• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 17
  • 2
  • 1
  • Tagged with
  • 55
  • 43
  • 30
  • 30
  • 24
  • 17
  • 16
  • 15
  • 14
  • 11
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Análise comparativa do grau de rotação de parafusos para sistema UCLA em estruturas fundidas em monobloco provenientes de \'abutments\' calcináveis e com cinta de Colbato-Cromo / Comparative analysis of the rotational angle degree on UCLA burnout/Cobalt-Chromium machined collar abutment screws for one-piece cast metal frameworks

Luis Eduardo Butignon 21 May 2007 (has links)
Problemática: De ocorrência clínica bastante comum, o afrouxamento dos parafusos que compõe uma prótese sobre implante é uma complicação que traz transtornos tanto para o profissional quanto para o paciente. Proposição: O objetivo deste estudo foi comparar o grau de rotação de parafusos de titânio (grau 5), durante testes de torque, re-torque e os valores de destorque (Ncm), sobre infra-estruturas fundidas em monobloco, a partir de abutments tipo UCLA totalmente calcináveis e com cinta usinada em Co-Cr. Material e métodos: Um dispositivo leitor da quantidade de graus foi especialmente desenvolvido para este estudo, juntamente com um software . Dois implantes Revolution - SIN de 3,75 mm de diâmetro e 13 mm de comprimento e hexágono externo foram montados na base de um dispositivo e diretamente sobre eles foram obtidos os padrões para fundição dos corpos de prova. Cada corpo de prova foi formado por dois abutments tipo UCLA, totalmente calcináveis ou com cinta em Co-Cr, interligados por uma barra acrílica. Foram obtidos 10 corpos de prova para cada grupo e 40 parafusos de titânio (Grau 5) foram usados para os testes. Obteve-se então a medição do ângulo criado durante o aperto e re-aperto dos parafusos, sendo o re-aperto realizado após 10 minutos do aperto inicial, ambos sob torque de 30Ncm. Após o procedimento de re-aperto, o valor de destoque era imediatamente aferido e anotado em Ncm, possibilitando avaliar a quantidade de torque retido pelo parafuso após o procedimento, sendo esta seqüência realizada 3 vezes para cada corpo de prova. Análises em MEV foram realizadas nas bases de assentamento dos abutments antes e após a realização dos testes, assim como na superfície dos parafusos, a fim de se encontrar eventuais danos na microestrutura dos mesmos. O teste ?t? de student foi aplicado para uma avaliação entre os grupos e o teste ANOVA a um critério foi utilizado para análise intra-grupo. Resultados: Os resultados revelaram que durante os procedimentos de torque (aperto), os parafusos empregados em infra-estruturas obtidas a partir de abutments totalmente calcináveis apresentaram um maior grau de rotação (ensaio1: 61,664°; ensaio 2: 47,718°; ensaio 3: 47,374°), quando comparados aos parafusos empregados em infra-estruturas obtidas de abutments com cinta usinada em Co-Cr (ensaio 1: 49,038°; ensaio 2: 41,636°; ensaio 3: 43,273°), sendo a diferença entre os grupos estatisticamente significante em todos os ensaios realizados; P<0,05. Além disso, em ambos os grupos, a maior rotação dos parafusos ocorreu no primeiro aperto dos mesmos tanto durante o procedimento de torque quanto no procedimento de re-torque. Durante o re-torque, o ângulo formado na cabeça dos parafusos também foi sempre maior para o grupo Acrílico Calcinável (ensaio 1: 14,591°; ensaio 2: 12,987°; ensaio 3: 13,095°), comparado ao grupo Co-Cr (ensaio 1: 11,481°; ensaio 2: 10,117°; ensaio 3: 12,213°), sendo que diferença estatisticamente significante foi encontrada entre os ensaio 1 e 2; P<0,05. Os valores médios de destorque (quantidade de torque retido durante o aperto dos parafusos) também foram sempre maiores para o grupo Acrílico Calcinável (ensaio 1: 27,325Ncm; ensaio 2: 27,050Ncm; ensaio 3: 26,975Ncm), quando comparado ao grupo Co-Cr (ensaio 1: 26,250Ncm; ensaio 2: 26,975Ncm; ensaio 3: 26,400Ncm), porém sem diferença estatisticamente significante. As Imagens obtidas das análises em MEV demonstraram que as superfícies das bases de assentamentos do abutments obtidos a partir de abutments totalmente calcináveis apresentaram grandes irregularidades superficiais, comparadas às obtidas a partir de bases usinadas em Co-Cr, as quais apresentaram um padrão mais liso e uniforme. Quanto à análise dos parafusos, foi encontrado que as maiores deformações dos mesmos ocorrem na base de assentamento de sua cabeça no interior do abutments assim como na região da sua primeira rosca (apical). Conclusões: Tanto para o momento de torque quanto para o momento de re-torque, infra-estruturas do grupo Acrílico Calcinável permitiram maior rotação dos parafusos dos abutments, quando comparados com o grupo Co-Cr. Na análise dos valores de destorque, estatisticamente os grupos foram considerados semelhantes. Imagens em MEV, antes da realização dos testes de torque, re-torque e destorque revelaram que a base de assentamento do grupo Acrílico Calcinável apresentou aspecto mais irregular da fundição quando comparado ao grupo Co-Cr. Em ambos os grupos, partículas de titânio foram encontradas incrustadas nestas bases de assentamento após a realização desses testes, segundo dados do EDS. As imagem em MEV revelaram ainda que os parafusos se deformam principalmente na base de sua cabeça que se assenta no interior dos abutments, assim como na região da sua primeira rosca(apical). / Problem: The abutment screw loosening is a common drawback which concerns both patients and practitioners. Purpose: The aim of this study is to compare the rotational angle degree of Grade V titanium screws during torque, retorque and detorque steps (Ncm) on one-piece cast metal frameworks obtained from UCLA burnout/Co-Cr machined collar abutments. Material and methods: Two external hexagonal implants with 3.75mm in diameter and 13mm in length (Revolution, SIN) were secured to a metallic base and the wax patterns directly fabricated over them. The UCLA burnout/ Co-Cr machined collar abutments were screwed to the implants and joined together with an acrylic resin bar. Ten samples for each abutment type were fabricated. Forty Grade V titanium screws were used in the test. The rotation angle degree was measured with the aid of an specially constructed device and a computer software, during torque and retorque procedures, being the retorque made 10 minutes after the initial torque, both under 30Ncm. After the retorque procedures, the detorque values were measured. The overall sequence (torque, retorque, and detorque) was made three times for each sample. SEM analysis at the implant-abutment interfaces were made before and after the tests, as well as on the screw surfaces to detect possible microdamaging. The Student?s t test was used for between group analyses and the one-way ANOVA test for within group analyses. Results: The rotational angle degree was higher for screws used in the UCLA burnout (test 1: 61,664°; test 2: 47,718°; test 3: 47,374°) than in the Co-Cr machined collar abutments (test 1: 49,038°; test 2: 41,636°; test 3: 43,273°) (P<.05). The highest rotational degree values were observed on the first screwing during torque and retorque procedures. During retorque, the angle formed on the screw head was higher for the UCLA burnout (test 1: 14,591°; test 2: 12,987°; test 3: 13,095°) than the Co-Cr machined collar abutments (test 1: 11,481°; test 2: 10,117°; test 3: 12,213°), being these differences statistically significant between the first and second screwing (P<.05). The mean detorque values were higher in the UCLA burnout (test 1: 27,325Ncm; test 2: 27,050Ncm; test 3: 26,975Ncm) than in the Co-Cr machined collar screw abutments (test 1: 26,250Ncm; test 2: 26,975Ncm; test 3: 26,400Ncm), but not statistically significant. The SEM images demonstrated that the seating surface of the UCLA burnout abutments presented greater irregularities than the Co-Cr machined collar surfaces, which present a more smooth and flat pattern. Greater deformations were found at the seating abutment screw undersurfaces and in the first apical thread as well. Conclusions: The rotational degree was higher in the torque and retorque procedures for UCLA burnout than in the Co-Cr machined collar screw abutments. The detorque values were similar in both groups. The SEM images before torque, retorque and detorque procedures revealed more surface irregularities in the UCLA burnout abutments. In both groups, titanium debris were found in the seating abutment platforms after the tests by EDS images. The SEM images revealed that the abutment screws suffer deformation in the abutment head undersurface as well as in their first apical threads.
42

