• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 17
  • 2
  • 1
  • Tagged with
  • 55
  • 43
  • 30
  • 30
  • 24
  • 17
  • 16
  • 15
  • 14
  • 11
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Influência de implantes pós-exodônticos com diferentes configurações sobre os tecidos peri-implantares: estudo experimental em cães

Caneva, Marco [UNESP] 05 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-05Bitstream added on 2014-06-13T21:04:26Z : No. of bitstreams: 1 caneva_m_dr_araca.pdf: 5420643 bytes, checksum: 2a88c9a9a85203bfd0cd8f4fd62affa4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: avaliar a influência da instalação de implantes em alvéolos imediatamente após a extração do elemento dental na regeneração dos tecidos peri-implantares com implantes de diferentes configurações Material e métodos: Nos alvéolos distais dos quartos pré-molares mandibulares de cães, imediatamente após as extrações das raízes dentais, foram instalados implantes cilíndricos com 3,3 mm de diâmetro (grupo controle) e implantes cônicos com 5,0 mm de diâmetro (grupo teste). Foram avaliados histologicamente a regeneração dos tecidos duros e moles peri-implantares após 4 meses do procedimento cirúrgico. Resultados: Todos os implantes apresentaram-se osseointegrados ao tecido ósseo maduro mineralizado. A crista óssea alveolar sofreu reabsorção tanto no grupo teste como controle. A superfície óssea vestibular dos implantes do grupo teste (cônico; 3,6 mm) apresentou maior grau de reabsorção em comparação ao grupo controle (cilíndrico; 1,6 mm). As dimensões dos tecidos moles apresentaram-se semelhantes em ambos os grupos. No entanto, em relação ao ombro do implante, a mucosa peri-implantar localizou-se mais apicalmente no grupo teste em relação ao grupo controle. Conclusão: Este estudo confirmou que a distância entre a superfície do implante e o contorno externo da crista óssea alveolar vestibular influenciou no grau de reabsorção da tábua óssea vestibular. Conseqüentemente, em relação ao ombro do implante, a mucosa peri-implantar será estabelecida em um nível mais apical, se a distância entre a superfície do implante e o contorno externo da crista óssea alveolar for menor / Aim: the aim of the present experiment was to study the influence of implant installation into sockets immediately after tooth extraction on the healing periimplant tissues with implants of various configurations. Material & methods: Transmucosal cylindrical 3.3mm in diameter implants in the control sites, and conical 5.0mm in diameter in the test sites, were installed into the distal socket of the forth mandibular premolars in dogs immediately after tooth extraction. After 4 months, the hard and soft tissue healing was evaluated histologically. Results: All implants were integrated in mineralized mature bone. Both at the test and control sites, the alveolar crest underwent resorption. The buccal bony surface at the implant of the test sites (conical; 3.6mm) was more resorbed compared to the control sites (cylindrical; 1.6mm). The soft tissue dimensions were similar in both groups. However, in relation to the implant shoulder, the periimplant mucosa was located more apically at the test compared to the control sites. Conclusion:The present study confirmed that the distance between the implant surface and the outer contour of the buccal alveolar bony crest influenced the degree of resorption of the buccal bone plate. Consequently, in relation to the implant shoulder, the peri-implant mucosa will be established at a more apical level if the distance between the implant surface and the outer contour of the alveolar crest is small
32

Avaliação da incorporação de enxertos ósseos homógenos em humanos: análises histológica e imunoistoquímica

Abla, Marcelo Sabbag [UNESP] 27 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-27Bitstream added on 2014-06-13T19:22:10Z : No. of bitstreams: 1 abla_ms_dr_araca.pdf: 493211 bytes, checksum: 7b996be2b8e49d11e130d4903e67a50b (MD5) / O osso homógeno fresco congelado tem sido utilizado no intuito de substituir o osso autógeno. No entanto as suas propriedades de osteoindução e até mesmo osteocondução não estão bem conceituadas na literatura científica. Esse trabalho teve por objetivo avaliar amostras de tecido ósseo homógeno enxertados em humanos através das análises qualitativas histológica e imunoistoquímica. Para tal, dez pacientes previamente selecionados foram submetidos à cirurgia de reconstrução de defeitos ósseos em espessura, usando enxerto ósseo homógeno em bloco fresco congelado estabilizado e fixado por meio de parafusos bicorticais. Após período de integração de seia meses foi realizado procedimento de reabertura para instalação dos implantes osseointegráveis. Neste momento cirúrgico, amostras do enxerto ósseo foram removidas por meio de broca trefina. As amostras foram fixadas em formol 10%, levadas ao processamento para corte descalcificado em parafina e coradas por hematoxilina e eosina. Realizou-se processamento imunoistoquímico para a expressão da enzima Caspase 3. As lâminas foram levadas à microscopia óptica para realização das análises histológica e imunoistoquímica qualitativas. Os resultados mostraram tecido ósseo não vital, com poucas áreas de deposição de osso neoformado sobre a matriz amorfa, presença de infiltrado inflamatório com áreas de osteomielite e imunomarcação expressiva da enzima Caspase 3. Diante da metodologia empregada e dos resultados obtidos concluiu-se que o enxerto homógeno apresentou somente a propriedade biológica de osteocondução durante a fase de incorporação de seis meses / Allogeneic bone has been used fresh frozen in order to replace bone autograft. However, the properties of osteoinduction and osteoconduction are not even well-regarded in the scientific literature. This work aimed to evaluate samples of homogenous bone grafts in humans by qualitative histological analysis and immunohistochemistry. For this ten pre-selected patients underwent surgical reconstruction of bone defects in thick, homogenous bone graft using fresh frozen block stabilized and fixed by bicortical screws. After integration period of six months reopening procedure was performed for installation of osseointegrated implants. At this surgical time bone graft samples were removed by means of drill trephine. The samples were fixed in formalin 10%, taken to court for processing decalcified paraffin, and stained with hematoxylin and eosin. Immunohistochemistry was performed processing for the expression of the enzyme Caspase 3. The slides were brought to light microscopy to carry out the qualitative histology and immunohistochemistry. The results showed non-vital bone tissue, with few areas of deposition of new bone formation on the amorphous matrix, presence of chronic inflammatory infiltrate with areas of osteomyelitis, and immunostaining expressive of the enzyme Caspase 3. Given the methods employed and the results obtained it was concluded that the graft showed only a homogenous biological property of osteoconduction, during the incorporation of six months
33

