• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3203
  • 1896
  • 1442
  • 357
  • 329
  • 277
  • 164
  • 117
  • 92
  • 82
  • 50
  • 34
  • 31
  • 27
  • 26
  • Tagged with
  • 9599
  • 1073
  • 956
  • 754
  • 688
  • 633
  • 554
  • 542
  • 453
  • 448
  • 446
  • 443
  • 443
  • 418
  • 406
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modeling of Performance of Diode-Pumped Nd:YVO4 Laser Systems

Alimohammadian, Ehsan January 2014 (has links)
This thesis focuses on numerical study of a longitudinally pumped continuous wave (CW) Nd:YVO4 laser by high power VCSEL modules. Two VCSEL pump modules (6 W and 15 W) were compared. The performance of Nd:YVO4 crystal was found to be better than that of Nd:YAG crystal. Our numerical results indicate that VCSELs can serve as efficient pump sources for the end-pumped CW Nd:YVO4 lasers. Internal cavity loss (Li) is an important parameter in the modeling and optimization of laser’s performance. A new method for the calculation of the Li for longitudinally pumped lasers was introduced. This method can be conducted without making any changes to the CW laser cavity and it also can be performed faster compared to the widely used method called Findlay-Clay analysis. A successful experiment was conducted to find the Li based on both methods with good agreement between the two.
2

Standardisierbare Verfahren zur präzisen Charakterisierung des Absorptions-, Reflexions- und Transmissionsgrads optischer Komponenten

Willamowski, Uwe. January 1998 (has links) (PDF)
Hannover, Universiẗat, Diss., 1998.
3

Avaliação da viabilidade do uso do laser de diodo de média potência em periodontia: aspectos físicos e biológicos / Evaluation of the viability of the use of the medium power diode laser in Periodontics: physical and biological aspects

Mendonça, Carla Raquel Fontana 25 February 2003 (has links)
Os lasers de diodo de média potência aparecem como fonte alternativa aos lasers de Nd:YAG e Er:YAG para aplicações em Periodontia, tanto pelo aspecto econômico quanto pela facilidade de utilização, além dos bons resultados obtidos. Neste trabalho, avaliamos o uso do laser de diodo de média potência de até 1.2 W (Diodo FTC 1200, OPTO(r) São Carlos - Brasil) em aplicações periodontais. Para tanto, realizamos primeiramente um mapeamento térmico in vitro, em diferentes espessuras de tecido mole e parâmetros de potência. Este experimento nos revelou que as amostras com espessuras acima de 1.0 mm de tecido mole, não sofrem um aquecimento considerado crítico. Experimentos in vivo em tecido ósseo e mole de ratos também nos permitem afirmar que os parâmetros aqui testados são seguros para aplicações periodontais. O segundo passo deste estudo foi a análise microbiológica in vivo em bolsas periodontais induzidas em ratos. Os exames microbiológicos revelaram a presença de oito microrganismos distintos: Streptococcus beta-hemolitica, Prevotella sp, Fusobacterium sp, Pseudomonas sp, Escherichia coli, Proteus mirabilis, Enterobacter sp, Candida sp. Nossos resultados demonstram uma eficiência do laser de média potência na redução de patógenos periodontais. Especificamente para Prevotella sp e Fusobcterium sp, taxas de redução muito próximas de 100% foram obtidas. Estudos in vitro da ação bactericida do laser, utilizando cepas de Eikenella corrodens (ATCC 23834) e Bacteroides fragilis (ATCC 25285), comprovam sua eficiência. Para finalizar, realizamos a análise histológica dos animais submetidos à irradiação e do grupo controle. As lâminas histológicas confirmam os resultados obtidos pelos testes térmicos, pois nenhuma carbonização, ou alteração irreversível foi notada nos tecidos periodontais. No entanto, restos de alimentos foram evidenciados em algumas das análises histológicas dos ratos que já haviam recebido a irradiação. ) Este fato revela a importância de associar os benefícios proporcionados pela aplicação do laser ao tratamento mecânico de raspagem radicular / Diode lasers are modern devices still searching application in dentistry. As an alternative to be applied in periodontal treatment, diode laser can substitute the conventional solid state lasers like Nd:YAG and Er:YAG with tremendous advantage in cost and facility of use. This work has the aim to demonstrate the use of medium power diode laser in the treatment of periodontal disease. For this purpose a sequence of experiments were carried out using (Diodo FTC 1200, OPTO® São Carlos − Brasil). First we investigated the thermal effect on the adjacent tissue when the laser is used having the periodontal chamber as a target. Second, using an animal model we explored the efficiency of bacteria elimination when diode laser is used. Several types of bacterias as Streptococcus betahemolitica, Prevotella sp, Fusobacterium sp, Pseudomonas sp, Escherichia coli, Proteus mirabilis, Enterobacter sp, Candida sp were investigated. In a final observation, the histological exam was performed. A good preservation as well as evidence of strange bodies were observed. In conclusion we established that diode lasers are an appropriate tool for periodontal care
4

