21 |
Tooth movement caused by a loop lingual arch wire as measured on two test models of the mandibular dental arch a thesis submitted in partial fulfillment ... in pedodontics ... /Carlson, George Thomas. January 1973 (has links)
Thesis (M.S.)--University of Michigan, 1973.
|
22 |
Tensile properties of heat-manipulated stainless steel orthodontic wires a thesis submitted in partial fulfillment ... orthodontics /Ponitz, Robert J. January 1955 (has links)
Thesis (M.S.)--University of Michigan, 1955.
|
23 |
The effect of section size and shape on the mechanical properties of stainless steel orthodontic wire a thesis submitted in partial fulfillment ... orthodontics /Teetzel, James H. January 1953 (has links)
Thesis (M.S.)--University of Michigan, 1953.
|
24 |
An evaluation of a potentially superior type of stainless steel for orthodontic wires a dissertation [sic] submitted in partial fulfillment ... orthodontics /Slesnick, Harry J. January 1963 (has links)
Thesis (M.S.)--University of Michigan, 1963.
|
25 |
An in-vitro investigation of frictional resistance of self-ligating and ceramic brackets when subjected to different ligation methods and tipping anglesBovenizer, Todd S., January 2006 (has links)
Thesis (M.S.)--West Virginia University, 2006. / Title from document title page. Document formatted into pages; contains x, 97 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 69-76).
|
26 |
Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis / Evaluation of the force generated by gradual deflection of orthodontic wires in conventional mettalic, esthetic and self-ligated bracketsManoela Fávaro Francisconi 21 July 2014 (has links)
PROPOSIÇÃO: O objetivo deste trabalho foi avaliar a força gerada pela deflexão de fios ortodônticos de Nitinol associados a diferentes tipos de braquetes por meio da avaliação dos valores da força através do aumento gradual do calibre e da deflexão dos fios e comparação entre as distintas combinações, nas diferentes deflexões. MATERIAL E MÉTODOS: Os corpos de prova foram montados em um modelo de simulação clínica e avaliados em uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N e, como protocolo, foi seguida a norma ISO 15.841. Foram confeccionados cinco destes modelos para a colagem de cada conjunto de acessórios a serem testados: metálico (Mini Diamond), policarbonato com fibra de vidro e canaleta metálica (Spirit), safira (Inspire ICE) e os autoligáveis passivo (Damon Q/Ormco) e ativo (In-Ovation R/GAC). Para os testes, o dispositivo de acrílico que representava o incisivo central direito foi movimentado no sentido palatino-vestibular, com leituras das resistências geradas nas deflexões de 3; 2; 1 e 0,5mm, com velocidade constante de 2mm/min. Os resultados foram avaliados por meio da análise de variância (ANOVA) a dois e a um critério, havendo diferença significante, a análise comparativa das médias foi feita por meio do teste de Tukey (p<0,05). RESULTADOS: A força de desativação foi gradativamente maior, com o aumento do calibre dos arcos e maior deflexão, nos diferentes tipos de braquetes. Nas combinações entre os diferentes tipos de braquetes selecionados com os fios de Nitinol verificou-se que os braquetes autoligáveis foram os que apresentaram os resultados mais parecidos entre si, mantendo-os decrescentes conforme a deflexão diminuía. Já, entre os braquetes convencionais Mini Diamond, Spirit e Inspire ICE verificou-se que não existe um padrão em nenhuma deflexão estudada. CONCLUSÕES: A avaliação dos valores da força, através do aumento gradual do calibre e da deflexão dos fios, demonstrou que a mesma foi crescente em todos os braquetes avaliados. Os braquetes autoligáveis foram os que apresentaram os resultados mais constantes e previsíveis enquanto que nos demais essa característica não foi observada. / OBJECTIVE: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires, placed in different kinds of brackets by assessing strength values variation according to gradual increase in the diameter and the deflection of the wires, comparing the different combinations, in the different deflections. MATERIAL AND METHODS: Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10 N load cell and, as a protocol, ISO 15841. Five of these models were prepared, each one for the bonding of each set of accessories to be tested: metallic (Mini Diamond), reinforced polycarbonate with metallic slots (Spirit), sapphire (Inspire ICE), and passive (Damon Q/Ormco) and active self-ligated (In-Ovation R/GAC). For performing the tests, the acrylic device corresponding to the right central incisor was moved in the buccal-lingual direction, and values of resistance generated for 3, 2, 1 and 0.5mm deflections, at a constant speed of 2mm/min, were registered. Data were subjected to Oneand Two-way ANOVA; since significant differences were observed, comparative analysis of mean values was performed by Tukey\'s post hoc test (p<0.05). RESULTS: Elastic deflection results showed that deactivation force increased with increase in the diameter of the wires and deflection in the different brackets evaluated. For the combinations of the different types of brackets with the Nitinol wires, it was found that self-ligating brackets were those with the most similar results to each other, which decreased as the deflection was decreased. For Mini Diamond, Spirit and Inspire ICE conventional brackets there was no pattern for any of the deflections studied. CONCLUSIONS: Strength values evaluation according to gradual increase in the diameter and the deflection of the wires showed that it increased in all evaluated brackets. Self-ligating brackets were those which presented the most consistent and predictable results while for others kinds of brackets such pattern was not observed.