Enxertos ósseos homológos em humanos: avaliação imunológica, tomográfica, histológica e histomorfométrica de sua incorporação e capacidade de osseointegrar implantes

Spin Neto, Rubens [UNESP] 19 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-19Bitstream added on 2014-06-13T20:05:26Z : No. of bitstreams: 1 spinneto_r_dr_arafo_parcial.pdf: 65317 bytes, checksum: 275e7069f99f952d335d29b5b32e4e0f (MD5) Bitstreams deleted on 2015-06-25T13:01:11Z: spinneto_r_dr_arafo_parcial.pdf,. Added 1 bitstream(s) on 2015-06-25T13:03:27Z : No. of bitstreams: 1 000681242_20160919.pdf: 65168 bytes, checksum: eeb0f0531797627ec3d5057c70d2c3e8 (MD5) Bitstreams deleted on 2016-09-19T11:17:07Z: 000681242_20160919.pdf,. Added 1 bitstream(s) on 2016-09-19T11:17:40Z : No. of bitstreams: 1 000681242.pdf: 3371933 bytes, checksum: 68a515cba0d4f0cc221856293f73c5d7 (MD5) / O objetivo deste estudo foi avaliar, em humanos, a incorporação do enxerto ósseo homólogo e sua capacidade de osseointegrar implantes de titânio, por meio de análise tomográfica, histológica e histomorfométrica, além de fazer uma avaliação imunológica sistêmica, buscando fatores que indiquem a ocorrência de resposta imune contra esses enxertos, seguindo sua implantação. Para tal foram avaliados 35 pacientes, sendo que 15 foram submetidos a enxertos ósseos autólogos e 20 a enxertos ósseos homólogos, que passaram por avaliação tomográfica (antes, imediatamente após e seis meses depois da realização desses enxertos), por exames imunológicos (hemograma associado às dosagens séricas de TNF-α, IFN-γ, IL-1β e IL-10) anteriormente, e 15, 30 90 e 180 dias após a realização dos enxertos e nos quais foram feitas biópsias, tanto do tecido ósseo (no momento da reabertura dos enxertos para instalação dos implantes) quanto do tecido ósseo com um mini-implante instalado (biopsiado no momento da reabertura da região para instalação de cicatrizadores). Os resultados demonstraram remodelação mais lenta do biomaterial homólogo, em comparação ao autólogo, associada a um maior índice de reabsorção nos seis primeiros meses pós-enxertia, sem alterações hematológicas ou sorológicas relevantes. Os parâmetros associados à osseointegração dos mini-implantes (contato osso implante e área óssea entre as roscas) também foram semelhantes entre os dois grupos tratados. Conclui-se que, dentro das condições experimentais deste estudo, o enxerto ósseo homólogo mostrou-se inferior ao enxerto ósseo autólogo, com processo de incorporação mais lenta, também relacionado a uma maior reabsorção óssea radiográfica, aos seis meses pós-enxertia, e sem alterações hematológicas ou sorológicas... / The purpose of this study was to evaluate, in humans, fresh-frozen allogeneic bone grafts incorporation and its capacity of implants osseointegration, using tomographic, histological and histomorphometric evaluation, also looking for signs of systemic immune reaction toward these grafts. For this, we evaluated 35 patients, 15 treated with autologous bone grafts and 20 with fresh-frozen allogeneic bone grafts, who underwent CBCT evaluation (before, immediately after and six months after the completion of these grafts), immunological tests (blood count associated with serum TNF-α, IFN-γ, IL-1β and IL-10), before and 15, 30 90 and 180 days after the graft, and in whom biopsies were taken from both the bone (at the time of reopening grafts for installation of the implants) and the bone tissue with a mini-implant installed (biopsied at the time of reopening the area for installation of healing abutments). Results showed a slower remodeling rate for fresh-frozen allogeneic bone grafts, compared to the autologous material, associated with a higher resorption rate in the first six months post-grafting, with no significant hematological or serum alteration. The parameters associated with mini-implants osseointegration (bone-to-implant contact and bone area between the threads) were also similar between the two studied groups. We conclude that, under the experimental conditions of this study, the fresh-frozen allogeneic bone grafts proved to be inferior to autologous bone graft, with a lower incorporation process, and an increased resorption six months post-grafting, with no significant alterations in blood cell populations or sera. The short term assessment of the parameters related to osseointegration also showed similarity between the groups
34

Enxertos ósseos homológos em humanos : avaliação imunológica, tomográfica, histológica e histomorfométrica de sua incorporação e capacidade de osseointegrar implantes /

