• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 12
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de oxigenador de membrana infantil em ovinos.

Finoti, Renata Geron 29 November 2011 (has links)
Made available in DSpace on 2016-01-26T12:51:32Z (GMT). No. of bitstreams: 1 renatageronfinoti_dissert.pdf: 2240331 bytes, checksum: e80f129b0db02c473d3a9c4f5162e004 (MD5) Previous issue date: 2011-11-29 / To analyze the security and efficacy of a new membrane oxygenator, the so-called OXM 1500. Methods: From May 2005 to September 2006, six sheep of Santa Inês breed (5 male and 1 female, respectively) were studied. The average body weight was 14.1 (±5) kg, body surface 0.6 (±0.2) m2 and a mean age 3.8 (±1.5) months. All of them were submitted to extracorporeal circulation (CEC) with evaluation at 10, 30, 60, 120, 180 and 240 minutes. The following values were obtained: values of oxygen transference (TTO2) and carbon dioxide transference (TTCO2), haemoglobin (HBS) and free haemoglobin (HBL), the score of platelets and of leucocytes, and heat transference rate. Results: TTO2 and TTCO2 were adequate. Lesion of the majority formed blood elements was insignificant; there no modifications in HBS, HBL levels; platelets and leucocytes decreased over time. Heat exchange was effective (p ≤ 0.05). Conclusions: The membrane OXM 1500 infant oxygenator, tested in sheep, showed adequate oxygenation capacity, CO2 removal capacity, and small alteration of haemoglobin and platelets without significant decrease of leucocytes, as expected. Heat exchanger connected to the oxygenator was efficient in temperature changes. / Analisar a segurança e a eficácia de um novo oxigenador de membrana denominado OXM -1500. Métodos: No período de maio de 2005 a setembro de 2006, foram estudados seis ovinos da raça Santa Inês, sendo cinco machos e uma fêmea, com peso corpóreo médio de 14,1 (±5) kg, superfície corpórea de 0,6 (±0,2) m2 e idade média de 3,8 (±1,5) meses. Todos foram submetidos à circulação extracorpórea (CEC) com avaliação nos tempos 10, 30, 60, 120, 180 e 240 minutos, obtendo-se os valores de taxa de transferência de oxigênio (TTO2) e de taxa de transferência de gás carbônico (TTCO2), hemoglobina sérica (HBS) e livre (HBL), plaquetometria, leucometria e taxa de transferência de calor. Resultados: Houve adequadas TTO2 e TTCO2. A lesão da maioria dos elementos figurados do sangue foi insignificante, sem alterações dos níveis de HBS, HBL, plaquetas e o número de leucócitos diminuíram com o tempo. A troca de calor foi efetiva (p ≤ 0,05). Conclusão: O oxigenador de membrana infantil OXM-1500, testado em ovinos, mostrou-se com capacidade adequada de oxigenação, remoção de gás carbônico e pequena alteração da hemoglobina e plaquetas, com diminuição do número de leucócitos de forma esperada. O trocador de calor acoplado ao oxigenador foi eficaz nas variações de temperatura.
12

Avaliação in vitro e ex vivo de oxigenador de membrana de baixa resistência para o uso ECMO sem auxílio de bomba.

