• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 136
  • 8
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 150
  • 150
  • 111
  • 51
  • 43
  • 34
  • 31
  • 29
  • 26
  • 23
  • 23
  • 23
  • 22
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tratamento físico-químico de vinhaça por coagulação, floculação e sedimentação e seu aproveitamento no cultivo da microalga Chlorella vulgaris visando a produção de biocombustível / Physico-chemical treatment of vinasse by coagulation, flocculation and sedimentation and its utilization in the cultivation of microalgae Chlorella vulgaris

Lóio, Davi Ambrozio 18 June 2013 (has links)
Dentre os resíduos da agroindústria brasileira, a vinhaça, efluente da produção de etanol, se destaca por ser produzida em grande volume e ser altamente poluente. Por apresentar elevada concentração de nutrientes, sua principal aplicação tem sido a fertirrigação da lavoura canavieira, prática que pode causar impactos adversos ao solo e recursos hídricos. Uma alternativa promissora é sua utilização como meio de cultura na produção de biomassa de microalgas, as quais produzem lipídios conversíveis a biodiesel, sendo necessária a redução da concentração de partículas causadoras de cor e turbidez, proporcionando melhoria das condições de entrada de luz nos fotobiorreatores. Nesse sentido, o presente trabalho propôs a utilização das técnicas de coagulação, floculação e sedimentação para a clarificação da vinhaça, visando sua adequação ao cultivo de microalgas. Na etapa I foram investigados os coagulantes cloreto férrico, sulfato de alumínio, hidróxido de cálcio, tanino e cinco polímeros sintéticos, em diferentes concentrações e faixas de pH, visando-se as maiores remoções de cor e turbidez. Nas dosagens empregadas, os coagulantes cloreto férrico e sulfato de alumínio não apresentaram desempenho satisfatório. Os melhores resultados foram obtidos com o uso do polímero catiônicoLAB TAE 409, o qual proporcionou reduções de 22% da cor e 78% da turbidez (com relação à vinhaça pré-centrifugada), mesmo em baixas dosagens (20 mg/L). Na etapa II foram realizados ensaios em jarteste, onde foram determinados a melhor temperatura (30ºC), a dosagem de polímero LAB TAE 409 (20 mg/L), o pH (~4,70, sem ajuste) e os parâmetros de mistura e sedimentação (TML = 5 min, GML = 60 s-1 e VSED = 1 cm/min), os quais proporcionam as maiores reduções de cor (76%) e turbidez (96%), com relação à vinhaça bruta. A partir do melhor tratamento definido na etapa II, a vinhaça foi empregada como meio para o cultivo da microalga Chlorella vulgaris (etapa III), conforme seguintes proporções: V1 (90% vinhaça tratada / 10% inóculo), V2 (45% vinhaça tratada / 45% água deionizada / 10% inóculo), V3 (5% vinhaça tratada / 85% água deionizada / 10% inóculo), comparados