|
27 |
Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis / Evaluation of the force generated by gradual deflection of orthodontic wires in conventional mettalic, esthetic and self-ligated bracketsFrancisconi, Manoela Fávaro 21 July 2014 (has links)
PROPOSIÇÃO: O objetivo deste trabalho foi avaliar a força gerada pela deflexão de fios ortodônticos de Nitinol associados a diferentes tipos de braquetes por meio da avaliação dos valores da força através do aumento gradual do calibre e da deflexão dos fios e comparação entre as distintas combinações, nas diferentes deflexões. MATERIAL E MÉTODOS: Os corpos de prova foram montados em um modelo de simulação clínica e avaliados em uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N e, como protocolo, foi seguida a norma ISO 15.841. Foram confeccionados cinco destes modelos para a colagem de cada conjunto de acessórios a serem testados: metálico (Mini Diamond), policarbonato com fibra de vidro e canaleta metálica (Spirit), safira (Inspire ICE) e os autoligáveis passivo (Damon Q/Ormco) e ativo (In-Ovation R/GAC). Para os testes, o dispositivo de acrílico que representava o incisivo central direito foi movimentado no sentido palatino-vestibular, com leituras das resistências geradas nas deflexões de 3; 2; 1 e 0,5mm, com velocidade constante de 2mm/min. Os resultados foram avaliados por meio da análise de variância (ANOVA) a dois e a um critério, havendo diferença significante, a análise comparativa das médias foi feita por meio do teste de Tukey (p<0,05). RESULTADOS: A força de desativação foi gradativamente maior, com o aumento do calibre dos arcos e maior deflexão, nos diferentes tipos de braquetes. Nas combinações entre os diferentes tipos de braquetes selecionados com os fios de Nitinol verificou-se que os braquetes autoligáveis foram os que apresentaram os resultados mais parecidos entre si, mantendo-os decrescentes conforme a deflexão diminuía. Já, entre os braquetes convencionais Mini Diamond, Spirit e Inspire ICE verificou-se que não existe um padrão em nenhuma deflexão estudada. CONCLUSÕES: A avaliação dos valores da força, através do aumento gradual do calibre e da deflexão dos fios, demonstrou que a mesma foi crescente em todos os braquetes avaliados. Os braquetes autoligáveis foram os que apresentaram os resultados mais constantes e previsíveis enquanto que nos demais essa característica não foi observada. / OBJECTIVE: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires, placed in different kinds of brackets by assessing strength values variation according to gradual increase in the diameter and the deflection of the wires, comparing the different combinations, in the different deflections. MATERIAL AND METHODS: Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10 N load cell and, as a protocol, ISO 15841. Five of these models were prepared, each one for the bonding of each set of accessories to be tested: metallic (Mini Diamond), reinforced polycarbonate with metallic slots (Spirit), sapphire (Inspire ICE), and passive (Damon Q/Ormco) and active self-ligated (In-Ovation R/GAC). For performing the tests, the acrylic device corresponding to the right central incisor was moved in the buccal-lingual direction, and values of resistance generated for 3, 2, 1 and 0.5mm deflections, at a constant speed of 2mm/min, were registered. Data were subjected to Oneand Two-way ANOVA; since significant differences were observed, comparative analysis of mean values was performed by Tukey\'s post hoc test (p<0.05). RESULTS: Elastic deflection results showed that deactivation force increased with increase in the diameter of the wires and deflection in the different brackets evaluated. For the combinations of the different types of brackets with the Nitinol wires, it was found that self-ligating brackets were those with the most similar results to each other, which decreased as the deflection was decreased. For Mini Diamond, Spirit and Inspire ICE conventional brackets there was no pattern for any of the deflections studied. CONCLUSIONS: Strength values evaluation according to gradual increase in the diameter and the deflection of the wires showed that it increased in all evaluated brackets. Self-ligating brackets were those which presented the most consistent and predictable results while for others kinds of brackets such pattern was not observed.