\"Estudo prospectivo dos parâmetros periodontais e peri-implantares dos pilares que recebem prótese dento-implanto-suportada\" / Prospective study of periodontal and peri-implant parameters of the pillars receiving an implant supported dental prosthesis

Lima, Vicente José Muratore de 18 September 2006 (has links)
Desde a introdução dos implantes na Odontologia, controvérsias tem havido acerca da propriedade de conectar os implantes a dentes em próteses fixas. Os implantes osseointegrados não apresentam nenhum ligamento periodontal e são mais firmemente ancorados ao osso. A diferença apresentada nesta ancoragem tem levantado preocupações acerca de o implante osseointegrado, por sua firme fixação ao osso, apresentar pouca flexibilidade para dividir as cargas funcionais com os dentes conectados. O presente estudo teve como propósito acompanhar prospectivamente os parâmetros periodontais ? índice gengival, índice de sangramento, profundidade de sondagem e perda de inserção entre o dente pilar de uma prótese dento-implanto-suportada com o dente colateral do mesmo paciente, e também os parâmetros peri-implantares dos implantes que suportam estas próteses - índice gengival; índice de sangramento; profundidade de sondagem e perda de inserção. Para verificar a perda de inserção foi utilizado o recurso da subtração radiográfica da região em que a prótese foi instalada, com tomadas radiográficas efetuadas no momento da instalação da prótese, decorridos seis meses e após 12 meses de uso, com o objetivo de verificar a ocorrência, ou não, de alteração do suporte ósseo peri-implantar. Foram selecionados 12 pacientes com estado de saúde normal, apresentando área posterior de mandíbula edêntula onde estava indicada a reabilitação protética por meio de prótese fixa unindo dente a implante. Estes foram tratados com implante de um estágio de 10 mm padrão da Straumann (ITI), que apresenta um pescoço polido de 2.8mm, onde a porção do implante que permanece intra-óssea apresenta uma superfície tratada, com diâmetro de 4.1mm. O implante foi instalado no espaço onde se localizaria o retentor mais distal da futura prótese parcial fixa, seguindo o protocolo. As radiografias digitais obtidas foram avaliadas num software de subtração radiográfica, Matrox Inspector versão oito, para verificar a alteração da variação de densidade óptica e contraste das radiografias quando superpostas, sendo os valores observados no implante comparados com os critérios de sucessos , amplamente abordados nos estudos verificados. Todos os implantes instalados nos pacientes osseointegraram, não houve registro de alteração óssea ao redor dos mesmos e nos dentes pilares das próteses em avaliações feitas após seis meses e 12 meses. As próteses continuaram clinicamente em excelente estado após 12 meses de avaliação nas análises clínicas e radiográficas. Ainda, de acordo com o teste de Sinais de Postos de ilcoxon, concluiu-se estatisticamente que não houve diferença nos parâmetros peri-implantares de cada paciente durante os períodos analisados (zero, seis meses e 12 meses), bem como quando comparados com os respectivos dentes colaterais. / Since the introduction of implants in Dentistry, controversies have arisen about the possibility of connecting implants to teeth in fixed prostheses. Osseointegrated implants do no present any periodontal ligature and are more firmly anchored to the bone. The difference presented by this type of anchorage has led to some concern about the limited flexibility of the osseointegrated implant to share the functional loads with the connected teeth. This study intended to follow-up prospectively the periodontal parameters bleeding index, probing depth between the pillar tooth of an implant supported prosthesis with one control tooth of the same patient and also the implants that support theses prostheses. That is why subtraction radiography of the region in which the prosthesis was placed was used, with radiographs taken at prosthesis placement, after six months and one year of use to verify if the periimplant osseous support had or had not undergone changes. Twelve patients with normal health conditions were selected who presented a posterior area edentulous jaw where a prosthetic rehabilitation by a fixed prosthesis joining tooth to implant was indicated. Patients were treated with an implant of one stage of 10mm standard Straumann (ITI) with a 2.8 mm polished neck, in which the remaining intraosseous portion of the implant has a treated surface of 4.1 mm diameter. The implant was placed in the space where according to the protocol, the more distal retainer of the future fixed partial prosthesis would be located. Digital radiographs were assessed with a subtraction radiography software Matrox Inspector version eight, to corroborate the change of contrast in the radiographs when superimposed, with values observed in the implant compared with the success criteria , widely mentioned in surveyed studies. All implants placed in patients became osseointegrated. There was no record of bone change around them and in the dental pillars of the prostheses at the one year follow-up. Prostheses continue to be in excellent conditions after the one year follow-up based upon clinical and radiographic analyses. Furthermore, in accordance with the Wilcoxon test of matched pairs and signed rank, it was concluded that there was no statistical difference between each group of each patient during the time period analyzed (baseline and one year) as well as when the pillars were compared to their respective controls.
43

