Spelling suggestions: "subject:"P modes""
1 |
Análise da metodologia de calibração dos detectores de Nal(TI) do Laboratório de monitoração in vivo do IPEN pelo método de Monte Carlo / Analysis of the calibration methods on NaI(TI) detectors at the in vivo monitoring laboratory IPEN using the Monte Carlo methodKAKOI, ADELIA A.Y. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:28Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
2 |
Análise da metodologia de calibração dos detectores de Nal(TI) do Laboratório de monitoração in vivo do IPEN pelo método de Monte Carlo / Analysis of the calibration methods on NaI(TI) detectors at the in vivo monitoring laboratory IPEN using the Monte Carlo methodKAKOI, ADELIA A.Y. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:28Z (GMT). No. of bitstreams: 0 / Esse trabalho avalia a metodologia utilizada pelo Laboratório de Monitoração in vivo (LMIV) do IPEN na calibração dos detectores de NaI(Tl) pelo código PENELOPE- penEasy, baseado no Método de Monte Carlo. Inicialmente, foram realizadas simulações sem o simulador antropomórfico com o objetivo de encontrar uma geometria que representasse adequadamente os detectores para exames de corpo inteiro e de tireoide. A aquisição dos dados experimentais foi realizada pelo software GENIE, que é utilizado na rotina do laboratório e as áreas dos fotopicos foram calculadas pelos softwares GENIE e GNUPLOT e pelo método descrito no Ciemat Technical Report, que também fornece os valores de eficiência de fotopico. Fontes de 60Co, 137Cs, 152Eu, 207Bi e 241Am calibradas foram utilizadas nas medições. Os resultados mostraram que o software GENIE é apropriado para ser utilizado nas calibrações de rotina e fontes que possuam picos isolados e definidos pelo detector de NaI(Tl), são ideais para serem utilizadas nas calibrações em eficiência. A simulação MC indica que é possível substituir calibrações experimentais por simulações utilizando uma geometria simplificada do detector de NaI(Tl), mas as grandezas relevantes como a fonte, o detector e o sistema eletrônico devem ser conhecidos com detalhes para que as fontes de erros sistemáticos sejam as menores possíveis. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
3 |
Dosimetria dos sistemas de radiocirurgia estereotáxica com aceleradores lineares equipados com colimadores micro multi-lâminas / Dosimetry systems for stereotactic radiosurgery with linear accelerators equipped with micro multileaf collimatorsVIEIRA, ANDRÉ M. de M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:49Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
|
4 |
Dosimetria dos sistemas de radiocirurgia estereotáxica com aceleradores lineares equipados com colimadores micro multi-lâminas / Dosimetry systems for stereotactic radiosurgery with linear accelerators equipped with micro multileaf collimatorsVIEIRA, ANDRÉ M. de M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:49Z (GMT). No. of bitstreams: 0 / Neste trabalho, as doses absorvidas produzidas em água pelo feixe de radiação de um Acelerador Linear Clínico - CLINAC 600C TM (Varian), com feixes de fótons de 6MV, foram avaliadas teórica e experimentalmente em configurações de campos quadrados, em seguida, em configurações de campos estreitos e circulares, obtidos com um colimador micro multi-lâminas - mMLC m3TM (BrainLab). A avaliação teórica foi feita por meio de cálculos com o Método de Monte Carlo. As curvas de porcentagem de dose profunda PDP e respectivas razões tecido máximo TMRs derivadas, do CLINAC 600C, medidas experimentalmente, foram validadas por meio de comparações com valores de referência, bem como com medidas usando diferentes detectores. Os resultados indicam diferenças menores que 5% pontualmente e em média menores que 1,5% para cada campo avaliado, quando comparados aos valores do comissionamento anterior (realizado no ano de 1999) e aos valores da literatura. Na comparação das medidas feitas com câmara de ionização e com diodo, a média das diferenças pontuais das curvas de PDP foi de -0,6% e as diferenças entre os perfis laterais de dose ficaram dentro de 1%, na região plana. O diodo fornece medidas de perfil com melhor resolução espacial. Os fatores relativos de dose dos campos abertos, atualizados, concordam com os valores de referência anteriores dentro de 1,03% de discrepância. As curvas de distribuição de dose absorvida em água, atualizadas, são, agora, consideradas de referência e permitem caracterizar o feixe desse CLINAC para o