• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 93
  • 1
  • Tagged with
  • 94
  • 94
  • 83
  • 81
  • 38
  • 30
  • 30
  • 29
  • 28
  • 28
  • 26
  • 25
  • 24
  • 24
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Pós-tratamento por lodos ativados de efluente de um reator anaeróbio compartimentado no tratamento de esgoto sanitário / Post-treatment by activated sludge of anaerobic baffled reactor effluent in the treatment of sanitary sewage

Coletti, Fábio José 15 December 1997 (has links)
Estudou-se nesta pesquisa o processo de lodos ativados para pós-tratamento do efluente proveniente de um reator anaeróbio compartimentado, que recebe esgoto sanitário. Isso se deu em vários ensaios em sistema descontínuo (\"batch\'\') para avaliar a biodegradabilidade dessa água residuária e em um ensaio em sistema contínuo com finalidade de melhorar a qualidade do efluente final e determinar os coeficientes cinéticos, os parâmetros a\' e b \', a taxa de utilização de oxigênio e o coeficiente &#945. Também realizaram-se ensaios hidrodinâmicos para verificação do tipo de reator utilizado. A pesquisa desenvolveu-se com base em uma célula de aeração, em escala de laboratório, composta por quatro câmaras (reatores) que possuíam tanque de aeração e decantador secundário justapostos, separados por uma cortina fixa. Não houve controle de temperatura nos dois sistemas utilizados. No ensaio em sistema contínuo quatro reatores foram operados simultaneamente com as respectivas idades do lodo de 5, 10, 15 e 20 dias durante 35 dias. O tempo de detenção hidráulico foi mantido próximo de 8 horas. Nesse ensaio os reatores quando se encontravam estabilizados dinamicamente, apresentaram remoção superior a 95% para DBO bruta, 90% para DBO filtrada, 87% para DQO bruta, 80% para DQO filtrada e 95% para SST. Mesmo não sendo realizado processo adicional para remoção de nutrientes, os reatores, após a estabilização dinâmica, apresentaram remoção de fosfato de até 28% e de nitrogênio amoniacal até níveis de não serem detectados pelos métodos de análises utilizados. Os ensaios hidrodinâmicos mostraram que os reatores são do tipo mistura completa. / In this work the activated sludge process for post-treatment of effluent anaerobic baffled reactor which receives sanitary sewage was studied. This was established during various experiments in batch system to evaluate the biodegradable of this wastewater and also in an experiment of continuous system aiming to improve the quality of the final effluent and to determine the kinetic coefficients, the a\' and b\' parameters, the oxygen uptake rate and the &#945 coefficient. Hydrodynamic tests to verify the type of reactor used in this research were also perfonned. The work was developed and based on an aeration cell bench-scale, composed of four chambers (reactors) which had an aeration tank and a secondary settling tank in the same chamber, separated by a fixed baffle. Temperature control was not used in both systems. In the experiment of continuous system, four reactors were simultaneously operated with sludge age of 5, 10, 15 and 20 days during 35 days. The hidraulic retention time was maintained at around 8 hours. When the reactors were dynamically stabilized, they showed an average removal superior to 95% for BOD (biochemical oxygen demand), 90% for filtrated BOD, 87% for COD (chemical oxygen demand), 80% for filtrated COD and 95% for TSS (total suspended solids). Without additional process of nutrient removal, after the dynamic stabilization the reactors presented up to 28% of total phosphate removal and ammonia nitrogen up to levels of not being detected by the analyses methods used. The hydrodynamic tests showed that the reactors are of the complete-mix type.
52

Flotação de alta taxa aplicada ao pós-tratamento de efluentes de reatores anaeróbios / High rate dissolved air flotation applying in the pos-treatment of anaerobics reactors effluents

