Spelling suggestions: "subject:"fenômenos mecânicos"" "subject:"fenômenos ecânicos""
1 |
Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis / Evaluation of the force generated by gradual deflection of orthodontic wires in conventional mettalic, esthetic and self-ligated bracketsManoela Fávaro Francisconi 21 July 2014 (has links)
PROPOSIÇÃO: O objetivo deste trabalho foi avaliar a força gerada pela deflexão de fios ortodônticos de Nitinol associados a diferentes tipos de braquetes por meio da avaliação dos valores da força através do aumento gradual do calibre e da deflexão dos fios e comparação entre as distintas combinações, nas diferentes deflexões. MATERIAL E MÉTODOS: Os corpos de prova foram montados em um modelo de simulação clínica e avaliados em uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N e, como protocolo, foi seguida a norma ISO 15.841. Foram confeccionados cinco destes modelos para a colagem de cada conjunto de acessórios a serem testados: metálico (Mini Diamond), policarbonato com fibra de vidro e canaleta metálica (Spirit), safira (Inspire ICE) e os autoligáveis passivo (Damon Q/Ormco) e ativo (In-Ovation R/GAC). Para os testes, o dispositivo de acrílico que representava o incisivo central direito foi movimentado no sentido palatino-vestibular, com leituras das resistências geradas nas deflexões de 3; 2; 1 e 0,5mm, com velocidade constante de 2mm/min. Os resultados foram avaliados por meio da análise de variância (ANOVA) a dois e a um critério, havendo diferença significante, a análise comparativa das médias foi feita por meio do teste de Tukey (p<0,05). RESULTADOS: A força de desativação foi gradativamente maior, com o aumento do calibre dos arcos e maior deflexão, nos diferentes tipos de braquetes. Nas combinações entre os diferentes tipos de braquetes selecionados com os fios de Nitinol verificou-se que os braquetes autoligáveis foram os que apresentaram os resultados mais parecidos entre si, mantendo-os decrescentes conforme a deflexão diminuía. Já, entre os braquetes convencionais Mini Diamond, Spirit e Inspire ICE verificou-se que não existe um padrão em nenhuma deflexão estudada. CONCLUSÕES: A avaliação dos valores da força, através do aumento gradual do calibre e da deflexão dos fios, demonstrou que a mesma foi crescente em todos os braquetes avaliados. Os braquetes autoligáveis foram os que apresentaram os resultados mais constantes e previsíveis enquanto que nos demais essa característica não foi observada. / OBJECTIVE: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires, placed in different kinds of brackets by assessing strength values variation according to gradual increase in the diameter and the deflection of the wires, comparing the different combinations, in the different deflections. MATERIAL AND METHODS: Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10 N load cell and, as a protocol, ISO 15841. Five of these models were prepared, each one for the bonding of each set of accessories to be tested: metallic (Mini Diamond), reinforced polycarbonate with metallic slots (Spirit), sapphire (Inspire ICE), and passive (Damon Q/Ormco) and active self-ligated (In-Ovation R/GAC). For performing the tests, the acrylic device corresponding to the right central incisor was moved in the buccal-lingual direction, and values of resistance generated for 3, 2, 1 and 0.5mm deflections, at a constant speed of 2mm/min, were registered. Data were subjected to Oneand Two-way ANOVA; since significant differences were observed, comparative analysis of mean values was performed by Tukey\'s post hoc test (p<0.05). RESULTS: Elastic deflection results showed that deactivation force increased with increase in the diameter of the wires and deflection in the different brackets evaluated. For the combinations of the different types of brackets with the Nitinol wires, it was found that self-ligating brackets were those with the most similar results to each other, which decreased as the deflection was decreased. For Mini Diamond, Spirit and Inspire ICE conventional brackets there was no pattern for any of the deflections studied. CONCLUSIONS: Strength values evaluation according to gradual increase in the diameter and the deflection of the wires showed that it increased in all evaluated brackets. Self-ligating brackets were those which presented the most consistent and predictable results while for others kinds of brackets such pattern was not observed.