"Biomecânica da transmissão de cargas a implantes unitários em função dos materiais protéticos: análise fotoelástica e dinâmica" / Biomechanics load transmission single implants according to prosthetic materials photoelastic and dinamic analysis

Markarian, Roberto Adrian 13 June 2005 (has links)
Em próteses sobre implantes, o recobrimento oclusal com materiais pouco rígidos como os acrílicos, é por vezes utilizado por supostamente reduzir a carga transmitida ao osso, entretanto não existe um consenso na literatura sobre a sua efetividade. O objetivo deste trabalho foi comparar, por análise fotoelástica e dinâmica, a transmissão de forças após a ação de cargas sobre próteses unitárias sobre implantes em função dos materiais protéticos. Confeccionou-se um modelo em resina fotoelástica com anatomia semelhante à região de pré-molares inferiores, contendo um implante de hexágono interno de 3,75 x 11,5 mm. Foram elaboradas três tipos de próteses em materiais com rigidez decrescente: 1- Metálica (alta rigidez); 2- Resina composta (rigidez moderada), 3- Com um disco de EVA interposto com h=2,5 mm (baixa rigidez). Por meio de um polariscópio circular, observou-se qualitativamente a tensão gerada no modelo durante a aplicação de forças axiais de 100 N, em regime compressivo, sobre cada tipo de prótese. Para a análise dinâmica, realizou-se um modelamento físico de cada um dos três sistemas implante-prótese com modelos de Voigt. A partir daí, uma representação matemática dos sistemas foi deduzida e resolvida, levando em consideração as propriedades mecânicas dos diferentes materiais testados, como o módulo de elasticidade (E), o coeficiente elástico (k) e a constante de amortecimento (c). Para representar uma carga mastigatória fisiológica, foi aplicado um pulso de força senoidal com duração de 0,25 s e intensidade máxima de 100 N, segundo a expressão ()) 8 cos( . 50 50 t t f &#960; &#8722;=. Observou-se na análise fotoelástica que após a aplicação de 100N, surgiram tensões na região apical e na cervical dos implantes, com intensidade e localização similares entre os três tipos de prótese. A análise dinâmica mostrou que a força de 100N aplicada na prótese é totalmente transmitida ao implante instantaneamente. Os resultados das análises concordam entre si e mostram que não é possível amortecer as forças mastigatórias por meio dos materiais oclusais. / Less rigid oclusal materials such as acrylic resins are often used in prosthesis over implants because they are supposed to diminish the loads transferred to the bone; however there is no scientific evidence to support this theory. The objective of this work was to compare by photoelastic and dynamic analysis the load transfer after oclusal loads over single prosthesis over implants, varying the oclusal materials. A photoelastic model was created, with an anatomy similar to an inferior premolar region. An internal hexagon implant (3,75 x 11,5 mm) was put in this model. Three different types of prosthesis were constructed with decrescent stiffness: 1- Metallic (higher stiffness); 2- Composite resin (moderate stiffness); 3- With an EVA disc interposed (fewer stiffness). By means of a circular polariscope, the stress generated in the model with a compressive axial load of 100 N, was observed for each prosthesis. For the dynamic analysis, a physical modeling of each implant-prosthesis was carried out with Voigt models. After that, a mathematical representation of the systems was deduced and solved, taking into account the mechanic properties of the different materials, like the elastic modulus (E), the elastic coefficient (k) and the damping constant (c). To represent a physiologic masticatory load, a senoidal force was applied, during 0,25 s and maximum load of 100 N, by the expression ()) 8 cos( . 50 50 t t f &#960; &#8722;=. With the photoelastic analysis, it was observed that stresses were generated at the apical and cervical regions of implants, with similar intensity and patterns between the three types of prosthesis. The dynamic analysis, showed that the loads applied over the prosthesis are transferred to the implant instantaneously. The results of both anaylis are in agreement that it is not possible to damp masticatory loads by means of occlusal materials.
44

Eficácia na remoção da necrose óssea térmica: realizada por implantes osseointegráveis com câmaras coletoras / Removal effectiveness of thermal osteonecrosis: performed by osseointegrated implants with collecting chambers

