques incluent communément le port d'orthèses, dans le but de stabiliser ou limiter les mouvements articulaires. Malgré une forte prescription, l'évaluation de ces dispositifs manque encore de standardisation.En lien avec des médecins et des industriels, différents outils ont été développés pour évaluer leur efficacité biomécanique. Un modèle éléments finis d'un membre inférieur appareillé a notamment permis d'étudier l'effet de divers paramètres de conception d'une genouillère sur les pressions exercées et sur sa capacité à limiter un mouvement pathologique. Ce modèle a servi à valider un banc de test pouvant contribuer à l'innovation et la certification. Afin d'appréhender les problèmes de confort, le glissement des orthèses sur la peau a été caractérisé par des mesures de champ. Enfin, leurs actions in vivo ont été mesurées à l'aide d'un arthromètre sur des patients présentant une laxité.Les résultats mettent en évidence l'importance des caractéristiques techniques des orthèses et la spécificité du patient sur leurs niveaux d'action. Ainsi, il est possible de cibler des pathologies en jouant sur certains facteurs. Cependant, comparé aux structures de stabilisation passive (ligaments), le rôle des orthèses s'avère limité aux conditions de faibles sollicitations mécaniques. Néanmoins, leurs effets actifs et proprioceptifs (contrôle neuro-musculaire) seraient également à considérer.Ces outils s'avèrent complémentaires ; ils ouvrent la voie à des démarches d'évaluation standardisées et pourront également aider au développement de nouveaux produits.
8

Etudes des effets du port d'orthèses plantaires à dominante biomécanique ou proprioceptive sur la régulation posturale et la stratégie neurale chez des patients souffrant d'aponévrosite plantaire ou de gonalgie / Study of effects of the wearing plantar orthoses based on biomechanical or proprioceptive principles on postural regulation and neural strategy in patients suffering from plantar fasciitis or knee pain

Moyne-Bressand, Sébastien 15 December 2017 (has links)
Les gonalgies et les aponévrosites plantaires représentent la majorité des motifs de consultations d’un cabinet de podologie. Les patients souffrant de ces pathologies ressentent des douleurs au niveau du genou ou du pied qui peuvent être invalidantes. Bien que le port d’orthèses plantaires représente un traitement conservateur efficace, la prescription de ce traitement repose sur une connaissance empirique des effets de ce dernier. Le but de ce travail était donc d’étudier les effets des semelles orthopédiques à dominante biomécanique (modifiant la posture) ou proprioceptive (stimulant les capteurs de la sole plantaire) sur les modifications de la stratégie neurale chez les patients souffrant de ces pathologies et de déterminer quels pouvaient être les liens avec la diminution de la douleur ressentie. Pour cela, nous avons procédé à une évaluation de la douleur, un examen de la marche, un examen stabilométrique et des enregistrements électrophysiologiques (réflexes mesurés au repos et lors d’une contraction musculaire volontaire). L’évolution de ces différents paramètres a été mesurée après trois, six et neuf semaines de port d'orthèses plantaires. Les résultats obtenus ont été comparés à ceux recueillis chez des patients témoins indemnes de toute pathologie.Même si les résultats obtenus lors de ces études ne sont pas aussi concluants que nous l’aurions souhaité et que de nombreuses questions restent encore en suspend, ce travail a permis toutefois d’ouvrir au domaine de la podologie un champ de recherche jusque-là peu ou pas exploré. / Knee pain and plantar fasciitis represent most of the reasons for consultation of a podiatrist. Patients with these pathologies experience knee or foot pain that can be disabling. Although the use of foot orthoses is an effective conservative treatment, its prescription is based on an empirical knowledge of its effects. The aim of this study was to investigate the effects of foot orthoses based on biomechanical (modifying the posture) or proprioceptive (stimulating sensors of the plantar sole) principles on neural strategy changes in suffering patients and to determine the links with the decrease in perceived pain. For this, we performed a pain assessment, walking and stabilometric examination and electrophysiological recordings (reflexes measured at rest and during voluntary muscle contraction). The evolution of these different parameters was measured after three, six and nine weeks of wearing foot orthoses. The results obtained were compared with those obtained in control patients free from any pathology.Although the results of these studies are not as conclusive as we would have liked and many questions remain unresolved, this work has opened up to the podiatry a field of research until then little or not explored.
9

Évaluation des effets cinématiques et dynamiques induits par le port d’orthèses plantaires lors de la marche / Evaluation of kinematic and dynamic effects induced by foot orthotics during walking

