1 |
Controle de conversor multifuncional aplicado a um sistema de geração distribuída despachável baseado em um grupo motor gerador dieselFogli, Gabriel Azevedo 26 March 2018 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-05-15T18:53:08Z
No. of bitstreams: 1
gabrielazevedofogli.pdf: 14398243 bytes, checksum: 29f4f96b36d404d928ede5833fc882f8 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-05-22T14:44:16Z (GMT) No. of bitstreams: 1
gabrielazevedofogli.pdf: 14398243 bytes, checksum: 29f4f96b36d404d928ede5833fc882f8 (MD5) / Made available in DSpace on 2018-05-22T14:44:16Z (GMT). No. of bitstreams: 1
gabrielazevedofogli.pdf: 14398243 bytes, checksum: 29f4f96b36d404d928ede5833fc882f8 (MD5)
Previous issue date: 2018-03-26 / Este trabalho apresenta um estudo sobre a integração de uma fonte despachável, baseada em um grupo motor gerador diesel, em uma microrrede em corrente alternada através de um conversor de dois estágios, formado por dois conversores fonte de tensão em conexão back-to-back. A microrrede pode operar conectada à rede secundária de distribuição, injetando a potência ativa proveniente da fonte despachável, ou de modo isolado. Para este segundo caso, duas estratégias de funcionamento são propostas. A primeira interliga diretamente o grupo motor gerador ao barramento de cargas, enquanto o conversor de dois estágios funciona como filtro ativo de potência. A outra opção consiste em utilizar o conversor de dois estágios no modo formador de rede, alimentando o barramento de cargas. Como cada uma das unidades que compõem o conversor de dois estágios tem uma finalidade, os controladores utilizados de cada um dos lados possuem particularidades. O conversor conectado aos terminais do grupo motor gerador é responsável por drenar correntes senoidais e regular a tensão do barramento de corrente contínua. Para este conversor é utilizado um controlador proporcional—integral, projetado no sistema de coordenadas síncrono. Uma estratégia de compensação dos parâmetros do tempo morto dos interruptores semicondutores foi implementada para reduzir a geração de harmônicos não característicos. Do outro lado, no conversor de saída, responsável pela integração com a rede secundária, foi utilizado um controlador proporcional—integral, projetado no sistema de coordenadas síncrono, com múltiplos integradores, adicionados para compensar correntes harmônicas. De acordo com o modo de funcionamento do sistema é utilizado um método para obtenção das correntes de referência. Quatro modos de funcionamento podem ser aplicados neste sistema: (i) alimentador de rede, (ii) formador de rede, (iii) auxiliador de rede e (iv) condicionador de rede. Para o modo Formador de Rede faz-se necessário a inclusão de uma malha de controle externa projetado para regular a tensão CA no barramento de cargas. Resultados experimentais são apresentados para validar os modelos matemáticos e as estratégias de controle usadas neste trabalho. Todo o algoritmo de controle é implementado em um controlador digital de sinais TMS320F28335 fabricado pela Texas Instruments. / This document presents a study on dispatchable source based on Diesel Gen-set connected to AC microgrid. The Diesel generator is connected to network grid through two-stage converter composed of two Voltage-sourced converters in back-to-back (B2B-VSC) connection. The AC microgrid can operate in a grid-connected mode, injecting active power from the dispatchable source, or in an isolated mode. In the second case, two operating conditions are proposed, in which the first option interconnects Diesel gen-set direct to load bus and B2B-VSC works as Active Power Filter. Another option is to operate the B2B-VSC as grid—former. Due the fact that each converter of B2B-VSC has a specific goal, different control strategies are used for each one. The VSC connected to Diesel generator terminals is responsible to drain sinusoidal currents and to regulate the DC voltage. In the this converter, PI—SRF Controller is applied in a inner current control loop together with a dead-time compensation strategy. In the other side of B2B-VSC, responsible of multi-task control, is applied a control strategy modelled in a synchronous coordinate system with multiple integrators to mitigate the harmonic currents. According to the operation mode is used a different current reference is given. Four operation modes can be used in this microgrid: (i) grid-feeding, (ii) grid-forming, (iii) grid-supporting and (iv) grid-conditioning. In grid—forming mode an outer loop is added to regulate the AC load bus voltage. Experimental results are presented to validate the mathematical modelling and controller strategies. Finally, suggestions to continue this research are proposed. The control algorithm is implemented in a digital signal processor TMS320F28335 made by Texas Instruments.
