• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 244
  • 80
  • 15
  • 12
  • 8
  • 8
  • 7
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 410
  • 410
  • 237
  • 215
  • 160
  • 105
  • 73
  • 72
  • 70
  • 68
  • 62
  • 57
  • 56
  • 56
  • 53
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Compensação de desequilíbrios de carga empregando conversor estático operando com modulação em largura de pulso. / A new instantaneous method for harmonics, positive and negative sequence detection for compensation of distorted currents with static converters using pulse width modulation.

Rodrigo Cutri 27 February 2004 (has links)
É cada vez maior a preocupação com a qualidade da energia elétrica tanto do ponto de vista do consumidor quanto da concessionária. Um dos grandes problemas encontrados é o desequilíbrio de correntes trifásicas devido à utilização de cargas monofásicas, bifásicas ou trifásicas desequilibradas em sistemas trifásicos de potência. Para eliminar esse desequilíbrio é necessária a identificação da parcela de corrente de seqüência negativa presente no sistema e sua eliminação. A injeção das correntes de compensação via conversores estáticos operando em PWM (Pulse Width Modulation) é uma das soluções aplicadas. Esta solução exige o cálculo em tempo real da componente instantânea de seqüência negativa, que será utilizada para a obtenção da referência de corrente do conversor. Neste trabalho, alguns dos métodos mais conhecidos para a determinação das correntes de referências são agrupados segundo suas características comuns e suas notações são uniformizadas. Estes métodos são simulados e comparados segundo suas características a partir de resultados obtidos via simulação numérica utilizando o software MATLAB (Simulink-Power System Blockset). Um novo método é proposto para a extração em tempo real da componente da corrente de seqüência negativa, apresentando um bom desempenho em comparação com os outros métodos. O desempenho de um compensador completo é verificado via simulação numérica, utilizando-se um conversor do tipo fonte de tensão operando em PWM, incluindo as malhas de controle de corrente do lado CA e da tensão no barramento CC. As metodologias do projeto do conversor (indutor CA e capacitor CC) e das malhas de controle (rastreamento da corrente CA e regulação da tensão CC) são apresentadas. / The concern with the power quality is great, not only from the consumer\'s point of view but also from the utilities point of view. One of the most common problems is the unbalanced three-phase currents due to the use of single-phase loads, two-phase loads or unbalanced three-phase loads in three-phase power systems. In order to eliminate this unbalance it is necessary to identify the negative sequence components of the load current and to eliminate it. The injection of the compensating currents by means of static converters using PWM (Pulse Width Modulation) is one possible solution. This solution needs an algorithm for the real time extraction of the negative sequence component that will be used for generating the reference current for the converter. In this work, well-known methods for determination of the reference currents are organized and explained according to their common characteristics. All the methods have their simbology unified and their performance are compared based on simulation results. A new method, faster than the existing ones, is proposed. It is fully simulated using a voltage source converter operating with PWM. Design methodologies are proposed for the converter (AC inductor, DC capacitor) and for the control loops (AC current tracking and DC voltages regulation).
72

Avaliação do impacto de sistemas fotovoltaicos conectados à rede de distribuição de baixa tensão / Evaluation of grid connected photovoltaic systems impact on low voltage electrical grid

Pinto Neto, Aimé Fleury de Carvalho 09 September 2016 (has links)
Este trabalho apresenta a avaliação dos impactos elétricos da inserção da geração distribuída de sistemas fotovoltaicos conectados à rede de distribuição em baixa tensão, com a finalidade de identificar os impactos e demonstrar que estes podem ser controlados. O estudo consistiu de uma avaliação teórica e de um estudo de caso da inserção da geração fotovoltaica considerando aspectos da qualidade de energia da rede, curva de carga resultante, vida útil de transformadores e gestão ativa da demanda. Os resultados mostraram que a inserção da geração fotovoltaica na rede de baixa tensão altera a curva de carga da unidade consumidora, mas que essas alterações podem ser controladas pela gestão ativa da demanda utilizando armazenamento de energia. Os resultados também mostraram que a geração fotovoltaica também afeta a tensão e o fator de potência da unidade consumidora, mas que essas alterações podem ser controladas pela produção de potência reativa pelo inversor. Além disso, verificou- se que a geração fotovoltaica não afetou a distorção harmônica de tensão da rede e que aumentou a vida útil do transformador. / This work presents the evaluation of grid connected photovoltaic systems\' impact on low voltage electrical grid, in order to identify the impacts and demonstrate that it can be controlled. The study consisted of a theoretical evaluation and of a case study of photovoltaic generation inclusion considering aspects of grid power quality, resulting load curve, lifespan of transformers and demand side management. The results showed that the inclusion of photovoltaic generation in low voltage network changes the load curve of the consumer unit, but these changes can be controlled by demand side management using energy storage. The results also showed that the photovoltaic generation also affects the voltage and the power factor of the consumer unit, but these changes can be controlled by the production of reactive power by the inverter. Furthermore, it was found that the photovoltaic generation does not affect the voltage harmonic distortion of the mains and it increases the lifespan of the transformer.
73

