11

State Estimation and Voltage Security Monitoring Using Synchronized Phasor Measurements

Nuqui, Reynaldo Francisco 13 July 2001 (has links)
The phasor measurement unit (PMU) is considered to be one of the most important measuring devices in the future of power systems. The distinction comes from its unique ability to provide synchronized phasor measurements of voltages and currents from widely dispersed locations in an electric power grid. The commercialization of the global positioning satellite (GPS) with accuracy of timing pulses in the order of 1 microsecond made possible the commercial production of phasor measurement units. Simulations and field experiences suggest that PMUs can revolutionize the way power systems are monitored and controlled. However, it is perceived that costs and communication links will affect the number of PMUs to be installed in any power system. Furthermore, defining the appropriate PMU system application is a utility problem that must be resolved. This thesis will address two key issues in any PMU initiative: placement and system applications. A novel method of PMU placement based on incomplete observability using graph theoretic approach is proposed. The objective is to reduce the required number of PMUs by intentionally creating widely dispersed pockets of unobserved buses in the network. Observable buses enveloped such pockets of unobserved regions thus enabling the interpolation of the unknown voltages. The concept of depth of unobservability is introduced. It is a general measure of the physical distance of unobserved buses from those known. The effects of depth of unobservability on the number of PMU placements and the errors in the estimation of unobserved buses will be shown. The extent and location of communication facilities affects the required number and optimal placement of PMUs. The pragmatic problem of restricting PMU placement only on buses with communication facilities is solved using the simulated annealing (SA) algorithm. SA energy functions are developed so as to minimize the deviation of communication-constrained placement from the ideal strategy as determined by the graph theoretic algorithm. A technique for true real time monitoring of voltage security using synchronized phasor measurements and decision trees is presented as a promising system application. The relationship of widening bus voltage angle separation with network stress is exploited and its connection to voltage security and margin to voltage collapse established. Decision trees utilizing angle difference attributes are utilized to classify the network voltage security status. It will be shown that with judicious PMU placement, the PMU angle measurement is equally a reliable indicator of voltage security class as generator var production. A method of enhancing the weighted least square state estimator (WLS-SE) with PMU measurements using a non-invasive approach is presented. Here, PMU data is not directly inputted to the WLS estimator measurement set. A separate linear state estimator model utilizing the state estimate from WLS, as well as PMU voltage and current measurement is shown to enhance the state estimate. Finally, the mathematical model for a streaming state estimation will be presented. The model is especially designed for systems that are not completely observable by PMUs. Basically, it is proposed to estimate the voltages of unobservable buses from the voltages of those observable using interpolation. The interpolation coefficients (or the linear state estimators, LSE) will be calculated from a base case operating point. Then, these coefficients will be periodically updated using their sensitivities to the unobserved bus injections. It is proposed to utilize the state from the traditional WLS estimator to calculate the injections needed to update the coefficients. The resulting hybrid estimator is capable of producing a streaming state of the power system. Test results show that with the hybrid estimator, a significant improvement in the estimation of unobserved bus voltages as well as power flows on unobserved lines is achieved. / Ph. D.
12

Electromechanical Wave Propagation in Large Electric Power Systems

Huang, Liling 03 November 2003 (has links)
In a large and dense power network, the transmission lines, the generators and the loads are considered to be continuous functions of space. The continuum technique provides a macro-scale analytical tool to gain an insight into the mechanisms by which the disturbances initiated by faults and other random events propagate in the continuum. This dissertation presents one-dimensional and two-dimensional discrete models to illustrate the propagation of electromechanical waves in a continuum system. The more realistic simulations of the non-uniform distribution of generators and boundary conditions are also studied. Numerical simulations, based on the swing equation, demonstrate electromechanical wave propagation with some interesting properties. The coefficients of reflection, reflection-free termination, and velocity of propagation are investigated from the numerical results. Discussions related to the effects of electromechanical wave propagation on protection systems are given. In addition, the simulation results are compared with field data collected by phasor measurement units, and show that the continuum technique provides a valuable tool in reproducing electromechanical transients on modern power systems. Discussions of new protection and control functions are included. A clear understanding of these and related phenomena will lead to innovative and effective countermeasures against unwanted trips by the protection systems, which can lead to system blackouts. / Ph. D.
13

