• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Filtração de gases: Estudo do fenômeno da limpeza por blocos.

Tieni, Érica Flávia 22 March 2005 (has links)
Made available in DSpace on 2016-06-02T19:56:52Z (GMT). No. of bitstreams: 1 DissEFT.pdf: 2733482 bytes, checksum: 3430708d390441c11e75764bdef622d0 (MD5) Previous issue date: 2005-03-22 / Financiadora de Estudos e Projetos / This work had for purpose to study the phenomenon of patchy cleaning in the operation of the gas filtration, which happens when there is the incomplete regeneration of the filter. A parameter very used to characterize this phenomenon it is the cleaned fraction, which is defined as the ratio between the cleaned areas to the total area of filtration. In order to investigate the patchy cleaning behavior, filtration experiments were accomplished, with the intention to study the action of the cleaning in the fabric of polyester, for different combinations of experimental conditions. To characterize the cleaning for blocks, it has been developed a methodology that includes imagining of the blocks and computer program that analyzes these images of the cake at the end of each cleaning cycle. Using these images it was possible to mark the areas removed with the aim to obtain the size of the removed blocks. The general results showed that: for the maximum pressure drop of 1960 Pa, the fabric presented saturation behavior starting from the second filtration cycle, and for the maximum pressure drop 2939 and 3919 Pa, starting from the fourth filtration cycle. Unlike what was expected, the maximum cleaning velocity was not the one that gives the maximum removal of the cake. The residual pressure drop showed relationship with the distribution of the sizes of the removed blocks. Concerning the quantification of the removed blocks, the removed total area did not present defined behavior with the number of cycles. The largest percentage of the removed blocks presented size between 0,1 e 1 cm2. The area fractions and mass fractions removed presented curves with similar behavior. Besides, the two fractions presented very close values to each other, showing that the technique proposed in this work of quantification of the size of the removed areas presented quite satisfactory results. / Este trabalho teve por objetivo estudar o fenômeno da limpeza por blocos na operação da filtração de gases, que acontece quando há a regeneração incompleta do filtro. Um parâmetro muito utilizado para caracterizar a limpeza por blocos é a fração de limpeza, que pode ser dada tanto como fração de área removida como fração de massa removida. Desta maneira, para investigar esse fenômeno, ensaios de filtração foram realizados, com o intuito de verificar o desempenho da limpeza no tecido de poliéster, para diferentes combinações de condições experimentais. Para caracterizar a limpeza por blocos, desenvolveu-se uma metodologia que consistiu em fotografar a torta ao final de cada limpeza, de modo a obter imagens das tortas parcialmente destacadas. A partir destas imagens, foi possível marcar as áreas removidas em um programa de análise de imagens. Os resultados gerais mostraram que: para a perda de carga máxima de 1960 Pa, o tecido apresentou comportamento de saturação a partir do segundo ciclo de filtração, e para as perdas de carga máxima de 2939 e 3919 Pa, a partir do quarto ciclo de filtração. Ao contrário do que se imaginava, a maior velocidade de limpeza não foi a que apresentou maior eficiência de remoção. A perda de carga residual apresentou íntima relação com a distribuição do tamanho dos pedaços removidos. Com relação ao fenômeno da limpeza por blocos, a área total removida não apresentou comportamento definido com o número de ciclos. Já a maior porcentagem dos pedaços removidos foi relativa aos pedaços com tamanho entre 0,1 e 1 cm2. A comparação entre as frações de massa e de área removida mostrou que o método proposto para quantificar a área removida na operação da filtração apresentou resultados bastante satisfatórios.
2

Comportamento da filtração de gases em meios filtrantes de celulose.