Spin Neto, Rubens. January 2011 (has links)
Orientador: Elcio Marcantonio Junior / Coorientador: Luis Antonio Violin Dias Pereira / Banca: Gulnara Scaf / Banca: Joni Augusto Cirelli / Banca: Luiz Antonio Pugliesi Alves de Lima / Banca: Luiz Antonio Salata / Resumo: O objetivo deste estudo foi avaliar, em humanos, a incorporação do enxerto ósseo homólogo e sua capacidade de osseointegrar implantes de titânio, por meio de análise tomográfica, histológica e histomorfométrica, além de fazer uma avaliação imunológica sistêmica, buscando fatores que indiquem a ocorrência de resposta imune contra esses enxertos, seguindo sua implantação. Para tal foram avaliados 35 pacientes, sendo que 15 foram submetidos a enxertos ósseos autólogos e 20 a enxertos ósseos homólogos, que passaram por avaliação tomográfica (antes, imediatamente após e seis meses depois da realização desses enxertos), por exames imunológicos (hemograma associado às dosagens séricas de TNF-α, IFN-γ, IL-1β e IL-10) anteriormente, e 15, 30 90 e 180 dias após a realização dos enxertos e nos quais foram feitas biópsias, tanto do tecido ósseo (no momento da reabertura dos enxertos para instalação dos implantes) quanto do tecido ósseo com um mini-implante instalado (biopsiado no momento da reabertura da região para instalação de cicatrizadores). Os resultados demonstraram remodelação mais lenta do biomaterial homólogo, em comparação ao autólogo, associada a um maior índice de reabsorção nos seis primeiros meses pós-enxertia, sem alterações hematológicas ou sorológicas relevantes. Os parâmetros associados à osseointegração dos mini-implantes (contato osso implante e área óssea entre as roscas) também foram semelhantes entre os dois grupos tratados. Conclui-se que, dentro das condições experimentais deste estudo, o enxerto ósseo homólogo mostrou-se inferior ao enxerto ósseo autólogo, com processo de incorporação mais lenta, também relacionado a uma maior reabsorção óssea radiográfica, aos seis meses pós-enxertia, e sem alterações hematológicas ou sorológicas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate, in humans, fresh-frozen allogeneic bone grafts incorporation and its capacity of implants osseointegration, using tomographic, histological and histomorphometric evaluation, also looking for signs of systemic immune reaction toward these grafts. For this, we evaluated 35 patients, 15 treated with autologous bone grafts and 20 with fresh-frozen allogeneic bone grafts, who underwent CBCT evaluation (before, immediately after and six months after the completion of these grafts), immunological tests (blood count associated with serum TNF-α, IFN-γ, IL-1β and IL-10), before and 15, 30 90 and 180 days after the graft, and in whom biopsies were taken from both the bone (at the time of reopening grafts for installation of the implants) and the bone tissue with a mini-implant installed (biopsied at the time of reopening the area for installation of healing abutments). Results showed a slower remodeling rate for fresh-frozen allogeneic bone grafts, compared to the autologous material, associated with a higher resorption rate in the first six months post-grafting, with no significant hematological or serum alteration. The parameters associated with mini-implants osseointegration (bone-to-implant contact and bone area between the threads) were also similar between the two studied groups. We conclude that, under the experimental conditions of this study, the fresh-frozen allogeneic bone grafts proved to be inferior to autologous bone graft, with a lower incorporation process, and an increased resorption six months post-grafting, with no significant alterations in blood cell populations or sera. The short term assessment of the parameters related to osseointegration also showed similarity between the groups / Doutor
35

Fresamento corretivo de estruturas implanto-retidas : influencia na adaptação marginal e na confiabilidade do teste do parafuso unico / Multi-unit implant-supported frameworks corrective finishing : influence on the marginal misfit and reliability of single-screw test