|
2 |
Avaliação da força gerada pela deflexão gradual de fios ortodônticos em braquetes convencionais metálicos, estéticos e autoligáveis / Evaluation of the force generated by gradual deflection of orthodontic wires in conventional mettalic, esthetic and self-ligated bracketsFrancisconi, Manoela Fávaro 21 July 2014 (has links)
PROPOSIÇÃO: O objetivo deste trabalho foi avaliar a força gerada pela deflexão de fios ortodônticos de Nitinol associados a diferentes tipos de braquetes por meio da avaliação dos valores da força através do aumento gradual do calibre e da deflexão dos fios e comparação entre as distintas combinações, nas diferentes deflexões. MATERIAL E MÉTODOS: Os corpos de prova foram montados em um modelo de simulação clínica e avaliados em uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N e, como protocolo, foi seguida a norma ISO 15.841. Foram confeccionados cinco destes modelos para a colagem de cada conjunto de acessórios a serem testados: metálico (Mini Diamond), policarbonato com fibra de vidro e canaleta metálica (Spirit), safira (Inspire ICE) e os autoligáveis passivo (Damon Q/Ormco) e ativo (In-Ovation R/GAC). Para os testes, o dispositivo de acrílico que representava o incisivo central direito foi movimentado no sentido palatino-vestibular, com leituras das resistências geradas nas deflexões de 3; 2; 1 e 0,5mm, com velocidade constante de 2mm/min. Os resultados foram avaliados por meio da análise de variância (ANOVA) a dois e a um critério, havendo diferença significante, a análise comparativa das médias foi feita por meio do teste de Tukey (p<0,05). RESULTADOS: A força de desativação foi gradativamente maior, com o aumento do calibre dos arcos e maior deflexão, nos diferentes tipos de braquetes. Nas combinações entre os diferentes tipos de braquetes selecionados com os fios de Nitinol verificou-se que os braquetes autoligáveis foram os que apresentaram os resultados mais parecidos entre si, mantendo-os decrescentes conforme a deflexão diminuía. Já, entre os braquetes convencionais Mini Diamond, Spirit e Inspire ICE verificou-se que não existe um padrão em nenhuma deflexão estudada. CONCLUSÕES: A avaliação dos valores da força, através do aumento gradual do calibre e da deflexão dos fios, demonstrou que a mesma foi crescente em todos os braquetes avaliados. Os braquetes autoligáveis foram os que apresentaram os resultados mais constantes e previsíveis enquanto que nos demais essa característica não foi observada. / OBJECTIVE: The purpose of this study was to evaluate the deflection forces of Nitinol orthodontic wires, placed in different kinds of brackets by assessing strength values variation according to gradual increase in the diameter and the deflection of the wires, comparing the different combinations, in the different deflections. MATERIAL AND METHODS: Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10 N load cell and, as a protocol, ISO 15841. Five of these models were prepared, each one for the bonding of each set of accessories to be tested: metallic (Mini Diamond), reinforced polycarbonate with metallic slots (Spirit), sapphire (Inspire ICE), and passive (Damon Q/Ormco) and active self-ligated (In-Ovation R/GAC). For performing the tests, the acrylic device corresponding to the right central incisor was moved in the buccal-lingual direction, and values of resistance generated for 3, 2, 1 and 0.5mm deflections, at a constant speed of 2mm/min, were registered. Data were subjected to Oneand Two-way ANOVA; since significant differences were observed, comparative analysis of mean values was performed by Tukey\'s post hoc test (p<0.05). RESULTS: Elastic deflection results showed that deactivation force increased with increase in the diameter of the wires and deflection in the different brackets evaluated. For the combinations of the different types of brackets with the Nitinol wires, it was found that self-ligating brackets were those with the most similar results to each other, which decreased as the deflection was decreased. For Mini Diamond, Spirit and Inspire ICE conventional brackets there was no pattern for any of the deflections studied. CONCLUSIONS: Strength values evaluation according to gradual increase in the diameter and the deflection of the wires showed that it increased in all evaluated brackets. Self-ligating brackets were those which presented the most consistent and predictable results while for others kinds of brackets such pattern was not observed.