Carvalho, Marcelo Eustáquio de 06 June 2003 (has links)
No presente trabalho foi utilizado um sistema de tratamento seqüencial de esgoto sanitário constituído de um reator anaeróbio de leito expandido (Ralex), com vazão de 10 m3/h, seguido de unidade piloto de flotação por ar dissolvido de alta taxa (FADAT) contendo placas paralelas em seu interior, com vazão de 5,58 m3/h. Para tempo de floculação de 20 min, foram estudados, como coagulantes, dosagens de cloreto férrico de 50 mg/L e 70 mg/L, taxas de aplicação superficial de 21 m/h e 42 m/h, gradiente médio de velocidade de floculação de 60 s-1, 80 s-1 e 100 s-1 e frações de recirculação de 8%, 13% e 18%. Dentre o conjunto de condições operacionais da unidade piloto FADAT estudada, foi considerado o mais vantajoso: taxa de aplicação superficial no flotador de 21 m/h, dosagem de cloreto férrico de 70 mg/L, gradiente médio de velocidade de floculação de 80 s-1 e 8,1 g de ar/m3 de efluente. Nessas condições foram obtidas as seguintes remoções: 84% de turbidez (residual entre 6,3 e 62 uT), 73% de DQO (residual entre 20 e 156 mgO2/L), 75% de fósforo (residual entre 0,5 e 1,9 mgP/L) e 67% de SST (residual entre 8 e 80 mg/L de SST). Os resultados demonstraram que o emprego da unidade FADAT como pós-tratamento de efluente de reator anaeróbio proporciona economia de energia, tendo em vista requererem de 75 a 50% da quantidade de ar exigida pelos sistemas de flotação convencional. / In this wok a sewage sequential treatment consisting of an expanded bed anaerobic reactor (EBAR) with 10 m3/h flow was used, folowed by a high rate DAF containing parallel plates in its interior, with 58 m3/h. For a floculation time of 20 minutes, were studied chemical additives, ferric chlorode dosages of 50 mg/L and 70 mg/L, overflow rates of 21 m/h and 42 m/h, velocity gradients of 60 s-1, 80 s-1 e 100 s-1 and reciculation rate between 8%, 13% and 18%. Among the group of operational conditions of the pilot unit studied high rate DAF the most advantageous was considered: overflow rates of 21 m/h in the high rate DAF of 21 m/h, ferric chlorode dosages of 70 mg/L, velocity gradients of 60 s-1, and air requirements of 8,1 g of air/m3 of wastewater. In those conditions they were obtained the following removals: 84% of turbidez (residual between 6,3 and 62 UT), 73% of DQO (residual\' between 20 and 156 mgO2/L), 75% of phosphorus (residual between 0,5 and 1,9 mgP/L) and 67% of SST (residual between 8 and 80 mg/L of SST). The results demonstrated that the employment of the unit high rate DAF as post-treatment of the anaerobic eflluents provides economy of energy, tends in view they request of 75 to 50% of the amount of air demanded by the systems of conventional flotation.
53

Utilização de serragem de couro do tipo wet blue como meio suporte de filtros percoladores para pós-tratamento de esgoto sanitário tratado em reator anaeróbio compartimentado / not available

Suassuna, Rita de Cascia Avelino 23 September 2004 (has links)
Nesta tese foi estudada a utilização da serragem de couro do tipo wet blue como meio suporte de filtros percoladores no pós-tratamento de esgoto sanitário. O desenvolvimento deu-se em três fases: na primeira fase foram realizadas a classificação e caracterização da serragem, bem como a sua preparação através de peneiramento, lavagens e secagem. Foram realizados dois tipos de lavagens: uma em batelada com solução alcalina de pH em torno de 9,0 e outra contínua com água corrente com pH em torno de 7,0. Na segunda fase foram utilizados quatro filtros percoladores com volume aproximado de 10 litros; dois foram preenchidos com serragem de couro bruta peneirada e os outros dois com serragem de couro peneirada, lavada e seca ao ar livre. Esses filtros operaram em série com quatro filtros de volume aproximado de 30 litros, preenchidos da mesma forma. Os quatro primeiros filtros receberam o efluente de um reator anaeróbio compartimentado e os demais receberam os efluentes dos primeiros. A terceira fase consistiu do uso apenas dos filtros percoladores de maiores volumes, os quais operaram aerados e com o afluente alcalinizado. Os conjuntos de filtros que operaram em série na segunda fase apresentaram eficiências de remoção de coliformes totais e fecais que variaram em torno de 94 e 92%, respectivamente. A eficiência de remoção de DBO5 total foi cerca de 80%. Na terceira fase, os filtros apresentaram eficiências de remoção de coliformes totais e fecais de cerca de 98 e 99%, respectivamente. Com relação à eficiência de remoção de DBO5, o valor encontrado foi de aproximadamente 80%. Nesta terceira fase foram encontradas excelentes reduções de NTK e de nitrogênio amoniacal com eficiências médias de remoção, para os dois parâmetros, de 83% antes da alcalinização e de 100% após a alcalinização. / This thesis studied the use of leather sawing (wet blue type) as packed bed of trickling filters in the wastewater post-treatment. The thesis was divided into three stages: as first stage the classification and characterization of the leather sawings were accomplished, as well as its conditioning through sieving, washing and drying. Two washing techniques were accomplished: a batch one with alkaline solution of pH around 9,0 and a continuous one with water of pH around 7,0. In the second stage four trickling filters were used with an approximated volume of 10 L; two were filled with sifted raw leather sawing and the two others with sifted, washed and open-air dryed leather sawing. Those filters operated in series with four other filters with an approximated volume of 30 L, filled in the same way. The 10 L filters received the efluent of an anaerobic baffled reactor and the others received the efluents of the first ones. The third stage consisted on the 30 L trickling filters alone, which were aerated and feeded with alkalinized influent. The group of filters that operated in series in the second stage presented total and fecal coliform removal efficiencies that varied around 94 and 92%, respectively. The efficiency of total BOD5 removal was around 80%. In the third stage filters presented total and fecal coliformes removal efficiencies around 98 and 99%, respectively. About BOD5 removal efficiency, it was found a value of approximately 80%. In this stage it was achieved excellent KTN and ammoniacal nitrogen removals with average removal efficiencies of 83% before alkalinization and 100% after alkalinization.
54