|
28 |
"Relação entre força e deflexão na ativação e desativação de fios ortodônticos de níquel-titânio" / Relation of forces and deflections during loading and unloading orthodontic nickel-titanium wiresGhersel, Herbert 18 November 2005 (has links)
O objetivo da presente pesquisa foi avaliar o comportamento da força em função da deflexão na ativação e desativação de fios ortodônticos de níquel-titânio, de secção circular (.016"). Ensaiaram-se três marcas de fio (Forestadent, GAC e Morelli). As temperaturas de ensaio foram três (32, 37 e 42ºC). As ativações máximas foram até 1, 2, 3 e 4mm. O espécime de ensaio consistiu de uma placa de resina acrílica, sobre a qual eram fixados cilindros metálicos por meio de parafusos, simulando dentes, com distribuição semelhante aos dentes naturais. Sobre os cilindros foram cimentados os bráquetes (distância de 8mm entre eles). Sobre os bráquetes era fixado, conforme clinicamente, o arco do fio em ensaio. O dente" correspondente ao incisivo central era liberado (desparafusado) para poder se deslocar livremente no sentido vestíbulo-lingual durante os ensaios e o fio poder sofrer a deflexão. O conjunto era levado à máquina de ensaio (Instron), com câmara de temperatura controlada. Durante o ensaio a velocidade de deslocamento para a deflexão foi de 0,5mm/min. Durante a ativação e desativação as forças foram registradas de 0,10 em 0,10mm de deflexão. Por meio de software esses valores eram impressos numericamente e em gráficos da força em função da ativação/desativação. Com 4 ativações máximas, 3 marcas de fios e 3 temperaturas obtiveram-se 36 condições experimentais e com 5 repetições (n=5) foram feitos 180 ensaios. Os gráficos obtidos mostraram uma não linearidade entre força e deflexão e com ativação de 1 e 2mm não foi detectado platô de superelasticidade, mas que foi observado na desativação, das ativações máximas de 3 e 4mm. Dos gráficos e tabelas foram extraídos valores específicos para serem analisados e comparados: 1) força máxima de ativação; 2/3) diminuição da força na desativação de 0,20mm e 0,70mm (esta só na ativação de 3 e 4mm); 4/5) extensão e forças no platô (apenas nas ativações máximas de 3 e 4mm); 6/7/8) desativação até alcançar 50g de força, a partir de 0,80 e 1,80mm (ativações de 1 e 2mm), ou no final dos platôs (ativações de 3 e 4mm), a força ao iniciar-se a desativação, afastamento da origem ao registrar 50g de força; 9) deformação permanente ao atingir a força zero. As principais conclusões foram: a força de ativação máxima aumentou com o aumento desta e da temperatura, o material Morelli apresentou a menor e o GAC a maior; a diminuição da força máxima foi tanto maior quanto maior a ativação; apenas as ativações até 3 e 4mm apresentaram platôs de superelasticidade e que foram bem mais extensos na ativação de 4mm, que por sua vez apresentaram menor força; em todos os ensaios for observada deformação permanente / The purpose of this study was to evaluate the behaviour of force as function of loading and unloading orthodontic nickel-titanium wires. Three defferent brands (Forestadent, GAC and Morelli) were tested. Testing temperature were 32, 37 and 42 o C. Loading were up to 1, 2, 3 and 4mm deflection. Specimens consisted of a acrylic base where were fixed metallic cylinders simulating teeth. Over the teeth were fixed brackets to maintain arch wire in position. Tooth corresponding to central incisor was loosened and at the correspondig bráquete was applied the force in an Instron equipment, with temperature control. Head speed was 0.5mm/min. During loading and unloading forces were read every 0.10mm deflection and registered. The pair values of forces and deflections were also plotted as graphs. With 4mm maximum loading, 3 brands and 3 temperatures were obtained 36 experimental conditions and with 5 repetitions (n=5) were performed 180 tests. Graphs showed that there is no linearity between forces and deflection and with loading up to 1 and 2mm was not obtained the formation of superelasticity plateaus. But they were observed with 3 and 4mm deflections. From the graphs and registered numerical