Daroz, Luiz Gustavo Dias 24 February 2006 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T09:25:51Z (GMT). No. of bitstreams: 1 Daroz_LuizGustavoDias_M.pdf: 1050394 bytes, checksum: 25c85e7dd89cc812e9e871cdc982a3a1 (MD5) Previous issue date: 2006 / Resumo: A obtenção de uma peça perfeitamente adaptada aos componentes de retenção, mantendo a resistência estrutural a custo acessível é o principal objetivo durante a construção de uma prótese implanto-retida de múltiplos elementos. Além disto, julgar a qualidade da adaptação das peças depende da confiabilidade dos métodos existentes para determinação da passividade. O objetivo deste estudo foi determinar o desajuste marginal de infra-estruturas metálicas implanto-retidas tipo monobloco antes e após o fresamento corretivo destas peças empregando retificador manual. Avaliou-se ainda a hipótese de que os procedimentos de fresamento corretivo podem ter influência sobre a confiabilidade do teste do parafuso único utilizado para averiguação de adaptação marginal de peças múltiplas sobre implantes. Foram confeccionadas 40 infra-estruturas metálicas pela técnica do monobloco, sendo 20 fundidas em titânio comercialmente puro (Ti c.p.) e outras 20 fundidas em liga de cobalto-cromo (Cr-Cr). Para tal, utilizou-se matriz metálica simulando a disposição clínica de implantes osseointegrados na região interforames mentonianos contendo 5 análogos de pilares cônicos para peças múltiplas padrão Branemark (Micro-Unit - Conexão) e cilindros protéticos calcináveis compatíveis. As peças confeccionadas em Ti c.p. e em Co-Cr, foram subdivididas em 2 subgrupos (n=10) de acordo com a seqüência de retificação a que foram impostas: Seqüência A ¿ fresamento corretivo das bordas de adaptação dos cilindros protéticos seguido do fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar; e, Seqüência B ¿ fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar seguido do fresamento corretivo das bordas de adaptação dos cilindros protéticos. A conduta forneceu um total de 4 grupos experimentais (Titânio A e B; Co-Cr A e B). As leituras de desajuste marginal, realizadas sobre a matriz metálica e com auxílio de um microscópio mensurador, foram baseadas na técnica do parafuso único e realizadas em cada estrutura antes e após cada etapa de retificação corretiva. As médias de desajuste marginal de cada estrutura foram calculadas e consideradas como uma unidade para a análise estatística. O teste de Friedman foi aplicado com nível de significância de 5% para avaliar o efeito dos diferentes passos de retificação sobre o desajuste marginal. Nos Grupos Ti A e B, assim como no Grupo Co-Cr A, não foi observada diferença significativa entre as condições experimentais (Grupo Ti A, p=0,9048; Grupo Ti B, p=0,273 e Grupo Co-Cr A, p=0,4966). Porém, diferenças estatisticamente significativas foram observadas no Grupo Co-Cr B, após a retificação corretiva das bordas dos cilindros fundidos (p=0,0017). Foi concluído que os procedimentos de fresamento corretivo não mostraram efeito significativo sobre a adaptação marginal das pecas de titânio. Contudo, em um grupo de peças fundidas em Co-Cr, a retificação das bordas dos cilindros mostrou efeito adverso sobre a passividade. Os procedimentos de fresamento corretivo parecem não apresentar influência significativa sobre a confiabilidade do teste do parafuso único, porém, devem ser realizados cuidadosamente, necessitando de aperfeiçoamentos para uma utilização segura / Abstract: The fabrication of a passively fitting framework over abutments and fixtures, maintaining its structural integrity and with a low costs, is the ultimate goal of the construction process of a multi-unit implant-support prosthesis. Furthermore, the accuracy and reliability of the passive fit determination methods have a crucial hole on framework misfit analysis. The objective was to evaluate the passive fit by the single-screw test method of cast commercially pure titanium (CP Ti) implantsupported frameworks after the corrective finishing of cast cylinders fitting borders and screw seats. The hypothesis tested was that finishing procedures could affect the single screw test measurements reliability. Were fabricated 40 frameworks by onepiece casting method, being 20 CP Ti frameworks and others 20 Co-Cr frameworks. A metallic index containing 05 Branemark-type multi-unit abutment analogs and respective calcinable cylinders were used to frameworks fabrication. The CP Ti and Co-Cr frames were assembled in 2 sub-groups (n=10) accordingly with the finishing sequence proposed: Group A - corrective finishing of cast cylinder borders followed by corrective finishing of cast cylinder screw seats - and Group B - corrective finishing of cast cylinder screw seats followed by corrective finishing of cast cylinder borders-. This conduct produce 4 experimental groups (CPTi A and B; Co-Cr A and B). The marginal gaps, assessed over the metallic matrix using a traveling microscope, were carried out before and after each corrective finishing step accordingly with one screw test protocol. The marginal misfit means of each framework was considered as a unit to statistical analyses. The Friedman¿s test was used with significance level set as 5% to analyze the effect of the different corrective finishing steps over frameworks passive fit. In the CPTi A and B Groups, and in the Co-Cr A Group, there was no significant differences between experimental conditions (Group CPTi A, p=0.9048; Group CPTi B, p=0.273 and Grupo Co-Cr A, p=0.4966). However, in the CPTi B Group, a significant difference was found after cast cylinder fitting borders corrective finishing (p=0.0015). It was concluded that the finishing process does not show any effect over Ti framewoks misfit values. However, to a group of Co-Cr frames, the fitting borders corrective finishing has a deleterious effect over passivity. The corrective finishing procedures seamed do not influence the single-screw test reliability, nevertheless, it should be used carefully and requires further improvements to guarantee a sever usage / Mestrado / Protese Dental / Mestre em Clínica Odontológica
36

Protese parcial removivel de extremidade livre associada a um implante osseointegrado : estudo atraves do metodo dos elementos finitos

Rocha, Eduardo Passos 25 June 2001 (has links)
Orientador: Altair A. Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:43:29Z (GMT). No. of bitstreams: 1 Rocha_EduardoPassos_D.pdf: 4550295 bytes, checksum: 68320e2f849e4ffbb6731204012d540e (MD5) Previous issue date: 2001 / Resumo: Os dados sobre a associação entre os implantes osseointegrados e a prótese parcial removível de extremidade livre (PPREL) são poucos e inconclusivos. Devido a isso, foi objetivo deste trabalho avaliar através do método dos elementos finitos bidimensional (MEF) a distribuição das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado - Sistema Branemark - de 10,0 x 3,75 mm, localizado na porção distal do rebordo alveolar, atuando como suporte para a base da PPREL. Para isto, foram criados 3 modelos, que em corte sagital representaram: Modelo A (MA) - Hemiarcada contendo os dentes naturais 33 e 34, e ausência dos dentes 35, 36 e 37; Modelo B (MB) - Semelhante ao MA, com uma PPREL convencional, substituindo os dentes ausentes; Modelo C (MC) - Semelhante ao MB, com um implante na região posterior do rebordo, servindo como suporte. Com o auxílio do programa de elementos finitos, ANSYS 5.5, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. O mapa de tensões evidenciou máxima e mínima concentração de tensões de (MPa): MA (39,668 e 0,005); MB (72,430 e 0,736) e MC (205,662 e 0,057). O deslocamento máximo foi (em mm): MA (0,064); MB (0,107) e MC (0,099). A presença da PPREL (MB) solicitou mais as estruturas de suporte em comparação ao MA; a presença do implante (MC) permitiu níveis de tensão Menores na parte posterior do rebordo alveolar e níveis semelhantes no dente 34, suporte da PPREL, quando comparados aos valores do MB; com níveis elevados de tensão no corpo do implante. Conclui-se Que a presenca da PPREL proporcionou maiores valores de tensão para as estruturas de suporte e Que a presenca do implante osseointearado proporcionou suporte para a base da PPREL. diminuindo a intrusão desta sobre a fibromucosa. promovendo menores níveis de tensão na porcão posterior do rebordo / Abstract: Little is know about the association of osseointegrated implant with a distal extension removable partial denture (DERPD). In view of that, a two-dimensional finite element analysis (FEA) was carried out to study the association of Branemark implant 10. O x 3.75 mm with DERPD, located in the dista! portion of the alveolar edge, acting as support. For this, 3 plane strain models were created, represented in sagital cut: Model A (MA) - Hemiarc containing the natural teeths 33 and 34, and absence of the teeths 35. 36 and 37; Model B (MB) - Similar to MA, with a conventional DERPD; Model C (MC) Similar to MB, with one implant in the retromolar area. The models were loaded with vertical forces of 50 N in finite element program, ANSYS 5.5. The stresses map showed for the maximum and the minimum von Mises stresses, the following values (Mpa), respectively: MA (39.668 and 0.005); MB 72.430 and 0.736) and MC (205.662 AND 0.057). The maximum displacement were (mm): MA (0.064); MB (0.107) and MC (0.099). The presence of DERPD (MB) requested more the support structures in comparison with the MA; the presence of implant (MC) allowed smaller stresses levels in the alveolar edge and similar levels in the tooth 34, support of RPD, when compared to the values of MB; and high levels of stress in the implant body. Thus. the presence of DERPD provided laraer stresses values for the support structures and that the presence of the implant provided support tor the DERPD base. reducina the intrusion on the fibromucosa. promotina smaller stresses levels in the subseauent portion of the edae / Doutorado / Protese Dental / Doutor em Clínica Odontológica
37