Interferência de harmônicas em equipamentos de medição de energia elétrica. / Harmonic interference in equipment for measurement of eletrical energy.

Rodrigues, José Eduardo 28 May 2009 (has links)
Este trabalho aborda a conformidade dos medidores de energia em sistemas não senoidais, na busca do aumento de qualidade no faturamento de energia elétrica. Para tanto, enfoca a medição mais justa e um melhor relacionamento entre concessionária e consumidor. As análises foram realizadas nos laboratórios da Eletropaulo, do Instituto de Eletrotécnica e Energia da Universidade de São Paulo, e no Laboratório do Centro de Estudos em Regulação e Qualidade de Energia (Enerq), USP. Trata-se de um estudo que faz parte de um projeto maior de Pesquisa e Desenvolvimento da Agência Nacional de Energia Elétrica (ANEEL). Seu objetivo foi investigar se a distorção de tensão e corrente nos medidores de faturamento de energia elétrica provoca desvios na energia medida. Pretendeu-se ainda avaliar se as harmônicas inseridas nos medidores eletromecânicos possuem maior ou menor desvio na energia medida, em comparação aos medidores eletrônicos. A metodologia utilizada incluiu levantamento de estudos de pesquisa e desenvolvimento, além de ensaios de laboratório com amostras de equipamentos de dois fabricantes nacionais. Como parâmetros para os ensaios, levantaram-se curvas, por meio de medições de cargas reais. Os resultados das medições obtidas em situações reais foram comparados com aquelas levantadas nos laboratórios. Os resultados dos ensaios laboratoriais foram analisados e comparados com os limites estabelecidos nas normas vigentes, dentre as quais, destacam-se: o Regulamento Técnico Metrológico do INMETRO e os Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional PRODIST. O presente estudo concluiu que os instrumentos ensaiados em conforme normas, quando parametrizados para não considerar a potência de distorção no cálculo de reativo, atendem os parâmetros de exatidão. Esses dados são válidos tanto para as funções de VArh quanto para Wh. / This work addresses the reliability of energy meters in nonsinusoidal systems, looking for the increase of quality in the electric energy billing. To that purpose, it focuses on a fairer metering and a better relationship between the concessionaire and consumer. The tests were carried through in the laboratories of Eletropaulo, of the Electro-Technology and Energy Institute in the University of São Paulo, and in the Laboratory of the Center of Studies in Power Quality Regulation (Enerq), USP. This study is part of a bigger project in Research and Development of the Electric Energy National Agency (Aneel). Its objective was to investigate whether the distortion of voltage and current in the electric energy billing meters had deviations in the metered energy. It was also intended to evaluate whether the inserted harmonics in the electromechanical meters have greater or minor deviation in the metered energy, in comparison to the electronic meters. The methodology used included a survey of studies, research and development of the electric sector, besides laboratory tests with two national equipment samples. As parameters for the tests, wave were formulated by means of real load metering. The results of the metering obtained in real situations were compared with those collected in the laboratories. The results of the laboratory tests were analyzed and compared with the limits established in the norms in force, amongst which one highlights: the Technical Metrological Regulation from Inmetro and the Electric Power Distribution Procedures in the National Electric System Prodist. The present study concluded the instruments analyzed under normalized conditions, when parameterized to not consider the distortion power in the calculation of reactive, meet the 60Hz frequency, within the accuracy parameters. These data are valid both for the VArh functions and the Wh.
74

Wind Energy Conversion Systems based on DFIG Technology used as Active Filters: Steady-State and Transient Analysis

