• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 3
  • 1
  • 1
  • Tagged with
  • 26
  • 26
  • 14
  • 12
  • 12
  • 10
  • 10
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Array combination for parallel imaging in Magnetic Resonance Imaging

Spence, Dan Kenrick 17 September 2007 (has links)
In Magnetic Resonance Imaging, the time required to generate an image is proportional to the number of steps used to encode the spatial information. In rapid imaging, an array of coil elements and receivers are used to reduce the number of encoding steps required to generate an image. This is done using knowledge of the spatial sensitivity of the array and receiver channels. Recently, these arrays have begun to include a large number of coil elements. Ideally, each coil element would have its own receiver channel to acquire the image data. In practice, this is not always possible due to economic or other constraints. In this dissertation, methods are explored to combine a large array to a limited number of receivers so as to optimize the performance for parallel imaging; this dissertation focuses on SENSE in particular. Simple combinations that represent larger coils that might be constructed are discussed. More complex solutions form current sheets. One solution uses Roemer'€™s method to optimize image SNR at a set of points. In this dissertation, Roemer's solution is generalized to give the weighting coefficients that optimize SNR over regions. Also, solutions fitted to ideal profiles that minimize noise amplification are shown. These fitted profiles can allow the SENSE algorithm to function at optimal reduction factors. Finally, a description of how to build the combiner in hardware is discussed.
2

Application of Parallel Imaging to Murine Magnetic Resonance Imaging

Chang, Chieh-Wei 1980- 14 March 2013 (has links)
The use of parallel imaging techniques for image acceleration is now common in clinical magnetic resonance imaging (MRI). There has been limited work, however, in translating the parallel imaging techniques to routine animal imaging. This dissertation describes foundational level work to enable parallel imaging of mice on a 4.7 Tesla/40 cm bore research scanner. Reducing the size of the hardware setup associated with typical parallel imaging was an integral part of achieving the work, as animal scanners are typically small-bore systems. To that end, an array element design is described that inherently decouples from a homogenous transmit field, potentially allowing for elimination of typically necessary active detuning switches. The unbalanced feed of this "dual-plane pair" element also eliminates the need for baluns in this case. The use of the element design in a 10-channel adjustable array coil for mouse imaging is presented, styled as a human cardiac top-bottom half-rack design. The design and construction of the homogenous transmit birdcage coil used is also described, one of the necessary components to eliminating the active detuning networks on the array elements. In addition, the design of a compact, modular multi-channel isolation preamplifier board is described, removing the preamplifiers from the elements and saving space in the bore. Several additions/improvements to existing laboratory infrastructure needed for parallel imaging of live mice are also described, including readying an animal preparation area and developing the ability to maintain isoflurane anesthesia delivery during scanning. In addition, the ability to trigger the MRI scanner to the ECG and respiratory signals from the mouse in order to achieve images free from physiological motion artifacts is described. The imaging results from the compact 10-channel mouse array coils are presented, and the challenges associated with the work are described, including difficulty achieving sample-loss dominance and signal-to-noise ratio (SNR) limitations. In conclusion, in vivo imaging of mice with cardiac and respiratory gating has been demonstrated. Compact array coils tailored for mice have been studied and potential future work and design improvements for our lab in this area are discussed.
3

Efficient Algorithms for Parallel Excitation and Parallel Imaging with Large Arrays

