• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparação de dois meios para a criopreservação de sêmen quanto aos efeitos da suplementação lipídica e a ação antioxidante na viabilidade espermática em homens com parâmetros seminais alterados: estudo clínico randomizado / Comparison of two media for cryopreservation of semen on the effects of lipid supplementation and antioxidant action on sperm viability in men with altered seminal parameters: a randomized clinical trial

Fernanda Sicchieri 01 October 2018 (has links)
OBJETIVO: Comparar dois meios de congelamento para sêmen: o comercialmente disponível Meio de Congelamento TEST Yolk Buffer-Irvine Scientific - USA (TYB) e o crioprotetor sintético suplementado com fosfatidilcolina (PC) e antioxidante L-acetil-carnitina (ANTIOXPC - delineado pela Invitra Tecnologia de Reprodução Assistida - Brasil) em relação a motilidade progressiva (PR) e índice de fragmentação do DNA (IFD) em amostras de sêmen obtidas de homens com parâmetros seminais alterados. DESENHO: Ensaio clínico de nãoinferioridade. MATERIAIS E MÉTODOS: Foram incluídas amostras de sêmen com parâmetros seminais alterados (astenozoospermia) de 58 voluntários no Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo. As amostras de sêmen foram submetidas à análise antes e após a criopreservação. A motilidade dos espermatozoides foi avaliada pelo espermograma e a fragmentação do DNA espermático foi analisada pela técnica transferase-mediated dUTP nick-end labelling (TUNEL). Antes da criopreservação, todas as amostras de sêmen foram divididas e randomizadas para receber os crioprotetores TYB ou ANTIOX-PC, congelados no período mínimo de 30 dias e descongelados. Uma análise exploratória dos dados foi realizada através de medidas de posição central e dispersão. O teste t pareado foi usado para comparar os grupos. Comparações entre os dois meios, ANTIOX-PC e TYB, e sêmen fresco foram realizadas através de contrastes ortogonais, utilizando o modelo de regressão linear de efeitos mistos. Este modelo foi implementado no programa SAS 9.3 considerando o PROC MIXED. RESULTADOS: A motilidade PR (P = 0,78) e o IFD (P = 0,06) não foram diferentes quando comparados os meios ANTIOX-PC (12,40 ± 11,49 e 13,33 ± 10,54) e o TYB (12,09 ± 11,11 e15,83 ± 11,04), respectivamente. Esses dados mostraram que o crioprotetor sintético delineado não foi inferior na proteção dos espermatozoides comparado com o meio TYB. Além disso, o ANTIOX-PC reteve taxas mais altas de motilidade total43,36 ± 26,77) do que o TYB (34,79 ± 22,86; P <0,0001) e reduziu significativamente as taxas de espermatozoides imóveis (56,64 ± 26,77; P <0,0001) em relação ao TYB (65.00 ± 23.00).CONCLUSÃO: O meio ANTIOX-PC não pode ser considerado menos efetivo que o TYB em relação à motilidade PR e ao IFD. Parâmetros cinéticos observados em espermatozoides pósdescongelamento do diluente ANTIOX-PC demonstraram o impacto positivo do tratamento com fosfolipídios/antioxidantes na criotolerância espermática humana na ausência de aditivos animais. / OBJECTIVE: To compare two sperm freezing media: commercially available Freezing Medium TEST Yolk Buffer-Irvine Scientific - USA (TYB) and a synthetic cryoprotectant supplemented with phosphatidylcholine (PC) and antioxidante L-acetyl-carnitine (ANTIOXPC - designed by Invitra Assisted Reproduction Technology - Brazil) in relation to progressive motility and sperm DNA fragmentation index (DFI) in sêmen samples obtained from men with altered seminal parameters. DESIGN: Non-inferiority clinical trial. MATERIALS AND METHODS: Were included semen samples with altered seminal parameters (asthenospermia) from 58 volunteers at the Clinical Hospital of Ribeirao Preto Medical School, University of São Paulo. Semen samples were subjected to analysis both before and after cryopreservation. The sperm motility was evaluated by the spermogram and the sperm DNA fragmentation was analyzed by the transferase-mediated dUTP nick-end labeling technique (TUNEL). Before cryopreservation, all semen samples were divided and randomized to receive the cryoprotectants TYB or ANTIOX-PC, frozen and thawed after 30 days. An exploratory data analysis was carried out through measures of central position and dispersion. The paired t-test was used to compare the groups. Comparisons between the two media ANTIOX-PC and TYB, and fresh semen were performed through orthogonal contrasts using the mixed effects linear regression model. This model was implemented in the SAS 9.3 program considering PROC MIXED. RESULTS: Progressive motility (P = 0.78) and DFI (P = 0.06) were not different when comparing ANTIOX-PC (12.40 ± 11.49; and 13,33 ± 10.54) and TYB (12.09 ± 11.11 and 15.83 ± 11.04), respectively. These data showed that the synthetic cryoprotectant designed was not inferior in sperm protection compared to the TYB medium. In addition, ANTIOX-PC retained higher rates of overall motility (43.36 ± 26.77)than TYB (34.79 ± 22.86; P<0,0001) and significantly reduced the immotile sperm rates (56.64 ± 26.77; P<0,0001) when compared with TYB (65.00 ± 23.00). CONCLUSION: ANTIOX-PC medium can not be considered less effective than TYB relative to progressive motility and IFD. Kinetic parameters observed in post-thaw sperm from ANTIOX-PC extender demonstrated the positive impact of the phospholipid/antioxidant treatment on human sperm cryotolerance in the absence of animal aditives.
2