|
3 |
Comportamento mecânico de implantes modificados na região de ápice : análise pelo método de elementos finitos, fotoelasticidade, torque de inserção e frequência de ressonância /Sciasci, Plínio. January 2017 (has links)
Orientador: Luís Geraldo Vaz / Resumo: A proposta deste estudo foi analisar o comportamento mecânico e a distribuição de forças de diferentes geometrias de ápice em implantes cilíndricos por meio de método de elementos finitos (MEF), fotoelasticidade, torque de inserção e frequência de ressonância. Foram usinados quatro tipos de implantes: sem corte apical (A), com corte apical bi-partido (B), corte apical tri-partido (C), corte apical quadri-partido (D) e um quinto (grupo controle) implante Titamax Ti Ex (Neodent, Curitiba, Paraná, Brasil) (E), todos com dimensões (4,1 X 11,0 mm) de plataforma hexagonal externa. Para o ensaio fotoelástico, blocos de acrílico (30X30X10mm) com um implante foram copiados com Borracha Silicone. Dentro de cada molde de silicone foi vertido resina fotoelástica semi-fexível. Para o ensaio fotoelástico duas situações foram simuladas: aplicação de carga axial de 1 kgf e em outro momento aplicação do torque de 10 N.cm. As fotografias realizadas no polariscópio circular foram transferidas para um computador para leitura dos parâmetros fotoelásticos no software powerpoint (Office 2010). Para o estudo de elementos finitos, o desenho dos implantes foram reproduzidos em CAD (computer Aided design) através do software Autodesk Inventor® (versão 2015, São Paulo, Brasil) e o bloco ósseo tipo IV de dimensões (2X2X2cm) foram posteriormente processados pelo software Rhinoceros v5.0 SR8 (McNeel North America, Seattle, WA, USA). As simulações foram executadas pelo software (Ansys Workbench 10.0, Swanso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to analyze the mechanical behavior and force distribution of five different implant designs using finite element method (FEM), photoelasticity, insertion torque and resonance frequency of different geometric modifications proposed for the apex region Of cylindrical implants. Four types of implants were machined: without apical cut (A), with a two-part apical cut (B), apical tri-split cut (C), apical cut quadri-split (D) and fifth group was composed by Titamax Ti Ex Neodent all with dimensions (4.1 X 11.0 mm). For the photoelastic test, acrylic blocks (30X30X10mm) with implant installed were copied with Blue ASB-10 Silicone Rubber (Polipox). Inside each silicone mold was poured semi-flexible photoelastic resin (Polipox). A titanium UCLA prosthetic intermediate was screwed onto the implant and a dental crown on (Ni-Cr) was fixed on the set. For the photoelastic test two situations were simulated: application of axial load of 1 kgf and torque of 10 N.cm. The photograph and the reading of the photoelastic parameters were performed in a circular polariscope. For the finite element study, the computerAided design (CAD) implants and a Type IV human bone block of dimensions (2X2X2cm) were processed by the software Rhinoceros v5.0 SR8 (McNeel North America, Seattle, WA, USA) At the Renato Archer Information Technology Center (CTI, Campinas, São Paulo - Brazil). The mechanical properties of the implant (titanium grade II) and normal bone type IV were obtai... (Complete abstract click electronic access below) / Doutor
|
4 |
Caracterização físico-química, mecânica e biológica de cimento autoadesivo aditivado com nanotubos de dióxido de titânio / Physical-chemical, mechanical and biological characterization of reinforcement self-adhesive resin cement titanium dioxide nanotubesTonello, Carla Müller Ramos 28 November 2016 (has links)
