• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 1
  • Tagged with
  • 17
  • 17
  • 17
  • 17
  • 11
  • 11
  • 9
  • 9
  • 9
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia do remanescente dental do termino gengival e da retenção intra-radicular na resistencia a fratura de restaurações proteicas

Carlini Junior, Bruno 23 October 2001 (has links)
Orientador : Luis Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:36:23Z (GMT). No. of bitstreams: 1 CarliniJunior_Bruno_D.pdf: 4989185 bytes, checksum: 746f907f11f3e05fc033d327df974b66 (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar o padrão e a resistência à fratura de dentes bovinos tratados endodonticamente e restaurados através de coroas unitárias metálicas nas seguintes condições experimentais: presença ou não de remanescente dental coronário com 2 mm de comprimento; término gengival em ombro-biselado, chanfrado e ombro; e dois métodos de retenção intra-coronária, núcleo metálico fundido e pino metálico pré-fabricado paralelo rosqueado. Cento e vinte raízes bovinas receberem tratamento endodôntico e foram fixadas em cilindros de resina acrílica por meio de ligamento periodontal artificial para serem submetidas ao carregamento tangencial de compressão a 0,5 mm/min e 135°, até ocorrer a fratura. Os resultados (ANOVAI DMMQ a=0,05) demonstraram que houve diferença estatística para as condições término gengival (ombro biselado >=chanfrado> ombro), retenção intra-radicular (pino pré-fabricado> núcleo metálico fundido) e presença de remanescente coronário (com remanescente> sem remanescente); bem como para as interações remanescente x pino e remanescente x término, em que os grupos com remanescente apresentaram valores superiores aos grupos sem remanescente, com diferença estatística significativa. Foi possível concluir que a resistência mecânica de raízes reconstruídas proteticamente tem relação com a quantidade de remanescente coronário, método de retenção intra-radicular e formato de término gengival / Abstract: The aim of this study was to evaluate both the pattern and the fracture strength of bovine teeth endodontically treated through metallic unitary crowns under the following experimental conditions: presence or not of dental coronal structure with 2mm in length; cervical beveled shoulder, chamfered and shoulder; and two methods of intraradicular retention, cast post and core and parallel threaded prefabricated metallic posts. Endodontically treated 120 bovine dental roots were fixed to acrylic resin cylinders by means of artificial periodontal ligament, and then submitted to the compressive strength, at 1350 and 0,5 mm/min, until reaching the fracture. The results (ANOVA/ DMMQ a=0,05) showed statistical significance for the following conditions: cervical prosthetic design (beveled sholder >=chanfer > sholder), intraradicular retention (prefabricated posts > cast post and core) and coronal structure (with 2 mm of coronal structure > without dental structure); It was possible to conclude that the mechanical resistance of the restored roots is correlated with the amount of coronary dental structure, the intra-radicular retention method, and the prosthetic gingival shape / Doutorado / Dentística / Doutor em Clínica Odontológica
2

Influencia da altura do remanescente coronario e do tipo de retenção intra-radicular na resistencia e modo de fratura de raizes bovinas restauradas com coroas totais