Development of hybrid UV VCSEL with organic active material and dielectric DBR mirrors for medical, sensoric and data storage applications

Todorov, Daniel Boychov. Unknown Date (has links)
Univ., Diss., 2008--Kassel.
5

Herstellung hochreflektierender AlGaN-AlN-DBR- und UV-VCSEL-Strukturen mittels plasmaunterstützter Molekularstrahlepitaxie

Fedler, Fritz. January 2003 (has links) (PDF)
Hannover, Universiẗat, Diss., 2003.
6

Avaliação da viabilidade do uso do laser de diodo de média potência em periodontia: aspectos físicos e biológicos / Evaluation of the viability of the use of the medium power diode laser in Periodontics: physical and biological aspects

Carla Raquel Fontana Mendonça 25 February 2003 (has links)
Os lasers de diodo de média potência aparecem como fonte alternativa aos lasers de Nd:YAG e Er:YAG para aplicações em Periodontia, tanto pelo aspecto econômico quanto pela facilidade de utilização, além dos bons resultados obtidos. Neste trabalho, avaliamos o uso do laser de diodo de média potência de até 1.2 W (Diodo FTC 1200, OPTO(r) São Carlos - Brasil) em aplicações periodontais. Para tanto, realizamos primeiramente um mapeamento térmico in vitro, em diferentes espessuras de tecido mole e parâmetros de potência. Este experimento nos revelou que as amostras com espessuras acima de 1.0 mm de tecido mole, não sofrem um aquecimento considerado crítico. Experimentos in vivo em tecido ósseo e mole de ratos também nos permitem afirmar que os parâmetros aqui testados são seguros para aplicações periodontais. O segundo passo deste estudo foi a análise microbiológica in vivo em bolsas periodontais induzidas em ratos. Os exames microbiológicos revelaram a presença de oito microrganismos distintos: Streptococcus beta-hemolitica, Prevotella sp, Fusobacterium sp, Pseudomonas sp, Escherichia coli, Proteus mirabilis, Enterobacter sp, Candida sp. Nossos resultados demonstram uma eficiência do laser de média potência na redução de patógenos periodontais. Especificamente para Prevotella sp e Fusobcterium sp, taxas de redução muito próximas de 100% foram obtidas. Estudos in vitro da ação bactericida do laser, utilizando cepas de Eikenella corrodens (ATCC 23834) e Bacteroides fragilis (ATCC 25285), comprovam sua eficiência. Para finalizar, realizamos a análise histológica dos animais submetidos à irradiação e do grupo controle. As lâminas histológicas confirmam os resultados obtidos pelos testes térmicos, pois nenhuma carbonização, ou alteração irreversível foi notada nos tecidos periodontais. No entanto, restos de alimentos foram evidenciados em algumas das análises histológicas dos ratos que já haviam recebido a irradiação. ) Este fato revela a importância de associar os benefícios proporcionados pela aplicação do laser ao tratamento mecânico de raspagem radicular / Diode lasers are modern devices still searching application in dentistry. As an alternative to be applied in periodontal treatment, diode laser can substitute the conventional solid state lasers like Nd:YAG and Er:YAG with tremendous advantage in cost and facility of use. This work has the aim to demonstrate the use of medium power diode laser in the treatment of periodontal disease. For this purpose a sequence of experiments were carried out using (Diodo FTC 1200, OPTO® São Carlos − Brasil). First we investigated the thermal effect on the adjacent tissue when the laser is used having the periodontal chamber as a target. Second, using an animal model we explored the efficiency of bacteria elimination when diode laser is used. Several types of bacterias as Streptococcus betahemolitica, Prevotella sp, Fusobacterium sp, Pseudomonas sp, Escherichia coli, Proteus mirabilis, Enterobacter sp, Candida sp were investigated. In a final observation, the histological exam was performed. A good preservation as well as evidence of strange bodies were observed. In conclusion we established that diode lasers are an appropriate tool for periodontal care
7

