• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Automatic overcurrent and leakage current sensing in multiple channel NMES systems

Otter, Malin, Jamal Pati, Bashar January 2023 (has links)
This report presents the development, implementation, and testing of a current monitor system that is specifically developed for testing a neuromuscular electrical stimulation system (NMES). The NMES system, developed by KTH and its academic and industrial partners Karolinska institute and Matrix Muscle Support, incorporates advanced features aimed at preventing cardiovascular diseases. The problem statement revolves around the necessity of developing a system capable of detecting any instances of overcurrent or leakage current in the neuromuscular electrical stimulation system. The purpose of this current monitoring system is to offer real-time monitoring of current levels within the electrical stimulation system. The project’s goal is to design and implement a comprehensive software and hardware solution that allows users to simultaneously monitor voltage levels across multiple channels and detect any abnormalities. The project was executed using a top-down approach. Each subtask is processed separately and finally tested to be verified and approved according to the expectations set. Test-driven development (TDD) methodology was employed to ensure the reliability and accuracy of the software and hardware implementation. The project has produced several significant results, the most important of which include the successful implementation of a real-time monitoring system for the multi-channel NMES system. A dedicated circuit board design has been prepared according to the specified requirements described in the report. The software interface has been designed to provide the user with real-time readings of voltage levels as well as visual identification of normal and abnormal values. The measurements carried out during all the tests gave clear answers to the set question, with the exception of some displacement (offset) which can be investigated more closely in future research. Furthermore, the reference images showed that the system was functioning in accordance with its original intended purpose. / Denna rapport presenterar utvecklingen, implementeringen och testningen av ett strömmätningssystem som är speciellt utvecklat för att testa ett neuromuskulärt elektriskt stimuleringssystem (NMES). NMES-systemet, utvecklat av KTH och dess akademiska och industriella partners Karolinska institutet och Matrix Muscle Support, innehåller avancerade funktioner som syftar till att förebygga hjärt-kärlsjukdomar. Problemformuleringen kretsar kring nödvändigheten av att utveckla ett system som kan detektera fall av överström eller läckström i det neuromuskulära elektriska stimuleringssystemet. Syftet med detta strömmätningssystem är att erbjuda realtidsövervakning av strömnivåer inom det elektriska stimuleringssystemet. Projektets mål är att designa och implementera en omfattande mjukvaru- och hårdvarulösning som tillåter användare att samtidigt övervaka spänningsnivåer över flera kanaler och upptäcka eventuella avvikelser. Projektet genomfördes med en top-down-metod. Varje deluppgift bearbetas separat och testas slutligen för att verifieras och godkännas enligt de förväntningar som satts. Testdriven utvecklingsmetod (TDD) användes för att säkerställa tillförlitligheten och noggrannheten hos implementeringen av mjukvara och hårdvara. Projektet har gett flera betydande resultat, av vilka de viktigaste inkluderar framgångsrik implementering av ett realtidsövervakningssystem för flerkanals NMES-systemet. En dedikerad kretskortsdesign har utarbetats enligt de specificerade kraven som beskrivs i rapporten. Mjukvarugränssnittet har utformats för att ge användaren realtidsavläsningar av spänningsnivåer samt visuell identifiering av normala och onormala värden. De mätningar som genomfördes under samtliga tester gav tydliga svar på frågeställningen, med undantag för viss förskjutning (offset) som kan undersökas närmare i framtida forskning. Vidare visade referensbilderna att systemet fungerade i enlighet med det ursprungliga syftet.

Page generated in 0.1076 seconds