Spelling suggestions: "subject:"period:focusing"" "subject:"period:focusing""
1 |
Development of a variable-temperature ion mobility/ time-of-flight mass spectrometer for separation of electronic isomersVerbeck, Guido Fridolin 29 August 2005 (has links)
The construction of a liquid nitrogen-cooled ion mobility spectrometer coupled
with time-of-flight mass spectrometry was implemented to demonstrate the ability to
discriminate between electronic isomers. Ion mobility allows for the separation of ions
based on differing cross-sections-to-charge ratio. This allows for the possible
discrimination of species with same mass if the ions differ by cross-section. Time-offlight
mass spectrometry was added to mass identify the separated peak for proper
identification.
A liquid nitrogen-cooled mobility cell was employed for a two-fold purpose.
First, the low temperatures increase the peak resolution to aid in resolving the separated
ions. This is necessary when isomers may have similar cross-sections. Second, low
temperature shortens the mean free path and decreases the neutral buffer gas speeds
allowing for more interactions between the ions and the drift gas. Kr2+ study was
performed to verify instrument performance.
The variable-temperature ion mobility spectrometer was utilized to separate the
distonic and conventional ion forms of CH3OH, CH3F, and CH3NH2 and to discriminate
between the keto and enol forms of the acetone radical cation. Density functional theory
and ab initio calculations were employed to aid in proper identification of separating
isomers. Monte Carlo integration tools were also developed to predict ion cross-section
and resolution within a buffer gas.
|
2 |
High Resolution Ion Mobility Spectrometry with Increased Ion Transmission: Exploring the Analytical Utility of Periodic-Focusing DC Ion Guide Drift CellsBlase, Ryan Christopher 2010 December 1900 (has links)
Drift tube ion mobility spectrometry (IMS) is a powerful, post-ionization separation that yields structural information of ions through an ion-neutral collision cross section. The ion-neutral collision cross section is governed by the collision frequency of the ion with the neutral drift gas. Consequently, ions of different size will have different collision frequencies with the gas and be separated in the drift cell. A significant challenge for IMS, however, is to separate ions with very similar collision cross sections, requiring higher resolution ion mobility spectrometers. Resolution in IMS is of utmost importance for the separation of complex mixtures, e.g. crude oil samples, proteolytic digests, positional isomers, and ion conformers. However, most methods employed to increase mobility resolution significantly decrease ion transmission through the mobility device.
Herein, a periodic-focusing DC ion guide drift cell (PDC IG) is presented to display its potential capabilities for higher mobility resolution with increased ion transmission. The PDC IG utilizes unique electrode geometry compared to the conventional uniform field electrode design. Electrode geometry can be defined by the electrode inner diameter (d), thickness (t), and spacing (s). Specifically, the ratio of d : t : s is equal to, or very near, 1:1:1. The PDC IG electrode design creates a non-uniform (fringing) electric field-especially near the electrode walls. The design also causes variations in the radial electric field which provides an effective RF as ions move through the device and a radially confining effective potential that improves ion transmission through the device.
In this dissertation the analytical utility of the PDC IG drift cell for ion mobility separations will be explored. The radial focusing properties of the device will be presented along with studies of electrode geometry and its effect on ion mobility resolution and ion transmission through the drift cell. PDC IG drift cell length is also examined to determine its effect on mobility resolution and ion transmission. Finally, the PDC IG drift cell device is coupled to an orthogonal-acceleration time-of-flight mass spectrometer as well as a modular, PDC IG drift cell being adapted to a commercial qTOF mass spectrometer for IM-MS experiments.
|
Page generated in 0.0734 seconds