O objetivo desse estudo foi realizar a caracterização do cimento resinoso autoadesivo RelyX U200 aditivado de nanotubos de dióxido de titânio (nt-TiO2) em diferentes concentrações (0,3, 0,6, e 0,9% em peso) quanto às suas propriedades físico-químicas, mecânicas e biológica. Duas condições de polimerização foram analisadas: autopolimerizável (grupos: AC, A03, A06 e A09) e dual (grupos: DC, D03, D06 e D09). Para análise do grau de conversão foi utilizada a espectroscopia de infravermelho com transformada de Fourier com registro do espectro nos tempos de 3, 6, 9, 12 e 15 minutos. Os picos das bandas de comprimento de onda de 1638 cm-1 e de 1608 cm-1 foram identificados para cálculo do grau de conversão. Os dados foram submetidos à ANOVA de medidas repetidas seguido de comparações múltiplas de Tukey (=0,05). A análise de sorção e solubilidade foi realizada por meio da confecção de discos de cimento resinoso (10 mm ø × 2 mm) (n=8) monitorados quanto à sua massa depois de ciclos de hidratação/desidratação. A resistência à flexão em 3 pontos e módulo de elasticidade foram mensurados por meio de barras (2 × 2 × 25 mm) de cimento resinoso (n=10) levadas à máquina universal de ensaios. Para análise de Dureza Knoop utilizou-se microdurômetro com carga de 50g /10 segundos. Nos discos de cimento resinoso de 10 mm ø × 2 mm foram realizadas 5 endentações equidistantes 0,5mm e medidas em aumento de 50×. Para resistência de união ao cisalhamento, sobre discos de zircônia sinterizados foi aplicado o cimento resinoso (n=10) nas dimensões de 3 mm ø × 2 mm. Por meio de dispositivo foram levados à máquina universal de ensaios. Os dados encontrados de sorção e solubilidade e de cada propriedade mecânica foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Exceto para resistência ao cisalhamento que se utilizou o teste de comparação de Fischer (=0,05). Para viabilidade celular (n=8) foi realizado teste de MTT apenas na condição dual. Os grupos estudados foram: DC, D03, D06, D09, CP (controle positivo), CN (controle negativo). Após 24, 48 e 72 horas os níveis de absorbâncias foram analisados por meio de espectrofotometria no leitor de ELISA. Os dados foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Os resultados mostraram que a adição de nt-TiO2, independente da concentração, aumentou os valores de grau de conversão do cimento resinoso para a condição autopolimerizável e dual em todos os tempos estudados. Já para sorção e solubilidade não houve influência nos resultados da concentração de nanotubos inseridos e da condição de polimerização. Para resistência flexural, a adição de nt-TiO2 nas concentrações de 0,3% (A03) e 0,9% (A09) resultou em dados similares ao controle na condição dual (DC). O valor médio de módulo de elasticidade aumentou com a adição de 0,9% (A09), similar a todos os grupos da condição dual, em que adição de nt-TiO2 não influenciou os resultados. A adição de 0,6% (A06 e D06) e 0,9% (A09 e D09) de nt-TiO2 ao cimento aumentou os valores de dureza quando comparado aos grupos controle (AC e DC). Para resistência de união ao cisalhamento, a concentração de 0,3% de nt-TiO2 (A03 e D03) aumentou os valores quando comparado aos grupos A06, D06, A09 e D09 porém sem diferença para os grupos controle (AC e DC). Para viabilidade celular no período de 24h, os grupos D03, D06 e D09 obtiveram resultado similar ao grupo CP, já o grupo DC apresentou valores de absorbância inferiores ao CP, usado como parâmetro de comparação. Em 48 e 72h, todos os grupos experimentais não demonstraram diferença significativa em comparação ao grupo CP. O grupo CN apresentou diferença para os demais em todos dos tempos estudados. A adição de nt-TiO2 ao cimento resinoso autoadesivo representa uma