ao cultivo em meio padrão WC. Embora menores que os crescimentos (biomassa) obtidos no cultivo em meio padrão WC, os meios constituídos de vinhaça pré-tratada proporcionaram crescimento de Chlorella vulgaris, com velocidades específicas de crescimento próximas ao meio WC, indicando seu potencial uso na obtenção de biomassa dessa espécie de microalga. / Among the brazilian agro-industrial residues, vinasse, effluent from ethanol production, stands out for being produced in large volume and can be highly pollutant. Presenting high concentration of nutrients, its main application has been the irrigation of sugarcane, a practice that may cause adverse impacts to soil and water resources. A promising alternative is to use the vinasse as the culture medium for microalgal biomass production, which produce lipids convertible to biodiesel. Therefore, it is required an adaptation to this type of cultivation, mainly, through the reduction of the concentration of particles that cause turbidity and color, providing improved lighting conditions in photobioreactors. In this way, this work proposed the use of the coagulation, flocculation and sedimentation techniques for clarifying vinasse, aiming the cultivation of microalgae. In step I were investigated the coagulants ferric chloride, aluminum sulfate, calcium hydroxide, tannin and five synthetic polymers, at different concentrations and pH ranges, aiming at the highest color and turbidity removal. In the dosages investigated, ferric chloride and aluminum sulfate did not show satisfactory performance. The best results were obtained with use of the cationic polymer LAB TAE 409, which provided a 22% reduction of color and 78% of turbidity (relative to vinasse pre-centrifuged), even at low dosages (20 mg/L). In step II, tests were carried out in jartest, which were determined the best temperature (30 ºC), the polymer LAB TAE 409 dosage (20 mg/L), pH (~ 4.70, without adjustment), and the mixing and sedimentation parameters (TML = 5 min, GML = 60 s-1 VSED = 1 cm/min), which provided the major reductions in color (76%) and turbidity (96%), relative to the raw vinasse. From the best treatment defined in step II, vinasse was used as medium for the cultivation of microalgae Chlorella vulgaris (stage III), according to the following proportions: V1 (90% treated vinasse / 10% inoculum), V2 (45% vinasse treated / deionized water 45% / 10% inoculum), V3 (5% vinasse treated / deionized water 85% / 10% inoculum), compared to standard WC medium. Although lower than the growths (biomass) obtained in culture using WC, the mediums with pretreated vinasse have provided the growth of Chlorella vulgaris, with specific growth rates near the WC medium, indicating its potential use for obtaining this microalgal biomass.
2