Feng, Shuo 16 December 2013 (has links)
During the past two decades, techniques and devices were developed to transmit and receive signals with a phased array instead of a single coil in the MRI (Magnetic Resonance Imaging) system. The two techniques to simultaneously transmit and receive RF signals using phased arrays are called parallel excitation (pTx) and parallel imaging (PI), respectively. These two techniques lead to shorter transmit pulses for higher imaging quality and faster data acquisition correspondingly. This dissertation focuses on improving the efficiency of the pTx pulse design and the PI reconstruction in MRI. Both PI and pTx benefit from the increased number of elements of the array. However, efficiency concerns may arise which include: (1) In PI, the computation cost of the reconstructions and the achievable acceleration factors and (2) in pTx, the pulse design speed and memory cost. The work presented in this dissertation addresses these issues. First, a correlation based channel reduction algorithm is developed to reduce the computation cost of PI reconstruction. In conventional k-domain methods, the individual channel data is reconstructed via linear interpolation of the neighbourhood data from all channels. In this proposed algorithm, we choose only a subset of the channels based on the spatial correlation. The results have shown that the computation cost can be significantly reduced with similar or higher reconstruction accuracy. Then, a new parallel imaging method named parallel imaging using localized receive arrays with Sinc interpolation(PILARS) is proposed to improve the actual acceleration factor and to reduce the computation cost. It employs the local support of individual coils and pre-determines the magnitude of the reconstruction coefficients. Thus, it requires much less auto-calibration signals (ACS) data and achieves higher acceleration factors. The results show that this method can increase the acceleration factor and the reconstruction speed while achieving the same level of reconstruction quality. Finally, a fast pTx pulse design method is proposed to accelerate the design speed. This method is based on the spatial domain pulse design method and can be used to accelerate similar methods. We substitute the two computational expensive matrix- vector multiplications in the conjugate gradient (CG) solver with gridding and fast Fourier transform (FFT). Theoretical and simulation results have shown that the design speed can be improved by 10 times. Meanwhile, the memory cost is reduced by 103 times. This breaks the memory burden of implementing pulse designs on GPU which enables further accelerations.
4

On optimality and efficiency of parallel magnetic resonance imaging reconstruction: challenges and solutions

Nana, Roger 12 November 2008 (has links)
Imaging speed is an important issue in magnetic resonance imaging (MRI), as subject motion during image acquisition is liable to produce artifacts in the image. However, the speed at which data can be collected in conventional MRI is fundamentally limited by physical and physiological constraints. Parallel MRI is a technique that utilizes multiple receiver coils to increase the imaging speed beyond previous limits by reducing the amount of acquired data without degrading the image quality. In order to remove the image aliasing due to k-space undersampling, parallel MRI reconstructions invert the encoding matrix that describes the net effect of the magnetic field gradient encoding and the coil sensitivity profiles. The accuracy, stability, and efficiency of a matrix inversion strategy largely dictate the quality of the reconstructed image. This thesis addresses five specific issues pertaining to this linear inverse problem with practical solutions to improve clinical and research applications. First, for reconstruction algorithms adopting a k-space interpolation approach to the linear inverse problem, two methods are introduced that automatically select the optimal k-space subset samples participating in the synthesis of a missing datum, guaranteeing an optimal compromise between accuracy and stability, i.e. the best balance between artifacts and signal-to-noise ratio (SNR). While the former is based on cross-validation re-sampling technique, the second utilizes a newly introduced data consistency error (DCE) metric that exploits the shift invariance property of the reconstruction kernel to provide a goodness measure of k-space interpolation in parallel MRI. Additionally, the utility of DCE as a metric for characterizing and comparing reconstruction methods is demonstrated. Second, a DCE-based strategy is introduced to improve reconstruction efficiency in real time parallel dynamic MRI. Third, an efficient and reliable reconstruction method that operates on gridded k-space for parallel MRI using non-Cartesian trajectories is introduced with a significant computational gain for applications involving repetitive measurements. Finally, a pulse sequence that combines parallel MRI and multi-echo strategy is introduced for improving SNR and reducing the geometric distortion in diffusion tensor imaging. In addition, the sequence inherently provides a T2 map, complementing information that can be useful for some applications.
5

Reliable Use of Acquired and Simulated Signal Databases to Reduce MRI Acquisition Time

Pierre, Eric Y. 02 September 2014 (has links)
No description available.
6

The Influence of the Reference Measurement in MRI Image Reconstruction Using Sensitivity Encoding (SENSE)