Comparação de dois meios para a criopreservação de sêmen quanto aos efeitos da suplementação lipídica e a ação antioxidante na viabilidade espermática em homens com parâmetros seminais alterados: estudo clínico randomizado / Comparison of two media for cryopreservation of semen on the effects of lipid supplementation and antioxidant action on sperm viability in men with altered seminal parameters: a randomized clinical trial

Sicchieri, Fernanda 01 October 2018 (has links)
OBJETIVO: Comparar dois meios de congelamento para sêmen: o comercialmente disponível Meio de Congelamento TEST Yolk Buffer-Irvine Scientific - USA (TYB) e o crioprotetor sintético suplementado com fosfatidilcolina (PC) e antioxidante L-acetil-carnitina (ANTIOXPC - delineado pela Invitra Tecnologia de Reprodução Assistida - Brasil) em relação a motilidade progressiva (PR) e índice de fragmentação do DNA (IFD) em amostras de sêmen obtidas de homens com parâmetros seminais alterados. DESENHO: Ensaio clínico de nãoinferioridade. MATERIAIS E MÉTODOS: Foram incluídas amostras de sêmen com parâmetros seminais alterados (astenozoospermia) de 58 voluntários no Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo. As amostras de sêmen foram submetidas à análise antes e após a criopreservação. A motilidade dos espermatozoides foi avaliada pelo espermograma e a fragmentação do DNA espermático foi analisada pela técnica transferase-mediated dUTP nick-end labelling (TUNEL). Antes da criopreservação, todas as amostras de sêmen foram divididas e randomizadas para receber os crioprotetores TYB ou ANTIOX-PC, congelados no período mínimo de 30 dias e descongelados. Uma análise exploratória dos dados foi realizada através de medidas de posição central e dispersão. O teste t pareado foi usado para comparar os grupos. Comparações entre os dois meios, ANTIOX-PC e TYB, e sêmen fresco foram realizadas através de contrastes ortogonais, utilizando o modelo de regressão linear de efeitos mistos. Este modelo foi implementado no programa SAS 9.3 considerando o PROC MIXED. RESULTADOS: A motilidade PR (P = 0,78) e o IFD (P = 0,06) não foram diferentes quando comparados os meios ANTIOX-PC (12,40 ± 11,49 e 13,33 ± 10,54) e o TYB (12,09 ± 11,11 e15,83 ± 11,04), respectivamente. Esses dados mostraram que o crioprotetor sintético delineado não foi inferior na proteção dos espermatozoides comparado com o meio TYB. Além disso, o ANTIOX-PC reteve taxas mais altas de motilidade total43,36 ± 26,77) do que o TYB (34,79 ± 22,86; P <0,0001) e reduziu significativamente as taxas de espermatozoides imóveis (56,64 ± 26,77; P <0,0001) em relação ao TYB (65.00 ± 23.00).CONCLUSÃO: O meio ANTIOX-PC não pode ser considerado menos efetivo que o TYB em relação à motilidade PR e ao IFD. Parâmetros cinéticos observados em espermatozoides pósdescongelamento do diluente ANTIOX-PC demonstraram o impacto positivo do tratamento com fosfolipídios/antioxidantes na criotolerância espermática humana na ausência de aditivos animais. / OBJECTIVE: To compare two sperm freezing media: commercially available Freezing Medium TEST Yolk Buffer-Irvine Scientific - USA (TYB) and a synthetic cryoprotectant supplemented with phosphatidylcholine (PC) and antioxidante L-acetyl-carnitine (ANTIOXPC - designed by Invitra Assisted Reproduction Technology - Brazil) in relation to progressive motility and sperm DNA fragmentation index (DFI) in sêmen samples obtained from men with altered seminal parameters. DESIGN: Non-inferiority clinical trial. MATERIALS AND METHODS: Were included semen samples with altered seminal parameters (asthenospermia) from 58 volunteers at the Clinical Hospital of Ribeirao Preto Medical School, University of São Paulo. Semen samples were subjected to analysis both before and after cryopreservation. The sperm motility was evaluated by the spermogram and the sperm DNA fragmentation was analyzed by the transferase-mediated dUTP nick-end labeling technique (TUNEL). Before cryopreservation, all semen samples were divided and randomized to receive the cryoprotectants TYB or ANTIOX-PC, frozen and thawed after 30 days. An exploratory data analysis was carried out through measures of central position and dispersion. The paired t-test was used to compare the groups. Comparisons between the two media ANTIOX-PC and TYB, and fresh semen were performed through orthogonal contrasts using the mixed effects linear regression model. This model was implemented in the SAS 9.3 program considering PROC MIXED. RESULTS: Progressive motility (P = 0.78) and DFI (P = 0.06) were not different when comparing ANTIOX-PC (12.40 ± 11.49; and 13,33 ± 10.54) and TYB (12.09 ± 11.11 and 15.83 ± 11.04), respectively. These data showed that the synthetic cryoprotectant designed was not inferior in sperm protection compared to the TYB medium. In addition, ANTIOX-PC retained higher rates of overall motility (43.36 ± 26.77)than TYB (34.79 ± 22.86; P<0,0001) and significantly reduced the immotile sperm rates (56.64 ± 26.77; P<0,0001) when compared with TYB (65.00 ± 23.00). CONCLUSION: ANTIOX-PC medium can not be considered less effective than TYB relative to progressive motility and IFD. Kinetic parameters observed in post-thaw sperm from ANTIOX-PC extender demonstrated the positive impact of the phospholipid/antioxidant treatment on human sperm cryotolerance in the absence of animal aditives.

Page generated in 0.0661 seconds