• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Hidroqu?mica do estu?rio do Rio Caravelas, Caravelas - BA

D?valos, Pablo Bezerra 15 March 2012 (has links)
Made available in DSpace on 2014-12-17T14:10:26Z (GMT). No. of bitstreams: 1 PabloBD_DISSERT.pdf: 2198407 bytes, checksum: 28806e44c2cf5816053edb8cade2279b (MD5) Previous issue date: 2012-03-15 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / Os estu?rios s?o corpos de ?gua importantes no transporte de nutrientes para a zona costeira,e em suas proximidadesse desenvolvematividades humanas que vem resultando em altera??es qu?micas dos ambientes costeiros. Inserido na ?rea de manguezal do Parque Nacional de Abrolhos, o estu?rio do rio Caravelas pode estar influenciando a zona costeira e os recifes internos do parque. Assim, com o objetivo de compreender a hidroqu?mica do estu?rio do rio Caravelas foram determinadas atemperatura, salinidade, pH, alcalinidade total (AT), estado de satura??o da aragonita (ΩArag) e calcita (ΩCalc), satura??o do oxig?nio dissolvido (Sat.OD), material em suspens?o (Seston), clorofila a (Cl-a), nitrog?nio oxidado (nitrato e nitrito) (NO), am?nia (NH3), s?licato(Si) e fosfato total (PT) e inorg?nico dissolvido (PID) no sistema estuarino do rio Caravelas, bem como dados da corrente (intensidade e dire??o). Foram realizadas amostragens temporais e longitudinais. As amostragens temporais foram realizadas em um ponto de amostragens durante um ciclo completo de mar?, meso-mar? semi-diurna, a intervalos de 1h. As amostragens longitudinais foram realizadas em tr?s esta??es ao longo do estu?rio realizadas durante as estofas de preamar e baixa-mar e cada ciclo de mar?. Ambas as amostragens foram realizadas nos ?pices dos regimes de mar? de siz?gia e de quadratura nas esta??es seca e chuvosa, agosto de 2007 e janeiro de 2008, respectivamente. Durante as amostragens temporais foram medidos dados de corrente para a determina??o dos fluxos e balan?os de propriedades. Al?m disso, foram determinadas as mesmas propriedades em um ponto na zona costeira (6 km al?m da boca do estu?rio) e no tribut?rio dulc?colo (rio do Cupido). Os valores na amostragem longitudinal foram de: Temperatura (?C)26,74?1,80, Salinidade 33,50 ?2,19, pH7,86 ?0,31, AT (mM) 2,38 ?0,30, ΩArag (%)3,02?1,87, ΩCalc (%)4,61?2,87,Sat.OD (%)78,11?11,69, PID (μM)0,23 ? 0,12, PT (μM)0,99?0,94, NO (μM)46,43?10,42, NH3 (μM)3,49?8,31, Si(μM)15,67?6,71, Cl-a (μg/L)2,94 ? 3,00 e Seston(mg/L)59,34?41,55. As massas calculadas no balan?o anual foram: Sal (Mg ano-1) 2,98 x 105, TA (Mmol ano-1) 0,70, CO3 2-(Mmol ano-1) 1,63 x 10-3, HCO3 -(Mmol ano-1) 1.91 x 10-2, PID (Mmol ano-1) 1,74, PT(Mmol ano-1) 28.21, NO (Mmol ano-1) 428,10, NH3(Mmol ano-1) 5,14, Si (Mmol ano-1) 1,23 e Seston (Gg ano-1) 2,04, os valores positivos indicam exporta??o de propriedade pelo sistema estuarino. As raz?es N/P indicam uma forte limita??o por P. As baixas concentra??es de nutrientes e clorofila-a indicam que o sistema ? oligotr?fico. No balan?o de propriedade, as exporta??es de todas as vari?veis apresentaram valores pouco representativos no cen?rio global dos ciclos biogeoqu?micos, mas o aporte de subst?ncias e a proximidade com os recifes internos do Parque Nacional de Abrolhos indicam uma prov?vel influ?ncia destas subst?ncias nestes recifes
2

Influ?ncia da intensidade de aera??o na forma??o do floco de lodo ativado e na efici?ncia de remo??o de mat?ria org?nica / Influence of the aeration intensity on the formation of activated sludge floc and efficiency of organic matter removal