Resende, Cristina do Amparo 24 January 2005 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:54:21Z (GMT). No. of bitstreams: 1 Resende_CristinadoAmparo_M.pdf: 828266 bytes, checksum: 67ff65721ab9a2c7931bd0a2be4a3001 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar a influência da altura do remanescente coronário e de diferentes tipos de retenções intra-radiculares na resistência à fratura de raízes bovinas restauradas com coroas totais confeccionadas em resina composta laboratorial nas seguintes condições: ausência de remanescente coronário ou presença de um ou dois milímetros e cinco métodos de retenção intra-radicular. Cento e cinqüenta dentes bovinos foram selecionados padronizando-se as dimensões das raízes. As coroas foram seccionadas e as raízes remanescentes receberam tratamento endodôntico e foram divididas, aleatoriamente, em quinze experimentais (n=10): G1 - pino de fibra de vidro (FV) e 0 mm; G2 - FV e 1 mm; G3 - FV e 2 mm; G4 - pino pré-fabricado metálico (PM) e 0 mm; G5 - PM e 1 mm; G6 - PM e 2 mm; G7 - pino de fibra de carbono (FC) e 0 mm; G8 - FC e 1 mm; G9 - FC e 2 mm; G10 - núcleo metálico fundido (NMF) e 0 mm; G11 - NMF e 1 mm; G12 - NMF e 2 mm; G13 ¿ preenchimento do canal radicular com resina composta (RC) e 0 mm; G14 - RC e 1 mm; G15 - RC e 2 mm. As coroas totais foram cimentadas com cimento resinoso e as raízes foram fixadas em resina poliestirênica, simulando-se o ligamento periodontal com material de moldagem à base de poliéter. As amostras foram submetidas ao carregamento tangencial de compressão, sob um ângulo de 135o a 0,5 mm/min até ocorrer a fratura. Os resultados (ANOVA / Tukey a=0,05) demonstraram que na ausência de remanescente, o grupo RC apresentou os maiores valores de resistência à fratura, não diferindo estatisticamente dos grupos restaurados com FC, FV e PM; o grupo restaurado com NMF apresentou os menores valores médios de resistência à fratura. Na presença de 1 mm de remanescente o grupo PM apresentou os maiores valores de resistência à fratura, não diferindo estatisticamente dos grupos restaurados com FV, NMF e RC e o grupo FC apresentou os menores valores médios. Na presença de 2 mm de remanescente, os diferentes tipos de retenções não promoveram diferenças entre os valores médios de resistência à fratura. Para os grupos restaurados com FV, FC e NMF, a altura do remanescente não influenciou nos resultados. Para os grupos PM, a altura de 1 mm proporcionou os maiores valores de resistência à fratura e o grupo com 2 mm de remanescente apresentou os menores valores. No grupo RC, a ausência de remanescente dental coronário promoveu os melhores resultados e o grupo com 1 mm de remanescente apresentou os piores resultados. A análise geral dos padrões de fratura demonstrou que 68% das fraturas atingiram os terços apical ou médio. Os grupos restaurados com pinos de fibra de vidro apresentaram os melhores padrões de fratura, enquanto os restaurados apenas com resina composta apresentaram os piores padrões de fratura / Abstract: The purpose of this study was to evaluate the influence of dental coronal structure height and different types of intraradicular retention on the fracture strength of bovine roots restored with total crowns made of laboratory composite resin under the following conditions: absence of dental coronal structure or presence of one or two millimeters, and five methods of intraradicular retention. One hundred fifty bovine teeth were chosen and the canal size was standardized. The crowns were sectioned and the canals were treated endodontically and the specimens distributed randomly into 15 experimental groups: G1 ¿ fiberglass post (FV) and 0 mm; G2 ¿ FV and 1 mm; G3 ¿ FV and 2 mm; G4 ¿ prefabricated metal post (PM) and 0 mm; G5 ¿ (PM) and 1 mm; G6 ¿ (PM) and 2 mm; G7 ¿ carbon fiber post (FC) and 0 mm; G8 ¿ (FC) and 1 mm; G9 ¿ (FC) 1 mm; G15 ¿ RC and 2 mm. Total crowns were luted with resin cement and the roots were fixed in resin blocks and artificial periodontal ligament was simulated with casting material made of polyether. The specimens were submitted to compressive strength test at 135o and 0.5 mm/min until fracture occurred. The results (ANOVA / Tukey a=0.05), showed that in absence of dental coronal structure, the group RC presented the most fracture strength values, not differing statistically from groups restored by FC, FV and PM, and the group restored by NMF presented the lowest mean values. In the presence of 1 mm, Group PM presented the highest fracture strength values, not differing statistically from groups restored by FV, NMF and RC, and the group restored by FC presented the lowest mean values. In the presence of 2 mm, the different types of intraradicular retentions did not cause differences among mean fracture strength values. In the groups restored by FV, FC and NMF, the dental coronal structure height had no influence on the results. In the PM group, the height of 1 mm, showed the highest and the group with 2 mm presented the lowest mean values. In the group RC the absence of dental coronal structure showed the best results and the group with 1 mm presented the worst results. The general fracture pattern analysis showed that 68% of fractures involved the gingival and apical thirds. The groups restored by FV showed the best fracture patterns, and the groups restored by RC, the worst / Mestrado / Dentística / Mestre em Clínica Odontológica
3

Extensometria: estudo das deformações ao redor de três implantes cone morse, com posicionamento linear, sob carga axial

