• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fresamento corretivo de estruturas implanto-retidas : influencia na adaptação marginal e na confiabilidade do teste do parafuso unico / Multi-unit implant-supported frameworks corrective finishing : influence on the marginal misfit and reliability of single-screw test

Daroz, Luiz Gustavo Dias 24 February 2006 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T09:25:51Z (GMT). No. of bitstreams: 1 Daroz_LuizGustavoDias_M.pdf: 1050394 bytes, checksum: 25c85e7dd89cc812e9e871cdc982a3a1 (MD5) Previous issue date: 2006 / Resumo: A obtenção de uma peça perfeitamente adaptada aos componentes de retenção, mantendo a resistência estrutural a custo acessível é o principal objetivo durante a construção de uma prótese implanto-retida de múltiplos elementos. Além disto, julgar a qualidade da adaptação das peças depende da confiabilidade dos métodos existentes para determinação da passividade. O objetivo deste estudo foi determinar o desajuste marginal de infra-estruturas metálicas implanto-retidas tipo monobloco antes e após o fresamento corretivo destas peças empregando retificador manual. Avaliou-se ainda a hipótese de que os procedimentos de fresamento corretivo podem ter influência sobre a confiabilidade do teste do parafuso único utilizado para averiguação de adaptação marginal de peças múltiplas sobre implantes. Foram confeccionadas 40 infra-estruturas metálicas pela técnica do monobloco, sendo 20 fundidas em titânio comercialmente puro (Ti c.p.) e outras 20 fundidas em liga de cobalto-cromo (Cr-Cr). Para tal, utilizou-se matriz metálica simulando a disposição clínica de implantes osseointegrados na região interforames mentonianos contendo 5 análogos de pilares cônicos para peças múltiplas padrão Branemark (Micro-Unit - Conexão) e cilindros protéticos calcináveis compatíveis. As peças confeccionadas em Ti c.p. e em Co-Cr, foram subdivididas em 2 subgrupos (n=10) de acordo com a seqüência de retificação a que foram impostas: Seqüência A ¿ fresamento corretivo das bordas de adaptação dos cilindros protéticos seguido do fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar; e, Seqüência B ¿ fresamento corretivo da base de assentamento da cabeça do parafuso protético ao pilar seguido do fresamento corretivo das bordas de adaptação dos cilindros protéticos. A conduta forneceu um total de 4 grupos experimentais (Titânio A e B; Co-Cr A e B). As leituras de desajuste marginal, realizadas sobre a matriz metálica e com auxílio de um microscópio mensurador, foram baseadas na técnica do parafuso único e realizadas em cada estrutura antes e após cada etapa de retificação corretiva. As médias de desajuste marginal de cada estrutura foram calculadas e consideradas como uma unidade para a análise estatística. O teste de Friedman foi aplicado com nível de significância de 5% para avaliar o efeito dos diferentes passos de retificação sobre o desajuste marginal. Nos Grupos Ti A e B, assim como no Grupo Co-Cr A, não foi observada diferença significativa entre as condições experimentais (Grupo Ti A, p=0,9048; Grupo Ti B, p=0,273 e Grupo Co-Cr A, p=0,4966). Porém, diferenças estatisticamente significativas foram observadas no Grupo Co-Cr B, após a retificação corretiva das bordas dos cilindros fundidos (p=0,0017). Foi concluído que os procedimentos de fresamento corretivo não mostraram efeito significativo sobre a adaptação marginal das pecas de titânio. Contudo, em um grupo de peças fundidas em Co-Cr, a retificação das bordas dos cilindros mostrou efeito adverso sobre a passividade. Os procedimentos de fresamento corretivo parecem não apresentar influência significativa sobre a confiabilidade do teste do parafuso único, porém, devem ser realizados cuidadosamente, necessitando de aperfeiçoamentos para uma utilização segura / Abstract: The fabrication of a passively fitting framework over abutments and fixtures, maintaining its structural integrity and with a low costs, is the ultimate goal of the construction process of a multi-unit implant-support prosthesis. Furthermore, the accuracy and reliability of the passive fit determination methods have a crucial hole on framework misfit analysis. The objective was to evaluate the passive fit by the single-screw test method of cast commercially pure titanium (CP Ti) implantsupported frameworks after the corrective finishing of cast cylinders fitting borders and screw seats. The hypothesis tested was that finishing procedures could affect the single screw test measurements reliability. Were fabricated 40 frameworks by onepiece casting method, being 20 CP Ti frameworks and others 20 Co-Cr frameworks. A metallic index containing 05 Branemark-type multi-unit abutment analogs and respective calcinable cylinders were used to frameworks fabrication. The CP Ti and Co-Cr frames were assembled in 2 sub-groups (n=10) accordingly with the finishing sequence proposed: Group A - corrective finishing of cast cylinder borders followed by corrective finishing of cast cylinder screw seats - and Group B - corrective finishing of cast cylinder screw seats followed by corrective finishing of cast cylinder borders-. This conduct produce 4 experimental groups (CPTi A and B; Co-Cr A and B). The marginal gaps, assessed over the metallic matrix using a traveling microscope, were carried out before and after each corrective finishing step accordingly with one screw test protocol. The marginal misfit means of each framework was considered as a unit to statistical analyses. The Friedman¿s test was used with significance level set as 5% to analyze the effect of the different corrective finishing steps over frameworks passive fit. In the CPTi A and B Groups, and in the Co-Cr A Group, there was no significant differences between experimental conditions (Group CPTi A, p=0.9048; Group CPTi B, p=0.273 and Grupo Co-Cr A, p=0.4966). However, in the CPTi B Group, a significant difference was found after cast cylinder fitting borders corrective finishing (p=0.0015). It was concluded that the finishing process does not show any effect over Ti framewoks misfit values. However, to a group of Co-Cr frames, the fitting borders corrective finishing has a deleterious effect over passivity. The corrective finishing procedures seamed do not influence the single-screw test reliability, nevertheless, it should be used carefully and requires further improvements to guarantee a sever usage / Mestrado / Protese Dental / Mestre em Clínica Odontológica
2