Técnicas aplicadas ao tratamento e redução dos efluentes líquidos de uma empresa de saneantes domissanitários

Peres, Silvana Drago January 2005 (has links)
A empresa estudada está sediada em Porto Alegre, RS, Brasil, e fabrica produtos de limpeza. Os efluentes provêm das águas de lavagens dos tanques e misturadores de produção, recipientes utilizados na separação de matérias-primas e da lavagem do próprio piso da fábrica, onde ocorrem derramamentos de produtos. Foi implantada uma estação de tratamento de efluentes que opera por processos físico-químicos de coagulação/floculação e adsorção. Entretanto, observou-se que era ineficiente para atender aos parâmetros de qualidade de água exigidos pela legislação. Assim, o objeto deste estudo foi minimizar a geração de efluentes e aperfeiçoar a operação da estação de tratamento dos efluentes líquidos da empresa. A metodologia de trabalho consistiu na caracterização do efluente industrial; monitoramento do desempenho da estação de tratamento de efluentes, implantação de mudanças no processo produtivo para verificar a possibilidade de minimização da geração de efluentes bem como da carga poluidora, e estudo de alternativas de tratamento para melhorar a qualidade da água. Os parâmetros avaliados foram pH, DQO, DBO, fósforo total, nitrogênio total, óleos e graxas, surfactantes, sólidos sedimentáveis e sólidos suspensos. Os resultados demonstram que o efluente apresenta pH alcalino, uma elevada carga orgânica, é rico em nitrogênio e fósforo e possui uma alta concentração de surfactantes. Entretanto, a implantação de um sistema de produção mais limpo, através da programação prévia do processo produtivo, e aplicação de novos procedimentos durante as operações de envase, permitiu que o volume de efluentes gerados diminuísse de 8 m3/dia para 6 m3/dia. A carga de poluente na ETE baixou significativamente, resultando em maior eficiência da estação de tratamento de efluentes. Assim, foi possível atingir, exata ou aproximadamente, todos os parâmetros de emissão padrão. O estudo das alternativas de tratamento também comprovou que o tratamento físicoquímico de coagulação/floculação é mais eficiente quando seguido de um tratamento de adsorção por carvão ativado. A fotocatálise heterogênea, com aplicação de luz UV como forma de polimento ao efluente, reduz substancialmente a quantidade de matéria orgânica e surfactantes presentes no efluente. Os valores da relação DBO/DQO, para o efluente tratado, que variam de 0,29 a 0,34, demonstram a possibilidade de degradação biológica, desde que haja aclimatação ou indução dos microrganismos. Esse fato abre a possibilidade de realizar o tratamento biológico do efluente industrial, misturado ou não ao esgoto cloacal gerado na empresa. / The company studied produces cleaning reagents and is located in Porto Alegre, RS, Brazil. The effluent comes from many washing operations, including equipment and ground cleaning. A physical-chemical treatment plant was installed. It is based on coagulation/flocculation and activated carbon adsorption. However, the treatment operation did not reach the water quality emission standards established by the legislation. Thus, the aim of this work was to minimize the effluent generation and to improve the effluent treatment plant efficiency. The methodology consisted of characterization of the industrial effluent, evaluation of effluent treatment plant, implantation of clean technology procedures and the study of new alternatives for water quality improvement. The parameters analyzed were pH, DQO, DBO, total phosphorous, total nitrogen, oils and greases, surfactants, settable solids, and suspended solids. The results showed that the effluent presents an alkaline pH, a high organic load, is rich in nitrogen and phosphorous, and presents a high concentration of surfactants. However, the implantation of clean technology procedures, by process programming and employees training, allowed a volume reduction from 8 m3/day to 6 m3/day. The load of pollutants was significantly reduced, allowing a better performance of the effluent treatment plant. The emission treatment reached, or became very near the standard. The study of new alternatives also proved that the physical-chemical treatment of coagulation/flocculation is more efficient when followed by an activated carbon adsorption treatment. The use of the TiO2 – photocatalysis process – reduced surfactants concentration in effluent. The BOD/COD relationship, ranged from 0,29 to 0,34, showed that biological degradation is possible, provided that there is microorganism acclimatizing. This fact allows the possibility for the biological treatment of the industrial effluent to be either dumped into the general sewage generated in the company or not.
3