ALIANÇA TERAPÊUTICA E DEPRESSÃO PÓS-PARTO: SEGUIMENTO AOS SEIS MESES PÓS PSICOTERAPIA COGNITIVA BREVE

Muenzer, Renata Mendes 18 December 2007 (has links)
Made available in DSpace on 2016-03-22T17:26:02Z (GMT). No. of bitstreams: 1 Renata_Muenzer.pdf: 274027 bytes, checksum: 96793540f286000aea6639859fe1c001 (MD5) Previous issue date: 2007-12-18 / Purpose: To verify if therapeutic alliance in the end of the treatment is able to predict the effectiveness of cognitive psychotherapy approach within a six months period after the end of intervention with depressive postpartum mothers. Method: Clinical trial proceeding study with depressive postpartum women. This study included 60 women that were evaluated in the last session with the Beck Depression Inventory (BDI) and the Working Alliance Inventory (WAI). The therapists have also answered to the WAI Inventory. After six months the BDI was re-applied to the clients. Results: The therapeutic alliance when evaluated by the client was not able to predict the treatment effectiveness six months after the therapy (WAI total; p=0,71). On the contrary, when evaluated by the therapist, an elevated alliance was able to predict a worsening on depressive symptoms of the mothers in the period after the treatment (WAI total; p=0,003). Conclusion: The therapist´s perception of an elevated alliance with his client was able to predict a worsening on depressive symptoms of the mothers six months after intervention / Objetivo: Verificar se aliança terapêutica ao final do tratamento é capaz de predizer a efetividade da psicoterapia de fundamentação cognitivista após seis meses do término da intervenção em mulheres deprimidas no pós-parto. Método: Estudo de seguimento de ensaio clínico em mulheres deprimidas no pós-parto. No ensaio foram incluídas 60 mulheres que foram avaliadas na última sessão psicoterápica pelo Beck Depression Inventory (BDI) e Working Alliance Inventory (WAI). Os terapeutas também responderam ao WAI neste momento. Após seis meses o BDI foi re-aplicado às clientes. Resultados: A aliança terapêutica quando avaliada pelo cliente não foi preditora da efetividade do tratamento após seis meses pós-psicoterapia (WAI total; p=0,71). Quando avaliada pelo terapeuta, a aliança alta foi preditora de uma piora dos sintomas depressivos das mães no período pós-tratamento (WAI total; p=0,003). Conclusão: A percepção do terapeuta de uma elevada aliança com seu cliente foi capaz de predizer uma piora da sintomatologia depressiva das mães após seis meses da intervenção
55

Biofiltro aerado submerso aplicado ao pós-tratamento de efluente de reator UASB, sob condições hidráulicas desfavoráveis: estudo em escala real / Submerged aerated biofilter used for post-treatment of the effluent of an UASB reactor, under unfavorable hydraulic conditions: full-scale study