Open-Source Testbed to Evaluate the Cybersecurity of Phasor Measurement Units

Zimmermann, Markus Kenneth 22 June 2022 (has links)
The Phasor Measurement Unit provides clear data for ease of grid visibility. A major component of the device is the Global Positioning System (GPS) for time synchronization across the board. However, this device has become more susceptible to cyber-attacks such as spoofing. This paper constructs an opensource testbed for the playback of PMU data and testing of cyberattacks on PMUs. Using a local GPS device to simulate what is done in the PMU, MATLAB for data conversion, and Linux operating system running on Ubuntu, the simulator can be constructed. The spoofing attack is done by adding a phase shift of the incoming data to simulate that the data is coming from a different time stamp and shifts between the original. Finally, it is all brought together by viewing the output in an open source Phasor Data Concentrator (PDC) to validate the process. / Master of Science / To monitor the bulk electrical grid, devices used to calculate at what level the grid is at and what point in time as well. These devices that are called Phasor Measurement Units and send this data to the control center for engineers to process and make decisions. Within each device is a Global Positioning System (GPS) to tell which device is sending data and at what time. The GPS device is what is susceptible to be entered by malicious individuals. To better prepare and prevent this, a testbed would be a good solution to test if the preventative measure works. However, the best of the best costs too much money, so the next best solution is an open source test bed that could be implemented anyway. The work in this paper constructs an opensource testbed and simulates a full GPS spoofing attack.
14

Hadoop performance modeling and job optimization for big data analytics

Khan, Mukhtaj January 2015 (has links)
Big data has received a momentum from both academia and industry. The MapReduce model has emerged into a major computing model in support of big data analytics. Hadoop, which is an open source implementation of the MapReduce model, has been widely taken up by the community. Cloud service providers such as Amazon EC2 cloud have now supported Hadoop user applications. However, a key challenge is that the cloud service providers do not a have resource provisioning mechanism to satisfy user jobs with deadline requirements. Currently, it is solely the user responsibility to estimate the require amount of resources for their job running in a public cloud. This thesis presents a Hadoop performance model that accurately estimates the execution duration of a job and further provisions the required amount of resources for a job to be completed within a deadline. The proposed model employs Locally Weighted Linear Regression (LWLR) model to estimate execution time of a job and Lagrange Multiplier technique for resource provisioning to satisfy user job with a given deadline. The performance of the propose model is extensively evaluated in both in-house Hadoop cluster and Amazon EC2 Cloud. Experimental results show that the proposed model is highly accurate in job execution estimation and jobs are completed within the required deadlines following on the resource provisioning scheme of the proposed model. In addition, the Hadoop framework has over 190 configuration parameters and some of them have significant effects on the performance of a Hadoop job. Manually setting the optimum values for these parameters is a challenging task and also a time consuming process. This thesis presents optimization works that enhances the performance of Hadoop by automatically tuning its parameter values. It employs Gene Expression Programming (GEP) technique to build an objective function that represents the performance of a job and the correlation among the configuration parameters. For the purpose of optimization, Particle Swarm Optimization (PSO) is employed to find automatically an optimal or a near optimal configuration settings. The performance of the proposed work is intensively evaluated on a Hadoop cluster and the experimental results show that the proposed work enhances the performance of Hadoop significantly compared with the default settings.
15

ADVANCED FAULT AREA IDENTIFICATION AND FAULT LOCATION FOR TRANSMISSION AND DISTRIBUTION SYSTEMS

Fan, Wen 01 January 2019 (has links)
Fault location reveals the exact information needed for utility crews to timely and promptly perform maintenance and system restoration. Therefore, accurate fault location is a key function in reducing outage time and enhancing power system reliability. Modern power systems are witnessing a trend of integrating more distributed generations (DG) into the grid. DG power outputs may be intermittent and can no longer be treated as constants in fault location method development. DG modeling is also difficult for fault location purpose. Moreover, most existing fault location methods are not applicable to simultaneous faults. To solve the challenges, this dissertation proposes three impedance-based fault location algorithms to pinpoint simultaneous faults for power transmission systems and distribution systems with high penetration of DGs. The proposed fault location algorithms utilize the voltage and/or current phasors that are captured by phasor measurement units. Bus impedance matrix technique is harnessed to establish the relationship between the measurements and unknown simultaneous fault locations. The distinct features of the proposed algorithms are that no fault types and fault resistances are needed to determine the fault locations. In particular, Type I and Type III algorithms do not need the information of source impedances and prefault measurements to locate the faults. Moreover, the effects of shunt capacitance are fully considered to improve fault location accuracy. The proposed algorithms for distribution systems are validated by evaluation studies using Matlab and Simulink SimPowerSystems on a 21 bus distribution system and the modified IEEE 34 node test system. Type II fault location algorithm for transmission systems is applicable to untransposed lines and is validated by simulation studies using EMTP on a 27 bus transmission system. Fault area identification method is proposed to reduce the number of line segments to be examined for fault location. In addition, an optimal fault location method that can identify possible bad measurement is proposed for enhanced fault location estimate. Evaluation studies show that the optimal fault location method is accurate and effective. The proposed algorithms can be integrated into the existing energy management system for enhanced fault management capability for power systems.
16

