• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analyse et commandes des convertisseurs multi-niveaux pour un générateur photovoltaïque connecté au réseau électrique / Analysis and control of multilevel converters for a grid connected photovoltaic generator

Mahamat, Chabakata 19 June 2018 (has links)
Ces travaux de thèse préparés au laboratoire SATIE, s’inscrivent dans la promotion de l’énergie solaire photovoltaïque (PV). Dans ces travaux, nous nous intéressons particulièrement au dimensionnement et au contrôle-commande du système PV connecté au réseau dans un contexte d’utilisation au Tchad où l’on doit tenir compte des problématiques du coût, du rendement, de fiabilité du système et de la qualité de l’énergie. Le réseau considéré est un réseau basse tension BT (220 V) avec une fréquence égale à 50 Hz mais susceptible de varier, auquel on injecte une puissance de 5,2 kW. Une méthode de dimensionnement des éléments passifs du filtre, a été préposée en premier lieu. Dans le but de réduire le coût de fabrication et le volume du filtre passif, une technique de fragmentation en plusieurs petites inductances en série a été adoptée. Cette technique optimise le volume et le coût du système PV classique. Ensuite, nous avons proposé une nouvelle architecture du système PV connecté au réseau utilisant un onduleur multi-niveaux. L’adaptation de cet onduleur à structure innovante a permis de réduire le coût de fabrication du filtre passif d’environ 40 % par rapport au système classique optimisé, tout en augmentant le rendement. Enfin, une commande PQ découplée, utilisant une boucle à verrouillage de phase PLL pour synchronisation, a été conçue et appliquée aux deux systèmes PV. Elle est bien adaptée au système avec onduleur multi-niveaux. / This PhD work, prepared at SATIE laboratory, is part of the promotion of solar photovoltaic (PV) energy. In this work, we are particularly interested in design and control of the grid-connected PV system in a context of use in Chad where cost, reliability, efficiency, and energy quality issues of the system should be taken into account. The considered grid is a low voltage grid (220 V) with a frequency equal to fifty hertz (50 Hz) but likely to vary, in which a power of five point two ( 5.2 kW) is injected. A design method of the filter passive to reduce the filter elements is proposed firstly. In order to reduce manufacturing cost and volume of the passive filter, we apply a technique consisting of dividing each inductance value and making it in several small inductances in series. This technique optimizes the conventional PV system. Then, we proposed a new grid-connected PV system architecture using a multi-level inverter. The adaptation of this innovative structure has reduced the manufacturing cost of passive filter by nearly 40 % compared to the classical optimized system. Finally, a decoupled PQ control, using a phase locked loop for sysnchronization, has been designed and applied for both systems. It is well adapted to the system with multilevel inverter.
2

D-Q Frame Impedance Based Small-signal Stability Analysis of PV Inverters in Distribution Grids

Tang, Ye 18 January 2021 (has links)
With development of renewable energies worldwide, power system is seeing higher penetration of Utility-scale photovoltaic (PV) farms at distributed level as well as transmission level. Power electronics converters present negative incremental impedance characteristics at their input while under regulated output control, which brings in the possibility of system instability. Recent evidence suggests that large-scale penetration of PV inverters increases the probability of instability. While IEEE standard 1547 newest version requires PV inverters to have reactive power control, there have been few investigations into the small-signal stability impact of PV inverters on distribution systems especially with reactive power control. In addition, the existing studies either use the conventional way of state space equations and eigenvalues or use time-domain simulation methodology, which are based on the assumptions that detailed models of the grid and the PV inverters are accessible. Different from the previous literatures, this research employs Generalized Nyquist Criterion (GNC) method based on measured impedances in d-q frames at connection interfaces. GNC method has the advantage that interconnection stability can be judged without knowing the grid and PV generator model details. This work first demonstrates the advantage of volt-var droop mode control among all different local reactive power control modes for PV inverters in the aspects of static impact on grid voltage profiles and power loss in a 12kV test-bed distribution system. Then it is discovered that d-q frame impedance of PV inverter under volt-var droop mode control shows a significant difference from other reactive power control modes. The d-q frame impedance derived from the small-signal model of PV generator is validated by both MATLAB simulation results and hardware experiments. Based on the d-q frame impedances, GNC is utilized to analyze the stability connection of a single PV farm and multiple PVs into the grid. GNC stability assessment results match with time-domain simulations and reveal the stability problem related to volt-var droop mode control. Furthermore, considering the unbalance of the distribution system, a new impedance model in d-q frame is proposed to capture both the dynamics of PV inverter operating in unbalanced points and the dynamics of three-phase unbalanced grid. The new impedance model is a combination of positive-negative sequence impedance and conventional d-q frame impedance. A procedure is designed for the measurement of the extended d-q frame impedance and the GNC application to predict small-signal stability of the unbalanced grid, which are justified by both time domain simulation and hardware experiments. / Doctor of Philosophy / To overcome the limited fossil fuel reserve on the earth and global warming, renewable energies become more and more popular worldwide. Centralized thermal power generators in the transmission system are gradually being replaced by distributed energy resources (DER) which are connection to the distribution system, bringing more challenges to the safe and stable operation of the power system. This work focuses on the small-signal stability impact of photovoltaic (PV) generators in the distribution system, which basically analyzes into whether the connection of PV generator to the distribution system will end up in an expected steady operation state with high resistance to any relatively small disturbances. The stability assessment tool is based on impedance measurement which treats both sides as black boxes and bridges the information gap between Utility operators and PV generator vendors. A major finding of this work is that while PV generators in the distribution system help to provide grid-support functions of voltage regulation, they may cause voltage small-signal stability problems due to the high grid impedance, which is worse if more PV inverters are put in parallel. Even PV farms connected to different branches of the complicated radial distribution system may have interactions with each other. So the design of control strategy and parameters of PV generator should consider the impact of other PV generators. GNC method based on impedances measurement is feasible and accurate for stability assessment of a distribution system with multiple PV farms. The impedance based method is upgraded and extended to be applied for the connection of power electronics devices to the three-phase unbalanced distribution systems.

Page generated in 0.1017 seconds