Etude des phénomènes de photodégradation et de polarisation dans les lasers organiques solides à cavité verticale externe / Photodegradation and polarization properties of vertical external surface-emitting organic laser

Leang, Tatiana 05 December 2014 (has links)
Les lasers organiques solides disposent d’atouts considérables par rapport aux autres types de laser : l’accordabilité en longueur d’onde dans le visible et la simplicité de fabrication. Ils restent néanmoins à la marge d’une commercialisation et le phénomène de photodégradation en est la principale cause. Le VECSOL pour Vertical External Cavity Surface-emitting Organic Laser est une structure de laser particulièrement bien adaptée pour l’étudier car elle permet un contrôle très simple de plusieurs paramètres pouvant entrer en jeu dans le phénomène de photodégradation. Ainsi lors de cette thèse, où nous avons cherché à comprendre quels sont les facteurs ayant une influence sur la durée de vie des lasers, l’intensité intracavité s’est par exemple révélée être un élément crucial : plus elle est grande, plus la durée du laser est grande. Par ailleurs, un suivi en temps réel de la forme du faisceau laser a montré que celle-ci, gaussienne au départ, devenait annulaire avant de s’éteindre traduisant la « mort » progressive des molécules sollicitées pendant le pompage.Une seconde partie de la thèse concerne la polarisation de la fluorescence des molécules organiques utilisées en laser solide. Nous avons montré que la concentration en colorant influençait grandement la dépolarisation de l’émission spontanée. Enfin, en fonctionnement laser, le faisceau reste polarisé rectilignement (comme la pompe) quel que soit la concentration en colorant. / Although organic solid-state dye lasers can provide wavelenght tunability in the whole visible spectrum and offers perpectives of low-cost compact lasers, they are still limited by several drawbacks, especially photodegradation. The geometry of a Vertical External Cavity Surface-emitting Organic Laser (VECSOL) enables organic lasers to reach high energies, excellent conversion efficiences and good beam quality, it also enables an external control on many parameters, a feature that we have udes here to study the photodegradation phenomenon as well as some polarization properties of organic solid-state lasers. In the first part of this thesis, we studied the lifetime of the laser upon varying several parameters (pump pulsewidth, repetition rate, output coupling, ...) and we found that the intracavity laser intensity, independently of the pump intensity, had a major on photodegradation rate. Moreover, we observed that the profile of the laser beam was also degrading with time : while it is Gaussian in the beginning it gradually shifts to an annular shape. In the second part, we investigated the polarization properties of VECSOLs, with a special emphasis on fluorescence properties of some typical dyes used in lasers. The crucial role played by resonant nonradiative energy transfers between dye molecules (HOMO-FRET) is evidenced and enables explaining the observed fluorescence depolarization, compared to the expected limiting fluorescence anisotropy. Energy transfers happen to play a negligible role above laser threshold, as the organic laser beam is shown to be linearly polarized in a wide range of experimental conditions when excitation occurs in the first singlet state.
8

Distributed feedback lasers and integrated laser arrays for wavelength-division multiplexing systems