Design of Phasor Measurement Unit and Its Application to Phasing Recognition of Distribution Equipments

Wu, Mei-Ching 11 July 2012 (has links)
Taipower Company has already completed the installation of the Outage Management System (OMS) in all service districts. The attributes of all distribution equipments and customers have been included in the computerized mapping system. However, the phasing attributes of distribution transformers are not very accurate in the database because they are very difficult to be identified for the distribution systems. The phase information of transformers in the OMS database is often inconsistent with the actual service phase, which deteriorates the performance of distribution system analysis, planning, and operation of Taipower distribution systems. The objective of this thesis is to develop an innovative Phasor Measurement Unit (PMU) to support the phasing identification of distribution transformers in a very effective way. The proposed PMU is used to measure the low voltage signal at the secondary side of transformers to prevent the survey personnel from safety problem. With the measured phases information of distribution transformers stored in the embedded system, the attributes of transformer phases in OMS can be updated to improve the accuracy of database. For the underground distribution systems, it is very difficult to receive the 1PPS signal of GPS system for timing synchronous to support the proposed transformer phasing measurement because all transformers are located at the building basement. This thesis proposes a timing synchronous module by using the Temperature Compensated Crystal Oscillator, TCXO to maintain the timing accuracy with high precision. Before executing the phasing measurement, this module is calibrated using the GPS 1PPS signal with fuzzy control calibration algorithm. It is found that the proposed PMU module can maintain the timing synchronous with 6˚, during two hours time period which will support the transformer phasing measurement by providing the reference timing synchronous even without the GPS 1PPS signal.
17

Synchrophasor Measurement Using Substation Intelligent Electronic Devices: Algorithms and Test Methodology

Ren, Jinfeng 2011 December 1900 (has links)
This dissertation studies the performance of synchrophasor measurement obtained using substation Intelligent Electronic Devices (IEDs) and proposes new algorithms and test methodology to improve and verify their performance when used in power system applications. To improve the dynamic performance when exposed to sinusoidal waveform distortions, such as modulation, frequency drift, abrupt change in magnitude, etc, an adaptive approach for accurately estimating phasors while eliminating the effect of various transient disturbances on voltages and currents is proposed. The algorithm pre-analyzes the waveform spanning the window of observation to identify and localize the discontinuities which affect the accuracy of phasor computation. A quadratic polynomial signal model is used to improve the accuracy of phasor estimates during power oscillations. Extensive experimental results demonstrate the advantages. This algorithm can also be used as reference algorithm for testing the performance of the devices extracting synchronized phasor measurements. A novel approach for estimating the phasor parameters, namely frequency, magnitude and angle in real time based on a newly constructed recursive wavelet transform is developed. This algorithm is capable of estimating the phasor parameters in a quarter cycle of an input signal. It features fast response and achieves high accuracy over a wide range of frequency deviations. The signal sampling rate and data window size can be selected to meet desirable application requirements, such as fast response, high accuracy and low computational burden. In addition, an approach for eliminating a decaying DC component, which has significant impact on estimating phasors, is proposed using recursive wavelet transform. This dissertation develops test methodology and tools for evaluating the conformance to standard-define performance for synchrophasor measurements. An interleaving technique applied on output phasors can equivalently increase the reporting rate and can precisely depict the transient behavior of a synchrophasor unit under the step input. A reference phasor estimator is developed and implemented. Various types of Phasor Measurement Units (PMUs) and PMU-enabled IEDs (Intelligent Electronic Devices) and time synchronization options have been tested against the standards using the proposed algorithm. Test results demonstrate the effectiveness and advantages.
18

Implementation and lessons learned from the Texas Synchrophasor Network

Kai, Moses An 15 February 2013 (has links)
For decades, power engineers have used simulations to predict grid stability and voltage phase angles. Only recently have equipment been available to actually measure phase angle at points hundreds of miles away. A few of these systems are presently operating in the US by electric grids including the Electric Reliability Council of Texas (ERCOT) and California Independent System Operator (ISO). However, the systems are in their infancy and are far from being used to improve grid reliability. This thesis describes the only independent synchronized phasor network that exists in the US. Thanks to Schweitzer Engineering Laboratories (SEL), we are streaming in points from three locations plus the University of Texas at Austin (UT Austin) as of January 2009. This thesis will describe this network and grid analysis done this far. / text
19