Delacroix, Sébastien 16 December 2014 (has links)
La connaissance des effets biomécaniques induits par les orthèses plantaires représente un enjeu important afin de faire reconnaitre le rôle du podologue dans le traitement des pathologies ostéo-articulaires et musculo-tendineuses de l'appareil locomoteur. Ainsi, ce travail de thèse consiste à modéliser, par la biomécanique, l'appareil locomoteur afin d'évaluer les effets du port des orthèses plantaires durant la marche. Avant toute chose, une étude méthodologique a été menée afin de vérifier la reproductibilité des données biomécaniques de la marche. Les principaux résultats montrent que ces données biomécaniques peuvent présenter une variabilité importante, principalement causée par des erreurs de positionnement des capteurs sur le sujet, rendant parfois difficile l'interprétation clinique. Toutefois, la deuxième partie de cette étude a montré que l'utilisation d'une méthodologie de correction segmentaire à partir d'une position statique imposée permettait de réduire cette variabilité. Une étude clinique a donc été menée sur les répercussions de l'utilisation d'une orthèse plantaire de supination sur la correction instantanée du pied valgus. Les principales conclusions montrent que les données cinématiques et dynamiques, notamment du pied et de la cheville, sont impactées. Enfin, afin de démontrer l'intérêt d'utiliser la méthodologie de correction segmentaire pour l'interprétation des effets biomécaniques du traitement par orthèses plantaires à plus ou moins long terme, deux cas cliniques ont été analysés, l'un concernait un patient atteint d'un syndrome de loge de la jambe et l'autre d'une gonarthrose. Les principales conclusions indiquent que les orthèses plantaires ont une action sur des pathologies de la cheville et du genou mais que l'interprétation de cette action peut être erronée si la variabilité des données biomécaniques de la marche n'est pas prise en considération / The knowledge of the biomechanical effects induced by foot orthotics is an important issue in order to recognize the role of the podiatrist in the treatment of osteoarticular and musculotendinous disorders of the musculoskeletal system. So, this work consists in modeling, by the biomechanics, the musculoskeletal system to assess the effects of wearing foot orthotics during walking. A first study was conducted to check the reproducibility of gait biomechanical data through two different sessions. The results show that these biomechanical data may show significant variability, mainly caused by errors in the positioning of sensors on the subject, making it difficult clinical interpretation. However, the second part of this study showed that the use of a methodology for segmental correction, from a static position imposed, allowed reducing this variability. Thus, a study was conducted on the impact of the use of supinated foot orthotics on immediate correction of valgus foot. The main findings show that the kinematic and dynamic data, notably the foot and ankle, are impacted. Before being able to estimate if this correction lasts over time, a second study was conducted. Thus, to demonstrate the benefits of using this methodology for the interpretation of the biomechanical effects of treatment with foot orthotic in the longer term, two clinical cases were analyzed, one involved a patient with compartment syndrome of the leg and the other with knee osteoarthritis. The main findings indicate that the insoles have an impact on diseases of the ankle and knee but that the interpretation of these actions may be wrong if the variability of gait biomechanical data is not considered
10

Etude biomécanique in vivo de la fonction veineuse et lymphatique normale et pathologique / In vivo biomechanical evaluation of normal and pathological venous and lymphatic function in human