Adesão, proliferação e atividade de mineralização de celulas da granulação óssea e fibroblastos gengivais humanos em discos de titânio com diferentes superfícies de tratamento: análise in vitro / Adhesion, proliferation and mineralization activity of bone cells granulation and human gingival fibroblasts on titanium discs with different surface treatment: In vitro analysis

Maria Alejandra Frias Martinez 22 September 2015 (has links)
O objetivo deste estudo foi investigar adesão, proliferação, atividade de fosfatase alcalina e de síntese de matriz mineralizada por células derivadas da granulação óssea (células GO-1) e fibroblastos gengivais humanos (FGH-1) em discos de titânio com diferentes tratamentos de superfícies. Discos de titânio comercialmente puro grau IV foram divididos em 4 grupos de acordo com o tratamento de superfície: (1) discos usinados L (controle); (2) discos usinados seguido de jateamento abrasivo (JATO); (3) discos usinados, jateados e tratados por subtração ácida (superfície NeoPoros NP); (4) discos com tratamento superficial para melhora da hidrofilia (superfície Acqua - ACQ). A microtopografia de superfície dos diferentes tipos de disco de titânio foi avaliada por meio de MEV. A composição química dos discos de titânio de superfícies L, JATO, NP e ACQ foi analisada por espectrometria de energia dispersiva de raios-X (EDS). Para determinar a influência dos diferentes tratamentos de superfície sobre a adesão de células de linhagens fibroblásticas gengivais e osteoblásticas, foram cultivadas células GO-1 e FGH-1 sobre os discos de titânio dos diferentes grupos e as células aderidas foram avaliados por meio de microscopia eletrônica de varredura (MEV) após 24h (adesão) e 48 h (proliferação). No ensaio de mineralização os discos de titânio foram corados com vermelho de alizarina para evidenciação dos nódulos de mineralização. Para avaliação da atividade de fosfatase alcalina, as células FGH-1 e GO-1 foram plaqueadas sobre discos de titânio, a atividade da FA foi observada nas células lisadas usando 25 &#x3BC;l da amostra em placa de 96 poços adicionado com 200 &#x3BC;L de fosfato p-nitrofenol (pNPP) e determinada em espectofotômetro. Não houve diferenças entre os grupos para os parâmetros de rugosidade encontrados nas amostras, com exceção do parâmetro Rsk(asimetria), onde diferenças significantes foram observadas do grupo L em relação aos grupos JATO, NP e ACQ (p< 0.05. Os implantes de superfície L e NP apresentaram apenas Ti, a superfície JATO apresentou, além do Titânio, as substâncias Oxigênio e Alumínio enquanto na superfície ACQ foram observados Titânio, Sódio e Potássio. No período de 24 horas após o cultivo celular, houve maior proliferação de células FGH sobre as superfícies L (89,43% ± 9,13;) e JATO (100%), neste período, observou-se que 100% das superfícies JATO e ACQ estavam recobertas por células GO. Apos 48h diferenças significantes entre o percentual de área recoberta por células FGH nas superfícies JATO comparativamente às superfícies NP e ACQ e, para as células GO, entre as superfícies NP comparativamente às superfícies JATO e ACQ. Houve maior percentual de área recoberta pelas células GO do que pelas células FGH. Houve formação de nódulos mineralizados em todas as superfícies, análise comparativa mostrou diferenças estatisticamente significantes para as células GO cultivadas em DMEM sobre as superficies L (31,45% ± 1,51%) e ACQ (54,94% ± 4,80%). A atividade de fosfatase alcalina foi maior em discos com superfície Lisa e hidrófilica(ACQ). Esses resultados sugerem que todas as superfícies favorecem a adesão e proliferação de fibroblastos gengivais e células osteoblásticas humanas. Superfícies moderadamente rugosas favorecem a maior adesão e proliferação de células osteoblásticas, assim como maior atividade de mineralização in vitro. / The objective of this study was to investigate adhesion, proliferation, alkaline phosphatase activity and matrix synthesis mineralized by cells derived from the bone granulation (GO cells) and human gingival fibroblasts (HGF) in titanium disks with different surface treatment. Titanium discs commercially pure grade IV were used, divided into 4 groups according to the surface treatment: (1) machined discs - L (control); (2) machined discs followed by abrasive blasting (JATO); (3) machined discs, sandblasted and treated by acid subtraction (Neoporos surface - NP); (4) disks with surface treatment to improve the hydrophilic (Acqua surface - ACQ). The surface microtopography of different types of titanium disk was evaluated by SEM. The chemical composition of the surfaces of titanium disks, L, JET, NP and ACQ was analyzed by energy dispersive X-ray spectrometry (EDS). To determine the influence of different surface treatments on the cell adhesion of gingival fibroblast and osteoblast lines were cultured GO-1 and FGH-1 cells on titanium discs of different groups and the adhered cells were assessed by electron microscopy (SEM) after 24 (adherence) and 48 h (proliferation). To test the mineralization titanium disks were stained with alizarin red for disclosure of mineralization nodules. To evaluate the alkaline phosphatase activity, the FGH-1 and GO-1 cells were plated on titanium disks, AP activity was observed in cells lysed using 25 &#x3BC;l of sample in a 96 well plate with 200 &#x3BC;l added phosphate p nitrophenol (pNPP) and determined in spectrophotometer. There were no differences between groups for the roughness parameters found in the samples, except for the parameter Rsk(asimetry) where significant differences were observed in the group L compared to JATO groups, NP and ACQ (p <0.05). The L and NP surface implants had only Ti, JATO surface showed, in addition to titanium, oxygen and the substances aluminum, while the ACQ surface were observed titanium, sodium and potassium. Within 24 hours after cell culturing, there was a greater proliferation of FGH on the cell surface L (89.43 ± 9.13%;) and JATO (100%), in this period, it was observed that 100% of the surfaces JATO and ACQ were covered by GO cells. After 48 hours there were significant differences between the percentage of area covered by FGH cells in JATO surfaces compared to NP surfaces and ACQ, and for GO cells, between NP surfaces compared with the JATO and ACQ surfaces. There was a higher percentage of area covered by GO cells than by FGH cells. There mineralized nodule formation on all surfaces, comparative analysis revealed statistically significant differences for the GO cells cultured in DMEM on the surfaces L (31.45% ± 1.51%) and ACQ (54.94% ± 4.80% ). Alkaline phosphatase activity was higher in discs with a smooth and hydrophilic surfaces (ACQ). These results suggest that all surfaces to promote adhesion and proliferation of gingival fibroblasts and human osteoblastic cells. Moderately rough surfaces leads to high adhesion and proliferation of osteoblast cells, as well as higher mineralization activity in vitro.
38