Barbosa, Bruno Aiello 28 June 2013 (has links)
Durante a confecção do alvéolo, promove-se o aumento da temperatura da broca devido à fricção, aquecendo o tecido ósseo adjacente e seus componentes celulares, podendo provocar a Necrose Óssea Térmica. A necrose óssea térmica deteriora a porção orgânica do tecido ósseo (tanto matriz óssea como as células), bem como as células diferenciadas e indiferenciadas presentes na circulação sanguínea e medula óssea local. Alguns trabalhos demonstraram que o aquecimento ósseo acima de 47oC por 1 minuto provoca tal fenômeno. Atualmente existem variações na técnica de perfuração com objetivo de diminuir o grau de aquecimento e aumentar as taxas de sucesso dos tratamentos reabilitadores. Sabemos que nem todos os profissionais são cautelosos em utilizar materiais de qualidade e que mesmo os materiais com qualidade, após repetido uso, perdem a eficácia. Seria ideal que o implante osseointegrável gerenciasse a remoção destas áreas de necrose óssea térmica, independentemente da execução correta da técnica de perfuração e da qualidade das brocas. Com isso, garantiríamos que o tecido ósseo poderia se reparar ao redor dos implantes da melhor maneira possível. Neste trabalho avaliamos a eficácia de 3 modelos de implante com câmaras coletoras funcionais diferentes, em tecido ósseo de minipig. O implante com câmara coletora interna demonstrou-se 37,22% mais eficaz que o implante com câmaras externas e 3 arestas cortantes, quando os alvéolos eram confeccionados sem irrigação e com brocas desgastadas. O implante com câmaras coletoras externas e 4 arestas também demonstrou-se eficaz, porém manteve 83,75% das células viáveis enquanto que no grupo com câmaras internas este resultado foi de 91,39%. / The manufacture of the alveolus can increase the temperature of the drill due to friction heating the adjacent bone tissue and its cellular components, this phenomenon is known by thermal osteonecrosis. The thermal osteonecrosis deteriorates the organic portion of bone (bone matrix and cells), as well as undifferentiated and differentiated cells circulating in the blood and bone marrow. Some studies have demonstrated that bone heating above 47oC for 1 minute causes this phenomenon. Currently there are variations in drilling technique aiming to reduce the heating degree and increase the success rates of rehabilitation treatments. We know that not all professionals are cautious of using quality materials and even the materials with quality after repeated use, lose their effectiveness. Would be ideal that implants manages and removes these areas with thermal osteonecrosis, regardless of the technique of implementing the drilling and the quality of drills. With this, we ensure that bone tissue could possibly repair around implants in the best way. In this study we evaluated the efficacy of 3 implant models with different functional collecting chambers in minipigs bone tissue. The implant with internal collection chamber proved to be 37.22% more effective than the implant with external chambers and three sharp edges, when the alveolus were manufactured without irrigation and uncut drills. The implant with external collecting chambers and four sharp edges also showed an effective but 83.75% of the cells remained viable while in the group with internal chambers this result was 91.39%.
45

Avaliação in vitro pelo método DNA-Checkerboard da eficácia de uma pasta antimicrobiana e da adição de sais de prata em pilares protéticos, no controle da contaminação bacteriana através da interface implante-conector / In vitro evaluation by DNA checkerboard method of the efficacy of an antimicrobial paste and addition of silver salts in prosthetic abutments for the control of bacterial contamination at the implant-connector interface

Fernandes, Flávio Henrique Carriço Nogueira 14 November 2012 (has links)
A odontologia reabilitadora moderna preconiza cada vez mais o uso de implantes dentais para a substituição de dentes ausentes. É sabido que micro-organismos presentes na cavidade oral, em especial os relacionados à doença periodontal, são responsáveis pelos maiores índices de insucesso dos implantes. Este trabalho estudou a ocorrência de infiltração bacteriana através da interface implante-conector protético de implantes Cone Morse (CM) e Hexágono Interno (HI) após a associação com uma pasta antimicrobiana ou a adição de sais de prata nos pilares. Foram utilizados 72 implantes odontológicos de titânio (PROSS® - Sistema de Implantes, Dabi-Atlante, Ribeirão Preto, Brasil), 36 com conexão do tipo hexágono interno e 36 com conexão do tipo cone-morse, divididos em grupos, da seguinte forma: Grupo Pasta Antimicrobiana- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos, Grupo Íons de Prata- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos e Grupo Controle- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos. Os implantes e os conectores protéticos foram retirados de suas embalagens para aplicação do torque final (20N/cm). Antes disso, em um dos grupos experimentais, uma camada da pasta antimicrobiana foi aplicada sobre a superfície interna dos implantes e conectores protéticos e seus respectivos parafusos. Os conjuntos implantes-conectores foram parcialmente imersos na solução de saliva humana em tubos de ensaio e incubados em estufa bacteriológica a 37°C durante 7 dias. Após esse período, amostras do conteúdo interno dos conjuntos implantes-conectores protéticos dos 3 grupos foram colhidas com o objetivo de detectar e quantificar os micro-organismos presentes, utilizando para isto, a técnica de hibridização com sondas de DNA genômico DNA Checkerboard. Os implantes de conexão do tipo cone morse apresentaram menores valores de contagem de bactérias quando comparados aos implantes hexágono interno no grupo Controle (p<0,001), já para o grupo Íons de prata e Pasta antimicrobiana, foi observado comportamento inverso, maiores valores de contagem de bactérias para os implantes Cone Morse. Comparando-se os implantes de mesma conexão, entre os 03 grupos examinados, as amostras dos implantes Cone Morse dos grupos Controle, Íons de prata e Pasta antimicrobiana apresentaram valor de contagens de micro-organismos em ordem crescente. Os implantes de conexão hexágonal interna dos grupos Controle apresentaram maiores valores de contagens de micro-organismos seguidos pelos implantes do grupo Pasta antimicrobiana e Íons de prata, respectivamente. A partir dos resultados obtidos pode-se concluir que houve a passagem dos 43 micro-organismos analisados in vitro através da interface implante/componente protético em ambos os sistemas avaliados. Para ambos os tratamentos (adição de sais de prata às paredes dos pilares protéticos e aplicação da pasta antimicrobiana no interior dos implantes) houve diminução da infiltração microbiana no interior daqueles sistemas de conexão do tipo Hexágono Interno. / The contemporary and modern dentistry has been preconized the use of dental implants for replacement of missing teeth. The micro-organisms presents in oral environment, particularly those related to periodontal disease, are responsible for the highest failure rates of dental implants. This study evaluated the occurrence of bacterial leakage through the abutmentimplant interface in Morse Taped (CM) and Hexagon Internal (HI) dental implants after the association with antimicrobial paste or addition of silver salts on the abutments. 72 titanium dental implants (Pross ® - Implant System, Dabi-Atlante, Ribeirão Preto, Brazil), 36 with internal hexagon connection type and 36 with cone-morse connection type, divided into groups as follows: group Antimicrobial Paste -12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors, group Ion Silver-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors and Control Group-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors. The implants and prosthetic connectors have been removed from their packaging for applying of final torque (20N/cm). Previously, in one experimental group, a layer of antimicrobial paste was applied on the inner surface of implants and prosthetic connectors. The sets connector/implants were partially immersed in human saliva solution in test tubes and incubated in bacteriological oven at 37°C for 7 days. Subsequently, samples of the contents of internal prosthetic sets implantconnectors of the 3 groups were collected to detect and quantify micro-organisms, through the DNA Checkerboard Hybridization Technique. The morse taper implants had significantly lower bacterial count compared to internal hexagon implants in the control group (p <0.001), while for the group of Silver Ion and antimicrobial Paste, we observed an inverse behavior, higher counts of micro-organisms for Morse taper implants. Comparing the same connection implants, among the 03 groups examined, samples of implants Morse Taper Control groups, Antimicrobial Paste and Silver ions exhibited values of counts of micro-organisms in ascending order. The internal hexagon implants of the Control group showed higher counts of microorganisms followed by Antimicrobial Paste and Silver Ions groups, respectively. The 43 species analyzed in vitro infiltrated through the interface implant / abutment in both systems evaluated; For both the treatments (adding silver salts in the abutments walls and applying of the antimicrobial paste within the implants) there was decreased microbial leakage through the interface connection for the internal hexagon dental implants
46