Gandolfi, José Francisco 06 March 2006 (has links)
Made available in DSpace on 2016-01-26T12:51:54Z (GMT). No. of bitstreams: 1 josefranciscogandolfi_tese.pdf: 946147 bytes, checksum: 007d161afcdde952537f95c14f87bb0c (MD5) Previous issue date: 2006-03-06 / Introduction: Extracorporeal pulmonary assistance has been proposed as an invasive alternative to the conventional treatment when adequate oxygenation becomes impossible by mechanical ventilation. Extracorporeal membrane oxygenation (ECMO) attained using assisted circulation may cause hemolysis, coagulation disorders, an inflammatory response and complications inherent to a high-risk high-cost procedure. The objective of this work was to evaluate the efficacy, both in vitro and ex vivo, of a low-resistance oxygenator in ECMO without assisted circulation. Material and Method: Initially, different prototypes of the low-resistance membrane oxygenator were developed to test the influence of the of inlet and outlet conditions of the blood, the area, the quantity and placement of the fibers in the oxygenation process and the removal of carbon dioxide gas (CO2). In the in vitro tests when bovine blood was utilized, the mean flow, volume of blood needed to fill the oxygenator and for priming, oxygen saturation, carbon dioxide gas exchange and the pressure gradient were measured. For the ex vivo experiments, five Santa Inês sheep, weighing between 5 and 33 kg, were used. In each animal, variations in respect to the oxygen saturation, the PO2 and the PCO2 were studied in the systemic blood at the outlet of the oxygenator and of the venous blood using oxygen flow rates of 0.5L/min, 1.0 L/min and 1.5 L/min. Results: The oxygenator had an excellent mechanical performance, which was seen by the PO2, PCO2 and oxygen saturation of the blood at the outlet of the oxygenator. From the clinical point of view, the improvement in the PO2 and oxygen saturation and the reduction in PCO2 of the systemic arterial blood (femoral artery of the sheep), were evident in the five sheep. A tendency of better results was seen when the weight was less than 10kg. Translating these relationships in terms of blood flow and total volume, the best results appeared when the blood flow in the oxygenator/volume proportion was 20% or greater, establishing this cutoff point as the ideal flow necessary for the best performance of the oxygenator. Conclusion: The in vitro and ex vivo performance tests achieved with the low-resistance membrane oxygenator used in arteriovenous extracorporeal circulation without the assistance of a propulsion pump, proved that this device is capable of providing oxygen and removing carbon dioxide from the blood in sufficient quantities to maintain the tested parameters at acceptable limits when ventilation is prejudiced. / Introdução: A assistência pulmonar extracorpórea tem sido proposta como uma alternativa invasiva ao tratamento convencional, quando a oxigenação adequada torna-se impossível pelo uso de ventilação mecânica. A oxigenação extracorpórea por membrana (ECMO) realizada com auxílio circulatório pode produzir hemólise, distúrbios da coagulação, resposta inflamatória e complicações inerentes a um procedimento de alto risco e elevado custo. O objetivo deste trabalho foi avaliar a eficácia in vitro e ex vivo de um oxigenador de baixa resistência em ECMO sem auxílio circulatório. Material e Método: Inicialmente foram desenvolvidos diferentes protótipos do oxigenador de membrana de baixa resistência para testar a influência das condições de entrada e saída do sangue, área, quantidade e disposição das fibras no processo de oxigenação e remoção de gás carbônico (CO2). Nos testes in vitro, utilizando-se sangue bovino, foram avaliados fluxo médio, volume de sangue necessário para preencher o oxigenador ou priming, saturação de oxigênio e transferência de gás carbônico e o gradiente de pressão. Nos experimentos ex vivo foram utilizados cinco carneiros da raça Santa Inês, pesando entre 5 a 33 Kg. Em cada animal foram estudadas as variações com relação à saturação de O2, PO2 e PCO2, no sangue sistêmico, na saída do oxigenador e no sangue venoso com fluxos de oxigênio no oxigenador 0,5 L/min, 1,0 e 1,5 L/min. Resultados: O oxigenador demonstrou excelente desempenho mecânico, o que pode ser verificado pelos valores de PO2, PCO2 e SatO2 do sangue na saída do oxigenador. Do ponto de vista clínico, a melhora de PO2 e SO2 e a redução de PCO2 no sangue arterial sistêmico (artéria femoral do carneiro) foram evidentes nos cinco experimentos. Foi possível observar uma tendência para melhores resultados com pesos inferiores a 10,0 kg. Traduzindo-se essas relações em termos de fluxo sanguíneo e volemia total, os melhores resultados apareceram com proporção fluxo sangüíneo no oxigenador/volemia, de 20% ou maior, podendo-se estabelecer esse limite de corte, como fluxo ideal necessário para bom desempenho do oxigenador. Conclusão: Os testes de performance in vitro e desempenho ex vivo, realizados com o oxigenador de membrana de baixa resistência ao fluxo, para uso em circulação extracopórea arteriovenosa, sem o auxílio de bomba propulsora, mostraram resultados suficientes para concluir que tais dispositivos são capazes de fornecer Oxigênio e retirar gás Carbônico do sangue em quantidades suficientes para manter tais parâmetros em níveis aceitáveis, quando a ventilação está prejudicada.

Page generated in 0.032 seconds