Godoy, Thais Gorga de 14 September 2007 (has links)
Esta pesquisa avaliou a eficiência do biofiltro aerado submerso empregado no pós-tratamento do efluente do reator anaeróbio de manta de lodo (UASB), em escala real, localizado na ETE Água Vermelha em São Carlos, SP, sob condições hidráulicas desfavoráveis. Estudou-se a remoção de matéria orgânica e de sólidos, a possibilidade de remoção de nitrogênio e fósforo e também as características da biomassa aderida ao meio suporte. O estudo foi desenvolvido em duas fases, uma sem a adição de inóculo (fase I) e outra com inoculação (fase II). Na fase I foi aplicada vazão de 380 m³/dia, cargas orgânicas volumétricas (COV) de 3kgDQO/m³.dia com carga hidráulica (CH) de 8 m³/m².dia e tempo de detenção hidráulica (TDH) de 170 minutos. Nesta fase o biofiltro alcançou eficiências médias de 40% na remoção de matéria orgânica (DQO) e de 35% para os SST. Na segunda fase foram aplicadas vazões de 500 m³/dia, COV de 4 kg DQO/ m³.dia com CH de 11 m³/ m².dia e TDH de 130 minutos. O BAS apresentou eficiências médias de remoção de DQO, \'COT IND.F\' e SST de 36%, 60% e 30%, respectivamente, para a fase II. A conversão de nitrito a nitrato foi considerada desprezível, podendo ser atribuída ao alto valor de DQO afluente ao BAS, à ocorrência de nitrificação e desnitrificação no mesmo biofilme e à distribuição ineficiente de ar no interior do reator. O biofiltro não apresentou bons resultados quanto à remoção de fósforo durante a pesquisa. O estudo permitiu concluir que o BAS apresentou um desempenho satisfatório como unidade de pós-tratamento de reator UASB na fase de partida, mesmo sendo submetido a altas cargas hidráulicas e orgânicas. Constatou-se, portanto, que o emprego do biofiltro aerado submerso apresenta-se como uma alternativa vantajosa para o pós-tratamento do efluente de reatores anaeróbios, produzindo um efluente de excelente qualidade. / This research evaluated the efficiency of a full scale submerged aerated biofilter (SAB) used for post-treatment of the effluent of an upflow anaerobic sludge blanket (UASB) reactor, located in the wastewater treatment plant Água Vermelha (São Carlos, SP, Brazil), under unfavorable hydraulic conditions. The removal of organic matter and solids, the possibility of removal of nitrogen and phosphorus and also the characterization of biomass attached to the packing media were studied. This study vas developed in two phases, one without reactor seeding (phase I), and another when the reactor was seeded (phase II). At phase I, a flow rate of 380 m³/d and a volumetric loading rate of 3 kgCOD/m³.d with hydraulic load (HL) of 8 m³/m².d were applied, with 170 minutes of hydraulic retention time (HRT). In this phase the biofilter reached average efficiencies of 40% in organic matter removal (COD) and 35% for TSS. Already in phase II, a flow rate of 500 m³/d, a volumetric loading rate of 4kgCOD/m³.d with HL of 11 m³/ m².dia were applied, with 130 minutes of HRT. The SAB allowed average removal efficiencies of COD, \'TOC IND.F\' and TSS of 36%, 60% and 30%, respectively, for phase II. The conversion of nitrite to nitrate was considered worthless, likely attributed to the high value of affluent COD to the SAB, the occurrence of nitrification and denitrification in the same biofilm and the inefficient air distribution in the interior of the reactor. The biofilter did not present good results in phosphorus removal. This study allowed to conclude that the aerated submerged biological filter presented a satisfactory performance as a post-treatment unit of an UASB reactor during the start-up phase, being submitted to high hydraulic and organic loads. It was found that the employment of the submerged aerated biofilter is an advantageous alternative as anaerobic effluent post-treatment, producing excellent quality effluent.
56

Microbiologia e cinética de sistema de lodos ativados como pós-tratamento de efluente de reator anaeróbio de leito expandido / Microbiology and kinetic of activated sludge system as post treatment of expanded bed anaerobic reactor

Mendonça, Luciana Coêlho 22 November 2002 (has links)
Os principais objetivos deste trabalho foram analisar o desempenho de sistema combinado (escala piloto), constituído por reator anaeróbio de leito expandido (Ralex) seguido por sistema de lodos ativados, utilizado no tratamento de esgoto sanitário, correlacionar as características da microbiota do sistema de lodos ativados com os resultados físico-químicos e determinar a cinética de consumo de substrato no sistema de lodos ativados. O desempenho do sistema combinado quanto à remoção de DQO total e DQO filtrada foi de 82% e 80%, respectivamente. No sistema combinado, a remoção de nitrogênio total foi de 65% e a remoção de fósforo foi de 35%. A população de protozoários foi bem diversificada, sendo condizente com as características operacionais do sistema de lodos ativados. Arqueas metanogênicas foram capazes de sobreviver no tanque de aeração, porém em número reduzido. O modelo cinético que melhor representou a degradação de DQO filtrada, no sistema de lodos ativados, foi o de primeira ordem com residual. A constante aparente específica média foi de 0,05L/gSSV.dia. Nas condições estudadas, não ficou evidenciado o efeito da temperatura na cinética, provavelmente devido à resistência de transferência de massa. / The major objectives of this study were: (i) to evaluate the performance of a combined system (pilot scale) treating wastewater, composed by an expanded bed anaerobic reactor and an activated sludge system; (ii) to correlate microorganisms characteristics of the activated sludge system with the physical-chemical results; and (iii) to determinate the substrate consumption kinetics of the activated sludge system. The performance of the combined system in terms of total and filtrated COD was 82% and 80% respectively. Total nitrogen removal was 65% and total phosphorous removal was 35%, in the combined system. Protozoa populations were well diversified, according to operational characteristics of activated sludge. Methanogenics archeas survived into aeration tank, but in a reduced number. First order with residual kinetic model represented the filtered COD degradation, in the activated sludge system. The mean apparent specific constant was 0,05L/gVSS.day. In this study, the effect of temperature on kinetics was not evident, probably due to mass transfer resistance.
57

Flotação aplicada ao pós-tratamento do efluente de reator anaeróbio de leito expandido tratando esgoto sanitário / Flotation applied to the post-treatment of effluents from expanded bed anaerobic reactor treating domestic sewage