Análise microscópica da necrose óssea provocada pelo aquecimento friccional durante a confecção de alvéolos cirúrgicos para implantes osseointegráveis / Microscopic analysis of osteonecrosis caused by friccional heating during confection of surgical alveolus for osseointegrated implants

Barbosa, Bruno Aiello 23 April 2009 (has links)
A utilização de implantes osseointegráveis como substituto dentário tornou-se amplamente adotada desde a instalação e relato de sucesso dos primeiros implantes em seres humanos. A cirurgia para instalação de implantes osseointegráveis pode ser realizada em dois estágios, aguardando-se o período de osseointegração para confecção da prótese de transição ou definitiva; ou por estágio único, conhecida como carga imediata ou função imediata. Ambas as técnicas necessitam da confecção de um alvéolo cirúrgico, para isto utiliza-se de brocas em aço inoxidável. Durante a perfuração do alvéolo promove-se o aumento da temperatura da broca devido à fricção, aquecendo o tecido ósseo adjacente e podendo provocar a Necrose Óssea Térmica. A queima pode acometer uma pequena parte cortical ou comprometer todo alvéolo cirúrgico. A proposição deste trabalho foi analisar microscopicamente a existência ou não da necrose óssea térmica provocada por brocas durante a confecção de alvéolos cirúrgicos para implantes osseointegráveis quanto: à comparação entre broca nova e broca com desgaste; a interferência da irrigação externa. Além disso, propõe-se demonstrar por achados microscópicos o comportamento tecidual e celular frente a essas variantes. Para o estudo foram utilizados cinco pedaços de costela bovina removidas um dia após a morte do animal. Para o estudo as variantes foram: brocas novas, brocas velhas, presença ou não de irrigação externa. Os corpos de prova foram divididos em 4 grupos (N=5), combinando-se todas as possibilidades de variância. Após as perfurações, seguindo-se o protocolo de dilatação progressiva (BRÅNEMARK, 1980), confeccionaram-se lâminas histológicas para análise em microscopia óptica de luz. Com a contagem das células (osteócitos normais e osteócitos com núcleo picnótico) e das lacunas (osteoplastos), quantificou-se a viabilidade óssea de acordo com a necrose óssea térmica provocada durante o aquecimento friccional. Após análise estatística (p&#8804;0,05), verificou-se que as perfurações realizadas utilizando-se de irrigação externa 58,46% dos osteócitos apresentavam-se normais (viáveis), 30,15%, com lacunas vazias e 11,38% com os núcleos picnóticos. Já as perfurações confeccionadas por brocas desgastadas resultaram em 35,93% dos osteócitos normais, 16,18% com núcleos picnóticos e 47,89% de lacunas vazias. Correlacionando as variantes broca e irrigação, verifica-se a predominância de osteócitos normais como sinal de viabilidade óssea nos grupos: com irrigação e broca nova (66,10%) e com irrigação e brocas desgastadas (50,82%). Nos grupos onde os alvéolos foram realizados com brocas novas sem irrigação e de brocas desgastadas sem irrigação, observa-se a inviabilidade óssea pela predominância de osteócitos com núcleo picnótico e lacunas vazias, demonstrando a degeneração celular provocada pelo calor. Após o estudo, concluímos que a irrigação externa e a qualidade do corte das brocas são fundamentais e influenciam na manutenção da viabilidade óssea. Além disso, microscopicamente as células ósseas demonstram alterações morfológicas após o aquecimento friccional. / The use of osseointegrated implants as dental substitute became widely adopted since the installation of the first implant in human beings. The surgery for installation of osseointegrated implants can be carried through in two stages, waiting the period for osseointegration to do the definitive prosthesis or; in one stage, known as immediate loading or immediate function. Both the techniques need the confection of a surgical alveolus, for this are used stainless steel drills. During the alveolus perforation the friction increases the drill temperature which promotes the heating on adjacent bone tissue favoring the thermal osteonecrosis. The heating can commit a small cortical part or compromise all surgical alveolus. The aim of this study was to evaluate by microscopic analysis the existence of the thermal osteonecrosis or not, comparing new and old drills and, the interference of the external irrigation. For the present investigation five pieces (N=5) of bovine ribs had been removed one day after the death of the animal. The ribs were divided in 4 groups agreeing all the variance possibilities. After the perforations, following the protocol of gradual dilatation, we confectioned histological blades for analysis by light microscopy. We quantified the osseous viability by counting of the normal osteocytes, osteocytes with pyknotic nuclei and the empty lacunae. After statistical analysis (p&#8804;0.05), we verified that the perforations done using external irrigation 58.46% of the osteocytes were presented normal (viable), 30.15% with empty lacunae and 11.38% with pyknotic nuclei. Moreover, the perforations confectioned with old drills had resulted in 35.93% of normal osteocytes, 16.18% of pyknotic nuclei and 47.89% of empty lacunae. Correlating the variants, drill and irrigation, we verified the predominance of normal osteocytes, as a signal of osseous viability, in the groups with irrigation/new drills (66.10%) and with irrigation/old drills (50.82%). In the groups, where the alveolus had been carried through with new drills without irrigation and old drills without irrigation, it was observed osseous unavailability due to the predominance of osteocytes with pyknotic nucleus and empty lacunae. Those facts demonstrate the cellular degeneration caused by the heat. In this research, we conclude that the external irrigation and the drills cutting power influence in maintenance of the osseous viability. Furthermore, microscopically the bone cells demonstrate morphologic alterations after the frictional heating.
47