Mestre, Sandrine 20 September 2017 (has links)
La prise en charge de l’insuffisance veineuse chronique (IVC) et du lymphœdème repose, traditionnellement, sur des méthodes de compression fondées sur des concepts généralement admis mais insuffisamment éprouvés. Le Projet « Phlébosthène », initié en 2010, comporte le développement et l’application d’outils d’étude biomécanique quantitative de l’œdème et des troubles fonctionnels veineux. Les études n°1 et 2 reposaient sur la volumétrie par mesures étagées de circonférence du membre supérieur chez des patientes présentant un lymphœdème. Elles ont montré la valeur prédictive des variations de volume obtenues par la phase intensive du traitement décongestif quant à l’évolution du lymphœdème à moyen terme et au risque de phénomène de rebond. L’étude n°3 a validé la volumétrie de membre par caméra laser 3D chez des sujets sains et des patients souffrant d’insuffisance veineuse chronique du membre inférieur, en comparaison à la volumétrie par déplacement d’eau, méthode de référence, avec l’avantage majeur de quantifier le volume du pied et de la main. L’étude n°4 comportait, au membre inférieur, la mesure des pressions d’interface, intraveineuse, et intramusculaire sans et avec orthèse de compression dégressive de force 2 et 3, et avec orthèse de compression progressive, au repos, lors d’une manœuvre de flexion-extension du pied en position allongée, et lors d’une manœuvre de haussement sur la pointe des pieds en position debout. L’échographie avec mesure de la force d’appui sur la sonde et analyse automatique d’image calculant l’aire veineuse permettait de déterminer la courbe force / aire d’une veine superficielle et d’une veine profonde du mollet en position allongée et debout. Nous avons inclus 57 patients souffrant d’IVC (21 au stade C1s, 18 au stade C3, et 18 au stade C5 selon la classification CEAP), et 54 sujets sains témoins (18 sédentaires, 18 actifs, 18 sportifs) appariés. Les mesures de pression intraveineuse et intramusculaire ont été réalisées chez un tiers des patients et sujets sains. Le traitement des données échographiques (1776 séquences) étant en cours, nous ne pouvons présenter que des résultats préliminaires et partiels. Les pressions d’interface évoluaient conformément aux attentes, atteignant des valeurs plus élevées sous compression de force 2 que sans compression, sous compression de force 3 que de force 2, et sous compression progressive que sous compression de force 2 ou 3. La compression progressive ne se distinguait nettement des compressions dégressives qu’au niveau du mollet et non de la cheville. Les pressions d’interface étaient généralement plus élevées, sous compression, chez les témoins et les patients au stade C5, et, à un moindre degré, au stade C3, que chez les patients au stade C1s. La pression intraveineuse variait en fonction de la posture et du mouvement et était corrélée à la taille du sujet et sa longueur de jambe en orthostatisme ainsi qu’avec le stade clinique d’IVC. La pression intramusculaire évoluait parallèlement à la compression. Les boucles force / aire veineuse montraient une hystérésis caractéristique, décrivant donc la viscoélasticité des veines examinées. L’analyse complète des résultats permettra de comparer les différentes orthèses de compression et leur effet sur la biomécanique veineuse des sujets sains et pathologiques, avec des données quantitatives sur les caractéristiques viscoélastiques des veines. Nous pourrons évaluer l’effet de l’activité physique en comparant les sujets sédentaires, actifs, et sportifs. L’objectif est, à terme, de produire un modèle mathématique permettant, à partir d’un ensemble limité de données obtenues de façon non-vulnérante, de prédire l’effet des différentes modalités de compression sur la biomécanique veineuse de façon à pouvoir déterminer, grâce à la description géométrique tridimensionnelle du membre, les paramètres individuels optimaux de compression. / The conventional treatment of chronic venous insufficiency (CVI) and lymphedema is based upon mechanical compression, relying on generally admitted but insufficiently proven concepts. The " Phlebosthene " project, initiated in 2010, involves the development and implementation of innovative tools for the quantitative biomechanical evaluation of edema and venous disorders. Studies #1 and #2 were based on the calculation of the upper limb volume by serial circumference measurements in patients with lymphedema. They demonstrated the predictive value of volume variations during the intensive phase of decongestive therapy as for the medium-term outcome and the risk of rebound phenomenon. Study #3 validated segmental limb volumetry by 3D laser scanning in healthy subjects and in patients with lower limb CVI, in comparison with water displacement (reference method), with the major advantage of quantifying the volume of the foot and toes. Study #4 included the measurement, at the lower limb, of interface, intravenous, and intramuscular pressure without and with compression stockings, comparing force 2 and force 3 graduated stockings with so-called progressive compression. Measurements were performed at rest, during flexion-extension movements of the foot while the subject was lying supine, and during a tip-toe test in the standing position. Synchronously recorded B-mode sonography with automatic image analysis allowed calculating the venous area and provided force / area curves of superficial and deep calf veins in the supine and in the standing position. We included 57 patients with CVI (21 at the C1s, 18 at the C3 and 18 at the C5 stage of CVI according to the CEAP classification), and 54 matched healthy controls (18 sedentary, 18 active, 18 sportive). Intravenous and intramuscular pressure measurements were performed in one third of patients. As the processing of the 1776 B-mode sonographic sequences is still underway, we can only offer here partial and preliminary results. Interface pressures evolved as expected, reaching higher values under graduated force 2 compression stockings than without compression, under graduated force 3 than force 2 compression, and under progressive than under graduated compression. Progressive compression clearly distinguished itself from graduated compression only at the calf but not at the ankle level. Interface pressures were generally higher, under compression, in controls and in patients with IVC at the C5 stage, and, to a lesser degree, at the C3 stage, than in patients at the C1s stage. Intravenous pressure varied with posture and movement and correlated with the subject’s size and leg length in orthostatic position, and with the CVI stage. The force / area curves of superficial and deep calf veins exhibited a characteristic hysteresis, yielding viscoelasticity information. When the database will be complete and consolidated, we will be able to compare different compression stockings and their effect on the venous biomechanics of healthy and pathological subjects, providing quantitative data on the viscoelastic characteristics of superficial and deep veins. We will also be able to assess the effect of physical activity on venous biomechanics by comparing sedentary, active, and sportive subjects. The confrontation of interface, intravenous, and intramuscular pressures with these biomechanical data will provide a mathematical model using a limited set of data obtained by simple and non-invasive measurements to predict the effect of compression stockings on the biomechanics of superficial and deep veins, in order to determine, with the help of 3D laser scanning, the optimal individual compression settings.

Page generated in 0.0246 seconds