Penetra, Rogério Gomes 23 May 2003 (has links)
Este trabalho apresenta e discute os resultados de um estudo amplo e aprofundado sobre os principais parâmetros operacionais da flotação por ar dissolvido, utilizada no pós-tratamento de efluentes de um reator anaeróbio de leito expandido (RALEx), tratando 10 m3/hora de esgoto sanitário. Foram realizados preliminarmente ensaios utilizando o flotateste, unidade de flotação em escala de laboratório, para identificar as melhores dosagens de coagulante (cloreto férrico), o polímero mais adequado, dentre os 26 testados, e sua respectiva dosagem, o pH de coagulação adequado, o tempo (Tf) e o gradiente de velocidade (Gf) de floculação mais apropriados e a quantidade de ar (S*) requerida. Para obtenção das condições operacionais adequadas para a unidade piloto de flotação, os valores de Tf e de Gf foram variados de zero a 24 minutos e de 40 a 100 s-1, respectivamente. As concentrações de cloreto férrico e de polímero sintético variaram de 15 a 92 mg/L e de 0,25 a 7,0 mg/L, respectivamente. S* variou de 2.85 a 28.5 gramas de ar por metro cúbico de efluente e a taxa de aplicação superficial na unidade de flotação abrangeu de 180 a 250 m3/m2/d. O desempenho da flotação durante a partida do reator anaeróbio também foi investigado. O uso de 50 mg/L de cloreto férrico, de Tf igual a 20 min e Gf de 80 s-1, de S* de 19,7 g de ar por m3 de efluente e taxa de 180 m3/m2/d produziu excelentes resultados nos ensaios com a instalação piloto de flotação, com elevadas remoções de carga de DQO (80,6%), de fósforo total (90,1%) e de sólidos suspensos totais (92,1%) e com turbidez entre 1,6 e 15,4 uT e residuais de ferro de 0,5 mg/L, com remoção estimada, na forma de lodo, de 77 gramas de SST por m3 de efluente tratado. Nestas mesmas condições, no sistema RALEx+FAD, foram observadas remoções globais de 91,6% de carga de DQO, de 90,1% de carga de fósforo e de 96,6% de carga de SST. O emprego da flotação por ar dissolvido (FAD) mostrou-se alternativa bastante atraente para o pós-tratamento de efluentes de reatores anaeróbios. Se a coagulação estiver bem ajustada, o sistema composto de reator anaeróbio seguido de unidade de flotação consegue alcançar excelente remoção de matéria orgânica, redução significativa da concentração de fósforo e de sólidos suspensos, além de precipitação dos sulfetos dissolvidos, gerados no reator anaeróbio. Bons resultados foram alcançados mesmo quando o reator RALEx produziu efluentes de baixa qualidade durante seu período de partida. Nesse período, o sistema de flotação atuou como barreira eficaz, evitando a emissão de efluente de baixa qualidade do sistema. / This research work presents ad discusses the results of a wide and deep study on the main operational parameters of DAF while used for the post-treatment of effluents from a pilot expanded-bed anaerobic (RALEx) reactor. The system received 10 m3 per hour of domestic sewage. Bench-scale assays in flota-test units were first carried out to achieve the best dosage of coagulants (ferric chloride), the best polymer and respective dosages, the adjusted pH for coagulation, the flocculation time (Tf), the proper velocity gradient (Gf) and the amont of air (S*) required. In order to obtain the proper operational conditions in the pilot DAF plant, Tf and Gf were made to vary from zero to 24 minutes and from 40 to 100 s-1, respectively. The chemicals ferric chloride and synthetic polymer concentrations ranged from 15 to 92 mg/L and 0.25 to 7.0 mg/L, repectively. S* varied from 2.85 to 28.5 grams of air per cubic meter of wastewater and the applied flotation rates ranged from 180 to 250 m3.m-2.d-1. DAF performance was also investigated during RALEx start-up period. At the DAF operational conditions of 50 mgFeCl3.l-1, Tf of 15 min, Gf of 80 s-1, S* of 19.7 g of air per m3 of wastewater and the applied loading rate of 180 m3.m-2.d-1, the removal efficiencies attained 80.6% for COD, 90.1% for phosphorus, 92.1% for suspended solids, producing effluents with turbidity ranged from 1.6 to 15.4 NTU, residual Fe of 0.5 mg/L, removing 77 grams of SST per cubic meter of wastewater. At the same conditions, the system RALEx-DAF presented global efficiencies of 91.6% for COD, 90.1% for phosphorus and 96.6% for suspended solids. The utilization of dissolved-air flotation (DAF) constitutes an attractive alternative for the post-treatment of anaerobic reactor´s effluents. If coagulation is well adjusted, such system composed of anaerobic reactor followed by DAF can achieve excellent organic matter removal, expressive solids and phosphorus reduction and precipitation of dissolved sulfide generated in the anaerobic unit. Good results were also obtained even when RALEx produced low quality effluents during start-up period. In such period, the DAF unit functioned as an efficient barrier for avoiding the emission of low quality system effluent.
58