Todeschini, Grazia 08 April 2010 (has links)
This thesis deals with the performance of a Wind Energy Conversion System operating as a power generator and Active Filter simultaneously. As a power generator, the Wind Energy Conversion System converts wind energy into electric energy; as an Active Filter, it sinks the harmonic currents injected by Non-Linear Loads connected at the same feeder. Three control systems are developed to ensure the described operation; a specific study regarding the compensation of the triplen harmonics is carried out; Doubly-Fed Induction Generator derating is defined; and an engineering economic analysis is performed to determine the profitability of the proposed operation. The Wind Energy Conversion System performance as generator and Active Filter has been studied for steady-state analysis, fast transients and low transients. It is concluded that the proposed control systems allow operating the Wind Energy Conversion System as power generator and harmonic compensator both during steady state and transient operation; the described operation causes power loss increase and voltage distortion that determine the choice of the component and require system derating.
75

Utilização de unidades de microgeração fotovoltaica para regulação centralizada de tensão

Godoy, Lívia Lisandro Judice January 2017 (has links)
A Geração Distribuída no Brasil tem crescido ao longo dos anos, especialmente na fonte fotovoltaica e na categoria que a ANEEL denomina microgeração distribuída, que são centrais geradoras de energia elétrica com potência instalada menor ou igual a 75 kW e conectada na rede de distribuição por meio de instalações de unidades consumidoras. Apesar dos problemas tradicionais que podem ocorrer com a inserção em larga escala, como maiores perdas e desvios de tensão, as placas fotovoltaicas, conectadas à rede de distribuição por meio de um inversor, trazem a possibilidade de controlar a tensão no ponto de conexão, manipulando-se o fator de potência de saída do inversor, controlando a potência reativa. Neste contexto, considerando o uso dos inversores inteligentes com possibilidade de envio de sinal remotamente ao operador e a possibilidade de criação de Centros de Despacho de Geração Distribuída (CDGD), este trabalho tem por objetivo propor uma metodologia de regulação de tensão centralizada utilizando unidades de microgeração fotovoltaicas, em redes de distribuição com larga inserção. A metodologia proposta utiliza o conceito de despacho de potência reativa e fluxo de potência reativa ótimo, por meio de uma abordagem centralizada da rede, utilizando-se o software OpenDSS e MatLab, equipado com Algoritmo Genético (AG) para solucionar o problema de otimização. Para avaliar o desempenho do modelo, foram feitos estudos de caso no sistema IEEE 123 barras e em uma rede real em Alegrete. Os resultados obtidos validam a abordagem proposta, demonstra a aplicabilidade e limitações em casos reais. / The distributed generation in Brazil has increased in the past years, specially in photovoltaic power generation, at the category that Brazilian Electric Regulator ANEEL classifies as "distributed micro-generation", i.e., generation units in which the active power capacity is equal or bellow 75kW and conected on distribution network by the consumers. Despite the traditional problems that might occur due to high penetration of the units, e.g., higher losses and voltage sags and swells, they are conected to the network through an inverter that can be controlled in order to provide or consume reactive power, providing voltage regulation. In that context, considering the use of intelligent inverters that can be remotely operated by a centralized utility operator, this work aims to propose a centralized voltage regulation methodology using distributed micro-generation in distribution networks. The proposed methodology uses the concept of reactive power dispatch and optimal power flow, from a centralized view of the network, using the software MatLab and OpenDSS with Genetic Algorithm to solve the optimization problem. To evaluate the model, simulations were performed with the IEEE 123 bus system and with a real distribution network from the Alegrete city, in the Brazilian state of Rio Grande do Sul. The results show the proposed is valid, despite some limitations on real cases.
76

Power-flow control and power-quality enhancement in interconnected distribution networks / Contrôle de flux de puissance et amélioration de la qualité de l'énergie dans les réseaux de distribution interconnectés