Análise microscópica da necrose óssea provocada pelo aquecimento friccional durante a confecção de alvéolos cirúrgicos para implantes osseointegráveis / Microscopic analysis of osteonecrosis caused by friccional heating during confection of surgical alveolus for osseointegrated implants

Bruno Aiello Barbosa 23 April 2009 (has links)
A utilização de implantes osseointegráveis como substituto dentário tornou-se amplamente adotada desde a instalação e relato de sucesso dos primeiros implantes em seres humanos. A cirurgia para instalação de implantes osseointegráveis pode ser realizada em dois estágios, aguardando-se o período de osseointegração para confecção da prótese de transição ou definitiva; ou por estágio único, conhecida como carga imediata ou função imediata. Ambas as técnicas necessitam da confecção de um alvéolo cirúrgico, para isto utiliza-se de brocas em aço inoxidável. Durante a perfuração do alvéolo promove-se o aumento da temperatura da broca devido à fricção, aquecendo o tecido ósseo adjacente e podendo provocar a Necrose Óssea Térmica. A queima pode acometer uma pequena parte cortical ou comprometer todo alvéolo cirúrgico. A proposição deste trabalho foi analisar microscopicamente a existência ou não da necrose óssea térmica provocada por brocas durante a confecção de alvéolos cirúrgicos para implantes osseointegráveis quanto: à comparação entre broca nova e broca com desgaste; a interferência da irrigação externa. Além disso, propõe-se demonstrar por achados microscópicos o comportamento tecidual e celular frente a essas variantes. Para o estudo foram utilizados cinco pedaços de costela bovina removidas um dia após a morte do animal. Para o estudo as variantes foram: brocas novas, brocas velhas, presença ou não de irrigação externa. Os corpos de prova foram divididos em 4 grupos (N=5), combinando-se todas as possibilidades de variância. Após as perfurações, seguindo-se o protocolo de dilatação progressiva (BRÅNEMARK, 1980), confeccionaram-se lâminas histológicas para análise em microscopia óptica de luz. Com a contagem das células (osteócitos normais e osteócitos com núcleo picnótico) e das lacunas (osteoplastos), quantificou-se a viabilidade óssea de acordo com a necrose óssea térmica provocada durante o aquecimento friccional. Após análise estatística (p&#8804;0,05), verificou-se que as perfurações realizadas utilizando-se de irrigação externa 58,46% dos osteócitos apresentavam-se normais (viáveis), 30,15%, com lacunas vazias e 11,38% com os núcleos picnóticos. Já as perfurações confeccionadas por brocas desgastadas resultaram em 35,93% dos osteócitos normais, 16,18% com núcleos picnóticos e 47,89% de lacunas vazias. Correlacionando as variantes broca e irrigação, verifica-se a predominância de osteócitos normais como sinal de viabilidade óssea nos grupos: com irrigação e broca nova (66,10%) e com irrigação e brocas desgastadas (50,82%). Nos grupos onde os alvéolos foram realizados com brocas novas sem irrigação e de brocas desgastadas sem irrigação, observa-se a inviabilidade óssea pela predominância de osteócitos com núcleo picnótico e lacunas vazias, demonstrando a degeneração celular provocada pelo calor. Após o estudo, concluímos que a irrigação externa e a qualidade do corte das brocas são fundamentais e influenciam na manutenção da viabilidade óssea. Além disso, microscopicamente as células ósseas demonstram alterações morfológicas após o aquecimento friccional. / The use of osseointegrated implants as dental substitute became widely adopted since the installation of the first implant in human beings. The surgery for installation of osseointegrated implants can be carried through in two stages, waiting the period for osseointegration to do the definitive prosthesis or; in one stage, known as immediate loading or immediate function. Both the techniques need the confection of a surgical alveolus, for this are used stainless steel drills. During the alveolus perforation the friction increases the drill temperature which promotes the heating on adjacent bone tissue favoring the thermal osteonecrosis. The heating can commit a small cortical part or compromise all surgical alveolus. The aim of this study was to evaluate by microscopic analysis the existence of the thermal osteonecrosis or not, comparing new and old drills and, the interference of the external irrigation. For the present investigation five pieces (N=5) of bovine ribs had been removed one day after the death of the animal. The ribs were divided in 4 groups agreeing all the variance possibilities. After the perforations, following the protocol of gradual dilatation, we confectioned histological blades for analysis by light microscopy. We quantified the osseous viability by counting of the normal osteocytes, osteocytes with pyknotic nuclei and the empty lacunae. After statistical analysis (p&#8804;0.05), we verified that the perforations done using external irrigation 58.46% of the osteocytes were presented normal (viable), 30.15% with empty lacunae and 11.38% with pyknotic nuclei. Moreover, the perforations confectioned with old drills had resulted in 35.93% of normal osteocytes, 16.18% of pyknotic nuclei and 47.89% of empty lacunae. Correlating the variants, drill and irrigation, we verified the predominance of normal osteocytes, as a signal of osseous viability, in the groups with irrigation/new drills (66.10%) and with irrigation/old drills (50.82%). In the groups, where the alveolus had been carried through with new drills without irrigation and old drills without irrigation, it was observed osseous unavailability due to the predominance of osteocytes with pyknotic nucleus and empty lacunae. Those facts demonstrate the cellular degeneration caused by the heat. In this research, we conclude that the external irrigation and the drills cutting power influence in maintenance of the osseous viability. Furthermore, microscopically the bone cells demonstrate morphologic alterations after the frictional heating.
48

Eficácia na remoção da necrose óssea térmica: realizada por implantes osseointegráveis com câmaras coletoras / Removal effectiveness of thermal osteonecrosis: performed by osseointegrated implants with collecting chambers