Abreu, Celina Wanderley de [UNESP] 03 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-03Bitstream added on 2014-06-13T18:58:12Z : No. of bitstreams: 1 abreu_cw_me_sjc.pdf: 508442 bytes, checksum: 720d525ea366cc2fd0575e67a37ba04e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo desse estudo foi avaliar a aplicação de carga e distribuição das microdeformações ao redor de implantes com conexão protética cone morse. Três implantes foram inseridos num bloco de poliuretano e pilares microunit foram instalados nos implantes com torque de 20 Ncm. Três coifas usinadas foram adaptadas nos pilares para configurar a supraestrutura protética (n=5) e comparar com as supra-estruturas obtidas com coifas plásticas. Quatro extensômetros foram colados na superfície superior do bloco. Uma carga vertical estática de 30 Kg foi aplicada em cinco pontos das supra-estruturas. Os registros obtidos dos extensômetros foram submetidos ao teste estatístico ANOVA e Tukey (α=5%). As medidas derivadas dessa simulação revelaram que durante a aplicação de carga: (1) existiu uma relação direta do local de aplicação e na distribuição da microdeformação ao redor dos implantes; (2) não existiu diferença na microdeformação entre coifas plásticas e usinadas. / The aim of this study was to evaluate the load transfer and strain distribution by an implant-supported fixed partial prosthesis. Three implants Morse Taper were inserted in a polyurethane block and abutments microunit were installed on the implants with a torque of 20 Ncm. Plastic cylinders and prefabricated cylinders were adapted on abutments to fabricate the framework (n=5). Four strain gauges were attached on the superior surface of the block and then each framework was tight on the abutments with a torque of 10 Ncm and vertical load of 30Kg was applied to five points on the framework. The data obtained in the strain gauge analysis were submitted to the statistical tests ANOVA and Tukey (α=5%). The measurements derived from this simulation revealed that: (1) there was a direct proportion between the strain distribution in the metal framework and stresses created in the supporting structure around the implants; (2) there was not a strain difference between plastic and prefabricated cylinders during the load transfer
4

Estudo da densidade óptica e da resistência à flexão de três pontos em corpos-de-prova fundidos com a liga metálica High Bond (Co-Cr), com secções vertical 90°, diagonal 45° e diagonal 22,5°, soldados pelas técnicas convencional e TIG

Pereira, Leonardo Viana [UNESP] 06 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-06Bitstream added on 2014-06-13T19:58:25Z : No. of bitstreams: 1 000738161.pdf: 8215678 bytes, checksum: 0fb4df9ab1185429ce16edda73d5c2b2 (MD5) / O sucesso das próteses sobreimplantes está diretamente relacionado ao grau de adaptação dos componentes protéticos aos implantes. Com a finalidade de se obter um assentamento passivo entre a prótese e os implantes, as estruturas metálicas são confeccionadas inicialmente segmentadas e, posteriormente, soldadas clinicamente para minimizar as distorções do processo de fundição. O sistema TIG (Tungsten Inert Gas) é definido como uma soldagem de arco elétrico, estabelecido entre um eletrodo não consumível à base de tungstênio e a peça a ser soldada. O propósito desse estudo foi, através do uso da densidade óptica e de um teste mecânico de resistência à flexão de 3 pontos, analisando a rigidez do material e a tensão de flexão, verificar o comportamento de dois sistemas de soldas odontológicas: convencional e TIG, realizadas em diferentes angulações (90°, 45° e 22,5°) de secções das porções a serem soldadas, comparando-os a um grupo fundido em monobloco (controle), em uma liga de Co-Cr. Os grupos foram comparados entre si quanto à densidade óptica, rigidez, tensão de flexão. A análise dos resultados obtidos possibilitou as seguintes conclusões: 1. Em relação à análise dos dados da densidade óptica mostrou que o grupo controle apresentou-se mais eficientes, estatisticamente significantes, quando comparadas aos grupos do sistema de solda TIG; não houve diferenças estatisticamente significantes entre as diferentes angulações num mesmo sistema de soldagem, porém quando comparados os sistemas de soldagem numa mesma angulação, o grupo de 22,5°-solda convencional teve resultado melhor, estatisticamente significante, que o 22,5°-solda TIG; 2. Em relação à rigidez (modulo de elasticidade), houve diferença estatisticamente significante apenas quando se comparou os corpos com angulação de 90° com diferentes soldas, tendo resultados maiores com... / The success of the prosthesis over implant is directly related to the adaptation degree of the prosthesis components to implants. Aiming to obtain a passive fit between the prosthesis and the implant, initially the metal structures are segmented and later are clinically welded to minimize the distortions of the casting process. The TIG system (Tungsten Inert Gas) is defined as a welding of an electric arc, established between a non consumable electrode based on tungsten and the part to be welded. The purpose of this study was to use the optical density and a mechanical test of 3 points flexion endurance, to analyze the stiffness of the material and the bending stress and to verify the behavior of two systems of dental welders: conventional and TIG performed at different angles (90º, 45º e 22, 5º) of the sections of the portions to be welded, and compare them to a group fused on monobloc (control) in an alloy of Co-Cr. The groups were compared on optical density, stiffness and bending stress. Analysis of the results made possible the following conclusions: 1. The analysis of the data showed that the optical density of the control group was more efficient, statistically significant, when compared to the groups with TIG welding system; there were no statistical differences between the different angles on the same welding system, although when comparing the welding systems in the same angle, the group of 22,5º- conventional welding had better result than the 22,5º - TIG welding, this difference was statistically significant; 2. There was statistical significant difference regarding the stiffness (modulus of elasticity) only when it was compared the bodies with the 90º angle with different welds, the higher results were with the conventional welding; 3. The results of the...
5