Pós-tratamento físico-químico por flotação de efluentes de reatores anaeróbios de manta de lodo (UASB) / Physical-chemical post-treatment by flotation of effluents from upflow anaerobic sludge blanket (UASB)

Penetra, Rogério Gomes 29 May 1998 (has links)
O emprego da flotação por ar dissolvido (FAD) para o pós-tratamento de efluentes de reatores anaeróbios aparenta ser atraente considerando algumas características desse processo físico-químico. A FAD é reconhecidamente um processo de alta taxa, particularmente eficiente na remoção de material particulado em suspensão e de flocos produzidos pela coagulação química de águas residuárias. Além disso, há produção de lodo espesso e provavelmente arraste de parcela de gases e de compostos voláteis, presentes nos efluentes anaeróbios. Entretanto, a concepção de sistemas de FAD deve ser precedida por ensaios em unidades de flotação em escala de laboratório, permitindo a determinação dos principais parâmetros do processo. Neste trabalho, são apresentados e discutidos os resultados obtidos em laboratório e em instalação piloto de flotação com escoamento contínuo recebendo efluente de reator anaeróbio de manta de lodo (UASB), com 18 m3 de volume, tratando esgoto sanitário. Os ensaios em unidade em escala de laboratório foram realizados utilizando diferentes dosagens de cloreto férrico (entre 30 e 110 mg/L) ou de polímero catiônico (entre 1,0 e 16,0 mg/L), atuando como coagulantes. Além disso, foram estudadas as condições de floculação (tempo de 15 e de 25 min, e gradiente médio de velocidade de floculação entre 30 e 100 s-1) e diferentes valores de quantidade de ar fornecido ao processo (S*, entre 4,7 e 28,5 g de ar por m3 de efluente). Com a instalação piloto de FAD foram realizados apenas ensaios preliminares variando-se a taxa de aplicação superficial (140 e 210 m3/m2/d) para diferentes valores de S* (14,8 a 29,5 g de ar por m3 de efluente). Com o emprego de dosagem de 65 mg/L de cloreto férrico, de tempo de 15 min e gradiente médio de velocidade de floculação de 80 s-1 e de 19 g de ar por m3 de efluente, foram observados excelentes resultados em laboratório, com elevadas remoções de DQO (89%), de fosfato total (96%), de sólidos suspensos totais (96%), de turbidez (98%), de cor aparente (91%), de sulfetos (não detectado) e NTK (47%). Considerando o sistema UASB e FAD, nos testes em laboratório, foram observadas remoções globais de 97,7% de DQO, de 98,0% de fosfato total, de 98,9% de SST, de 99,5% de turbidez, de 97,8% de cor aparente e de 59,0% de NTK. Nos ensaios com a instalação piloto de FAD, o sistema apresentou remoções de 93,6% de DQO, de 87,1% de SST, de 90% de sulfetos e de 30% de NTK. / The utilization of dissolved-air flotation (DAF) for the post-treatment of effluents from anaerobic reactors seems to be attractive considering some characteristics features of such a physical-chemical process. DAF is known to be a high-rate process particularly efficient for the removal of suspended particles and flocs produced by the chemical coagulation of wastewaters. Moreover, it produces a thick sludge and probably promotes the stripping of gases and volatile compounds present in anaerobic effluents. However, the design of DAF systems has to be preceeded by assays in lab-scale units permiting to establish the main process parameters. The results obtained from a lab-scale unit receiving effluent of a 18 m3 upflow anaerobic sludge blanket (UASB) reactor treating domestic sewage are presented and discussed. The assays were performed firstly in a lab-scale unit, using ferric chloride (from 30 to 110 mg/L) or cationic polymer (from 1.0 to 16.0 mg/L) as coagulant under different concentrations. In order to obtain proper conditions for flocculation time (t) was fixed at 15 and 25 min and velocity gradient (G) was ranged form 30 to 100 s-1. The required quantity of air (S*) was ranged from 4.7 to 28.5 g of air per m3 of wastewater. Using a FAD pilot plant, only preliminary assays were performed, using two surface load rate values (140 e 210 m3/m2/d) and different S* values (from 14.8 to 29.5 g of air per m3 of wastewater). Using a lab-scale unit, 65 mg/L FeCl3, 15 min for t, 80 s-1 for G and 19.0 g of air per m3 of wastewater for S*, the removal efficiencies obtained were 89% for COD, 96% for total phosphate, 96% for suspended solids, 98% for turbidity, 91% for apparent color, 47% for TKN and sulphites were not detected in final effluent. For the UASB-DAF systems, still in labscale unit, global efficiencies were 97.7% for COD, 98.0% for total phosphate, 98.9% for suspended solids, 99.5% for turbidity, 97.8% for apparent color and 59.0% for TKN. Using DAF pilot plant, system global efficiencies were 93.6% for COD, 87.1% for suspended solids, 90% for sulphites and 30% for TKN.
59

Avaliação de um sistema piloto composto de reator UASB seguido de lagoa aerada aeróbia e lagoa de decantação no tratamento de esgotos sanitários com elevada contribuição de despejos industriais. / Treatment of sewage containing expressive amount of industrial effluents in a pilot plant system consisted of an UASB reactor followed by an aerated lagoon and a settling pond.