estratégia promissora para potencializar suas propriedades físico-químicas e mecânicas sem prejuízo das propriedades biológicas. / The aim of this study was to characterize the self-adhesive resin cement RelyX U200 additive, titanium dioxide nanotubes (nt-TiO2), at different concentrations (0.3%, 0.6%, and 0.9% by weight) and to determine their physicochemical, mechanical and biological properties. Two polymerization conditions were analyzed: self-curing (groups AC, A03, A06 and A09) and dual-curing (groups DC, D03, D06 and D09). To analyze the conversion degree, Fourier transform infrared spectroscopy was used, and the spectrum was recorded at 3, 6, 9, 12 and 15 minutes. The peaks of the wavelength bands, 1638 cm-1 and 1608 cm-1, were identified to calculate the degree of conversion. The data were subjected to a repeated-measures ANOVA followed by a Tukey multiple-comparison test (=0.05). The sorption and solubility analysis was performed by making resin-cement discs (10 mm ø × 2 mm) (n=8) and monitoring their masses after the hydration/dehydration cycles. The 3-point flexural strength and the modulus of elasticity of resin-cement bars (2 × 2 × 25 mm) (n=10) were measured using a universal testing machine. The Knoop microhardness was analyzed with a load of 50 g and a time of 10 seconds. On each resin cement disc, 5 equidistant indentations of 0.5 mm were made, and the measures were increased by 50×. To test bonding shear strength, resin cement was applied to sintered zirconia discs (3 mm ø × 2 mm) (n=10). The bonded discs were then taken to the universal testing machine. Their sorption, solubility and each mechanical property were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The shear strength was submitted to a Fischer comparison test (=0.05). To test cell viability (n=8), a MTT assay was performed using only the dual-curing condition. The studied groups were: DC, D03, D06, D09, CP (positive control) and CN (negative control). After 24, 48 and 72 hours, the absorbance levels were analyzed using an ELISA spectrophotometry reader. The data were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The results showed that the addition of nt-TiO2, regardless of concentration, increased the conversion degree values for the self-curing resin cement and for the dual-curing at all times studied. The sorption and solubility were not influenced by the concentration of the nanotubes or the polymerization condition. Regarding flexural strength, the addition of the nt-TiO2 in concentrations of either 0.3% (A03) or 0.9% (A09) resulted in data similar to those in the dual-curing control (DC) condition. The average modulus of elasticity increased with the addition of 0.9% nt-TiO2 (A09), and as with all the groups in the dual-curing condition, the addition of nt-TiO2 did not affect the results. The addition of either 0.6% (A06 and D06) or 0.9% (A09 and D09) of nt-TiO2 cement increased hardness values relative to the control groups (AC and DC). The group with a 0.3% concentration of nt-TiO2 (A03 and D03) showed higher bonding shear strength values than several of the groups with higher concentrations (A06, D06 and D09), but the A09 group had no difference relative to either control group (AC or DC). For cell viability in the 24-h period, the D03 D06 and D09 groups achieved a result similar to that of the CP group with significant difference to the DC group that had lower absorbance values. At the benchmarks of 48 and 72 h, and only the CN group showed a significant difference compared to others. The addition of nt-TiO2 is a promising strategy for improving the physical-chemical and mechanical properties without prejudice the biological properties.