cálculo de dose em pacientes. Os espectros de fótons resultantes das simulações por Monte Carlo com os códigos PENELOPE e MCNP concordam em aproximadamente 80% dos pontos amostrados, sendo que as energias médias de (1,6 ± 0,3)MeV, com o MCNP, e de (1,72 ± 0,08)MeV, com o PENELOPE, são coincidentes. O modelo de fonte simples do CLINAC 600C, criado com o código PENELOPE, permite calcular as distribuições de dose em água, de campos abertos, com discrepâncias da ordem de ±1,0% na dose e de ±0,1 cm na posição, se comparados a medidas experimentais. Esses valores de discrepância atingem os critérios propostos inicialmente para validar o modelo de simulação e garantir sua aplicabilidade nas avaliações dosimétricas da Radioterapia desse CLINAC. A descrição geométrica do mMLC m3 para fins de simulação pelo Método de Monte Carlo, utilizando o código PENELOPE, foi considerada satisfatória ao permitir avaliar a transmissão desse colimador dentro de uma incerteza de ±0,2% e calcular uma subdosagem média de (11,4±2,0)%, devida ao efeito lingüeta-vão, que coincide com o valor determinado experimentalmente de (12,5±2,7)%, específicos para esse projeto de colimador. Os programas de simulação por Monte Carlo, que fazem o uso de um modelo de fonte simples do CLINAC 600C, combinado com o modelo completo do mMLC m3, permitiram calcular PDPs em água, de campos conformados, dentro do intervalo de ±1% de discrepância, enquanto que os fatores relativos de dose de campos conformados pelo mMLC puderam ser calculados com incertezas que variam de 1 a 3% concordando com os valores experimentais. Esses campos avaliados representam campos próximos àqueles usados nos tratamentos. Os resultados do trabalho garantem um conhecimento dosimétrico maior do colimador micro multi-lâminas m3, utilizado nas técnicas de radioterapia e radiocirurgia estereotáxica tridimensionais, e fornece uma ferramenta útil na avaliação das doses produzidas em configurações de campos complexas. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
|
5 |
Dosimetria dos sistemas de radiocirurgia estereotáxica com aceleradores lineares equipados com colimadores micro multi-lâminasVieira, André Mozart de Miranda 19 February 2008 (has links)
Neste trabalho, as doses absorvidas produzidas em água pelo feixe de radiação de um Acelerador Linear Clínico - CLINAC 600C TM (Varian), com feixes de fótons de 6MV, foram avaliadas teórica e experimentalmente em configurações de campos quadrados, em seguida, em configurações de campos estreitos e circulares, obtidos com um colimador micro multi-lâminas - mMLC m3TM (BrainLab). A avaliação teórica foi feita por meio de cálculos com o Método de Monte Carlo. As curvas de porcentagem de dose profunda PDP e respectivas razões tecido máximo TMRs derivadas, do CLINAC 600C, medidas experimentalmente, foram validadas por meio de comparações com valores de referência, bem como com medidas usando diferentes detectores. Os resultados indicam diferenças menores que 5% pontualmente e em média menores que 1,5% para cada campo avaliado, quando comparados aos valores do comissionamento anterior (realizado no ano de 1999) e aos valores da literatura. Na comparação das medidas feitas com câmara de ionização e com diodo, a média das diferenças pontuais das curvas de PDP foi de -0,6% e as diferenças entre os perfis laterais de dose ficaram dentro de 1%, na região plana. O diodo fornece medidas de perfil com melhor resolução espacial. Os fatores relativos de dose dos campos abertos, atualizados, concordam com os valores de referência anteriores dentro de 1,03% de discrepância. As curvas de distribuição de dose absorvida em água, atualizadas, são, agora, consideradas de referência e permitem caracterizar o feixe desse CLINAC para o cálculo de dose em pacientes. Os espectros de fótons resultantes das simulações por Monte Carlo com os códigos PENELOPE e MCNP concordam em aproximadamente 80% dos pontos amostrados, sendo que as energias médias de (1,6 ± 0,3)MeV, com o MCNP, e de (1,72 ± 0,08)MeV, com o PENELOPE, são coincidentes. O modelo de fonte simples do CLINAC 600C, criado com o código PENELOPE, permite calcular as distribuições de dose em água, de campos abertos, com discrepâncias da ordem de ±1,0% na dose e de ±0,1 cm na posição, se comparados a medidas experimentais. Esses valores de discrepância atingem os critérios propostos inicialmente para validar o modelo de simulação e garantir sua aplicabilidade nas avaliações dosimétricas da Radioterapia desse CLINAC. A descrição