Técnicas aplicadas ao tratamento e redução dos efluentes líquidos de uma empresa de saneantes domissanitários

Peres, Silvana Drago January 2005 (has links)
A empresa estudada está sediada em Porto Alegre, RS, Brasil, e fabrica produtos de limpeza. Os efluentes provêm das águas de lavagens dos tanques e misturadores de produção, recipientes utilizados na separação de matérias-primas e da lavagem do próprio piso da fábrica, onde ocorrem derramamentos de produtos. Foi implantada uma estação de tratamento de efluentes que opera por processos físico-químicos de coagulação/floculação e adsorção. Entretanto, observou-se que era ineficiente para atender aos parâmetros de qualidade de água exigidos pela legislação. Assim, o objeto deste estudo foi minimizar a geração de efluentes e aperfeiçoar a operação da estação de tratamento dos efluentes líquidos da empresa. A metodologia de trabalho consistiu na caracterização do efluente industrial; monitoramento do desempenho da estação de tratamento de efluentes, implantação de mudanças no processo produtivo para verificar a possibilidade de minimização da geração de efluentes bem como da carga poluidora, e estudo de alternativas de tratamento para melhorar a qualidade da água. Os parâmetros avaliados foram pH, DQO, DBO, fósforo total, nitrogênio total, óleos e graxas, surfactantes, sólidos sedimentáveis e sólidos suspensos. Os resultados demonstram que o efluente apresenta pH alcalino, uma elevada carga orgânica, é rico em nitrogênio e fósforo e possui uma alta concentração de surfactantes. Entretanto, a implantação de um sistema de produção mais limpo, através da programação prévia do processo produtivo, e aplicação de novos procedimentos durante as operações de envase, permitiu que o volume de efluentes gerados diminuísse de 8 m3/dia para 6 m3/dia. A carga de poluente na ETE baixou significativamente, resultando em maior eficiência da estação de tratamento de efluentes. Assim, foi possível atingir, exata ou aproximadamente, todos os parâmetros de emissão padrão. O estudo das alternativas de tratamento também comprovou que o tratamento físicoquímico de coagulação/floculação é mais eficiente quando seguido de um tratamento de adsorção por carvão ativado. A fotocatálise heterogênea, com aplicação de luz UV como forma de polimento ao efluente, reduz substancialmente a quantidade de matéria orgânica e surfactantes presentes no efluente. Os valores da relação DBO/DQO, para o efluente tratado, que variam de 0,29 a 0,34, demonstram a possibilidade de degradação biológica, desde que haja aclimatação ou indução dos microrganismos. Esse fato abre a possibilidade de realizar o tratamento biológico do efluente industrial, misturado ou não ao esgoto cloacal gerado na empresa. / The company studied produces cleaning reagents and is located in Porto Alegre, RS, Brazil. The effluent comes from many washing operations, including equipment and ground cleaning. A physical-chemical treatment plant was installed. It is based on coagulation/flocculation and activated carbon adsorption. However, the treatment operation did not reach the water quality emission standards established by the legislation. Thus, the aim of this work was to minimize the effluent generation and to improve the effluent treatment plant efficiency. The methodology consisted of characterization of the industrial effluent, evaluation of effluent treatment plant, implantation of clean technology procedures and the study of new alternatives for water quality improvement. The parameters analyzed were pH, DQO, DBO, total phosphorous, total nitrogen, oils and greases, surfactants, settable solids, and suspended solids. The results showed that the effluent presents an alkaline pH, a high organic load, is rich in nitrogen and phosphorous, and presents a high concentration of surfactants. However, the implantation of clean technology procedures, by process programming and employees training, allowed a volume reduction from 8 m3/day to 6 m3/day. The load of pollutants was significantly reduced, allowing a better performance of the effluent treatment plant. The emission treatment reached, or became very near the standard. The study of new alternatives also proved that the physical-chemical treatment of coagulation/flocculation is more efficient when followed by an activated carbon adsorption treatment. The use of the TiO2 – photocatalysis process – reduced surfactants concentration in effluent. The BOD/COD relationship, ranged from 0,29 to 0,34, showed that biological degradation is possible, provided that there is microorganism acclimatizing. This fact allows the possibility for the biological treatment of the industrial effluent to be either dumped into the general sewage generated in the company or not.
4