Sistemas CAD/CAM: avaliação da precisão de aquisição de dados

Mello, Caroline Cantieri de [UNESP] 18 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-18Bitstream added on 2015-03-03T12:06:08Z : No. of bitstreams: 1 000795787.pdf: 571234 bytes, checksum: f635d0ca5e8e957bf53c65ab8998057a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal de infraestruturas de próteses fixas confeccionadas pelo Sistema CAD/CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Confeccionaram-se 50 corpos de prova; Convencional (Ni-Cr) (n = 10), GI: iTero (n = 10), GII: CerecBluecam/fresadora industrial (n = 10), GIII: 3S (n = 10) e GIV: CerecBlueCam/Sirona (n = 10). Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal vertical. Resultados: A análise intra observador indicou que não houve diferença estatisticamente significante (teste t pareado, p = 0.822) no período antes e depois das análises. O sistema convencional (321 ?m) apresentou maior desadaptação quando comparado com o sistema CAD/CAM (89 ?m) (p<0.001). O sistema intra oral (iTero) apresentou menor índice de desadaptação marginal, quando comparado com o sistema extra oral (3S), (p<0.001). O sistema aberto apresentou maior índice de desadaptação marginal (114 ?m) quando comparado com intra oral (iTero), sendo p<0.001. Além disto, no sistema convencional, observou-se que os pré-molares apresentaram índice de desadaptação maior quando comparado (361 ?m) com o molar (283 ?m) (p<0.001), porém no sistema CAD/CAM não houve diferença estatisticamente significante na comparação de dentes pré-molares (93,7 ?m) e molares (84,9 ?m). Significância: O sistema CAD/CAM pode atuar mais favoravelmente, reduzindo o índice de desadaptação marginal, quando comparado com o sistema convencional de confecção de próteses dentárias. O sistema intra oral (iTero) comportou-se melhor quando comparado com os demais sistemas. / Objective: The aim of this study was to evaluate the marginal fit of frameworks produced by CAD/CAM systems with three different data acquisition. Material and Methods: We fabricated 50 frameworks: conventional (Ni-Cr) (n = 10), GI:iTero (n = 10), GII:CerecBluecam/industrial milling (n = 10), GIII:3S (n = 10), and GIV:CerecBlueCam/Sirona (n = 10). We numbered the specimens and analyzed them randomly. Results: Intra-observer analysis indicated no statistically significant difference (paired t-test, p = 0.822) before and after the analysis. The conventional system (321 ?m) showed greater misfit than the CAD/CAM (89 ?m) (p<0.001) system. The intraoral system (iTero) showed a lower rate of marginal misfit than the extra-oral system (3S), (p<0.001). The open system presented a higher marginal discrepancy (114 ?m) than intraoral (iTero), with p<0.001. Moreover, in the conventional system, premolars (361 ?m) showed a higher index of misfit than molars (283 ?m) (p<0.001), but for the CAD/CAM system, there was no statistically significant difference between premolars (93.7 ?m) and molars (84.9 ?m). Significance: The CAD/CAM system can to act more favorably reducing the rate of marginal discrepancy than the conventional impression system of dental prosthesis. The intra oral system (iTero) was better than other systems. / FAPESP: 11/06311-5
6

Restaurações cerâmicas minimamente invasivas executadas por cirurgiões dentistas com diferentes níveis de experiência profissional: estudo clínico cego, longitudinal e prospectivo