Li, Jingsi 01 September 2015 (has links)
Distributed Feedback (DFB) lasers and integrated laser arrays are of great importance in Wavelength-Division Multiplexing (WDM) systems in fiber optic communication systems. High-performance, low-cost DFB lasers and laser arrays are highly desirable for applications in intra-datacenter transport and in local access networks. This dissertation is focused on the design, fabrication and achievement of high-performance, low-cost DFB Lasers and Integrated DFB Arrays for WDM Systems. It investigates the use of a novel sampled grating approach, called the equivalent phase shift method, to achieve integrated DFB laser arrays with single-mode lasing at uniformly-spaced and precisely-positioned wavelengths. First, laterally-Coupled DFB (LC-DFB) lasers with first-order sidewall gratings are realized, with gratings fabricated by optical interference lithography instead of e-beam. Then, LC-DFB lasers and LC-DFB laser arrays with sampled gratings and equivalent phase shifts are proposed, numerically analyzed and experimentally demonstrated. Each LC-DFB laser with an equivalent quarter-wave phase shift is shown to lase at the pre-specified wavelength in a single longitudinal mode, with good side-mode suppression ratio (SMSR) over a very wide range of injection currents. Integrated LC-DFB laser arrays with five uniformly-spaced wavelength channels are demonstrated, in close agreement with the design. For better performance, buried heterostructure (BH)-DFB laser and laser arrays are also demonstrated using the same sampled-grating technology. A 6-wavelenth laser array with a 300 μm cavity length and a 8-wavelength laser array with 250 μm cavity length are successively demonstrated, each showing precisely positioned lasing wavelengths, good SMSR, and uniformly good lasing characteristics under a wide range of operating currents and temperatures. Finally, it is demonstrated that the wavelength of a monolithic WDM laser array can be continuously tuned over a very wide wavelength range of nearly 40 nm. The proposed method offers a practical and cost-effective solution for the manufacture of high-performance, monolithic multi-wavelength DFB laser arrays as well as widely wavelength-tunable DFB lasers for integrated WDM systems.
9

Enhancement of high power pulsed laser ablation and biological hard tissue applications

Kang, Hyun Wook 28 August 2008 (has links)
Not available / text
10

Avaliação de Efeito Terapêutico do Laser de Baixa Potência de AsGaAl no Pós-operatório de Cirurgias de Terceiros Molares Inferiores

OLIVEIRA, F. L. M. 27 October 2017 (has links)
Made available in DSpace on 2018-03-22T16:00:35Z (GMT). No. of bitstreams: 1 tese_11488_Disserta__o de Mestrado Fl_via Lamanna 19-12-2017.pdf: 942851 bytes, checksum: 87408a19ebee4e4b909da91403b69fd5 (MD5) Previous issue date: 2017-10-27 / O objetivo desta pesquisa é avaliar a eficácia do Laser de Baixa Potência (LBP) de Arsenieto de Gálio e Alumínio (AsGaAl) na redução da dor e no restabelecimento da abertura de boca quando utilizado no pós-operatório de pacientes submetidos à remoção cirúrgica de terceiros molares inferiores. A amostra foi constituída por 22 pacientes entre 18 e 35 anos que fizeram parte tanto do grupo laser (G1) como do grupo controle (G2). Os indivíduos foram submetidos à cirurgia de exodontia dos elementos 38 e 48 em dias distintos e a aplicação do LBP e do placebo seguiu-se de acordo com o protocolo pré-estabelecido de aplicação imediata, 24 e 48 h após o procedimento cirúrgico no G1 e no G2, respectivamente. Os pacientes receberam, enquanto grupo laser, 4 J / cm² de densidade de energia do LBP de AsGaAl, comprimento de onda 808 nm, por períodos de 30 e 40 s intra e extraoral, respectivamente. A dor pós-operatória foi mensurada por meio de uma escala visual analógica (EVA) preenchida ao término da cirurgia (ao final do efeito da anestesia), 24 e 48 h após a cirurgia. A abertura bucal foi medida com paquímetro digital itutoyo®), previamente à cirurgia e 24 e 48 h após o procedimento cirúrgico. Para a análise estatística, utilizaram-se os testes não paramétricos de Friedman e de Wilcoxon na percepção da dor e os testes paramétricos ANOVA e t de Student na avaliação da abertura de boca. Os resultados obtidos identificaram diferença estatística significativa na percepção da dor, sendo esta menor em todos os períodos de tempo no grupo laser em relação ao grupo placebo, enquanto não foi verificada diferença estatística associada ao restabelecimento da abertura de boca. Portanto, concluímos que com a metodologia utilizada o laser AsGaAl, no protocolo terapêutico proposto, foi eficaz na redução da dor.

Page generated in 0.0706 seconds