Spelling suggestions: "subject:"control"" "subject:"descontrol""
1 |
DYNAMIC MODELING AND CONTROL OF REACTIVE DISTILLATION FOR HYDROGENATION OF BENZENEAluko, Obanifemi 16 January 2010 (has links)
This work presents a modeling and control study of a reactive distillation column
used for hydrogenation of benzene. A steady state and a dynamic model have been
developed to investigate control structures for the column. The most important aspects of
this control problem are that the purity of the product streams regarding benzene need to
be met. At the same time as little toluene as possible should be converted. The former is a
constraint imposed by EPA regulations while the latter is tied to process economics due
to the high octane number of toluene. It is required to satisfy both of these objectives
even under the influence of disturbances, as the feed composition changes on a regular
basis. The dynamic model is used for developing transfer function models of two
potential control structures. Pairing of inputs and outputs is performed based upon the
Relative Gain Array (RGA) and PI controllers were designed for each control structure.
The controller performance was then compared in simulation studies. From our results,
control structure 2 performed better than control structure 1. The main advantage of CS2
over CS1 is noticed in the simulation of feed composition disturbance rejection, where
CS2 returns all variables back to steady state within 3 hrs while it take CS1 more than 20
hrs to return the temperature variables back to steady state.
|
2 |
Modeling and Analysis of Hydraulic Energy Storage System for Hybrid LocomotivesZhang, Boya January 2010 (has links)
No description available.
|
3 |
Model establish and controller design for active front steering control systemHsiao, Chin-yuan 09 August 2012 (has links)
The goal of this thesis is to develop an active front steering(AFS) control system which can apply to ordinary vehicle. This AFS control system stabilizes the driving vehicle and reduces the possibility of rollover. This thesis uses magic formula tire model and constructs a vehicle model with eight degrees of freedom to study the dynamic behavior of the real driving vehicle. This thesis constructs a vehicle model with three degrees of freedom and eight degree of freedom, compare with two vehicle model, we adopt eight vehicle model in this thesis. The advantages of PI controller are low cost and easy to modify, so this thesis adopts PI controller as the control strategy. This study uses four simulate methods and compares the simulated results to develop the AFS control system which can apply to ordinary vehicle.
|
4 |
A multiple-input single ended primary inductor converter for modular micro-grids with hybrid low-power sourcesZhao, Ruichen 28 October 2010 (has links)
This thesis studies a multiple-input single ended primary inductor converter (MI SEPIC) topology. The configuration allows the integration of different low-power distributed generation sources, such as individual photovoltaic modules, fuel cells, and small residential wind generators, into a common dc main bus. The current source interface allows the integration of all types of sources without the addition of filters; sources that require a nearly constant input current, such as fuel cells. In addition to discussing the circuit’s main models and operation, the thesis evaluates the stability under a decentralized PI control scheme through small signal analysis. The analysis is verified with simulations and experiments with prototypes. A derived circuit topology, the isolated MI SEPIC, is also explored here. In addition, a nonlinear control scheme, Lyapunov-based control, is implemented to stabilize an MI SEPIC. / text
|
5 |
Averaging level control in the presence of frequent inlet flow upsetsRosander, Peter January 2012 (has links)
Buffer tanks are widely used within the process industry to prevent flow variations from being directly propagated throughout a plant. The capacity of the tank is used to smoothly transfer inlet flow upsets to the outlet. Ideally, the tank thus works as a low pass filter where the available tank capacity limits the achievable flow smoothing. For infrequently occurring upsets, where the system has time to reach steady state between flow changes, the averaging level control problem has been extensively studied. After an inlet flow change, flow filtering has traditionally been obtained by letting the tank level deviate from its nominal value while slowly adapting the outlet to cancel out the flow imbalance and eventually bringing back the level to its set-point. The system is then again in steady state and ready to surge the next upset. By ensuring that the single largest upset can be handled without violating the level constraints, satisfactory flow smoothing is obtained. In this thesis, the smoothing of frequently changing inlet flows is addressed. In this case, standard level controllers struggle to obtain acceptable flow smoothing since the system rarely is in steady state and flow upsets can thus not be treated as separate events. To obtain a control law that achieves optimal filtering while directly accounting for future upsets, the averaging level control problem was approached using robust model predictive control (MPC). The robust MPC differs in the way it obtains flow smoothing by not returning the tank level to a fixed set-point. Instead, it lets the steady state tank level depend on the current value of the inlet flow. This insight was then used to propose a linear control structure, designed to filter frequent upsets optimally. Analyses and simulation results indicate that the proposed linear and robust MPC controller obtain flow smoothing comparable to the standard optimal averaging level controllers for infrequent upsets while handling frequent upsets considerably better.