Bruno Aiello Barbosa 28 June 2013 (has links)
Durante a confecção do alvéolo, promove-se o aumento da temperatura da broca devido à fricção, aquecendo o tecido ósseo adjacente e seus componentes celulares, podendo provocar a Necrose Óssea Térmica. A necrose óssea térmica deteriora a porção orgânica do tecido ósseo (tanto matriz óssea como as células), bem como as células diferenciadas e indiferenciadas presentes na circulação sanguínea e medula óssea local. Alguns trabalhos demonstraram que o aquecimento ósseo acima de 47oC por 1 minuto provoca tal fenômeno. Atualmente existem variações na técnica de perfuração com objetivo de diminuir o grau de aquecimento e aumentar as taxas de sucesso dos tratamentos reabilitadores. Sabemos que nem todos os profissionais são cautelosos em utilizar materiais de qualidade e que mesmo os materiais com qualidade, após repetido uso, perdem a eficácia. Seria ideal que o implante osseointegrável gerenciasse a remoção destas áreas de necrose óssea térmica, independentemente da execução correta da técnica de perfuração e da qualidade das brocas. Com isso, garantiríamos que o tecido ósseo poderia se reparar ao redor dos implantes da melhor maneira possível. Neste trabalho avaliamos a eficácia de 3 modelos de implante com câmaras coletoras funcionais diferentes, em tecido ósseo de minipig. O implante com câmara coletora interna demonstrou-se 37,22% mais eficaz que o implante com câmaras externas e 3 arestas cortantes, quando os alvéolos eram confeccionados sem irrigação e com brocas desgastadas. O implante com câmaras coletoras externas e 4 arestas também demonstrou-se eficaz, porém manteve 83,75% das células viáveis enquanto que no grupo com câmaras internas este resultado foi de 91,39%. / The manufacture of the alveolus can increase the temperature of the drill due to friction heating the adjacent bone tissue and its cellular components, this phenomenon is known by thermal osteonecrosis. The thermal osteonecrosis deteriorates the organic portion of bone (bone matrix and cells), as well as undifferentiated and differentiated cells circulating in the blood and bone marrow. Some studies have demonstrated that bone heating above 47oC for 1 minute causes this phenomenon. Currently there are variations in drilling technique aiming to reduce the heating degree and increase the success rates of rehabilitation treatments. We know that not all professionals are cautious of using quality materials and even the materials with quality after repeated use, lose their effectiveness. Would be ideal that implants manages and removes these areas with thermal osteonecrosis, regardless of the technique of implementing the drilling and the quality of drills. With this, we ensure that bone tissue could possibly repair around implants in the best way. In this study we evaluated the efficacy of 3 implant models with different functional collecting chambers in minipigs bone tissue. The implant with internal collection chamber proved to be 37.22% more effective than the implant with external chambers and three sharp edges, when the alveolus were manufactured without irrigation and uncut drills. The implant with external collecting chambers and four sharp edges also showed an effective but 83.75% of the cells remained viable while in the group with internal chambers this result was 91.39%.
49

Avaliação in vitro pelo método DNA-Checkerboard da eficácia de uma pasta antimicrobiana e da adição de sais de prata em pilares protéticos, no controle da contaminação bacteriana através da interface implante-conector / In vitro evaluation by DNA checkerboard method of the efficacy of an antimicrobial paste and addition of silver salts in prosthetic abutments for the control of bacterial contamination at the implant-connector interface

Flávio Henrique Carriço Nogueira Fernandes 14 November 2012 (has links)
A odontologia reabilitadora moderna preconiza cada vez mais o uso de implantes dentais para a substituição de dentes ausentes. É sabido que micro-organismos presentes na cavidade oral, em especial os relacionados à doença periodontal, são responsáveis pelos maiores índices de insucesso dos implantes. Este trabalho estudou a ocorrência de infiltração bacteriana através da interface implante-conector protético de implantes Cone Morse (CM) e Hexágono Interno (HI) após a associação com uma pasta antimicrobiana ou a adição de sais de prata nos pilares. Foram utilizados 72 implantes odontológicos de titânio (PROSS® - Sistema de Implantes, Dabi-Atlante, Ribeirão Preto, Brasil), 36 com conexão do tipo hexágono interno e 36 com conexão do tipo cone-morse, divididos em grupos, da seguinte forma: Grupo Pasta Antimicrobiana- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos, Grupo Íons de Prata- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos e Grupo Controle- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos. Os implantes e os conectores protéticos foram retirados de suas embalagens para aplicação do torque final (20N/cm). Antes disso, em um dos grupos experimentais, uma camada da pasta antimicrobiana foi aplicada sobre a superfície interna dos implantes e conectores protéticos e seus respectivos parafusos. Os conjuntos implantes-conectores foram parcialmente imersos na solução de saliva humana em tubos de ensaio e incubados em estufa bacteriológica a 37°C durante 7 dias. Após esse período, amostras do conteúdo interno dos conjuntos implantes-conectores protéticos dos 3 grupos foram colhidas com o objetivo de detectar e quantificar os micro-organismos presentes, utilizando para isto, a técnica de hibridização com sondas de DNA genômico DNA Checkerboard. Os implantes de conexão do tipo cone morse apresentaram menores valores de contagem de bactérias quando comparados aos implantes hexágono interno no grupo Controle (p<0,001), já para o grupo Íons de prata e Pasta antimicrobiana, foi observado comportamento inverso, maiores valores de contagem de bactérias para os implantes Cone Morse. Comparando-se os implantes de mesma conexão, entre os 03 grupos examinados, as amostras dos implantes Cone Morse dos grupos Controle, Íons de prata e Pasta antimicrobiana apresentaram valor de contagens de micro-organismos em ordem crescente. Os implantes de conexão hexágonal interna dos grupos Controle apresentaram maiores valores de contagens de micro-organismos seguidos pelos implantes do grupo Pasta antimicrobiana e Íons de prata, respectivamente. A partir dos resultados obtidos pode-se concluir que houve a passagem dos 43 micro-organismos analisados in vitro através da interface implante/componente protético em ambos os sistemas avaliados. Para ambos os tratamentos (adição de sais de prata às paredes dos pilares protéticos e aplicação da pasta antimicrobiana no interior dos implantes) houve diminução da infiltração microbiana no interior daqueles sistemas de conexão do tipo Hexágono Interno. / The contemporary and modern dentistry has been preconized the use of dental implants for replacement of missing teeth. The micro-organisms presents in oral environment, particularly those related to periodontal disease, are responsible for the highest failure rates of dental implants. This study evaluated the occurrence of bacterial leakage through the abutmentimplant interface in Morse Taped (CM) and Hexagon Internal (HI) dental implants after the association with antimicrobial paste or addition of silver salts on the abutments. 72 titanium dental implants (Pross ® - Implant System, Dabi-Atlante, Ribeirão Preto, Brazil), 36 with internal hexagon connection type and 36 with cone-morse connection type, divided into groups as follows: group Antimicrobial Paste -12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors, group Ion Silver-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors and Control Group-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors. The implants and prosthetic connectors have been removed from their packaging for applying of final torque (20N/cm). Previously, in one experimental group, a layer of antimicrobial paste was applied on the inner surface of implants and prosthetic connectors. The sets connector/implants were partially immersed in human saliva solution in test tubes and incubated in bacteriological oven at 37°C for 7 days. Subsequently, samples of the contents of internal prosthetic sets implantconnectors of the 3 groups were collected to detect and quantify micro-organisms, through the DNA Checkerboard Hybridization Technique. The morse taper implants had significantly lower bacterial count compared to internal hexagon implants in the control group (p <0.001), while for the group of Silver Ion and antimicrobial Paste, we observed an inverse behavior, higher counts of micro-organisms for Morse taper implants. Comparing the same connection implants, among the 03 groups examined, samples of implants Morse Taper Control groups, Antimicrobial Paste and Silver ions exhibited values of counts of micro-organisms in ascending order. The internal hexagon implants of the Control group showed higher counts of microorganisms followed by Antimicrobial Paste and Silver Ions groups, respectively. The 43 species analyzed in vitro infiltrated through the interface implant / abutment in both systems evaluated; For both the treatments (adding silver salts in the abutments walls and applying of the antimicrobial paste within the implants) there was decreased microbial leakage through the interface connection for the internal hexagon dental implants
50