|
5 |
Análise da resistência à fadiga entre pilares retos sólidos e anatômicos do sistema cone morseSantos, Vanessa Tavares de Gois 17 February 2014 (has links)
Fundação de Apoio a Pesquisa e à Inovação Tecnológica do Estado de Sergipe - FAPITEC/SE / Objective: Examine the fatigue resistance of the joint implant-abutment, in straight and anatomical types, submitted to cyclic loads. Material and methods: We used 37 implants (3.75 x 11mm) with morse taper system and 37 abutments, divided into two groups (n = 16: straight abutment, n=21 anatomical abutment, Neodent® Curitiba, Paraná, Brazil). The sets were submitted to cyclic testing using servo-hydraulic equipment, fixing the number of cycles at 5 million. Three sets implant-abutment of each group were subjected to bending tests to determine the maximum load resistance of the samples, which served as a parameter to measure the cyclic tests. We evaluated number of cycles, load and bending moment of the samples. The Fisher’s Test and simple independent test of Mann Whitney were applied. To characterize the survival timings of the test samples, the log-rank test was used. Results: Out of the 31 abutments cyclically tested, 17 (54.8%) fractured in a number of cycles below 5 million established, and 8 (25.8%) belonged to the group of the straight abutments and 9 (29%) of the anatomical abutments, 14 samples (45.2%) resisted the cyclic (5-straight abutments and 9-anatomical abutments). According to Fisher's Exact Test showed no statistical difference between groups (p = 0.394). In relation to the load (N) submitted during the cyclic test, the straight abutments showed larger fracture loads (mean: 566N±59N) that anatomical abutments (mean: 367N±80N). In addition, the minimum and maximum load values occurring in fractured samples of the straight group were higher compared to the anatomical. Regarding the average values of bending moment (Nmm), the Mann Whitney showed variations of the moment in both groups, and the fractured samples behaved slightly significant (p = 0.09). Conclusion: In cyclic fatigue tests, the solid straight abutments obtained average load and bending moment greater than the anatomical abutments. Considering fatigue strength of the fractured samples, there was a significant difference in the load variable and bending moment, with the straight abutment showing higher mean, moreover, for the varying cycles, the two types of abutments (straight and anatomical) behaved mechanically in a similar way. / Objetivo: Analisar a resistência à fadiga dos conjuntos implante/pilar, nos tipos reto e anatômico, submetidos a cargas cíclicas. Material e métodos: Foram utilizados 37 implantes (3.75 x 11mm) com sistema cone morse e 37 pilares, divididos em dois grupos (n=16: pilar reto, n=21: pilar anatômico, Neodent® Curitiba, Paraná, Brasil). Os conjuntos foram submetidos a testes de flexão e testes cíclicos, fixando-se o número de ciclos em 5 milhões, em equipamento servo-hidráulico. Três conjuntos implante/pilar de cada grupo foram submetidos a testes de flexão para determinação da carga máxima de resistência das amostras, que serviu como medida parâmetro para os ensaios cíclicos. Foram avaliados número de ciclos, carga e momento fletor das amostras. O Teste de Fisher e teste independente simples de Mann Whitney foram aplicados. Para caracterizar os tempos de sobrevivência das amostras em ensaio, foi utilizado o Teste Log-Rank. Resultados: Dos 31 pilares testados ciclicamente, 17 (54,8%) fraturaram em um número de ciclos abaixo dos 5 milhões estabelecidos, sendo que 8 (25,8%) pertenciam ao grupo dos pilares retos e 9 (29%) dos pilares anatômicos; 14 amostras (45,2%) resistiram aos testes cíclicos (5-pilares retos (16,1%) e 9-pilares anatômicos (29,1%). De acordo com o Teste Exato de Fisher não houve diferença estatística entre os grupos (p=0,394). Em relação à carga (N) submetida durante o ensaio cíclico, os pilares retos apresentaram cargas maiores de fratura (média: 566N±59N) que os pilares anatômicos (média: 367N±80N). Além disso, os valores mínimos e máximos de carga ocorridos nas amostras fraturadas do grupo reto foram maiores em relação aos anatômicos. Quanto aos valores médios de momento fletor (Nmm), o Teste de Mann Whitney constatou variações do momento nos dois grupos, as amostras fraturadas comportaram-se de maneira ligeiramente significante (p=0,09). Conclusão: Nos ensaios cíclicos de fadiga, os pilares retos sólidos obtiveram médias de carga e de momento fletor maiores que os pilares anatômicos. Considerando resistência à fadiga das amostras fraturadas, houve diferença significante nas variáveis carga e momento fletor, com o pilar reto mostrando maiores médias; além disso, quanto à variável ciclo, os dois tipos de pilares (retos e anatômicos) comportaram-se mecanicamente de maneira semelhante.