Novel algorithms for rotor angle security assessment in power systems

Wadduwage, Darshana Prasad 10 December 2015 (has links)
This thesis proposes two novel algorithms to analyze whether the power system loses synchronism subsequent to credible contingencies. The two algorithms are based on the concept of Lyapunov exponents (LEs) and the Prony analysis respectively. The concept of LEs is a theoretically sound technique to study the system stability of nonlinear dynamic systems. The LEs measure the exponential rates of divergence or convergence of trajectories in the state space. Considering the higher computational burden associated with the convergence of the true LEs, a modified algorithm is proposed to study the transient stability of the post-fault power system. It is shown that the finite-time LEs calculated by the modified algorithm accurately predicts the said stability. If the power system is transient stable, the rotor angle trajectories of the post-fault system exponentially decay with time. The damping ratios of the dominant oscillatory modes present in these power swings provide the indication on the oscillatory stability. The improved Prony algorithm presented in the thesis can be used to identify the oscillatory stability of the power system subsequent to a contingency. It is shown that that these new algorithms can be used in two applications in power systems, online dynamic security assessment and online oscillations monitoring. The proposed algorithm for rotor angle security assessment first uses the LEs-based algorithm to identify the transient stability. The stable cases are then processed by the improved Prony algorithm. The proposed online oscillations monitoring algorithm uses an event-detection logic and a parallel filter bank before applying the improved Prony algorithm on the measured response to extract the dominant oscillatory modes and to determine their frequencies and damping ratios. The suitability of the two algorithms for the aforementioned applications is investigated using different case studies. It is shown that the computational burdens of the two algorithms are acceptable for the online applications. Furthermore, the oscillations monitoring algorithm, extracts only the dominant modes present in the input signal, extracts both low-frequency inter-area modes and sub-synchronous modes, and performs well under noisy conditions. These features make it more appropriate for wide-area monitoring of power system oscillations using synchronized measurements. / February 2016
20

Data Quality in Wide-Area Monitoring and Control Systems : PMU Data Latency, Completness, and Design of Wide-Area Damping Systems

Zhu, Kun January 2013 (has links)
The strain on modern electrical power system operation has led to an ever increasing utilization of new Information Communication Technology (ICT) systems to enhance the reliability and efficiency of grid operation. Among these proposals, Phasor Measurement Unit (PMU)-based Wide-Area Monitoring and Control (WAMC) systems have been recognized as one of the enablers of “Smart Grid”, particularly at the transmission level, due to their capability to improve the real-time situational awareness of the grid. These systems differ from the conventional Supervisory Control And Data Acquisition (SCADA) systems in that they provide globally synchronized measurements at high resolutions. On the other hand, the WAMC systems also impose several stringent requirements on the underlying ICT systems, including performance, security, and availability, etc. As a result, the functionality of the WAMC applications is heavily, but not exclusively, dependent on the capabilities of the underlying ICT systems. This tight coupling makes it difficult to fully exploit the benefits of the synchrophasor technology without the proper design and configuration of ICT systems to support the WAMC applications. The strain on modern electrical power system operation has led to an ever increasing utilization of new Information Communication Technology (ICT) systems to enhance the reliability and efficiency of grid operation. Among these proposals, Phasor Measurement Unit (PMU)-based Wide-Area Monitoring and Control (WAMC) systems have been recognized as one of the enablers of “Smart Grid”, particularly at the transmission level, due to their capability to improve the real-time situational awareness of the grid. These systems differ from the conventional Supervisory Control And Data Acquisition (SCADA) systems in that they provide globally synchronized measurements at high resolutions. On the other hand, the WAMC systems also impose several stringent requirements on the underlying ICT systems, including performance, security, and availability, etc. As a result, the functionality of the WAMC applications is heavily, but not exclusively, dependent on the capabilities of the underlying ICT systems. This tight coupling makes it difficult to fully exploit the benefits of the synchrophasor technology without the proper design and configuration of ICT systems to support the WAMC applications. In response to the above challenges, this thesis addresses the dependence of WAMC applications on the underlying ICT systems. Specifically, two of the WAMC system data quality attributes, latency and completeness, are examined together with their effects on a typical WAMC application, PMU-based wide-area damping systems. The outcomes of this research include quantified results in the form of PMU communication delays and data frame losses, and probability distributions that can model the PMU communication delays. Moreover, design requirements are determined for the wide-area damping systems, and three different delay-robust designs for this WAMC application are validated based on the above results. Finally, a virtual PMU is developed to perform power system and communication network co-simulations. The results reported by this thesis offer a prospect for better predictions of the performance of the supporting ICT systems in terms of PMU data latency and completeness. These results can be further used to design and optimize the WAMC applications and their underlying ICT systems in an integrated manner. This thesis also contributes a systematic approach to design the wide-area damping system considering the PMU data latency and completeness. Finally, the developed virtual PMU, as part of a co-simulation platform, provides a means to investigate the dependence of WAMC applications on the capabilities of the underlying ICT systems in a cost-efficient manner. / <p>QC 20131015</p>