Analise fotoelastica da distribuição de tensões em dois sistemas de proteses mandibulares sobre implantes : barra distal e solda a laser / Photoelastic analysis of the distribution of the tensions in two systems of mandibular prosthesis over implants : distal bar and laser welding

Salles, Angelo Emilio Barroso de 12 August 2018 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T16:14:35Z (GMT). No. of bitstreams: 1 Salles_AngeloEmilioBarrosode_M.pdf: 10746117 bytes, checksum: 7a6d08147fb33c8d235cc7df5f8be032 (MD5) Previous issue date: 2008 / Resumo: Este estudo avaliou por meio de análise fotoelástica, a distribuição in vitro das tensões geradas na interface "osso/implante" em próteses mandibulares, tipo protocolo, comparando duas técnicas de confecção: Solda a laser e Barra Distal (Neodent, Curitiba - PR) onde não se utiliza infra-estrutura metálica. Foram confeccionadas duas próteses com design similares (uma para cada técnica), sobre uma matriz metálica simulando um arco mandibular edêntulo, onde foram instaladas cinco réplicas de implantes de corpo único (GT- Neodent, Curitiba - PR). A partir de um molde de silicone de duplicação (Silibor - Clássico Artigos Odontológicos Ltda.) foi confeccionado um modelo em resina fotoelástica (Araldite GY279BR - Araltec Produtos Químicos Ltda. Guarulhos - SP) com cinco implantes GT (Neodent, Curitiba - PR) incorporados. Após a instalação de cada prótese sobre o modelo fotoelástico, utilizando 10 N/cm para aperto dos parafusos, foi realizada análise fotoelástica. Em seguida, foi aplicada carga oclusal de 100 N em toda extensão de cada prótese, com auxílio de uma placa metálica posicionada sobre a face oclusal dos dentes, e então realizada nova análise das tensões. Estas análises foram executadas com o auxílio de um polariscópio circular acoplado a uma máquina fotográfica digital (H1 - Sony, Japão), que permitiu a visualização das franjas e registrou através de fotografias digitais o comportamento das mesmas ao redor dos implantes no modelo fotoelástico. De acordo com os resultados, concluiu-se que a técnica utilizando Barra Distal distribuiu melhor, e transmitiu com menos intensidade, após o aperto dos parafusos, as tensões geradas na interface "osso/implantes" do que a técnica utilizando solda a laser. No entanto, ocorreu o inverso após o carregamento oclusal. / Abstract: The aim of this study was to evaluate through photoelastic analysis, the in vitro distribution of the generated tensions in the "bone/ implant" interface in mandibular prostheses, protocol type, comparing two different working techniques: the idealized by Branemark and Distal Bar (Neodent, Curitiba - PR) where framework is not used. Two similar prostheses were made (one for each technique), on a metal matrix simulating an edentulous mandible, where five replications of single body implant were installed (GT-Neodent, Curitiba - PR). From a silicone mold for duplication (Silibor - Classico Artigos Odontológicos Ltda.), a model in photoelastic resin was created (Araldite GY279BR - Araltec Produtos Quimicos Ltda., Guarulhos - SP) with five GT implants (Neodent, Curitiba - PR) embedded. After the installation of each prosthesis on the photoelastic model, using 10 N/cm for tightening the screws, a photoelastic analysis was performed. Then a 100 N occlusion load was applied throughout each prosthesis extension with the help of a metal plate positioned on the occlusal face of the teeth, and then a new analysis of the tensions was conducted. These analyses were performed with the help of a circular polariscope attached to a digital camera (H1 - Sony, Japan), which allowed the visualization of the fringes and recorded by digital photos the behaviour of the implants. According to the results, it was concluded that the Distal Bar technique distributed better, and transmitted with less intensity, after the tightening of the screws, the generated tensions to the system "bone/implants" than the laser welding. However, it happened the opposite after the occlusal load. / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.1176 seconds