Técnicas aplicadas ao tratamento e redução dos efluentes líquidos de uma empresa de saneantes domissanitários

Peres, Silvana Drago January 2005 (has links)
A empresa estudada está sediada em Porto Alegre, RS, Brasil, e fabrica produtos de limpeza. Os efluentes provêm das águas de lavagens dos tanques e misturadores de produção, recipientes utilizados na separação de matérias-primas e da lavagem do próprio piso da fábrica, onde ocorrem derramamentos de produtos. Foi implantada uma estação de tratamento de efluentes que opera por processos físico-químicos de coagulação/floculação e adsorção. Entretanto, observou-se que era ineficiente para atender aos parâmetros de qualidade de água exigidos pela legislação. Assim, o objeto deste estudo foi minimizar a geração de efluentes e aperfeiçoar a operação da estação de tratamento dos efluentes líquidos da empresa. A metodologia de trabalho consistiu na caracterização do efluente industrial; monitoramento do desempenho da estação de tratamento de efluentes, implantação de mudanças no processo produtivo para verificar a possibilidade de minimização da geração de efluentes bem como da carga poluidora, e estudo de alternativas de tratamento para melhorar a qualidade da água. Os parâmetros avaliados foram pH, DQO, DBO, fósforo total, nitrogênio total, óleos e graxas, surfactantes, sólidos sedimentáveis e sólidos suspensos. Os resultados demonstram que o efluente apresenta pH alcalino, uma elevada carga orgânica, é rico em nitrogênio e fósforo e possui uma alta concentração de surfactantes. Entretanto, a implantação de um sistema de produção mais limpo, através da programação prévia do processo produtivo, e aplicação de novos procedimentos durante as operações de envase, permitiu que o volume de efluentes gerados diminuísse de 8 m3/dia para 6 m3/dia. A carga de poluente na ETE baixou significativamente, resultando em maior eficiência da estação de tratamento de efluentes. Assim, foi possível atingir, exata ou aproximadamente, todos os parâmetros de emissão padrão. O estudo das alternativas de tratamento também comprovou que o tratamento físicoquímico de coagulação/floculação é mais eficiente quando seguido de um tratamento de adsorção por carvão ativado. A fotocatálise heterogênea, com aplicação de luz UV como forma de polimento ao efluente, reduz substancialmente a quantidade de matéria orgânica e surfactantes presentes no efluente. Os valores da relação DBO/DQO, para o efluente tratado, que variam de 0,29 a 0,34, demonstram a possibilidade de degradação biológica, desde que haja aclimatação ou indução dos microrganismos. Esse fato abre a possibilidade de realizar o tratamento biológico do efluente industrial, misturado ou não ao esgoto cloacal gerado na empresa. / The company studied produces cleaning reagents and is located in Porto Alegre, RS, Brazil. The effluent comes from many washing operations, including equipment and ground cleaning. A physical-chemical treatment plant was installed. It is based on coagulation/flocculation and activated carbon adsorption. However, the treatment operation did not reach the water quality emission standards established by the legislation. Thus, the aim of this work was to minimize the effluent generation and to improve the effluent treatment plant efficiency. The methodology consisted of characterization of the industrial effluent, evaluation of effluent treatment plant, implantation of clean technology procedures and the study of new alternatives for water quality improvement. The parameters analyzed were pH, DQO, DBO, total phosphorous, total nitrogen, oils and greases, surfactants, settable solids, and suspended solids. The results showed that the effluent presents an alkaline pH, a high organic load, is rich in nitrogen and phosphorous, and presents a high concentration of surfactants. However, the implantation of clean technology procedures, by process programming and employees training, allowed a volume reduction from 8 m3/day to 6 m3/day. The load of pollutants was significantly reduced, allowing a better performance of the effluent treatment plant. The emission treatment reached, or became very near the standard. The study of new alternatives also proved that the physical-chemical treatment of coagulation/flocculation is more efficient when followed by an activated carbon adsorption treatment. The use of the TiO2 – photocatalysis process – reduced surfactants concentration in effluent. The BOD/COD relationship, ranged from 0,29 to 0,34, showed that biological degradation is possible, provided that there is microorganism acclimatizing. This fact allows the possibility for the biological treatment of the industrial effluent to be either dumped into the general sewage generated in the company or not.
5

Tratamento físico-químico de vinhaça por coagulação, floculação e sedimentação e seu aproveitamento no cultivo da microalga Chlorella vulgaris visando a produção de biocombustível / Physico-chemical treatment of vinasse by coagulation, flocculation and sedimentation and its utilization in the cultivation of microalgae Chlorella vulgaris

