• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Oxidace látek produkovaných sinicí Microcystis aeruginosa a její vliv na úpravu vody koagulací / Oxidation of compounds produced by cyanobacteria Microcystis aeruginosa and its impact on water treatment by coagulation

Štědrá, Karolína January 2021 (has links)
Due to eutrophication of aquatic environment, massive growth of algae and cyanobacteria occurs and the seasonal algal bloom is formed. Drinking water treatment plants have to deal with the increased amount of cells as well as organic compounds produced by algae and cyanobacteria (so-called AOM). Moreover, the presence of AOM causes a reduction in the efficiency of coagulation, which is an essential process in drinking water treatment. To increase coagulation efficiency, supportive methods, such as ozone oxidation, are added usually prior to coagulation. While many studies focused on the ozonation of algal and cyanobacterial cells, little is known about the effect of ozonation on AOM. This diploma thesis focused on the evaluation of the effect of ozonation in combination with coagulation on the removal of cellular organic compounds (COM) produced by cyanobacteria Microcystis aeruginosa. The effect of ozonation before or after coagulation on COM removal was investigated. The degradation of microcystins, which are naturally contained in the COM sample, was also monitored. Various ozone doses (1 - 10 mg/L) were tested at three pH values - 5, 7 and 9. Two coagulants were utilized - aluminium sulphate and ferric sulphate. Ozonation removed COM negligibly. However, eliminated microcystins, the degradation...
2

Estudo do comportamento do processo de ozonização como pós-tratamento de efluentes de sistema de tratamento anaeróbio de águas residuárias domiciliares / Experimental study of the performance of the ozonization after anaerobic treatment

Costa, Herlane dos Santos 21 February 2003 (has links)
Nessa pesquisa foi realizado um estudo experimental da potencialidade do emprego da ozonização após tratamento anaeróbio de efluentes, no que se refere a dosagem, tempo de contato, alcalinidade, aplicação conjunta com peróxido de hidrogênio, quantidade de ozônio consumida e oxidação de matéria orgânica. O estudo proposto foi executado por meio de: (a) estudos preliminares; (b) testes preliminares; (c) experimento I, empregando ozônio sem variação da alcalinidade afluente; (d) experimento II, empregando ozônio com variação da alcalinidade afluente; (e) experimento III, empregando ozônio combinado com peróxido de hidrogênio sem variação da alcalinidade afluente; (f) verificação da desinfecção; (g) análise crítica dos resultados. Fez-se comparação entre os parâmetros de análise, a dosagem de ozônio consumida e o tempo de contato e entre a qualidade do efluente ozonizado e os critérios de qualidade para reuso de efluentes, permitindo chegar as seguintes conclusões: (i) a maior parte do teor de ozônio consumido durante a ozonização é consumido nos primeiros 5 minutos; (ii) o consumo de ozônio pode ser melhor entendido analisando-se a variável dose instantânea aplicada de ozônio; (iii) o comportamento da transferência de ozônio é influenciado por três fatores: hidrodinâmica do reator, quantidade de ozônio, disponível para reagir e características do efluente; (iv) a variação no pH indica o grau de oxidação atingido no processo; (v) a presença de nitrato favorece a oxidação;(vi) a ozonização é um processo muito eficiente para desinfetar efluentes. A inativação de coliformes totais e fecais atingiu 7,51 e 6,98 Log, respectivamente; (vii) a massa de ozônio por tempo regula a taxa de remoção de DQO enquanto a dose média, a eficiência de remoção de DQO; (viii) Com o consumo de 32,46 +/- 8,19 mg/L de ozônio em 25 minutos de ozonização chegou-se a remoção média de DQO e Turbidez de 48,33 mais ou menos 2,90% e 89,22 +/- 0,35%, respectivamente; (ix) a adição de peróxido de hidrogênio melhorou significativamente a eficiência de remoção de DQO e de carbono. Sem adicionar o peróxido de hidrogênio, precisou-se de 25 minutos de ozonização para se atingir cerca de 25% de remoção de DQO; enquanto que, adicionando peróxido de hidrogênio na razão O3/H2O2 de aproximadamente 0,30, este tempo foi de apenas 10 minutos e a remoção de carbono total dobrou de valor; (x) o efluente ozonizado deve passar por tratamento adicional antes de ser lançado no corpo receptor ou ser reusado. / In this research an experimental study of the potentiality of employment of the ozonization was accomplished after anaerobic treatment, in what refers the dose, time of contact, alkalinity, application combined with hydrogen peroxide, amount of consumed ozone and oxidation of organic matter. The proposed study was executed by means of: (a) preliminary studies; (b) preliminary tests; (c) experiment I, using ozone without variation of the affluent alkalinity; (d) experiment II, using ozone with variation of the affluent alkalinity; (and) experiment III, using ozone combined with hydrogen peroxide without variation of the affluent alkalinity; (f) verification of the disinfection; (g) critical analysis of the results. The results were analyzed by means of graphs, it was make itself comparison among analysis parameters, transferred ozone dose and time of contact and among quality of ozonized effluent and quality criterion for effluent reuse. Permitting arrive the following conclusions: (i) the most of the content of consumed ozone during the ozonization is consumed in the first 5 minutes; (ii) the consumed ozone can be better understood analyzing itself the variable applied instant ozone dose; (iii) the behavior from the ozone transference is influenced by three factors: hydrodynamic of the reactor, quantity of ozone available to react and characteristics of the effluent; (iv) the change in pH shows the reached rank of oxidation in the process; (v) the presenceof nitrate favors to oxidation; (vi) the ozonization is a very efficient process to disinfect effluent. The inativation of total and fecal coliforms reached 7,51 and 6,98 Log, respectively; (vii) the mass of ozone controls the rate of COD removal while the medium dose controls the efficiency of COD removal; (viii) with the consumption of ozone of 32,46 +/- 8,19 mg/L in 25 minutes of ozonization, it arrived COD and turbidity medium removals of 48,33 +/- 2,90% and 89,22 +/- 0,35%, respectively; (ix) the addition of hydrogen peroxide improved significantly the efficiency of COD and carbon removal. Without adding hydrogen peroxide, it was needed 25 minutes of ozonization to reach about 25% of COD removal; while that, adding hydrogen peroxide in reason O3/H2O2of approximately 0,30, this time was only 10 minutes and total carbon removal double; (ix) the ozonized e to be submitted an additional treatment before of its discharge in the surface water or its reused.
3