geométrica do mMLC m3 para fins de simulação pelo Método de Monte Carlo, utilizando o código PENELOPE, foi considerada satisfatória ao permitir avaliar a transmissão desse colimador dentro de uma incerteza de ±0,2% e calcular uma subdosagem média de (11,4±2,0)%, devida ao efeito lingüeta-vão, que coincide com o valor determinado experimentalmente de (12,5±2,7)%, específicos para esse projeto de colimador. Os programas de simulação por Monte Carlo, que fazem o uso de um modelo de fonte simples do CLINAC 600C, combinado com o modelo completo do mMLC m3, permitiram calcular PDPs em água, de campos conformados, dentro do intervalo de ±1% de discrepância, enquanto que os fatores relativos de dose de campos conformados pelo mMLC puderam ser calculados com incertezas que variam de 1 a 3% concordando com os valores experimentais. Esses campos avaliados representam campos próximos àqueles usados nos tratamentos. Os resultados do trabalho garantem um conhecimento dosimétrico maior do colimador micro multi-lâminas m3, utilizado nas técnicas de radioterapia e radiocirurgia estereotáxica tridimensionais, e fornece uma ferramenta útil na avaliação das doses produzidas em configurações de campos complexas. / In this work, absorbed dose to water produced by the radiation beam of a clinical linear accelerator - CLINAC 600C TM (Varian), with a photon beam of 6 MV, were evaluated both theoretically and experimentally. This determination includes square and circular field configurations, the last one obtained with a micro multileaf collimator - mMLC m3TM (BrainLab). Theoretical evaluation was performed throughout Monte Carlo method. Experimental measurements of Percentage Depht Dose - PDD and derived Tissue Maximum Ratio - TMR curves from CLINAC 600C were validated by comparison with reference values as well as with measurements using different detectors. The results indicate local differences smaller than 5% and average differences smaller than 1,5% for each evaluated field, if they are compared to the previous commissioning values (made in 1999) and to the values of literature. Comparisons of ionization chamber and diode result in an average local difference of -0,6% for PDD measurements, and within 1% for lateral dose profiles, at depth, in the flat region. Diode provides measurements with better spatial resolution. Current output factors of open fields agree with reference values within 1,03% of discrepancy level. Current absorbed dose distributions in water are, now, considered reference values and allow characterization of this CLINAC for patient dose calculation. The photon spectra resulting from simulations with PENELOPE and MCNP codes agree approximately in 80% of the sampled points, in what average energies of (1,6 ± 0,3)MeV, with MCNP, and of (1,72 ± 0,08)MeV, with PENELOPE, are coincident. The created simple source model of the CLINAC 600C, using the PENELOPE code, allows one to calculate dose distributions in water, for open fields, with discrepancies of the order of ±1,0% in dose and of ±0,1cm in position, if they are compared to experimental measurements. These values met the initial proposed criteria to validate the simulation model and guarantee its applicability in dosimetric evaluations of radiotherapy with this CLINAC. The geometrical description of the mMLC m3 for Monte Carlo purposes, using the PENELOPE code, was considered satisfactory, providing the characterization of relevant physical parameters such as the transmission of the mMLC, within an estimated uncertainty of ±0,2%, and the average underdose of (11,4±2,0)%, due the tongue and groove effect, which is coincident with the experimental value of (12,5±2,7)%, for this particular collimator design. The Monte Carlo simulation codes which combine a single source model of the CLINAC 600C with the full m3 model, allows to calculate dose distributions in water for conformal beams within the discrepancy level of ±1%. However, output factors of conformal beams with the mMLC can be calculated with uncertainties varying from 1 to 3%, when they are compared to experimental results. These evaluated fields represent, and come close to treatment fields. The results of this work guarantee a better dosimetric knowledge of the micro multileaf collimator m3, which is used in three-dimensional stereotactic radiotherapy and radiosurgery techniques. This provides a useful tool in the evaluation of the mMLC as well as the absorbed doses produced in complex field configurations.