Davi Ambrozio Lóio 18 June 2013 (has links)
Dentre os resíduos da agroindústria brasileira, a vinhaça, efluente da produção de etanol, se destaca por ser produzida em grande volume e ser altamente poluente. Por apresentar elevada concentração de nutrientes, sua principal aplicação tem sido a fertirrigação da lavoura canavieira, prática que pode causar impactos adversos ao solo e recursos hídricos. Uma alternativa promissora é sua utilização como meio de cultura na produção de biomassa de microalgas, as quais produzem lipídios conversíveis a biodiesel, sendo necessária a redução da concentração de partículas causadoras de cor e turbidez, proporcionando melhoria das condições de entrada de luz nos fotobiorreatores. Nesse sentido, o presente trabalho propôs a utilização das técnicas de coagulação, floculação e sedimentação para a clarificação da vinhaça, visando sua adequação ao cultivo de microalgas. Na etapa I foram investigados os coagulantes cloreto férrico, sulfato de alumínio, hidróxido de cálcio, tanino e cinco polímeros sintéticos, em diferentes concentrações e faixas de pH, visando-se as maiores remoções de cor e turbidez. Nas dosagens empregadas, os coagulantes cloreto férrico e sulfato de alumínio não apresentaram desempenho satisfatório. Os melhores resultados foram obtidos com o uso do polímero catiônicoLAB TAE 409, o qual proporcionou reduções de 22% da cor e 78% da turbidez (com relação à vinhaça pré-centrifugada), mesmo em baixas dosagens (20 mg/L). Na etapa II foram realizados ensaios em jarteste, onde foram determinados a melhor temperatura (30ºC), a dosagem de polímero LAB TAE 409 (20 mg/L), o pH (~4,70, sem ajuste) e os parâmetros de mistura e sedimentação (TML = 5 min, GML = 60 s-1 e VSED = 1 cm/min), os quais proporcionam as maiores reduções de cor (76%) e turbidez (96%), com relação à vinhaça bruta. A partir do melhor tratamento definido na etapa II, a vinhaça foi empregada como meio para o cultivo da microalga Chlorella vulgaris (etapa III), conforme seguintes proporções: V1 (90% vinhaça tratada / 10% inóculo), V2 (45% vinhaça tratada / 45% água deionizada / 10% inóculo), V3 (5% vinhaça tratada / 85% água deionizada / 10% inóculo), comparados ao cultivo em meio padrão WC. Embora menores que os crescimentos (biomassa) obtidos no cultivo em meio padrão WC, os meios constituídos de vinhaça pré-tratada proporcionaram crescimento de Chlorella vulgaris, com velocidades específicas de crescimento próximas ao meio WC, indicando seu potencial uso na obtenção de biomassa dessa espécie de microalga. / Among the brazilian agro-industrial residues, vinasse, effluent from ethanol production, stands out for being produced in large volume and can be highly pollutant. Presenting high concentration of nutrients, its main application has been the irrigation of sugarcane, a practice that may cause adverse impacts to soil and water resources. A promising alternative is to use the vinasse as the culture medium for microalgal biomass production, which produce lipids convertible to biodiesel. Therefore, it is required an adaptation to this type of cultivation, mainly, through the reduction of the concentration of particles that cause turbidity and color, providing improved lighting conditions in photobioreactors. In this way, this work proposed the use of the coagulation, flocculation and sedimentation techniques for clarifying vinasse, aiming the cultivation of microalgae. In step I were investigated the coagulants ferric chloride, aluminum sulfate, calcium hydroxide, tannin and five synthetic polymers, at different concentrations and pH ranges, aiming at the highest color and turbidity removal. In the dosages investigated, ferric chloride and aluminum sulfate did not show satisfactory performance. The best results were obtained with use of the cationic polymer LAB TAE 409, which provided a 22% reduction of color and 78% of turbidity (relative to vinasse pre-centrifuged), even at low dosages (20 mg/L). In step II, tests were carried out in jartest, which were determined the best temperature (30 ºC), the polymer LAB TAE 409 dosage (20 mg/L), pH (~ 4.70, without adjustment), and the mixing and sedimentation parameters (TML = 5 min, GML = 60 s-1 VSED = 1 cm/min), which provided the major reductions in color (76%) and turbidity (96%), relative to the raw vinasse. From the best treatment defined in step II, vinasse was used as medium for the cultivation of microalgae Chlorella vulgaris (stage III), according to the following proportions: V1 (90% treated vinasse / 10% inoculum), V2 (45% vinasse treated / deionized water 45% / 10% inoculum), V3 (5% vinasse treated / deionized water 85% / 10% inoculum), compared to standard WC medium. Although lower than the growths (biomass) obtained in culture using WC, the mediums with pretreated vinasse have provided the growth of Chlorella vulgaris, with specific growth rates near the WC medium, indicating its potential use for obtaining this microalgal biomass.
6

Platinum on graphite (0001): A model system for the study of physical and chemical properties of small metal islands

Eppell, Steven Joseph January 1991 (has links)
No description available.
7

Desenvolvimento e ensaios de um sistema de mensuração de condutividade elétrica do solo. / Development and field evaluation of a soil electrical conductivity measuring system.