"Análise das dimensões ósseas peri-orbitárias por meio de tomografia computadorizada visando a colocação de implantes osseointegráveis" / Dimensional analysis of the periorbital regions using computer tomography for osseointegrated implants insertion

Clemente da Silva Fernandes 19 April 2006 (has links)
A Prótese Buco Maxilo Facial é a especialidade da Odontologia responsável pela confecção de próteses intra e extra-bucais, indicadas quando regiões maxilofaciais foram perdidas. Implantes craniofaciais podem servir como ancoragem para próteses faciais, inclusive as óculo-palpebrais. O presente trabalho teve como propósito avaliar o comprimento e a espessura da estrutura óssea da região periorbitária e realizar a validação do método de mensuração proposto. Foram realizadas mensurações lineares de comprimento e largura das corticais ósseas das regiões peri-orbitárias em tomografias computadorizadas de 30 crânios humanos secos. Dois examinadores realizaram as mensurações, duas vezes cada um, com intervalos de no mínimo 7 dias, em pontos de referência determinados de acordo com as horas de um relógio. A análise estatística revelou que, para a grande maioria das medidas, as variações intra e inter-examinadores não apresentaram diferenças significantes (p<0,05), indicando que o método de mensuração proposto é confiável e válido para a mensuração da região peri-orbitária. Verificou-se que os três pontos de maior comprimento seguiram a mesma seqüência anatômica para as órbitas direita e esquerda, localizando-se no rebordo supra-orbitário e sendo compatíveis com a inserção de implantes osseointegráveis intra-bucais. Os três pontos localizados na parede lateral e na região látero-inferior da órbita apresentaram comprimento compatível com a utilização de implantes osseointegráveis intra-bucais. A parede medial de ambas as órbitas não apresentou comprimento favorável à inserção de implantes intra-bucais ou crânio-faciais. Os pontos de maior largura foram observados no rebordo supra-orbitário e na região látero-inferior de ambas as órbitas, e aqueles de menor largura foram encontrados na região látero-superior de ambas as órbitas. / The Maxillofacial Prosthesis is the dental specialty responsible for the confection of extra and intra-oral prosthesis indicated when facial regions have been lost. Craniofacial osseointegrated implants made possible the confection of implantretained facial prosthesis, namely the orbital prosthesis. This work aimed to evaluate the length and the thickness of the bone structure of the periorbital region and to present the validation of the method. Computer tomographies of 30 dry human skulls were made in order to register linear length and width measurements of the periorbital region. Two examiners, two times each one, took the measurements with intervals of at least 7 days between the measurements. Statistics pointed out that, for most instances, the intra and inter-examiners variations were not significant (p<0.05). Therefore, the method proposed is precise and valid for the measurement of the periorbital region. It was verified that the three points with deeper values followed the same anatomical sequence in the supraorbital rim for the right and left orbits, being compatible with the insertion of intraoral osseointegrated implants. The medial wall of both orbits did not present enough length to allow the insertion of intraoral or craniofacial implants. The points of larger width were observed in the supraorbital rim and in the infralateral region of both orbits, and those of smaller width were found in the supralateral region of both orbits.
39

Avaliação da precisão de duas técnicas de união de estruturas metálicas - brasagem e soldagem a laser - em uma prótese clássica de Brånemark pelo método da microscopia eletrônica de varredura (MEV) / Assessment of precision of two union techniques, brazing and laser welding, in metallic structures of a Brånemark classical prosthesis using the sweeping electronic microscopy (SEM)