|
6 |
Dosimetria dos sistemas de radiocirurgia estereotáxica com aceleradores lineares equipados com colimadores micro multi-lâminasAndré Mozart de Miranda Vieira 19 February 2008 (has links)
Neste trabalho, as doses absorvidas produzidas em água pelo feixe de radiação de um Acelerador Linear Clínico - CLINAC 600C TM (Varian), com feixes de fótons de 6MV, foram avaliadas teórica e experimentalmente em configurações de campos quadrados, em seguida, em configurações de campos estreitos e circulares, obtidos com um colimador micro multi-lâminas - mMLC m3TM (BrainLab). A avaliação teórica foi feita por meio de cálculos com o Método de Monte Carlo. As curvas de porcentagem de dose profunda PDP e respectivas razões tecido máximo TMRs derivadas, do CLINAC 600C, medidas experimentalmente, foram validadas por meio de comparações com valores de referência, bem como com medidas usando diferentes detectores. Os resultados indicam diferenças menores que 5% pontualmente e em média menores que 1,5% para cada campo avaliado, quando comparados aos valores do comissionamento anterior (realizado no ano de 1999) e aos valores da literatura. Na comparação das medidas feitas com câmara de ionização e com diodo, a média das diferenças pontuais das curvas de PDP foi de -0,6% e as diferenças entre os perfis laterais de dose ficaram dentro de 1%, na região plana. O diodo fornece medidas de perfil com melhor resolução espacial. Os fatores relativos de dose dos campos abertos, atualizados, concordam com os valores de referência anteriores dentro de 1,03% de discrepância. As curvas de distribuição de dose absorvida em água, atualizadas, são, agora, consideradas de referência e permitem caracterizar o feixe desse CLINAC para o cálculo de dose em pacientes. Os espectros de fótons resultantes das simulações por Monte Carlo com os códigos PENELOPE e MCNP concordam em aproximadamente 80% dos pontos amostrados, sendo que as energias médias de (1,6 ± 0,3)MeV, com o MCNP, e de (1,72 ± 0,08)MeV, com o PENELOPE, são coincidentes. O modelo de fonte simples do CLINAC 600C, criado com o código PENELOPE, permite calcular as distribuições de dose em água, de campos abertos, com discrepâncias da ordem de ±1,0% na dose e de ±0,1 cm na posição, se comparados a medidas experimentais. Esses valores de discrepância atingem os critérios propostos inicialmente para validar o modelo de simulação e garantir sua aplicabilidade nas avaliações dosimétricas da Radioterapia desse CLINAC. A descrição geométrica do mMLC m3 para fins de simulação pelo Método de Monte Carlo, utilizando o código PENELOPE, foi considerada satisfatória ao permitir avaliar a transmissão desse colimador dentro de uma incerteza de ±0,2% e calcular uma subdosagem média de (11,4±2,0)%, devida ao efeito lingüeta-vão, que coincide com o valor determinado experimentalmente de (12,5±2,7)%, específicos para esse projeto de colimador. Os programas de simulação por Monte Carlo, que fazem o uso de um modelo de fonte simples do CLINAC 600C, combinado com o modelo completo do mMLC m3, permitiram calcular PDPs em água, de campos conformados, dentro do intervalo de ±1% de discrepância, enquanto que os fatores relativos de dose de campos conformados pelo mMLC puderam ser calculados com incertezas que variam de 1 a 3% concordando com os valores experimentais. Esses campos avaliados representam campos próximos àqueles usados nos tratamentos. Os resultados do trabalho garantem um conhecimento dosimétrico maior do colimador micro multi-lâminas m3, utilizado nas técnicas de radioterapia e radiocirurgia estereotáxica tridimensionais, e fornece uma ferramenta útil na avaliação das doses produzidas em configurações de campos complexas. / In this work, absorbed dose to water produced by the radiation beam of a clinical linear accelerator - CLINAC 600C TM (Varian), with a photon beam of 6 MV, were evaluated both theoretically and experimentally. This determination includes square and circular field configurations, the last one obtained with a micro multileaf collimator - mMLC m3TM (BrainLab). Theoretical evaluation was performed throughout Monte Carlo method. Experimental measurements of Percentage Depht Dose - PDD and derived Tissue Maximum Ratio - TMR curves from CLINAC 600C were validated by comparison with reference values as well as with measurements using different detectors. The results indicate local differences smaller than 5% and average differences smaller than 1,5% for each evaluated field, if they are compared to the previous commissioning values (made in 1999) and to the values of literature. Comparisons of ionization chamber and diode result in