Analise fotoelastica da distribuição de tensões induzidas por infra-estruturas implanto-suportadas obtidas pelas tecnicas do cilindro cimentado e soldado a laser / Stress distribution by implant-retained prosthesis comparing cylinders cemented and laser-welded.

Kleine, Alessandra 31 March 2006 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T10:58:33Z (GMT). No. of bitstreams: 1 Kleine_Alessandra_D.pdf: 1218745 bytes, checksum: c3583b924be9dcbd0a46d894fa1e9196 (MD5) Previous issue date: 2006 / Resumo: Este estudo avaliou a distribuição de tensões, através da análise fotoelástica de infra-estruturas de próteses fixas implanto-suportadas, confeccionadas pelas técnicas do cilindro cimentado ou soldado a laser. As estruturas foram obtidas a partir de uma matriz metálica com formas e dimensões similares a um arco mandibular. Foram confeccionadas 6 estruturas metálicas fundidas em titânio comercialmente puro (TritanÒ¿ Dentaurum - Germany), divididas em dois grupos: Grupo I: cilindros cimentados com cimento resinoso (Panavia FÒ Kuraray Co- Japan) e Grupo II: cilindros soldados a laser. Foram feitas mensurações com auxílio de um microscópio mensurador, com precisão de 0,0005 mm (STM Digital ¿ Olympus ¿ Japan), através do teste do parafuso único. Foi, então, escolhida a estrutura melhor adaptada, para cada um dos grupos, para a realização da análise fotoelástica, que foi realizada sobre um modelo confeccionado em resina fotoelástica (Aralditeâ GY279BR Huntsman - Araltec Produtos Químicos Ltda. ¿ Guarulhos - São Paulo), utilizando três seqüências de aperto dos parafusos (1/2/3/4/5, 5/4/3/2/1 e 3/2/4/1/5). Os resultados indicaram que maior quantidade de tensões foi observada na seqüência de aperto 1/2/3/4/5, para os grupos analisados. O grupo dos cilindros cimentados mostrou os melhores resultados, com menores valores de desadaptação (43,95 e 22,07mm) quando comparado ao grupo dos cilindros soldados a laser (198,8 e 60,17mm). A seqüência de aperto 3/2/4/1/5 mostrou menor quantidade de tensões para o grupo dos cilindros cimentados. A seqüência 5/4/3/2/1 apresentou melhores resultados para o grupo dos cilindros soldados a laser. O grupo dos cilindros cimentados apresentou melhores resultados, associado à seqüência 3/2/4/1/5 / Abstract: The aim of this study was to evaluate, by means of photoelastic analysis, the passive fit of fixed implant-supported prosthesis titanium frameworks using the cemented cylinder or laser welded cylinder techniques. Six frameworks welded in commercially pure titanium (TritanÒ-Dentaurum, Pforzhein-Germany) were made in a metallic master cast and divided in two groups. Group I: cylinders cemented with anaerobe resin (Panavia FÒ - Kuraray Co.) and Group II: cylinders laser-welded. The interfaces¿ evaluation and measurements were performed using a measurer microscope (STM Digital ¿ Olympus ¿ Japan) with 0.0005mm of precision. Thus, the ill-fit framework, for each group was chosen and evaluated by photoelastic analysis. The photoelastic model was made in photoelastic resin (Aralditeâ GY279BR Huntsman - Araltec Produtos Químicos Ltda. ¿ Guarulhos - Sao Paulo). Both groups were submitted to the photoelastic analysis, testing three screw-tightening sequences (1/2/3/4/5, 5/4/3/2/1 and 3/2/4/1/5). Results showed superior stress in 1/2/3/4/5 sequence of both groups. The cemented cylinder group showed better stress results (43.95 and 22.07mm) compared to the laser-welded cylinder group (198.8 and 60.17mm). The 3/2/4/1/5 sequence presented better stress for the cemented cylinder group. The 5/4/3/2/1 sequence showed better results for the laser-welded cylinder group. The cemented cylinder group presented the best results of stress analysis allied to the 3/2/4/1/5 sequence / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.1046 seconds