Estudo do comportamento do processo de ozonização como pós-tratamento de efluentes de sistema de tratamento anaeróbio de águas residuárias domiciliares / Experimental study of the performance of the ozonization after anaerobic treatment

Herlane dos Santos Costa 21 February 2003 (has links)
Nessa pesquisa foi realizado um estudo experimental da potencialidade do emprego da ozonização após tratamento anaeróbio de efluentes, no que se refere a dosagem, tempo de contato, alcalinidade, aplicação conjunta com peróxido de hidrogênio, quantidade de ozônio consumida e oxidação de matéria orgânica. O estudo proposto foi executado por meio de: (a) estudos preliminares; (b) testes preliminares; (c) experimento I, empregando ozônio sem variação da alcalinidade afluente; (d) experimento II, empregando ozônio com variação da alcalinidade afluente; (e) experimento III, empregando ozônio combinado com peróxido de hidrogênio sem variação da alcalinidade afluente; (f) verificação da desinfecção; (g) análise crítica dos resultados. Fez-se comparação entre os parâmetros de análise, a dosagem de ozônio consumida e o tempo de contato e entre a qualidade do efluente ozonizado e os critérios de qualidade para reuso de efluentes, permitindo chegar as seguintes conclusões: (i) a maior parte do teor de ozônio consumido durante a ozonização é consumido nos primeiros 5 minutos; (ii) o consumo de ozônio pode ser melhor entendido analisando-se a variável dose instantânea aplicada de ozônio; (iii) o comportamento da transferência de ozônio é influenciado por três fatores: hidrodinâmica do reator, quantidade de ozônio, disponível para reagir e características do efluente; (iv) a variação no pH indica o grau de oxidação atingido no processo; (v) a presença de nitrato favorece a oxidação;(vi) a ozonização é um processo muito eficiente para desinfetar efluentes. A inativação de coliformes totais e fecais atingiu 7,51 e 6,98 Log, respectivamente; (vii) a massa de ozônio por tempo regula a taxa de remoção de DQO enquanto a dose média, a eficiência de remoção de DQO; (viii) Com o consumo de 32,46 +/- 8,19 mg/L de ozônio em 25 minutos de ozonização chegou-se a remoção média de DQO e Turbidez de 48,33 mais ou menos 2,90% e 89,22 +/- 0,35%, respectivamente; (ix) a adição de peróxido de hidrogênio melhorou significativamente a eficiência de remoção de DQO e de carbono. Sem adicionar o peróxido de hidrogênio, precisou-se de 25 minutos de ozonização para se atingir cerca de 25% de remoção de DQO; enquanto que, adicionando peróxido de hidrogênio na razão O3/H2O2 de aproximadamente 0,30, este tempo foi de apenas 10 minutos e a remoção de carbono total dobrou de valor; (x) o efluente ozonizado deve passar por tratamento adicional antes de ser lançado no corpo receptor ou ser reusado. / In this research an experimental study of the potentiality of employment of the ozonization was accomplished after anaerobic treatment, in what refers the dose, time of contact, alkalinity, application combined with hydrogen peroxide, amount of consumed ozone and oxidation of organic matter. The proposed study was executed by means of: (a) preliminary studies; (b) preliminary tests; (c) experiment I, using ozone without variation of the affluent alkalinity; (d) experiment II, using ozone with variation of the affluent alkalinity; (and) experiment III, using ozone combined with hydrogen peroxide without variation of the affluent alkalinity; (f) verification of the disinfection; (g) critical analysis of the results. The results were analyzed by means of graphs, it was make itself comparison among analysis parameters, transferred ozone dose and time of contact and among quality of ozonized effluent and quality criterion for effluent reuse. Permitting arrive the following conclusions: (i) the most of the content of consumed ozone during the ozonization is consumed in the first 5 minutes; (ii) the consumed ozone can be better understood analyzing itself the variable applied instant ozone dose; (iii) the behavior from the ozone transference is influenced by three factors: hydrodynamic of the reactor, quantity of ozone available to react and characteristics of the effluent; (iv) the change in pH shows the reached rank of oxidation in the process; (v) the presenceof nitrate favors to oxidation; (vi) the ozonization is a very efficient process to disinfect effluent. The inativation of total and fecal coliforms reached 7,51 and 6,98 Log, respectively; (vii) the mass of ozone controls the rate of COD removal while the medium dose controls the efficiency of COD removal; (viii) with the consumption of ozone of 32,46 +/- 8,19 mg/L in 25 minutes of ozonization, it arrived COD and turbidity medium removals of 48,33 +/- 2,90% and 89,22 +/- 0,35%, respectively; (ix) the addition of hydrogen peroxide improved significantly the efficiency of COD and carbon removal. Without adding hydrogen peroxide, it was needed 25 minutes of ozonization to reach about 25% of COD removal; while that, adding hydrogen peroxide in reason O3/H2O2of approximately 0,30, this time was only 10 minutes and total carbon removal double; (ix) the ozonized e to be submitted an additional treatment before of its discharge in the surface water or its reused.

Page generated in 0.1447 seconds