|
6 |
Caracterização físico-química, mecânica e biológica de cimento autoadesivo aditivado com nanotubos de dióxido de titânio / Physical-chemical, mechanical and biological characterization of reinforcement self-adhesive resin cement titanium dioxide nanotubesCarla Müller Ramos Tonello 28 November 2016 (has links)
O objetivo desse estudo foi realizar a caracterização do cimento resinoso autoadesivo RelyX U200 aditivado de nanotubos de dióxido de titânio (nt-TiO2) em diferentes concentrações (0,3, 0,6, e 0,9% em peso) quanto às suas propriedades físico-químicas, mecânicas e biológica. Duas condições de polimerização foram analisadas: autopolimerizável (grupos: AC, A03, A06 e A09) e dual (grupos: DC, D03, D06 e D09). Para análise do grau de conversão foi utilizada a espectroscopia de infravermelho com transformada de Fourier com registro do espectro nos tempos de 3, 6, 9, 12 e 15 minutos. Os picos das bandas de comprimento de onda de 1638 cm-1 e de 1608 cm-1 foram identificados para cálculo do grau de conversão. Os dados foram submetidos à ANOVA de medidas repetidas seguido de comparações múltiplas de Tukey (=0,05). A análise de sorção e solubilidade foi realizada por meio da confecção de discos de cimento resinoso (10 mm ø × 2 mm) (n=8) monitorados quanto à sua massa depois de ciclos de hidratação/desidratação. A resistência à flexão em 3 pontos e módulo de elasticidade foram mensurados por meio de barras (2 × 2 × 25 mm) de cimento resinoso (n=10) levadas à máquina universal de ensaios. Para análise de Dureza Knoop utilizou-se microdurômetro com carga de 50g /10 segundos. Nos discos de cimento resinoso de 10 mm ø × 2 mm foram realizadas 5 endentações equidistantes 0,5mm e medidas em aumento de 50×. Para resistência de união ao cisalhamento, sobre discos de zircônia sinterizados foi aplicado o cimento resinoso (n=10) nas dimensões de 3 mm ø × 2 mm. Por meio de dispositivo foram levados à máquina universal de ensaios. Os dados encontrados de sorção e solubilidade e de cada propriedade mecânica foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Exceto para resistência ao cisalhamento que se utilizou o teste de comparação de Fischer (=0,05). Para viabilidade celular (n=8) foi realizado teste de MTT apenas na condição dual. Os grupos estudados foram: DC, D03, D06, D09, CP (controle positivo), CN (controle negativo). Após 24, 48 e 72 horas os níveis de absorbâncias foram analisados por meio de espectrofotometria no leitor de ELISA. Os dados foram submetidos aos testes ANOVA a dois critérios e de comparações múltiplas de Tukey (=0,05). Os resultados mostraram que a adição de nt-TiO2, independente da concentração, aumentou os valores de grau de conversão do cimento resinoso para a condição autopolimerizável e dual em todos os tempos estudados. Já para sorção e solubilidade não houve influência nos resultados da concentração de nanotubos inseridos e da condição de polimerização. Para resistência flexural, a adição de nt-TiO2 nas concentrações de 0,3% (A03) e 0,9% (A09) resultou em dados similares ao controle na condição dual (DC). O valor médio de módulo de elasticidade aumentou com a adição de 0,9% (A09), similar a todos os grupos da condição dual, em que adição de nt-TiO2 não influenciou os resultados. A adição de 0,6% (A06 e D06) e 0,9% (A09 e D09) de nt-TiO2 ao cimento aumentou os valores de dureza quando comparado aos grupos controle (AC e DC). Para resistência de união ao cisalhamento, a concentração de 0,3% de nt-TiO2 (A03 e D03) aumentou os valores quando comparado aos grupos A06, D06, A09 e D09 porém sem diferença para os grupos controle (AC e DC). Para viabilidade celular no período de 24h, os grupos D03, D06 e D09 obtiveram resultado similar ao grupo CP, já o grupo DC apresentou valores de absorbância inferiores ao CP, usado como parâmetro de comparação. Em 48 e 72h, todos os grupos experimentais não demonstraram diferença significativa em comparação ao grupo CP. O grupo CN apresentou diferença para os demais em todos dos tempos estudados. A adição de nt-TiO2 ao cimento resinoso autoadesivo representa uma estratégia promissora para potencializar suas propriedades físico-químicas e mecânicas sem prejuízo das propriedades biológicas. / The aim of this study was to characterize the self-adhesive resin cement RelyX U200 additive, titanium dioxide nanotubes (nt-TiO2), at