|
6 |
Projeto e análise de controladores robustos aplicados a inversores trifásicos de fontes ininterruptas de energia (UPS)Barden, Alisson Thomas January 2016 (has links)
O objetivo principal deste trabalho é o desenvolvimento de controladores robustos baseados no princípio do modelo interno, em referenciais síncrono e estacionário, para aplicação ao estágio de saída de uma fonte ininterrupta de energia (UPS) a fim de minimizar a distorção na tensão de saída causada pela conexão de cargas não lineares balanceadas e desbalanceadas. A formulação em referencial estacionário (abc) é realizada através da aplicação de controladores com múltiplos modos ressonantes, a fim de se estabelecer erro nulo ao seguimento de referência senoidal e rejeição de distúrbios na tensão de saída devido às correntes com elevado conteúdo harmônico drenadas pelas cargas. Além disso, o controle é formulado em referencial síncrono (dq0) utilizando controladores Proporcional-Integral (PI) convencionais muito difundidos na maioria das aplicações comerciais de UPS. O projeto de ambos controladores é realizado utilizando uma metodologia de controle robusto com realimentação de estados, onde os parâmetros dos controladores são determinados através da resolução de um problema de otimização convexa sujeito a um conjunto de restrições na forma de desigualdades matriciais lineares (LMI). Uma análise comparativa de desempenho é realizada entre controladores com um modo ressonante (sintonizado na fundamental) e o PI em dq0, pois apresentam estruturas funcionalmente equivalentes sob a ótica do princípio do modelo interno aplicada a seus respectivos referenciais. Além do mais, demonstra-se a melhoria no desempenho com o uso dos controladores múltiplo ressonantes em referencial estacionário onde escolhe-se as frequências de ressonância de cada modo de maneira a suprimir os efeitos de harmônicas específicas na tensão de saída da UPS. A análise comparativa entre os controladores propostos é realizada através de simulações numéricas, utilizando os procedimentos de ensaio dinâmico e estático e as exigências estabelecidas pela norma internacional IEC 62040-3. / The main objective of this work is the development of robust controllers based on the internalmodel principle, in synchronous and stationary frames, applied to the output stage of an uninterruptible power supply (UPS), in order to minimize the output voltage distortion caused by the connection of balanced and unbalanced nonlinear loads. The formulation in stationary abc-frame is accomplished through the aplication of a multiple resonant controller, so that, it is possible to achieve zero-error tracking of the sinusoidal reference and disturbances rejection on the output voltage due to the high amount of harmonic currents drained by the loads. Moreover, a controller in synchronous reference frame (dq0 axis) is formulated through the application of conventional Proportional-Integral (PI) controllers which are widely used in comercial UPS applications. The design of both controllers is formulated using a state-feedback robust controlmethod, in which the controller parameters are determined by solving a convex optimization problem subject to a set of LMI constraints. A comparative analysis on the performance of the single-mode resonant controller (tuned at the fundamental frequency) and the PI controller is performed, because these controllers are functionally equivalent in the sense of the internal model principle applied to their respective frames. Furthermore, the improvement in performance is demostrated with the use of multiple resonant controllers in stationary abc-frame where the resonance frequencies are chosen to suppress the effects of a specific harmonic in the UPS output voltage. The comparative analysis of the proposed controllers is performed through numerical simulations, making use of the dynamical and steady-state test methods and performance requirements defined by the IEC 62040-3 international stardard.