Öhman, Tuva January 2006 (has links)
<p>The use of MRI for patient examinations has constantly increased as technical development has lead to faster image acquisitions and higher image quality. Nevertheless, an MR-examination still takes relatively long time and yet another way of speeding up the process is to employ parallel imaging. In this thesis, one of these parallel imaging techniques, called SENSE, is described and examined more closely.</p><p>When SENSE is employed, the number of spatial encoding steps can be reduced thanks to the use of several receiving coils. A reduction of the number of phase encoding steps not only leads to faster image acquisition, but also to superimposed pixel values in image space. In order to be able to separate the aliased pixels, knowledge about the spatial sensitivity of the coils is required.</p><p>There are several different alternatives to how and when information about the sensitivities of the coils should be collected, but in this thesis, focus is on the method of performing a reference measurement before the actual scan. The reference measurement consists of a fast, low-resolution sequence which either is collected with both the body coil and the parallel imaging coil or only with the parallel imaging coil. A comparison of these two methods by simulations in program written MATLAB leads to the conclusion that even if the scan time of the reference measurement is doubled it seems like there are numerous advantages of also collecting data with the body coil:</p><p>• the images are more homogeneous which facilitates the establishment of a diagnose</p><p>• the noise levels in the reconstructed images are somewhat lower</p><p>• images collected with a reduced sampling density show better agreement with those collected without reduction.</p><p>Furthermore, it is shown that the reference measurement preferably should be a 3D sequence covering all the volume of interest. If a 2D sequence is used it is absolutely necessary that it can be performed in any plane and it has to be repeated for every plane that is imaged.</p>
7

The Influence of the Reference Measurement in MRI Image Reconstruction Using Sensitivity Encoding (SENSE)

Öhman, Tuva January 2006 (has links)
The use of MRI for patient examinations has constantly increased as technical development has lead to faster image acquisitions and higher image quality. Nevertheless, an MR-examination still takes relatively long time and yet another way of speeding up the process is to employ parallel imaging. In this thesis, one of these parallel imaging techniques, called SENSE, is described and examined more closely. When SENSE is employed, the number of spatial encoding steps can be reduced thanks to the use of several receiving coils. A reduction of the number of phase encoding steps not only leads to faster image acquisition, but also to superimposed pixel values in image space. In order to be able to separate the aliased pixels, knowledge about the spatial sensitivity of the coils is required. There are several different alternatives to how and when information about the sensitivities of the coils should be collected, but in this thesis, focus is on the method of performing a reference measurement before the actual scan. The reference measurement consists of a fast, low-resolution sequence which either is collected with both the body coil and the parallel imaging coil or only with the parallel imaging coil. A comparison of these two methods by simulations in program written MATLAB leads to the conclusion that even if the scan time of the reference measurement is doubled it seems like there are numerous advantages of also collecting data with the body coil: • the images are more homogeneous which facilitates the establishment of a diagnose • the noise levels in the reconstructed images are somewhat lower • images collected with a reduced sampling density show better agreement with those collected without reduction. Furthermore, it is shown that the reference measurement preferably should be a 3D sequence covering all the volume of interest. If a 2D sequence is used it is absolutely necessary that it can be performed in any plane and it has to be repeated for every plane that is imaged.
8

Highly Parallel Magnetic Resonance Imaging with a Fourth Gradient Channel for Compensation of RF Phase Patterns

Bosshard, John 1983- 14 March 2013 (has links)
A fourth gradient channel was implemented to provide slice dependent RF coil phase compensation for arrays in dual-sided or "sandwich" configurations. The use of highly parallel arrays for single echo acquisition magnetic resonance imaging allows both highly accelerated imaging and capture of dynamic and single shot events otherwise inaccessible to MRI. When using RF coils with dimensions on the order of the voxel size, the array coil element phase patterns adversely affect image acquisition, requiring correction. This has previously been accomplished using a pulse of the gradient coil, imparting a linear phase gradient across the sample opposite of that due to the RF coil elements. However, the phase gradient due to the coil elements reverses on opposite sides of the coils, preventing gradient-based phase compensation with sandwich arrays. To utilize such arrays, which extend the imaging field of view of this technique, a fourth gradient channel and coil were implemented to simultaneously provide phase compensation of opposite magnitude to the lower and upper regions of a sample, imparting opposite phase gradients to compensate for the opposite RF coil phase patterns of the arrays. The fourth gradient coil was designed using a target field approach and constructed using printed circuit boards. This coil was integrated with an RF excitation coil, dual-sided receive array, and sample loading platform to form a single imaging probe capable of both ultra-fast and high resolution magnetic resonance imaging. By employing the gradient coil, this probe was shown to simultaneously provide improved phase compensation throughout a sample, enabling simultaneous SEA imaging using arrays placed below and above a sample. The fourth gradient coil also improves the acquisition efficiency of highly accelerated imaging using both arrays for receive. The same imaging probe was shown to facilitate accelerated MR microscopy over the field of view of the entire array with no changes to the hardware configuration. The spatio-temporal imaging capabilities of this system were explored with magnetic resonance elastography.
9