Romero De La Iglesia, Manuel 21 December 2004 (has links)
Este trabalho experimental apresenta os resultados da avaliação do desempenho de uma instalação piloto, composta por reator UASB seguido de lagoa aerada aeróbia e lagoa de decantação, no tratamento dos esgotos afluente a ETE - Jundiaí, que contém elevada contribuição de despejos industriais. O reator UASB e a lagoa de decantação tem volume útil de 3,0 m3 e 2,0 m3, respectivamente. O volume da lagoa aerada aeróbia é variável entre 7,2 m3 e 21,6 m3 de modo a permitir variar o tempo de detenção hidráulica. O sistema foi avaliado em termos da eficiência de remoção de DQO, DBO5, sólidos suspensos, nitrogênio total, fósforo total e cor verdadeira para tempos de detenção hidráulica na lagoa aerada aeróbia variando entre 1,0 e 3,5 dias mantendo, tanto no reator UASB quanto, na lagoa de decantação o tempo de detenção constante em 8,0 horas e 1,8 dia, respectivamente. O sistema completo apresentou uma eficiência de remoção de DQO total entre 85% e 87%, de DBO5 total entre 92% e 96%, de SST entre 81% e 87%, de SSV entre 80 e 88%, de nitrogênio total entre 55 e 57%, de fósforo total entre 60 e 70% e de cor verdadeira entre 50 e 60%, para tempos de detenção hidráulica na lagoa aerada aeróbia variando entre 1,5 e 3,5 dias. O reator UASB foi responsável pela remoção de cerca de 50% da DQO total, 60% da DBO5 total e 40% dos SST do afluente, operando em média com um tempo de detenção hidráulica de 8,0 horas. As eficiências alcançadas no sistema completo produziram um efluente final com uma concentração de DQO total entre 170 e 230 mg/L, de DBO5 total entre 30 e 60 mg/L, de SST entre 30 e 45 mg/L, de SSV entre 24 e 40 mg/L, de nitrogênio total entre 24 e 28 mg NH3/L, de fósforo total entre 3,5 e 5,5 mg P/L e de cor verdadeira entre 375 e 600 mg Pt/L. O sistema pesquisado mostrou-se uma alternativa viável para o tratamento do esgoto afluente à ETE - Jundiaí e poderá resultar em redução da área e em menor consumo de energia que os hoje necessários na ETE - Jundiaí, que emprega um sistema composto por lagoas aeradas aeróbias seguidas de lagoas de decantação. / This experimental investigation was carried out in order to evaluate the performance of a pilot plant, composed of an UASB reactor followed by an aerated lagoon and a settling pond, treating the Wastewater Treatment Plant of Jundiaí city (WWTPJ) influent sewage, which contains in its composition an expressive amount of industrial effluents. The UASB reactor and settling pond have an useful volume of 3.0 m3 and 2.0 m3, respectively. The aerated lagoon volume is variable from 7.2 m3 to 21.6 m3 to make possible the hydraulic retention time variation. The COD, BOD5, suspended solids, total nitrogen, total phosphorus and true colour removal efficiencies of the system were evaluated when the aerated lagoon hydraulic retention time varied from 1.0 to 3.5 days and in the UASB reactor and settling pond was mainteined constant at 8.0 hours and 1.8 day, respectively. The range of removal efficiencies obtained in the system are: 85 - 87% for total COD, 92 - 96% for total BOD5, 81 - 87% for TSS, 80 - 88% for VSS, 55 - 57% for total nitrogen, 60 - 70% for total phosphorus, and 50 - 60% for true color, when the aerated lagoon hydraulic retention time varied from 1.5 to 3.5 days. The UASB reactor operating at 8.0 hours hydraulic retention time removes almost 50% of total COD, 60% of total BOD5 and 40% of TSS from the influent contents. The system performance lead to a final effluent with a total COD, total BOD5, TSS, VSS, total nitrogen, total phosphorus, and true color concentrations in the range of: 170 - 230 mg/L, 30 - 60 mg/L and 30 - 45 mg/L, 24 - 40 mg/L, 24 - 28 mg N/L, 3,5 - 5,5 mg P/L and 375 - 600 mg Pt/L, respectively. The system studied is a practicable alternative for the treatment of the WWTPJ influent sewage, probably with less area and energy saving whem compared to the WWTPJ current needs, which uses a system composed by an aerated lagoon followed by a settling pond
60

Avaliação de um sistema piloto composto de reator UASB seguido de lagoa aerada aeróbia e lagoa de decantação no tratamento de esgotos sanitários com elevada contribuição de despejos industriais. / Treatment of sewage containing expressive amount of industrial effluents in a pilot plant system consisted of an UASB reactor followed by an aerated lagoon and a settling pond.