Melo, Régis Alexandre da Cunha [UNESP] 27 July 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-27. Added 1 bitstream(s) on 2016-02-05T18:34:20Z : No. of bitstreams: 1 000857862.pdf: 141657 bytes, checksum: c1cbd779d6d47891f1cd1f7ce4af3ac3 (MD5) Bitstreams deleted on 2016-07-29T12:53:59Z: melo_rac_me_araca.pdf,. Added 1 bitstream(s) on 2016-07-29T12:54:52Z : No. of bitstreams: 1 000857862.pdf: 11011651 bytes, checksum: 5400882cac48c7b0ec5838928d648161 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: Avaliar a influência da experiência profissional de cirurgiões-dentistas na taxa de sobrevida de restaurações cerâmicas delgadas cimentadas sobre dentes anteriores e/ou posteriores. Material e Método: Um total de 16 profissionais em nível de especialização realizaram tratamentos restauradores com cerâmica delgada, que foram divididos em quatro grupos (n=4) de acordo com o tempo de formação profissional - Grupo 1: recém-formados com até 2 anos de formados; Grupo 2: de 2 a 5 anos de formado; Grupo 3: de 5 a 10 anos de formado; Grupo 4: mais de 10 anos de formado. Todos os profissionais foram instruídos e treinados a seguirem o mesmo protocolo clínico de trabalho, embora desconhecessem os objetivos da pesquisa. Um único avaliador acompanhou os atendimentos clínicos realizados em 24 pacientes, totalizando 274 restaurações unitárias em dissilicato de lítio, sendo 158 na região anterior e 116 na posterior, distribuídas entre os arcos maxilar (186) e mandíbular (88). A espessura das cerâmicas variou entre 0,3 mm e 4,0 mm. As intercorrências ocorridas durante a execução dos protocolos clinicos, bem como os tempos de condicionamento ácido, de fotopolimerização e o tipo de cimento foram anotados. As restaurações foram cimentadas com diferentes cimentos em função da espessura da cerâmica, sendo: Rely X U200 (n=120), Rely X Veneer (n=95) e Variolink Veneer (n=58); totalizando 91 coroas totais, 137 facetas com preparo e 46 facetas sem preparo. As avaliações clínicas foram realizadas após a instalação das restaurações e nos controles de 30, 180, 360 dias posteriores à cimentação. Os parâmetros para a avaliação foram baseados nos critérios modificados do USPHS, adaptados ao estudo. Julgou-se insucesso quando houve fratura ou soltura das restaurações. As fraturas foram replicadas e submetidas à análise... / Objective: To evaluate if the dentist experience can influence the survival rate of cemented anterior and/or posterior thin ceramic restorations. Materials and Methods: A total of 16 professionals with different expertise level with thin ceramic restorations were divided into four groups (n=4) - Group 1: up to 2 years of the graduation; Group 2: 2 to 5 years of graduation; Group 3: 5-10 years of graduation; Group 4: more than 10 years of graduation. All professionals have been educated and trained to follow the same clinical protocol, but were unaware of the research objectives. A single evaluator accompanied the clinical treatments performed in 24 patients, totaling 274 single restorations in lithium disilicate, 158 in the anterior region and 116 in the posterior distributed region among the arches, 186 in the maxillae and 88 in the jaw. The thickness of the ceramic varied between 0.3 mm and 4.0 mm. Minor complications that occurred during the execution of the protocols, the etching and the light curing times and the type of cement were recorded. The restorations were cemented with different cements according to the thickness of ceramic, which: Rely X U200 (n = 120), Rely X Veneer (n = 95) and Variolink® Veneer (n = 58); totaling 91 full crowns, 137 laminated with preparation and 46 laminated with no prepare. Clinical assessments were performed after the installation of the restorations and at the controls of 30, 180 and 360 days after the cementing period. The parameters for evaluation were based on the modified USPHS criteria, adapted to the study. It was deemed unsuccessful when there was fracture or loosening of the restorations. Fractures were replicated and submitted to fractographic analysis. Results: The least number of failures were observed in Group 2 (1 debonding), the largest number in Group 1 (5 fractures) and highest... / FAPESP: 13/11938-0
7

Análise do comportamento da cor de restaurações cerâmicas sem metal avaliadas por diferentes métodos: estudo clínico prospectivo