Oliveira, Pedro Henrique da Silva 24 July 2014 (has links)
Made available in DSpace on 2014-12-17T15:01:35Z (GMT). No. of bitstreams: 1 PedroHSO_DISSERT.pdf: 2680953 bytes, checksum: 2a5742ac4e3d4679d06b09232988727f (MD5) Previous issue date: 2014-07-24 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / In wastewater treatment, activated sludge systems have been a technology widely applied as secondary treatment. During this step, which has a strong biological aspect, it is necessary to introduce oxygen supply for the maintenance of metabolic activity of the bacteria through the aerators. Aeration devices are responsible for most of the energy consumption in this stage. In this background, the influence of three aeration intensities (atmospheric air flow 3.5, 7.0 and 10.5 L.min-1) and the concentration of dissolved oxygen (DO) on the dimension of activated sludge flocs as well as on the efficiency of organic matter removal were assessed using a traditional activated sludge system which was fed with synthetic domestic wastewater. Samples were taken weekly from the three units that make up the system feed, aeration and storage tank in order to verify the Chemical Oxygen Demand (COD). It was established the process efficiency through a comparison between the initial and final COD. Besides the parameters already mentioned, this monitoring work on activated sludge batch system was also observed by Mixed Liquor Suspend Solids (MLSS), Volatile Suspend Solids (VSS), pH and temperature measures. The results have showed a maximum removal efficiency around 75% in the first aeration sequence and approximately 85% for the second and third one. For the first aeration, the DO concentration remained higher than 3.0 mg.L-1 and a diameter range from 10 to 60 μm was observed. In the second e third sequence, the DO concentration remained higher than 4.0 mg.L-1 with a diameter range of 10 until 200 μm. Although the sequence 1 and 2 have presented similar performances for organic matter removal, the sequence 2 promoted a regular floc size distribution and with lower values of Sludge Volumetric Index (SVI) meaning a better flocculating ability. In addition, the results reaffirmed what the literature has reported: higher DO concentrations produce flocs with greater dimensions / No tratamento de ?guas residu?rias, os sistemas de lodos ativados t?m sido uma tecnologia largamente aplicada como tratamento secund?rio. Durante essa etapa, a qual possui uma caracter?stica fortemente biol?gica, ? necess?rio o fornecimento de oxig?nio para a manuten??o da atividade metab?lica das bact?rias atrav?s de aeradores. Os dispositivos de aera??o s?o respons?veis pela maior parte do consumo de energia ao longo dessa fase. Nesse contexto, a influ?ncia de tr?s intensidades de aera??o (vaz?o de ar atmosf?rico de 3,5, 7,0 e 10, 5 L.min-1) e a concentra??o de oxig?nio dissolvido (OD) sobre a dimens?o de flocos de lodo ativado, e bem como sobre a efici?ncia de remo??o foram avaliadas utilizando um sistema tradicional de lodos ativados alimentado com efluente dom?stico sint?tico. Amostras foram retiradas semanalmente das tr?s unidades que compunham o sistema tanque de alimenta??o, de aera??o e de armazenamento para verificar a Demanda Qu?mica de Oxig?nio (DQO). A efici?ncia do processo foi estabelecida atrav?s da compara??o entre a DQO inicial e final. Al?m dos par?metros j? mencionados, este trabalho de monitoramento do sistema de lodos ativados de bancada foi observado tamb?m por meio de medi??es de S?lidos em Suspens?o Totais (SST) e Vol?teis (SSV), pH e temperatura. Os resultados mostraram uma efici?ncia m?xima de remo??o de quase 75% na primeira sequ?ncia de aera??o e aproximadamente 85% para a segunda e terceira sequ?ncias. Para a primeira aera??o, a concentra??o de OD manteve-se maior que 3,0 mg.L-1 e uma faixa de di?metro de 10 a 60 μm foi observada, enquanto que na segunda e terceira sequ?ncia, a concentra??o de OD permaneceu superior a 4,0 mg.L-1 com uma faixa de di?metro de 10 a 200 μm. Embora a sequ?ncia 2 e 3 tenham apresentado, ambas, desempenhos similares para remo??o de mat?ria org?nica, a sequ?ncia 3 promoveu uma distribui??o de tamanho de flocos mais regular e com baixos valores de ?ndices Volum?tricos do Lodo (IVL), configurando em uma melhor habilidade de sedimenta??o. Em adi??o, os resultados reafirmam o que literatura tem relatado, maiores concentra??es de OD produzem flocos com maiores dimens?es

Page generated in 0.0616 seconds