Magnetic resonance imaging with ultrashort echo time as a substitute for X-ray computed tomography

Johansson, Adam January 2014 (has links)
Radiotherapy dose calculations have evolved from simple factor based methods performed with pen and paper, into computationally intensive simulations based on Monte Carlo theory and energy deposition kernel convolution. Similarly, in the field of positron emission tomography (PET), attenuation correction, which was originally omitted entirely, is now a crucial component of any PET reconstruction algorithm. Today, both of these applications – radiotherapy and PET – derive their needed in-tissue radiation attenuation coefficients from images acquired with X-ray computed tomography (CT). Since X-ray images are themselves acquired using ionizing radiation, the intensity at a point in an image will reflect the radiation interaction properties of the tissue located at that point. Magnetic resonance imaging (MRI), on the other hand, does not use ionizing radiation. Instead MRI make use of the net transverse magnetization resulting from the spin polarization of hydrogen nuclei. MR image contrast can be varied to a greater extent than CT and the soft tissue contrast is, for most MR sequences, superior to that of CT. Therefore, for many cases, MR images provide a considerable advantage over CT when identifying or delineating tumors or other diseased tissues. For this reason, there is an interest to replace CT with MRI for a great number of diagnostic and therapeutic workflows. Also, replacing CT with MRI would reduce the exposure to ionizing radiation experienced by patients and, by extension, reduce the associated risk to induce cancer. In part MRI has already replaced CT, but for radiotherapy dose calculations and PET attenuation correction, CT examinations are still necessary in clinical practice. One of the reasons is that the net transverse magnetization imaged in MRI cannot be converted into attenuation coefficients for ionizing radiation in a straightforward way. More specifically, regions with similar appearance in magnetic resonance (MR) images, such as bone and air pockets, are found at different ends of the spectrum of attenuation coefficients present in the human body. In a CT image, bone will appear bright white and air as black corresponding to high and no attenuation, respectively. In an MR image, bone and air both appear dark due to the lack of net transverse magnetization. The weak net transverse magnetization of bone is a result of low hydrogen density and rapid transverse relaxation. A particular category of MRI sequences with so-called ultrashort echo time (UTE) can sample the MRI signal from bone before it is lost due to transverse relaxation. Thus, UTE sequences permit bone to be imaged with MRI albeit with weak intensity and poor resolution. Imaging with UTE in combination with careful image analysis can permit ionizing-radiation attenuation-maps to be derived from MR images. This dissertation and appended articles present a procedure for this very purpose. However, as attenuation coefficients are radiation-quality dependent the output of the method is a Hounsfield unit map, i.e. a substitute for a CT image. It can be converted into an attenuation map using conventional clinical procedure. Obviating the use of CT would reduce the number of examinations that patients have to endure during preparation for radiotherapy. It would also permit PET attenuation correction to be performed on images from the new imaging modality that combines PET and MRI in one scanner – PET/MR.
10

Magnetic resonance angiography with compressed sensing: an evaluation of moyamoya disease / 圧縮センシングを用いたMRアンギオグラフィによるもやもや病の検討

Yamamoto, Takayuki 26 March 2018 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(医学) / 甲第21001号 / 医博第4347号 / 新制||医||1027(附属図書館) / 京都大学大学院医学研究科医学専攻 / (主査)教授 溝脇 尚志, 教授 辻川 明孝, 教授 小泉 昭夫 / 学位規則第4条第1項該当 / Doctor of Medical Science / Kyoto University / DFAM

Page generated in 0.0707 seconds