Martini, Ana Paula [UNESP] 08 September 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-09-08. Added 1 bitstream(s) on 2016-02-05T18:34:24Z : No. of bitstreams: 1 000857916.pdf: 3361545 bytes, checksum: 05e359e822d36e17b2cdd2f6036cc13f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: O processo de interpretação da cor em restaurações cerâmicas delgadas pré e pós-tratamento é um desafio. Os métodos de avaliação dos resultados são diversos e a literatura não é clara em apontar o mais eficaz e eficiente. A questão é ainda mais relevante diante da variação do cimento resinoso utilizado. Proposição: Após variar o tipo de cimento resinoso utilizado, o objetivo deste estudo foi avaliar o comportamento da cor de restaurações cerâmicas em dentes com demanda estética, ao longo de 1 ano após o tratamento, com o auxílio de diferentes métodos de acompanhamento (espectrofotômetro, fotografias, vídeos e avaliação clínica) em um estudo clínico longitudinal e prospectivo. Materiais e Métodos: Foram selecionados 28 pacientes, perfazendo um total de 204 dentes restaurados (89 facetas laminadas, 57 coroas totais ou parciais e 58 lentes de contato). 76 restaurações foram cimentadas com Rely X veneer, 71 com Variolink veneer e 57 com Rely X U200. Foram realizadas mensurações de cor com espectrofotômetro, fotografias digitais e vídeos gravados no decorrer do tratamento e em controles periódicos (inicial, 30 dias, 180 dias e 1 ano após a cimentação). Grupos formados por observadores externos (pacientes, alunos de 1º e último ano de graduação, pós-graduandos e especialistas) avaliaram, aleatoriamente, as imagens obtidas inicialmente e ao final do tratamento, segundo perguntas sobre a satisfação ou não com o resultado estético do caso. Resultados: Os dados obtidos com o espectrofotômetro foram submetidos a testes estatísticos que revelaram diferença significativa apenas entre os tempos avaliados, contudo, para todos os tipos de restauração foi observada estabilidade de cor após, no máximo, 180 dias da cimentação. Não houve diferença estatística entre a satisfação dos diferentes grupos... / Introduction: The process of interpretation of color in thin ceramic restorations pre- and post-treatment is challenging. The evaluation methods of the results are diverse and literature is not clear in pointing out the most effective method. The question is even more relevant given the variation of the resin cement used. Purpose: After changing the type of resin cement used, the aim of this study was to evaluate the color behavior of ceramic restorations in teeth with aesthetic demand, over 1 year after treatment, with the help of different monitoring methods (spectrophotometer, photographs, videos and clinical assessment) in a longitudinal and prospective study. Materials and Methods: 28 patients were selected, for a total of 204 restored teeth (89 veneers, 57 crowns and 58 contact lenses). 76 restorations were cemented with Rely X veneer, 71 with Variolink veneer and 57 with Rely X U200. Color measurements were made with a spectrophotometer, digital photos and videos taken during treatment and periodic controls (initial, 30 days, 180 days and 1 year after cementation). Groups formed by outside observers (patients, students of 1st and last year of undergraduate, graduate students, and experts) evaluated, randomly, images obtained initially and after treatment, according to questions on satisfaction or not with the aesthetic outcome of the case. Results: The data obtained with the spectrophotometer were subjected to statistical tests which showed a significant difference only between the time periods; however, for all types of restoration, color stability was observed after a maximum of 180 days after cementation. There was no statistical difference between the satisfaction of different groups of outsiders observers with the aesthetic result of the cases for both the photos and for videos, although they videos have obtained the highest... / FAPESP: 12/14574-6
8

Avaliação da precisão de aquisição de dados nos Sistemas CAD/CAM: desadaptação marginal horizontal