Boyra, Maialen 03 October 2012 (has links)
L’introduction massive des sources de génération distribuée est un des challenges le plus importants dans les réseaux de distribution intelligents (aussi connus comme Smartgrids). Pour augmenter le taux de pénétration des sources de génération distribuées cette thèse se projette sur un scénario futur où les réseaux de distribution seront maillés. Afin de proposer des solutions qui faciliteront une migration vers de réseaux de distribution plus maillés, les deux objectifs majeurs qu’ont été fixés pour cette thèse sont:- L’étude d’une solution capable de moduler le flux de puissance (actif et réactif indépendamment) entre deux réseaux de distribution.- Par ailleurs, la solution évaluée doit aussi être capable d’améliorer la qualité de l’énergie dans un des réseaux ou d’empêcher la propagation des perturbations d’un réseau à l’autre.Pour satisfaire le double défi de contrôler le flux de puissance et la qualité de l’énergie simultanément, cette thèse propose l’utilisation d’un Unified Power Line Conditioner (UPLC). Compte tenu des capacités exceptionnelles de l’UPLC, l’ambition principale de cette thèse réside à explorer le potentiel et l’intérêt de l’utiliser pour interconnecter deux réseaux de distribution. Il ne faut néanmoins pas oublier que l’UPLC n’est pas le seul appareil à pouvoir combiner les fonctions de contrôle de flux de puissance et d’amélioration de la qualité électrique. Il existe, également, un appareil appelé Medium Voltage Direct Current (MVDC) qui est capable de réaliser les mêmes fonctions ou similaires. Dû à l’importance de ce fait, une partie de la thèse est consacré à la comparaison entre l’UPLC et le MVDC. / Large scale penetration of distributed generation is one of the most important challenges that Smartgrids will need to deal with. Among the possible solutions to increase the amount of distributed generation, there is one that consists in meshing the existing looped (but radially operated) distribution-grid topologies. In order to migrate towards meshed and actively operated topologies, this PhD proposes:- The study a solution that is able to modulate power-flow (active and reactive powers independently) in the ties between distribution grids.- The analyzed solution must also be able to improve power-quality or to avoid propagation of power quality disturbances from one grid to the other.In order to satisfy the double challenge of controlling power-flow and power quality simultaneously, this PhD proposes the use of a Unified Power Line Conditioner (UPLC). Considering the outstanding functionalities of UPLC, the main ambition of the PhD is to explore the potential and the interest of using such an apparatus for interconnecting MV distribution grids.It must nevertheless consider that UPLC is not the only a device capable of combining these functions. A device named Medium Voltage Direct Current (MVDC) can also deal with these multiple objectives. One part of the PhD is thus committed to a comprehensive comparison between both apparatus.
77

Compensação de desequilíbrios de carga empregando conversor estático operando com modulação em largura de pulso. / A new instantaneous method for harmonics, positive and negative sequence detection for compensation of distorted currents with static converters using pulse width modulation.

Cutri, Rodrigo 27 February 2004 (has links)
É cada vez maior a preocupação com a qualidade da energia elétrica tanto do ponto de vista do consumidor quanto da concessionária. Um dos grandes problemas encontrados é o desequilíbrio de correntes trifásicas devido à utilização de cargas monofásicas, bifásicas ou trifásicas desequilibradas em sistemas trifásicos de potência. Para eliminar esse desequilíbrio é necessária a identificação da parcela de corrente de seqüência negativa presente no sistema e sua eliminação. A injeção das correntes de compensação via conversores estáticos operando em PWM (Pulse Width Modulation) é uma das soluções aplicadas. Esta solução exige o cálculo em tempo real da componente instantânea de seqüência negativa, que será utilizada para a obtenção da referência de corrente do conversor. Neste trabalho, alguns dos métodos mais conhecidos para a determinação das correntes de referências são agrupados segundo suas características comuns e suas notações são uniformizadas. Estes métodos são simulados e comparados segundo suas características a partir de resultados obtidos via simulação numérica utilizando o software MATLAB (Simulink-Power System Blockset). Um novo método é proposto para a extração em tempo real da componente da corrente de seqüência negativa, apresentando um bom desempenho em comparação com os outros métodos. O desempenho de um compensador completo é verificado via simulação numérica, utilizando-se um conversor do tipo fonte de tensão operando em PWM, incluindo as malhas de controle de corrente do lado CA e da tensão no barramento CC. As metodologias do projeto do conversor (indutor CA e capacitor CC) e das malhas de controle (rastreamento da corrente CA e regulação da tensão CC) são apresentadas. / The concern with the power quality is great, not only from the consumer\'s point of view but also from the utilities point of view. One of the most common problems is the unbalanced three-phase currents due to the use of single-phase loads, two-phase loads or unbalanced three-phase loads in three-phase power systems. In order to eliminate this unbalance it is necessary to identify the negative sequence components of the load current and to eliminate it. The injection of the compensating currents by means of static converters using PWM (Pulse Width Modulation) is one possible solution. This solution needs an algorithm for the real time extraction of the negative sequence component that will be used for generating the reference current for the converter. In this work, well-known methods for determination of the reference currents are organized and explained according to their common characteristics. All the methods have their simbology unified and their performance are compared based on simulation results. A new method, faster than the existing ones, is proposed. It is fully simulated using a voltage source converter operating with PWM. Design methodologies are proposed for the converter (AC inductor, DC capacitor) and for the control loops (AC current tracking and DC voltages regulation).
78