|
2 |
Integração de um grupo motor gerador diesel em uma rede secundária de distribuição através de um conversor estático fonte de tensãoFogli, Gabriel Azevedo 19 March 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-26T12:14:24Z
No. of bitstreams: 1
gabrielazevedofogli.pdf: 13619054 bytes, checksum: d260cb2571f242e43eab89132a03d62c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-26T12:26:45Z (GMT) No. of bitstreams: 1
gabrielazevedofogli.pdf: 13619054 bytes, checksum: d260cb2571f242e43eab89132a03d62c (MD5) / Made available in DSpace on 2017-04-26T12:26:45Z (GMT). No. of bitstreams: 1
gabrielazevedofogli.pdf: 13619054 bytes, checksum: d260cb2571f242e43eab89132a03d62c (MD5)
Previous issue date: 2014-03-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta dissertação apresenta um estudo de conexão de um grupo gerador-diesel (GMG) trifásico em uma rede secundária de distribuição de energia elétrica. A integração do GMG é feita por uma unidade de processamento de energia (PPU) composta por um retificador trifásico não controlado conectado em série com um conversor fonte de tensão (VSC) modulado com uma estratégia de modulação por largura de pulso. O GMG pode operar de duas maneiras distintas: (i) modo standby (interligado) ou (ii) modo isolado. O conversor de saída da PPU pode ser controlado para injetar potência ativa na rede CA, ou como um filtro ativo de potência (FAP) compensando potência reativa e correntes harmônicas nos terminais das cargas. O VSC de interface é controlado no modo de corrente (CMC), sendo seus controladores projetados a partir de funções de transferência obtidas com o modelo matemático do sistema elétrico nas coordenadas dq0. Esses controladores são projetados com múltiplos integradores para garantir a qualidade da forma de onda da corrente injetada na rede CA. Dependendo do modo de operação é utilizada uma malha adicional para regular a tensão do barramento CC do conversor de interface. Para validar o modelo matemático e o algoritmo de controle são realizadas simulações digitais no programa PSIM. Resultados experimentais, obtidos com um protótipo de laboratório, cujos controladores foram implementados em um processador digital de sinais TMS320F28335 da Texas Instruments, são usados para validar as estratégias de controle propostas. / This dissertation presents a study about the connection of a three-phase Diesel Genset (DG) to a secondary distribution network. The integration of DG is done by a Power Processing Unit (PPU) composed of a three-phase rectifier connected in series with a Pulse Width Modulated Voltage Source Converter (VSC). The DG can operate in two distinct modes: (i) standby (interconnected) or (ii) islanding. The PPU’s output converter can be controlled to inject active power into AC electric grid, or as an Active Power Filter (APF), compensating the reactive power and harmonics currents at the load terminals. The VSC is controlled employing the current mode control (CMC), and its compensators are designed based on the electrical system transfer function in dq0 coordinates. Multiple rotating synchronous reference frame integrators (PI-MRI) are used to ensure the quality of the generated power. Depending on the operating mode, an additional loop is used to regulate the DC bus voltage. In order to validate the mathematical model and the control algorithm, digital simulations using PSIM are performed. Experimental results obtained with the prototype, which controllers were implemented in a TMS320F28335 of Texas Instruments are used to validate the proposed control strategies.
|
Page generated in 0.0162 seconds