Lopes, Leonardo Ferreira de Toledo Piza [UNESP] 23 February 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-23. Added 1 bitstream(s) on 2015-06-18T12:48:45Z : No. of bitstreams: 1 000831388.pdf: 562171 bytes, checksum: e080c07a229e0894fa23757920f53d4c (MD5) / Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal horizontal de infraestruturas de próteses fixas confeccionadas pelo sistema CAD-CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Foram confeccionados 50 corpos de prova divididos em 5 grupos, sendo eles, Convencional (Ni-Cr); GI: iTero; GII: CerecBluecam/fresadora industrial; GIII: 3S; GIV: CerecBluecam/ fresadora Sirona, todos com n=10. Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal horizontal, esta dividida em positiva para sobre-contorno e negativa para subcontorno. Resultados: A análise intra-examinador revelou não haver diferença estatística entre os dois períodos de análise (t pareado=0.019; p=0.985). Em relação as desadaptações de sobre-contorno (valores positivos) podemos analisar que o grupo controle (Convencional) apresentou estatisticamente (p <0.001) menores valores de desadaptação (82 μm) quando comparado com o grupo CAD/CAM (144 μm). Ao comparar o sistema intra/extra-oral pode-se observar que o grupo intra-oral (iTero) apresentou melhores resultados, sendo essa diferença estatisticamente significante (p <0.001) que o extra-oral (3s). Já avaliando a diferença entre um sistema aberto com um fechado foi observado que o sistema aberto apresentou estatisticamente menor desadaptação (p<0.001). Quando avaliou-se a quebra de um sistema fechado (Cerec BlueCam) para sua fresagem a nível industrial notou-se que há desvantagens em tal procedimento, pois houve estatisticamente maiores desadaptações no grupo da quebra do sistema (p<0.001). Em contra partida nenhuma diferença estatisticamente significante foi encontrada em todas as análises quando se comparou desadaptação por sub contorno. Significância: Avaliando a discrepância... / Objective: The aim of this study was to evaluate the horizontal marginal fit of frameworks produced by CAD/CAM systems with 3 different data acquisition. Material and Methods: We fabricated 50 frameworks divided into 5 groups, Conventional (Ni- Cr); GI: iTero; GII: CerecBluecam/industrial milling; GIII: 3S; GIV: CerecBluecam/Sirona, all with n = 10. We numbered the specimens and analyzed them randomly. Results: Intra-observer analisys indicated no statistically significant difference (paired t-test=0.019; p=0.985). In relation to the overextended horizontal marginal discrepancy (Positive Values) can analyze that the Control group (Conventional) had significantly (p < 0.001) minor discrepancy values (82 μm) when compared to the CAD / CAM group (144 μm). When comparing the systems intra/extra oral can be appreciated that the intra oral group (Itero) presented statistically best results when comparing(p < 0.001) that the extra oral ( 3s ). Evaluating the difference between the open system with closed was observed that the open system had statistically smaller misfit (p < 0.001). Evaluating the broke of a closed system (Cerec Bluecam) your industrial milling had statistically (p < 0.001) worse adaptation when compared to the laboratorial milling. About the under extended marginal discrepancy, in all analysis there was not found statistically significant difference. Significance: Assessing the horizontal marginal discrepancy was possible to note that in relation to the overextended the control group had statistically better results than the CAD/CAM systems, however the Cerec Bluecam system by sirona milling had better results than all CAD/CAM system and also the control group. There was no difference between the under extended misfit and all analysis
9

Avaliação da resistência à fratura de próteses fixas temporárias reforçadas por uma malha experimental

Almeida, Carolina Souza [UNESP] 09 February 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:25:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-09. Added 1 bitstream(s) on 2015-09-17T15:49:21Z : No. of bitstreams: 1 000843397.pdf: 1823033 bytes, checksum: c39021817bdac57624d83d1107f2cb19 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo no projeto foi avaliar a resistência à fratura de próteses fixas temporárias, com ou sem reforço posicionado em diferentes orientações (horizontal ou vertical), antes e após a termociclagem. Foram confeccionadas 72 próteses fixas temporárias de quatro elementos com resina bis-acrílica, divididas em três grandes grupos: sem reforço, com reforço horizontal e com reforço vertical. Cada grupo foi subdividido em dois, submetidos ou não a ciclagem térmica, totalizando seis subgrupos (n = 12). O reforço consiste em uma malha de nylon revestida por sílica (experimental). Os grupos ciclados receberam 1.000 ciclos térmicos. Todos os espécimes foram submetidos ao ensaio de resistência à fratura em uma máquina de ensaio universal (EMIC), com velocidade de 1,0 mm/min. No segundo experimento foi avaliada a influência do reforço em barras com dimensões de 25 X 10,5 X 3,3mm. As barras foram submetidas à termociclagem como descrito acima e ao ensaio de resistência à flexão 3 pontos, com velocidade de 5mm/min, com celular de carga de 10 KN. A análise estatística foi realizada através dos testes de Kruskal-Wallis Dunn (5%) e demonstrou que a incorporação e a disposição da malha influenciaram a resistência à fratura e a resistência à flexão da resina bis-acrílica foi aprimorada após a adição da malha / The aim of this study was to evaluate fracture resistance of temporary bridges as the influence of the addition of a modified nylon mesh in a bis-acrylic resin (Structur 2SC, VOCO, Cuxhaven, Germany). To the first step a temporary fixed prosthesis was made and were analyzed the presence or absence of the fiber and your position (horizontal or vertical). Some groups was subjected to thermal cycling of 1,000 to simulate a temporary fixed prosthesis with extended use period. All specimens were subjected to the test of fracture resistance in a universal testing machine (EMIC DL 1000, EMIC, Brazil), with a speed of 1.0 mm / min. For the second experiment, the test specimens was made in bar shaped (25 x 10.5 x 3.3 mm). The bars were analyzed concerning groups containing or not fibers. Some specimens were subjected to thermal cycling 1,000 cycles. All bars were submitted to the flexural strength by three points bending test in a universal testing machine at constant speed 5 mm/min with load cell of 10 kN. Statistical analysis was performed with Kruskal-Wallis and Dunn tests (5%) and demonstrated that the incorporation and arrangement of the mesh influence the fracture toughness and flexural strength of the bis-acrylic resin was improved afte adding the mesh
10