|
7 |
Ammonium Feedback Control in Wastewater Treatment PlantsÅmand, Linda January 2014 (has links)
The aeration process is often the single largest consumer of electricity in a wastewater treatment plant. Aeration in biological reactors provides microorganisms with oxygen which is required to convert ammonium to nitrate. Ammonium is toxic for aqueous ecosystems and contributes to eutrophication. The importance of aeration for the treatment results in combination with the high costs motivates automatic control of the aeration process. This thesis is devoted to ammonium feedback control in municipal wastewater treatment plants. With ammonium feedback control, the aeration intensity is changed based on a measurement of the outlet ammonium concentration. The main focus of the thesis is design, implementation, evaluation and improvement of ammonium PI (proportional-integral) controllers. The benefits of ammonium feedback control are established through long-term experiments at three large wastewater treatment plants in Stockholm, Sweden. With ammonium feedback control, energy savings up to around 10 % were achieved compared to keeping the dissolved oxygen concentration constant. The experiments generated several lessons learned with regard to implementation and evaluation of controllers in full-scale operation. The thesis has established guidelines on how to design ammonium feedback controllers for situations when cost-effective operation is the overall aim. Simulations have demonstrated the importance to limit the dissolved oxygen concentration in the process and under what conditions the energy saving with ammonium feedback control is large. The final part of the thesis treats improvements of ammonium PI control through minor modifications to the control structure or controller. Three strategies were studied: gain scheduling control, repetitive control, and a strategy reacting to oxygen peaks in the last aerobic zone. The strategies all had their benefits but the ammonium feedback controller was the key factor to improved aeration control.
|
8 |
Evaluation of a Programmable Hydraulic Valve for Drill Rig Applicationsde Brun Mangs, Jonathan, Tillquist, Mikael January 2018 (has links)
The increase of intelligent systems can be seen in every industry. Integrated sensors and processors are used with internal control systems to create better performance for mobile hydraulic applications. The report describes how an evaluation was made to see if the productivity of a drill rig could be increased. This was done by implementing a programmable hydraulic valve to control the hydraulic drilling functions. The productivity would be increased by reducing the downtime due to jamming in the drill hole. Jamming occur when the system does not compensate for changes in rock conditions. By conducting a series of tests in a controlled environment with simulated loads, the response time of the CMA system and original system could be determined and compared. The CMA system had a response time that was 60-64% faster than the original system. Two different implementations of a controller was tested. Ziegler-Nichols method was used to get the initial value of the PI parameters. The controller that was implemented onboard the valve’s CPU was considered more successfull to reduce jamming. A drill test was conducted to ensure that the programmable valve could handle a drilling procedure with the controller that was implemented onboard the valve’s CPU. The valve handled the drilling procedure well.
|
9 |
Projeto e análise de controladores robustos aplicados a inversores trifásicos de fontes ininterruptas de energia (UPS)Barden, Alisson Thomas January 2016 (has links)
O objetivo principal deste trabalho é o desenvolvimento de controladores robustos baseados no princípio do modelo interno, em referenciais síncrono e estacionário, para aplicação ao estágio de saída de uma fonte ininterrupta de energia (UPS) a fim de minimizar a distorção na tensão de saída causada pela conexão de cargas não lineares balanceadas e desbalanceadas. A formulação em referencial estacionário (abc) é realizada através da aplicação de controladores com múltiplos modos ressonantes, a fim de se estabelecer erro nulo ao seguimento de referência senoidal e rejeição de distúrbios na tensão de saída devido às correntes com elevado conteúdo harmônico drenadas pelas cargas. Além disso, o controle é formulado em referencial síncrono (dq0) utilizando controladores Proporcional-Integral (PI) convencionais muito difundidos na maioria das aplicações comerciais de UPS. O projeto de ambos controladores é realizado utilizando uma metodologia de controle robusto com realimentação de estados, onde os parâmetros dos controladores são determinados através da resolução de um problema de otimização convexa sujeito a um conjunto de restrições na forma de desigualdades matriciais lineares (LMI). Uma análise comparativa de desempenho é realizada entre controladores com um modo ressonante (sintonizado na fundamental) e o PI em dq0, pois apresentam estruturas funcionalmente equivalentes sob a ótica do princípio do modelo interno aplicada a seus respectivos referenciais. Além do mais, demonstra-se a melhoria no desempenho com o uso dos controladores múltiplo ressonantes em referencial estacionário onde escolhe-se as frequências de ressonância de cada modo de maneira a suprimir os efeitos de harmônicas específicas na tensão de saída da UPS. A análise comparativa entre os controladores propostos é realizada através de simulações numéricas, utilizando os procedimentos de ensaio dinâmico e estático e as exigências estabelecidas pela norma internacional IEC 62040-3. / The main objective of this work is the development of robust controllers based on the internalmodel principle, in synchronous and stationary frames, applied to the output stage of an uninterruptible power supply (UPS), in order to minimize the output voltage distortion caused by the connection of balanced and unbalanced nonlinear loads. The formulation in stationary abc-frame is accomplished through the aplication of a multiple resonant controller, so that, it is possible to achieve zero-error tracking of the sinusoidal reference and disturbances rejection on the output voltage due to the high amount of harmonic currents drained by the loads. Moreover, a controller in synchronous reference frame (dq0 axis) is formulated through the application of conventional Proportional-Integral (PI) controllers which are widely used in comercial UPS applications. The design of both controllers is formulated using a state-feedback robust controlmethod, in which the controller parameters are determined by solving a convex optimization problem subject to a set of LMI constraints. A comparative analysis on the performance of the single-mode resonant controller (tuned at the fundamental frequency) and the PI controller is performed, because these controllers are functionally equivalent in the sense of the internal model principle applied to their respective frames. Furthermore, the improvement in performance is demostrated with the use of multiple resonant controllers in stationary abc-frame where the resonance frequencies are chosen to suppress the effects of a specific harmonic in the UPS output voltage. The comparative analysis of the proposed controllers is performed through numerical simulations, making use of the dynamical and steady-state test methods and performance requirements defined by the IEC 62040-3 international stardard.