different concentrations (0.3%, 0.6%, and 0.9% by weight) and to determine their physicochemical, mechanical and biological properties. Two polymerization conditions were analyzed: self-curing (groups AC, A03, A06 and A09) and dual-curing (groups DC, D03, D06 and D09). To analyze the conversion degree, Fourier transform infrared spectroscopy was used, and the spectrum was recorded at 3, 6, 9, 12 and 15 minutes. The peaks of the wavelength bands, 1638 cm-1 and 1608 cm-1, were identified to calculate the degree of conversion. The data were subjected to a repeated-measures ANOVA followed by a Tukey multiple-comparison test (=0.05). The sorption and solubility analysis was performed by making resin-cement discs (10 mm ø × 2 mm) (n=8) and monitoring their masses after the hydration/dehydration cycles. The 3-point flexural strength and the modulus of elasticity of resin-cement bars (2 × 2 × 25 mm) (n=10) were measured using a universal testing machine. The Knoop microhardness was analyzed with a load of 50 g and a time of 10 seconds. On each resin cement disc, 5 equidistant indentations of 0.5 mm were made, and the measures were increased by 50×. To test bonding shear strength, resin cement was applied to sintered zirconia discs (3 mm ø × 2 mm) (n=10). The bonded discs were then taken to the universal testing machine. Their sorption, solubility and each mechanical property were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The shear strength was submitted to a Fischer comparison test (=0.05). To test cell viability (n=8), a MTT assay was performed using only the dual-curing condition. The studied groups were: DC, D03, D06, D09, CP (positive control) and CN (negative control). After 24, 48 and 72 hours, the absorbance levels were analyzed using an ELISA spectrophotometry reader. The data were submitted to a two-way ANOVA and a Tukey multiple-comparison test (=0.05). The results showed that the addition of nt-TiO2, regardless of concentration, increased the conversion degree values for the self-curing resin cement and for the dual-curing at all times studied. The sorption and solubility were not influenced by the concentration of the nanotubes or the polymerization condition. Regarding flexural strength, the addition of the nt-TiO2 in concentrations of either 0.3% (A03) or 0.9% (A09) resulted in data similar to those in the dual-curing control (DC) condition. The average modulus of elasticity increased with the addition of 0.9% nt-TiO2 (A09), and as with all the groups in the dual-curing condition, the addition of nt-TiO2 did not affect the results. The addition of either 0.6% (A06 and D06) or 0.9% (A09 and D09) of nt-TiO2 cement increased hardness values relative to the control groups (AC and DC). The group with a 0.3% concentration of nt-TiO2 (A03 and D03) showed higher bonding shear strength values than several of the groups with higher concentrations (A06, D06 and D09), but the A09 group had no difference relative to either control group (AC or DC). For cell viability in the 24-h period, the D03 D06 and D09 groups achieved a result similar to that of the CP group with significant difference to the DC group that had lower absorbance values. At the benchmarks of 48 and 72 h, and only the CN group showed a significant difference compared to others. The addition of nt-TiO2 is a promising strategy for improving the physical-chemical and mechanical properties without prejudice the biological properties.
|
7 |
Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014 / Load-deflection study of caliber 0.014 nickel-titanium orthodontic wiresSathler-Zanda, Renata 03 July 2012 (has links)
PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade, forças dentro de uma faixa considerada ótima e homogeneidade de amostra, foram os grupos Morelli termoativado e Ormco CuNiTi. / OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.
|
8 |
Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014 / Load-deflection study of caliber 0.014 nickel-titanium orthodontic wiresRenata Sathler-Zanda 03 July 2012 (has links)
PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade, forças dentro de uma faixa considerada ótima e homogeneidade de amostra, foram os grupos Morelli termoativado e Ormco CuNiTi. / OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.
|
Page generated in 0.0569 seconds