an average local difference of -0,6% for PDD measurements, and within 1% for lateral dose profiles, at depth, in the flat region. Diode provides measurements with better spatial resolution. Current output factors of open fields agree with reference values within 1,03% of discrepancy level. Current absorbed dose distributions in water are, now, considered reference values and allow characterization of this CLINAC for patient dose calculation. The photon spectra resulting from simulations with PENELOPE and MCNP codes agree approximately in 80% of the sampled points, in what average energies of (1,6 ± 0,3)MeV, with MCNP, and of (1,72 ± 0,08)MeV, with PENELOPE, are coincident. The created simple source model of the CLINAC 600C, using the PENELOPE code, allows one to calculate dose distributions in water, for open fields, with discrepancies of the order of ±1,0% in dose and of ±0,1cm in position, if they are compared to experimental measurements. These values met the initial proposed criteria to validate the simulation model and guarantee its applicability in dosimetric evaluations of radiotherapy with this CLINAC. The geometrical description of the mMLC m3 for Monte Carlo purposes, using the PENELOPE code, was considered satisfactory, providing the characterization of relevant physical parameters such as the transmission of the mMLC, within an estimated uncertainty of ±0,2%, and the average underdose of (11,4±2,0)%, due the tongue and groove effect, which is coincident with the experimental value of (12,5±2,7)%, for this particular collimator design. The Monte Carlo simulation codes which combine a single source model of the CLINAC 600C with the full m3 model, allows to calculate dose distributions in water for conformal beams within the discrepancy level of ±1%. However, output factors of conformal beams with the mMLC can be calculated with uncertainties varying from 1 to 3%, when they are compared to experimental results. These evaluated fields represent, and come close to treatment fields. The results of this work guarantee a better dosimetric knowledge of the micro multileaf collimator m3, which is used in three-dimensional stereotactic radiotherapy and radiosurgery techniques. This provides a useful tool in the evaluation of the mMLC as well as the absorbed doses produced in complex field configurations.
|
7 |
Desenvolvimento de um software de Monte Carlo para transporte de fótons em estruturas de voxels usando unidades de processamento gráfico / Development of a GPU Monte Carlo software for photon transport in voxel structuresBELLEZZO, MURILLO 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T10:59:52Z
No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T10:59:52Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
8 |
Desenvolvimento de um software de Monte Carlo para transporte de fótons em estruturas de voxels usando unidades de processamento gráfico / Development of a GPU Monte Carlo software for photon transport in voxel structuresBELLEZZO, MURILLO 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T10:59:52Z
No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T10:59:52Z (GMT). No. of bitstreams: 0 / Sendo o método mais preciso para estimar a dose absorvida em radioterapia, o Método de Monte Carlo (MMC) tem sido amplamente utilizado no planejamento de tratamento radioterápico. No entanto, a sua eciência pode ser melhorada para aplicações clínicas de rotina. Nesta dissertação é apresentado o código CUBMC, um código de Monte Carlo que simula o transporte de fótons para cálculo de dose, desenvolvido na plataforma CUDA (Compute Unified Device Architecture). A simulação de eventos físicos é baseada no algoritmo presente no código PENELOPE, e as tabelas de seção de choque utilizadas são geradas pela rotina MATERIAL, também presente no código PENELOPE. Os fótons são transportados em objetos simuladores descritos por voxels. Existem duas abordagens distintas utilizadas para a simulação. A primeira delas obriga o fóton a realizar uma parada toda vez que cruza a fronteira de um voxel, a segunda e pelo Método de Woodcock, onde o fóton ignora a existência de fronteiras e é transportado em um meio homogêneo fictício. O código CUBMC tem como objetivo ser uma opção de código simulador que, ao utilizar a capacidade de processamento paralelo de unidades de processamento gráfico (GPU), apresente alto desempenho em máquinas compactas e de baixo custo, podendo assim ser aplicado em casos clínicos e incorporado a sistemas de planejamento de tratamento em radioterapia. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
Page generated in 0.0389 seconds