Lucio Hirokuni Kanashiro 21 September 2005 (has links)
Este estudo avaliou a precisão de duas técnicas de união, a brasagem e a soldagem a laser, em estruturas metálicas de uma prótese clássica de Brånemark. Dez estruturas fundidas em NiCr foram segmentadas em 4 partes e analisadas no MEV em pontos pré-estabelecidos, vestibular e proximal, totalizando 8 pontos de análise para cada estrutura. Na primeira fase, foi mensurada a fenda marginal existente entre o análogo do implante e o abutment UCLA antes da união destes segmentos através da brasagem e da soldagem a laser. Após esta análise inicial, as 10 estruturas foram divididas aleatoriamente em dois grupos. O grupo que seria unido pelo processo da brasagem, utilizando maçarico gás/oxigênio, apresentou uma fenda marginal média de 5,94µm, já o grupo que seria unido através da soldagem a laser, uma fenda marginal média de 7,22µm. Os segmentos de cada estrutura metálica foram parafusados com 10Ncm aos respectivos análogos da plataforma de trabalho e unidos com resina acrílica Pattern Resin LS (GC America Inc, USA). Após a polimerização da resina, a estrutura foi desparafusada e submetida ao processo da brasagem ou da soldagem a laser e analisada no MEV nas mesmas posições pré-estabelecidas antes da união. Esta análise foi realizada na mesma plataforma de trabalho. Para tal, os quatro parafusos de fixação foram rotacionados até que fosse detectada uma leve resistência. Neste momento, somente o parafuso de uma das extremidades recebeu um torque de 10Ncm e os demais parafusos foram soltos. A média das fendas marginais após o processo da brasagem passou a ser de 18,80µm e a média das fendas marginais após a soldagem a laser passou a ser de 12,38µm. A análise de covariância mostrou que a diferença das fendas depois e antes da união através da brasagem foi maior que a diferença das fendas obtidas através da soldagem a laser (p = 0,001). Apesar da brasagem apresentar uma distorção significativamente maior quando comparada à soldagem a laser, ambas mostraram valores de fenda marginal clinicamente aceitáveis. No entanto, ficou evidente a facilidade de execução da técnica a laser em relação à brasagem, principalmente no que tange ao tempo necessário para a realização de cada uma delas. / In this study we assess precision of two union techniques, brazing and laser welding, in metallic structures of a Brånemark classical prosthesis. Ten structures cast in NiCr were segmented in four parts and analyzed in the SEM in pre-established points, vestibular and proximal, in a total of 8 analysis points for each structure. In this first phase, we measured the marginal fissure between the implant analogous and the UCLA abutment before the union of these segments using brazing and laser welding. After this initial analysis, we randomly divided the ten structures in two groups. The group that would be united by the process of brazing, using gas/oxygen blowpipe, presented an average marginal fissure of 5,94µm and the group that would be united by laser welding, an average marginal fissure of 7,22µm. The segments of each metallic structure were screwed with 10Ncm to the respective analogous of the work platform and united with acrylic resin Pattern Resin LS (GC America Inc., USA). After polymerization of the resin, the structure was unscrewed and submitted to process of brazing or laser welding and analyzed in the SEM in the same positions pre-established before the union. This analysis was made in the same work platform. To do so we rotated the four fixation screws until we felt a light resistance. At this moment, only the screw of one of the edges received a torque of 10Ncm and the other screws were released. The average of the marginal fissures after the brazing process was 18,80 µm and the average of the marginal fissures after the laser welding process was 12,38µm. The analysis of the covariance showed that the difference of the fissures after and before the union using brazing was bigger than the difference of the fissures obtained with the laser welding (p = 0,001). Despite the fact that the brazing presents a distortion significantly bigger when compared to the laser welding, both techniques showed clinically acceptable values of marginal fissures. However, it is clear how easy the execution of the laser technique is in relation to the brazing, mainly in relation to the time that is needed for each technique.
40

Análise comparativa do grau de rotação de parafusos para sistema UCLA em estruturas fundidas em monobloco provenientes de \'abutments\' calcináveis e com cinta de Colbato-Cromo / Comparative analysis of the rotational angle degree on UCLA burnout/Cobalt-Chromium machined collar abutment screws for one-piece cast metal frameworks