Transitórios originados pelo chaveamento de bancos de capacitores da concessionária em um sistema elétrico de distribuição / Transients resulting from the switching of the utility capacitor banks in the electrical distribution systems

Santos, Cláudio José dos 04 February 2000 (has links)
A qualidade da energia elétrica tem sido objeto constante de estudos, pois problemas inerentes a ela podem trazer grandes prejuízos econômicos, principalmente em processos industriais. Dentre os vários fatores que afetam a qualidade da energia elétrica, destacamos aqueles relacionados com os transitórios, originados pelo chaveamento de banco de capacitares nas redes elétricas de distribuição primária. Neste trabalho, além das características dos transitórios provenientes da energização de bancos de capacitares da concessionária, são analisados fatores que influenciam em suas intensidades. As condições sob as quais estes transitórios são atenuados foram investigadas. Além disto, é feita uma análise espectral das ondas de corrente e tensão, permitindo que sejam revelados os componentes harmônicos que podem afetar o funcionamento de equipamentos de controle, proteção e cargas sensíveis da indústria. Um circuito que representa um sistema real de distribuição, 13,8 kV, da concessionária CPFL (Cia Paulista de Força e Luz) foi simulado através do ATP (Alternative Transients Program). / The quality of electric power has been a constant topic of study, because inherent problems to it can bring great economic losses, mainly in industrial processes. Among the several factors that atfect power quality, those related to the transients originated by capacitar bank switching in the primary distribution systems must be highlighted. In this work, the characteristics of the transients resulting from the switching of the utility capacitor banks are analyzed, as well as factors that influence their intensities. The conditions under which these effects are mitigated was investigated. In addition, a spectral analysis of the current and voltage waves is made. This procedure can reveal the harmonic components that can affect the operation of control and protection equipment, as well as sensitive Ioads of the industry. A circuit that represents a real distribution system, 13.8 kV, from CPFL (Cia Paulista de Força e Luz) utility, was simulated through the software ATP (Alternative Transients Program).
79

Método de extração em tempo real de seqüência positiva, negativa e/ou harmônicos. / Real time methods for positive, negative sequence and/or harmonics extraction.

Cutri, Rodrigo 14 December 2007 (has links)
Harmônicos e desequilíbrios podem causar uma série de problemas a equipamentos conectados a rede elétrica. Este trabalho propõe um método de extração em tempo real das componentes de seqüência positiva, negativa e/ou harmônicos que não requer transformações de coordenadas ou filtragem de sinais. O método proposto é verificado via simulação numérica e implementado experimentalmente em um DSP. Como exemplos de aplicação apresentam-se: a simulação de um Filtro Ativo de Potência utilizando-se um conversor do tipo fonte de tensão operando em PWM e um Relé de Seqüência Negativa. / Harmonics and unbalances cause several problems to equipments connected to AC mains. This work proposes a real time method to obtain the positive and negative sequence components and/or harmonics that requires no coordinate transformation neither signal filtering. Numerical simulation and experimental results are shown to validate the proposed method. As examples of application an Active Power Filter using a voltage source converter operating with PWM and an Negative Sequence Power Relay are presented.
80

Método de extração em tempo real de seqüência positiva, negativa e/ou harmônicos. / Real time methods for positive, negative sequence and/or harmonics extraction.

Rodrigo Cutri 14 December 2007 (has links)
Harmônicos e desequilíbrios podem causar uma série de problemas a equipamentos conectados a rede elétrica. Este trabalho propõe um método de extração em tempo real das componentes de seqüência positiva, negativa e/ou harmônicos que não requer transformações de coordenadas ou filtragem de sinais. O método proposto é verificado via simulação numérica e implementado experimentalmente em um DSP. Como exemplos de aplicação apresentam-se: a simulação de um Filtro Ativo de Potência utilizando-se um conversor do tipo fonte de tensão operando em PWM e um Relé de Seqüência Negativa. / Harmonics and unbalances cause several problems to equipments connected to AC mains. This work proposes a real time method to obtain the positive and negative sequence components and/or harmonics that requires no coordinate transformation neither signal filtering. Numerical simulation and experimental results are shown to validate the proposed method. As examples of application an Active Power Filter using a voltage source converter operating with PWM and an Negative Sequence Power Relay are presented.

Page generated in 0.0385 seconds