• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 5
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 23
  • 23
  • 11
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Distanční ochrana využívající digitální vstupní data / Distance Protection Design Using Digital Input Data

Wannous, Kinan Hasan Wafaa January 2020 (has links)
Standard IEC 61850-9-2 definuje přenos vzorkovaných měřených hodnot (sampled measured values, SMV) prostřednictvím sítě Ethernet a využití SMV získaných ze slučovacích jednotek nebo přístrojových transformátorů. Implementace IEC 61850-9-2 závisí na vlastnostech datového souboru, jakými jsou časová synchronizace, počet vzorků a časový interval. Dizertační práce je zaměřena na algoritmy chránění a analýzu vlivu standardu IEC61850-9-2LE na fyzická zařízení ochran s analogově/digitálními vstupními daty o proudu a napětí. S ohledem na narůstající míru interakce mezi fyzickými zařízeními a komunikačními prvky byl navržen test pro analýzu komunikace pro rozvodnu využívající konvenční metody (analogové vstupy) a metody digitální založené na standardu IEC 61850-9-2. Práce dále popisuje funkci slučovací jednotky využívající standard IEC61850-9-2LE. Navržená metoda definuje zdroj SMV a analyzuje přenos dat. V rámci práce byl za využití softwaru Matlab naprogramován algoritmus ochrany. Vytvořený model je schopen vyhodnotit vliv harmonického zkreslení na funkci digitálních ochran a vliv přesycení proudového transformátoru na distanční ochranu. V práci jsou zhodnoceny i možnosti zrychlení testování systémů chránění s využitím neuronové sítě. Závěrečná kapitola se zabývá aplikacemi v reálném čase, využívajícími data z rozvodny v blízkosti Vysokého učení technického v Brně. K přenosu dat z rozvodny do univerzitní laboratoře je zde využíváno SMV přenášených optickým kabelem o délce 16 km. Aplikace je vytvořena v programu Matlab a je schopna číst data z ethernetového portu, dekódovat je, převést z formátu ASCII do desítkové soustavy a poté vykreslit průběhy proudu a napětí. Mezi vlastnosti aplikace se řadí jednoduchost použití, schopnost implementace funkcí distanční ochrany, výpočet RMS hodnot proudu a napětí a harmonického zkreslení, harmonická analýza prostřednictvím rychlé Fourierovy transformace a výpočet impedance poruchové smyčky. Všechny výpočty běží v reálném čase a provedena je i citlivostní analýza modelu.
22

Analysis of high-voltage low-current DC/DC converters for electrohydrodynamic pumps

Axelsson, Sigge, Gartner, Jonas, Stafström, Axel January 2023 (has links)
Moving parts cause vibrations and tend to wear out. In applications where maintenance is complicated, solutions without moving parts are therefore advantageous. Electrohydrodynamic pumps are such a solution. Instead of mechanical propulsion, they use strong electric fields to induce movement in a dielectric cooling liquid. These pumps require very little power, but to generate sufficiently strong electric fields, they need to be fed with very high voltage.  This project explored various methods for designing DC/DC-converters which fulfil the demands of an electrohydrodynamic pump. This was done by altering and combining existing topologies that were deemed to be relevant. The main method for testing and evaluation was by simulating in LTspice. The project also briefly investigated methods of overcurrent protection. This was relevant because gas bubbles in the cooling fluid can cause electric arcs which damage the pumps. Three converter topologies were chosen for further evaluation. First, a conventional resonant Royer-based converter that has previously been used by APR Technologies which was altered by the inclusion of a feedback loop. Second, a high-frequency resonant Royer-based converter with a planar air-core transformer. Third, a transformerless converter with a switched boost converter IC. All circuits included a Cockroft-Walton voltage multiplier bridge. The two resonant Royer-based converters fulfilled all requirements except the one on efficiency, while the transformerless converter fulfilled all requirements except the one on cost, set by APR. The more expensive transformerless converter had a significantly higher efficiency and a wider range of acceptable input voltages. Furthermore three general conclusions were drawn. The first was that planar air-core transformers are not beneficial compared to conventional transformers in these type of applications. The second was that a discrete voltage regulator controlled by feedback from the output is more effective than using a voltage regulator without feedback, as it also eliminates temperature and load variations. The third conclusion was that to protect the circuits from overcurrent, a large series resistor is needed, which causes significantly lowered efficiency.
23

Návrh rekonstrukce stávající vstupní rozvodny a kabelové sítě 22 kV v areálu fakultní nemocnice / Projet of reconstruction of the 22 kV incoming substation and the cable network in the faculty hospital campus

Komárek, Filip January 2018 (has links)
This master's thesis deals with the area hospital distribution networkand one of the hospital's entry substation. The first part of this master's thesis deals with the project of the new cable network, her gradual revival without any power outages at the collection points. Futher, in this thesis is project of temporary transformer station for supplying power during the reconstruction of the HV switchboard. Subsequently, in this thesis is project of the new HV switchboard in one of the entry substation. new HV switchgear and a new HV substation were projected. Futher, in this thesis is proposed compensation of the whole area, including the HV network.

Page generated in 0.1391 seconds