Butignon, Luis Eduardo 21 May 2007 (has links)
Problemática: De ocorrência clínica bastante comum, o afrouxamento dos parafusos que compõe uma prótese sobre implante é uma complicação que traz transtornos tanto para o profissional quanto para o paciente. Proposição: O objetivo deste estudo foi comparar o grau de rotação de parafusos de titânio (grau 5), durante testes de torque, re-torque e os valores de destorque (Ncm), sobre infra-estruturas fundidas em monobloco, a partir de abutments tipo UCLA totalmente calcináveis e com cinta usinada em Co-Cr. Material e métodos: Um dispositivo leitor da quantidade de graus foi especialmente desenvolvido para este estudo, juntamente com um software . Dois implantes Revolution - SIN de 3,75 mm de diâmetro e 13 mm de comprimento e hexágono externo foram montados na base de um dispositivo e diretamente sobre eles foram obtidos os padrões para fundição dos corpos de prova. Cada corpo de prova foi formado por dois abutments tipo UCLA, totalmente calcináveis ou com cinta em Co-Cr, interligados por uma barra acrílica. Foram obtidos 10 corpos de prova para cada grupo e 40 parafusos de titânio (Grau 5) foram usados para os testes. Obteve-se então a medição do ângulo criado durante o aperto e re-aperto dos parafusos, sendo o re-aperto realizado após 10 minutos do aperto inicial, ambos sob torque de 30Ncm. Após o procedimento de re-aperto, o valor de destoque era imediatamente aferido e anotado em Ncm, possibilitando avaliar a quantidade de torque retido pelo parafuso após o procedimento, sendo esta seqüência realizada 3 vezes para cada corpo de prova. Análises em MEV foram realizadas nas bases de assentamento dos abutments antes e após a realização dos testes, assim como na superfície dos parafusos, a fim de se encontrar eventuais danos na microestrutura dos mesmos. O teste ?t? de student foi aplicado para uma avaliação entre os grupos e o teste ANOVA a um critério foi utilizado para análise intra-grupo. Resultados: Os resultados revelaram que durante os procedimentos de torque (aperto), os parafusos empregados em infra-estruturas obtidas a partir de abutments totalmente calcináveis apresentaram um maior grau de rotação (ensaio1: 61,664°; ensaio 2: 47,718°; ensaio 3: 47,374°), quando comparados aos parafusos empregados em infra-estruturas obtidas de abutments com cinta usinada em Co-Cr (ensaio 1: 49,038°; ensaio 2: 41,636°; ensaio 3: 43,273°), sendo a diferença entre os grupos estatisticamente significante em todos os ensaios realizados; P<0,05. Além disso, em ambos os grupos, a maior rotação dos parafusos ocorreu no primeiro aperto dos mesmos tanto durante o procedimento de torque quanto no procedimento de re-torque. Durante o re-torque, o ângulo formado na cabeça dos parafusos também foi sempre maior para o grupo Acrílico Calcinável (ensaio 1: 14,591°; ensaio 2: 12,987°; ensaio 3: 13,095°), comparado ao grupo Co-Cr (ensaio 1: 11,481°; ensaio 2: 10,117°; ensaio 3: 12,213°), sendo que diferença estatisticamente significante foi encontrada entre os ensaio 1 e 2; P<0,05. Os valores médios de destorque (quantidade de torque retido durante o aperto dos parafusos) também foram sempre maiores para o grupo Acrílico Calcinável (ensaio 1: 27,325Ncm; ensaio 2: 27,050Ncm; ensaio 3: 26,975Ncm), quando comparado ao grupo Co-Cr (ensaio 1: 26,250Ncm; ensaio 2: 26,975Ncm; ensaio 3: 26,400Ncm), porém sem diferença estatisticamente significante. As Imagens obtidas das análises em MEV demonstraram que as superfícies das bases de assentamentos do abutments obtidos a partir de abutments totalmente calcináveis apresentaram grandes irregularidades superficiais, comparadas às obtidas a partir de bases usinadas em Co-Cr, as quais apresentaram um padrão mais liso e uniforme. Quanto à análise dos parafusos, foi encontrado que as maiores deformações dos mesmos ocorrem na base de assentamento de sua cabeça no interior do abutments assim como na região da sua primeira rosca (apical). Conclusões: Tanto para o momento de torque quanto para o momento de re-torque, infra-estruturas do grupo Acrílico Calcinável permitiram maior rotação dos parafusos dos abutments, quando comparados com o grupo Co-Cr. Na análise dos valores de destorque, estatisticamente os grupos foram considerados semelhantes. Imagens em MEV, antes da realização dos testes de torque, re-torque e destorque revelaram que a base de assentamento do grupo Acrílico Calcinável apresentou aspecto mais irregular da fundição quando comparado ao grupo Co-Cr. Em ambos os grupos, partículas de titânio foram encontradas incrustadas nestas bases de assentamento após a realização desses testes, segundo dados do EDS. As imagem em MEV revelaram ainda que os parafusos se deformam principalmente na base de sua cabeça que se assenta no interior dos abutments, assim como na região da sua primeira rosca(apical). / Problem: The abutment screw loosening is a common drawback which concerns both patients and practitioners. Purpose: The aim of this study is to compare the rotational angle degree of Grade V titanium screws during torque, retorque and detorque steps (Ncm) on one-piece cast metal frameworks obtained from UCLA burnout/Co-Cr machined collar abutments. Material and methods: Two external hexagonal implants with 3.75mm in diameter and 13mm in length (Revolution, SIN) were secured to a metallic base and the wax patterns directly fabricated over them. The UCLA burnout/ Co-Cr machined collar abutments were screwed to the implants and joined together with an acrylic resin bar. Ten samples for each abutment type were fabricated. Forty Grade V titanium screws were used in the test. The rotation angle degree was measured with the aid of an specially constructed device and a computer software, during torque and retorque procedures, being the retorque made 10 minutes after the initial torque, both under 30Ncm. After the retorque procedures, the detorque values were measured. The overall sequence (torque, retorque, and detorque) was made three times for each sample. SEM analysis at the implant-abutment interfaces were made before and after the tests, as well as on the screw surfaces to detect possible microdamaging. The Student?s t test was used for between group analyses and the one-way ANOVA test for within group analyses. Results: The rotational angle degree was higher for screws used in the UCLA burnout (test 1: 61,664°; test 2: 47,718°; test 3: 47,374°) than in the Co-Cr machined collar abutments (test 1: 49,038°; test 2: 41,636°; test 3: 43,273°) (P<.05). The highest rotational degree values were observed on the first screwing during torque and retorque procedures. During retorque, the angle formed on the screw head was higher for the UCLA burnout (test 1: 14,591°; test 2: 12,987°; test 3: 13,095°) than the Co-Cr machined collar abutments (test 1: 11,481°; test 2: 10,117°; test 3: 12,213°), being these differences statistically significant between the first and second screwing (P<.05). The mean detorque values were higher in the UCLA burnout (test 1: 27,325Ncm; test 2: 27,050Ncm; test 3: 26,975Ncm) than in the Co-Cr machined collar screw abutments (test 1: 26,250Ncm; test 2: 26,975Ncm; test 3: 26,400Ncm), but not statistically significant. The SEM images demonstrated that the seating surface of the UCLA burnout abutments presented greater irregularities than the Co-Cr machined collar surfaces, which present a more smooth and flat pattern. Greater deformations were found at the seating abutment screw undersurfaces and in the first apical thread as well. Conclusions: The rotational degree was higher in the torque and retorque procedures for UCLA burnout than in the Co-Cr machined collar screw abutments. The detorque values were similar in both groups. The SEM images before torque, retorque and detorque procedures revealed more surface irregularities in the UCLA burnout abutments. In both groups, titanium debris were found in the seating abutment platforms after the tests by EDS images. The SEM images revealed that the abutment screws suffer deformation in the abutment head undersurface as well as in their first apical threads.

Page generated in 0.0764 seconds