• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • No language data
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The dosimetry of a highly-collimated bremsstrahlung source in air

Shannon, Michael Paul 06 July 2009 (has links)
The characterization and measurement of the spatial, temporal and energy emission of air-scattered photons, electrons and neutrons generated near 10 MV or greater accelerator-based bremsstrahlung photon sources is becoming important in many applications. The national and homeland security research community is interested in developing technologies which can detect illicit materials at substantial standoff distances in outdoor environments. These systems are referred to as "active" interrogation systems and are defined as inspection systems that take advantage of an externally applied "source" to perform traditional imaging of, or to stimulate characteristic emissions from, an inspected object. A key concern in the development of these systems is the ability to effectively predict the dose equivalents at long standoff distances from these sources in order to ascertain the operational radiation safety of said systems. Current computational radiation transport simulation tools have the ability to effectively model these systems; however, a paucity of experimental data exists in comparing the results of these simulations. A methodology to assess the radiation dose surrounding a high-energy bremsstrahlung-based accelerator system for national defense applications was developed. Fluence-to-dose conversion coefficients for the International Commission on Radiation Units and Measurements operational quantity ambient dose equivalent were calculated for photons and electrons up to 25 MeV utilizing the Los Alamos National Laboratory Monte Carlo N-Particle code, MCNP5 Version 1.51. Special consideration was given to the treatment of secondary charged particle equilibrium in all simulations. An extensive set of system simulations was performed to model a prototype high-energy bremsstrahlung-based accelerator system to obtain photon, electron and neutron fluence spectra. These fluence data were folded with the calculated ambient dose equivalent conversion coefficients as well as previously published effective dose conversion coefficients. A set of integral air-scatter measurements for accelerator-generated primary and secondary radiations (photon and neutron) were performed around the prototype system in order to provide a comparative data set from which to determine the total dose equivalent both in the beam (on-axis) and outside of the beam (off-axis).

Page generated in 0.1125 seconds