Manuel Romero De La Iglesia 21 December 2004 (has links)
Este trabalho experimental apresenta os resultados da avaliação do desempenho de uma instalação piloto, composta por reator UASB seguido de lagoa aerada aeróbia e lagoa de decantação, no tratamento dos esgotos afluente a ETE - Jundiaí, que contém elevada contribuição de despejos industriais. O reator UASB e a lagoa de decantação tem volume útil de 3,0 m3 e 2,0 m3, respectivamente. O volume da lagoa aerada aeróbia é variável entre 7,2 m3 e 21,6 m3 de modo a permitir variar o tempo de detenção hidráulica. O sistema foi avaliado em termos da eficiência de remoção de DQO, DBO5, sólidos suspensos, nitrogênio total, fósforo total e cor verdadeira para tempos de detenção hidráulica na lagoa aerada aeróbia variando entre 1,0 e 3,5 dias mantendo, tanto no reator UASB quanto, na lagoa de decantação o tempo de detenção constante em 8,0 horas e 1,8 dia, respectivamente. O sistema completo apresentou uma eficiência de remoção de DQO total entre 85% e 87%, de DBO5 total entre 92% e 96%, de SST entre 81% e 87%, de SSV entre 80 e 88%, de nitrogênio total entre 55 e 57%, de fósforo total entre 60 e 70% e de cor verdadeira entre 50 e 60%, para tempos de detenção hidráulica na lagoa aerada aeróbia variando entre 1,5 e 3,5 dias. O reator UASB foi responsável pela remoção de cerca de 50% da DQO total, 60% da DBO5 total e 40% dos SST do afluente, operando em média com um tempo de detenção hidráulica de 8,0 horas. As eficiências alcançadas no sistema completo produziram um efluente final com uma concentração de DQO total entre 170 e 230 mg/L, de DBO5 total entre 30 e 60 mg/L, de SST entre 30 e 45 mg/L, de SSV entre 24 e 40 mg/L, de nitrogênio total entre 24 e 28 mg NH3/L, de fósforo total entre 3,5 e 5,5 mg P/L e de cor verdadeira entre 375 e 600 mg Pt/L. O sistema pesquisado mostrou-se uma alternativa viável para o tratamento do esgoto afluente à ETE - Jundiaí e poderá resultar em redução da área e em menor consumo de energia que os hoje necessários na ETE - Jundiaí, que emprega um sistema composto por lagoas aeradas aeróbias seguidas de lagoas de decantação. / This experimental investigation was carried out in order to evaluate the performance of a pilot plant, composed of an UASB reactor followed by an aerated lagoon and a settling pond, treating the Wastewater Treatment Plant of Jundiaí city (WWTPJ) influent sewage, which contains in its composition an expressive amount of industrial effluents. The UASB reactor and settling pond have an useful volume of 3.0 m3 and 2.0 m3, respectively. The aerated lagoon volume is variable from 7.2 m3 to 21.6 m3 to make possible the hydraulic retention time variation. The COD, BOD5, suspended solids, total nitrogen, total phosphorus and true colour removal efficiencies of the system were evaluated when the aerated lagoon hydraulic retention time varied from 1.0 to 3.5 days and in the UASB reactor and settling pond was mainteined constant at 8.0 hours and 1.8 day, respectively. The range of removal efficiencies obtained in the system are: 85 - 87% for total COD, 92 - 96% for total BOD5, 81 - 87% for TSS, 80 - 88% for VSS, 55 - 57% for total nitrogen, 60 - 70% for total phosphorus, and 50 - 60% for true color, when the aerated lagoon hydraulic retention time varied from 1.5 to 3.5 days. The UASB reactor operating at 8.0 hours hydraulic retention time removes almost 50% of total COD, 60% of total BOD5 and 40% of TSS from the influent contents. The system performance lead to a final effluent with a total COD, total BOD5, TSS, VSS, total nitrogen, total phosphorus, and true color concentrations in the range of: 170 - 230 mg/L, 30 - 60 mg/L and 30 - 45 mg/L, 24 - 40 mg/L, 24 - 28 mg N/L, 3,5 - 5,5 mg P/L and 375 - 600 mg Pt/L, respectively. The system studied is a practicable alternative for the treatment of the WWTPJ influent sewage, probably with less area and energy saving whem compared to the WWTPJ current needs, which uses a system composed by an aerated lagoon followed by a settling pond

Page generated in 0.0839 seconds