Osório, Vanessa Moreira 15 September 2006 (has links)
Made available in DSpace on 2016-06-02T19:56:28Z (GMT). No. of bitstreams: 1 DissVMO.pdf: 4943436 bytes, checksum: 2211c87e5be0a702fd92e5103e1a5e1a (MD5) Previous issue date: 2006-09-15 / Universidade Federal de Sao Carlos / The present work aims to evaluate, through filtration process and cake detachment, the behavior of two cellulose fiber filtering media with different air permeability values. The powder material used was phosphatic concentrated rock of density 2,99 g/cm3 and its average volumetric diameter of 8,34 µm. The equipment used was constituted of a circular filter, powder feeder which controlled the massic flow and humidity by a microcomputer and a system for control and acquisition of data. The filtering media used were cellulose fibers, Rad More and Rad Plus, supplied by Alhstrom Louveira. The work was accomplished by a successive sequence of filtration and cleaning during 100 filtration cycles using cellulose filtering media. The technique employed for cake removal was reverse air flow. In the experimental procedure, filtration velocity of 10 cm/s was used for maximum pressure drop of 200 mmH2O, and 5 cm/s for maximum pressure drop of 100 mmH2O. Two cleaning velocity were employed for cake removal, 18 and 13 cm/s. The results showed that the filtering media Rad Plus, when submitted to filtration velocity of 10 cm/s and cleaning velocity of 18 cm/s, obtained the best operational condition, as it presented lower values of residual pressure drop for a larger mass retained during the 100 filtration cycles. For different filtration velocity, 10 and 5 cm/s, the filtering media Rad Plus, more porous and more permeable, the amount of particle mass removed was larger than for the filtering media Rad Plus applying cleaning velocity of 18cm/s as the removal force for this cleaning velocity could remove the particles retained in the fibers. For filtration velocity of 5 cm/s, a lower cleaning velocity, 13 cm/s, was enough to remove larger amount of particles, when compared with the filtering media Rad Plus in the same experimental conditions. / O objetivo deste trabalho é avaliar, através do processo de filtração e de remoção das tortas, o comportamento de dois meios filtrantes de fibras de celulose de diferentes permeabilidades. O material particulado utilizado foi o concentrado fosfático de densidade 2,99 g/cm3 e diâmetro médio de partícula de 8,34 µm. O equipamento utilizado era constituído de um filtro circular, alimentador de pó com a vazão mássica e umidade controlada, um microcomputador e um sistema para controle e aquisição de dados. Os meios filtrantes utilizados foram de fibras de celulose, Rad Mais e Rad Plus, fornecidos pela Empresa Alhstrom Louveira. O trabalho foi realizado por uma seqüência sucessiva de filtração e de limpeza durante 100 ciclos de filtração, em meios filtrantes de celulose, sendo que o método de limpeza utilizado, para a remoção das tortas, foi o fluxo de ar reverso. No procedimento experimental de filtração foram utilizadas velocidades de filtração de 10 cm/s, para queda de pressão máxima de 200 mmH2O, e de 5 cm/s, para queda de pressão de 100 mmH2O. Para a remoção das tortas foram utilizadas duas velocidades de limpeza, de 18 cm/s e 13 cm/s. Os resultados mostraram que o meio filtrante Rad Mais, quando submetido à velocidade de filtração de 10 cm/s e velocidade de limpeza de 18 cm/s, obteve a melhor condição operacional, porque apresentou menor perda de carga residual para uma maior massa retida durante os 100 ciclos de filtração. Para as duas velocidades de filtração de 10 cm/s e 5 cm/s, o meio filtrante Rad Mais, mais poroso e mais permeável, a quantidade de massa de partículas removida foi maior quando comparado com o meio filtrante Rad Plus com Vl de 18cm/s, porque a força de remoção para a Vl de 18 cm/s conseguiu remover as partículas retidas nas fibras. Já para a Vf de 5 cm/s, uma menor velocidade de limpeza, Vl de 13 cm/s foi suficiente para remover maior quantidade de partículas, quando comparada com o meio filtrante Rad Plus nas mesmas condições experimentais.

Page generated in 0.0949 seconds