Determinação da resistência à flexão de ligas odontológicas, utilizadas em prótese parcial fixa e prótese sobre implante, soldadas por brasagem e a laser

Dinato, José Cícero [UNESP] 17 June 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-06-17Bitstream added on 2015-01-26T13:30:29Z : No. of bitstreams: 1 000126007.pdf: 2963801 bytes, checksum: 120f344cee7d077baf10fbd42aa2abf3 (MD5) / O objetivo deste trabalho foi determinar a resistência à flexão de sessenta corpos-de-prova cilíndricos, obtidos a partir de quatro ligas metálicas utilizadas em prótese parcial fixa e prótese sobre implante, disponíveis no mercado brasileiro (Co-span 13.5, Stabilor G, Deva 4 e Palliag M) medindo 25 mm de comprimento e 3 mm de diâmetro. Cinco corpos-de-prova de cada liga foram fundidos em monobloco, cinco soldados por brasagem e cinco a laser Nd-YAG, Dessa forma, obtiveram-se 15 corpos-de-prova para cada liga metálica, divididos em três grupos. No grupo I, os corpos-de-prova foram fundidos em monobloco; no grupo 2, soldados por brasagem; no grupo 3, soldados a laser. Após a conclusão dos corpos-de-prova, os três grupos foram submetidos a um ensaio de resistência flexural, em uma máquina de testes lnstron. O ensaio consistiu em submeter os corpos-de-prova a uma carga ao seu centro, com as suas extremidades apoiadas em dois cilindros separados por uma distância de 20 mm, de modo que sofressem a ação e reação da carga em apenas três pontos. A velocidade de aplicação da carga foi de 0,5 mm/min, com uma célula de carga de 500 kg. Os resultados numéricos obtidos foram submetidos à Análise de Variância e ao teste de Tukey, ao nível de 5% de probabilidade. Em vista dos resultados obtidos, conclui-se que o maior valor numérico da resistência flexural foi encontrado para a liga Co-span 13.5, seguido do Deva 4, para os grupos de soldagem a laser e monobloco. O material Palliag M apresentou valores estatisticamente semelhantes para os três grupos. A liga Stabilor G apresentou os melhores resultados no método por brasagem / The mechanic properties of brazed joints compared with castings performed in monoblocks have been exhaustingly evaluated. The use of laser in Dentistry opened a new and promising field to study this type of fusion. The purpose of this study was to determine the flexural resistance of four types of metal alloys used in fixed partial prosthodontics (Co-span 13.5, Stabilor G, Deva 4 and Palliag M). Fifteen test specimens with 3 mm diameter and 25mm length were obtained by casting for each alloy, and divided in three groups (monoblocks, brazing and laser welding), totaling sixty cylindrical specimens. The specimens were submitted to GLP/O2 torch welding and Nd-YAG laser welding performed with a specific laser equipment (Laser 2002, Dentaurum, Germany). The results were compared with tests performed in monoblocks of these same materials. To determine the flexural resistance, an universal testing machine (Instrom, model 4301), with a 500 Kg maximum capacity was used. The results were statistically analyzed using an ANOVA and Tuckey'.s test in a 5% degree of probability. The results showed that the highest numeric value of flexural resistance was found with the Co-Span alloy, followed by Deva 4, for both laser welding and monoblock groups. Palliag M showed statistically similar values for the laser welding, brazing and monoblock groups, whereas Stabilor G presented its highest values in brazing

Page generated in 0.0944 seconds