values for each specimen were selected special values to be analysed: 1) maximum loading force; 2/3) force decrease during unloading 0.20 and 0.70mm (the last only at 3 and 4mm activation); 4/5) exte nsions and forces at plateaus (only for 3 and 4mm activations); 6/7/8) extension until 50g force, since 0.80 and 1.80mm (respectively activation up to 1 and 2mm), or ends of plateau (3 and 4mm activation). In these conditions, the force at beginning unloading. Distance of origin at register 50g force; 9) permanent deformation at zero force. The main conclusions were: maximum loading forces increase with deflection and temperature increases, and brand Morelli presented the smallest force and GAC the greatest; the decrease of forces with unloading was as larger as activation force; only the activation until 3 and 4mm presented superelasticity plateaus, and was longer with 4mm activation, but it presented lower force at plateaus; in all tests was noted permanent deformation
|
29 |
Propriedades mecânicas e avaliação microscópica de fios ortodônticos de niti revestidos por polímeros / Mechanical properties and microscopic avaliation wire niti coated in polymersFerreira, Gaudyer Castro Di 24 March 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-23T11:24:55Z
No. of bitstreams: 2
Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-23T11:27:08Z (GMT) No. of bitstreams: 2
Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-23T11:27:08Z (GMT). No. of bitstreams: 2
Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-03-24 / The objective of the study was to analyze the mechanical properties and
analyze the surface of the wires coated polymers.
Methods: We used the pre-contoured wires study with dimension of 0.014 "Nickel-
Titanium (NiTi) brands: Tecident orthodontic equipment Ltda (São Carlos, São Paulo
Brazil), TP Orthodontics (Indiana, USA), Trianeiro ( Rio Claro, São Paulo Brazil) and
NiTi wire Morelli (Sorocaba, Sao Paulo Brazil) as a control group. The yarns were
randomly divided into 11 groups (n = 6) .There were carried deflection test. The yarns
were immersed in artificial saliva for a period of 30 to 60 days to corrode. After the wire
corrosion were also submitted for the analysis of Scanning Electron Microscopy (SEM).
Results: We used the ANOVA analysis of variance, which were statistically significant
differences between the tested wire and the controle.Foram group observed
imperfections on the surfaces of all the wire and the wire TP Orthodontics showed the
greatest changes.
Conclusions: The polymeric coating appears to be responsible for the mechanical
surface change and the NiTi wires. / O objetivo do estudo foi analisar as propriedades mecânicas e analisar a
superfície, dos fios revestidos por polímeros.
Materiais e métodos: Foram utilizados no estudo fios pré-contornados com dimensão
de 0.014” de Niquel-Titânio (NiTi) das marcas: Tecident Equipamento Ortodonticos
Ltda(São Carlos,São Paulo Brasil), TP Orthodontics (Indiana, EUA) , Trianeiro (Rio
Claro, São Paulo Brasil) e fio NiTi Morelli ( Sorocaba, São Paulo Brasil) como grupo
controle. Os fios foram divididos aleatoriamente em 11 grupos (n=6).Foram realizado o
teste de deflexão. Os fios foram imersos em saliva artificial por um período de 30 e 60
dias,para sofrer corrosão. Após a corrosão os fio também foram submetidos para a
análise de Microscopia Eletrônica de Varredura (MEV).
Resultados:Foi utilizado o teste de variância ANOVA, onde foram observadas
diferenças estatisticamente significantes entre os fios testados e os do grupo
controle.Foram observadas imperfeições nas superfícies de todos os fio sendo que o
fio da TP Orthodontics apresentou as maiores alterações.
Conclusões: O revestimento polimérico parece ser o responsável pelas alterações
mecânicas e da superfície dos fios de NiTi.
|
30 |
A comparative study of extraction treatment efficiency using conventional edgewise brackets and self-ligating bracketsCox, Stan C. January 2008 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2008. / Title from first page of PDF file (viewed May 30, 2008). Includes bibliographical references.
|