|
10 |
Projeto e análise de controladores robustos aplicados a inversores trifásicos de fontes ininterruptas de energia (UPS)Barden, Alisson Thomas January 2016 (has links)
O objetivo principal deste trabalho é o desenvolvimento de controladores robustos baseados no princípio do modelo interno, em referenciais síncrono e estacionário, para aplicação ao estágio de saída de uma fonte ininterrupta de energia (UPS) a fim de minimizar a distorção na tensão de saída causada pela conexão de cargas não lineares balanceadas e desbalanceadas. A formulação em referencial estacionário (abc) é realizada através da aplicação de controladores com múltiplos modos ressonantes, a fim de se estabelecer erro nulo ao seguimento de referência senoidal e rejeição de distúrbios na tensão de saída devido às correntes com elevado conteúdo harmônico drenadas pelas cargas. Além disso, o controle é formulado em referencial síncrono (dq0) utilizando controladores Proporcional-Integral (PI) convencionais muito difundidos na maioria das aplicações comerciais de UPS. O projeto de ambos controladores é realizado utilizando uma metodologia de controle robusto com realimentação de estados, onde os parâmetros dos controladores são determinados através da resolução de um problema de otimização convexa sujeito a um conjunto de restrições na forma de desigualdades matriciais lineares (LMI). Uma análise comparativa de desempenho é realizada entre controladores com um modo ressonante (sintonizado na fundamental) e o PI em dq0, pois apresentam estruturas funcionalmente equivalentes sob a ótica do princípio do modelo interno aplicada a seus respectivos referenciais. Além do mais, demonstra-se a melhoria no desempenho com o uso dos controladores múltiplo ressonantes em referencial estacionário onde escolhe-se as frequências de ressonância de cada modo de maneira a suprimir os efeitos de harmônicas específicas na tensão de saída da UPS. A análise comparativa entre os controladores propostos é realizada através de simulações numéricas, utilizando os procedimentos de ensaio dinâmico e estático e as exigências estabelecidas pela norma internacional IEC 62040-3. / The main objective of this work is the development of robust controllers based on the internalmodel principle, in synchronous and stationary frames, applied to the output stage of an uninterruptible power supply (UPS), in order to minimize the output voltage distortion caused by the connection of balanced and unbalanced nonlinear loads. The formulation in stationary abc-frame is accomplished through the aplication of a multiple resonant controller, so that, it is possible to achieve zero-error tracking of the sinusoidal reference and disturbances rejection on the output voltage due to the high amount of harmonic currents drained by the loads. Moreover, a controller in synchronous reference frame (dq0 axis) is formulated through the application of conventional Proportional-Integral (PI) controllers which are widely used in comercial UPS applications. The design of both controllers is formulated using a state-feedback robust controlmethod, in which the controller parameters are determined by solving a convex optimization problem subject to a set of LMI constraints. A comparative analysis on the performance of the single-mode resonant controller (tuned at the fundamental frequency) and the PI controller is performed, because these controllers are functionally equivalent in the sense of the internal model principle applied to their respective frames. Furthermore, the improvement in performance is demostrated with the use of multiple resonant controllers in stationary abc-frame where the resonance frequencies are chosen to suppress the effects of a specific harmonic in the UPS output voltage. The comparative analysis of the proposed controllers is performed through numerical simulations, making use of the dynamical and steady-state test methods and performance requirements defined by the IEC 62040-3 international stardard.
|
Page generated in 0.0516 seconds