Pincelli, André Luis Sacomano 03 December 2004 (has links)
A correlação entre as medidas de condutividade elétrica e propriedades físico-químicas do solo é uma das linhas de estudo que vem sendo exploradas onde os conceitos de agricultura de precisão estão mais avançados. Este estudo teve como objetivo avaliar a eficiência do monitoramento da condutividade elétrica do solo a partir do desenvolvimento de dois sistemas. O primeiro, denominado de Resistência Elétrica do Solo (RES), consiste em definir a condutividade elétrica de um material através de uma amostra de dimensões conhecidas, para medir a sua resistência elétrica utilizando dois eletrodos. O segundo, denominado de Duas Pontas (DP), consiste em definir a condutividade elétrica de um material aplicando uma corrente elétrica em uma amostra para medir a alteração no potencial elétrico, gerado pelo meio em que a corrente elétrica transitou, utilizando dois eletrodos dispostos linearmente. Para a avaliação dos resultados obtidos pelos sistemas desenvolvidos foi utilizado como referência um sistema comercial de origem norte americana e algumas propriedades do solo. Os equipamentos de condutividade elétrica do solo foram aplicados em duas áreas pertencentes à Escola Superior de Agricultura "Luiz de Queiroz" e em época distintas. Na Área 1, com 4,97 ha, o levantamento dos dados foi feito na primeira quinzena de Agosto de 2003 e na Área 2, com 1,3 ha, o levantamento dos dados foi feito na segunda quinzena de Dezembro de 2003. Após a aquisição dos dados experimentais foram feitas análises estatísticas descritivas e exploratórias, análises geoestatísticas, construção de mapas de superfície, análises de correlação e regressão linear múltipla a fim de avaliar os sistemas. De acordo com a metodologia desenvolvida e análises de funcionamento dos equipamentos, foi possível verificar que os sistemas construídos para a coleta, transformação e armazenagem dos dados foram eficientes no levantamento dos pontos amostrais. No entanto os sistemas de condutividade elétrica do solo não apresentaram a eficiência desejada no monitoramento das propriedades do solo em ambas as áreas experimentais. Quando os sistemas desenvolvidos foram comparados ao sistema comercial, também foi possível observar que não houve correlação no monitoramento, o que sugere a necessidade da continuidade e aprofundamento no desenvolvimento desses sistemas. / The correlation between electrical conductivity and physical-chemical properties of the soil is one of the research areas that have been explored where precision agriculture concepts are more advanced. This study had the objective of evaluating the soil electrical conductivity mapping efficiency of different measuring systems. The first one, known as Electrical Resistance of the Soil consists in defining the electrical conductivity of any given material using a sample of known dimensions, to measure its electrical resistance using two electrodes. The second one, the Two Edges method, consists in defining the electrical conductivity of a material applying an electric current in a sample to measure any change on the electric potential, generated by the environment in which the electric current transited through, using two linearly displaced electrodes. To evaluate the results obtained by the developed systems some soil properties and a commercial soil electrical conductivity measuring system where used as guidelines. The soil electrical conductivity equipments mapped two fields, at the Escola Superior de Agricultura "Luiz de Queiroz". In Field 1 (4,97 ha) the data collecting process took place in the first fortnight of august 2003, and, in Field 2 (1,3 ha), the sampling process took place in the second fortnight of December 2003. After the acquisition of the experimental data, descriptive and exploratory statistical and geostatistical analysis were made, electrical conductivity surface maps were obtained and correlation and multiple linear regression analysis, in order to evaluate both systems, were made. In accordance to the developed methodology and analysis of the equipment, it was possible to check that the systems developed to acquire, transform and store the data were efficient in mapping the sampling points. However, the soil electrical conductivity systems did not show the desired efficiency in mapping the soil properties in both experimental fields. When the developed systems were compared to a commercial one it was also possible to observe that there was no correlation in the measurements, which suggests the necessity of new developments on these systems.
8

Caracterização físico-química de SiC sintetizado pelo processo Acheson a partir de diferentes fontes de SiO2 / Physical-chemical characterization of SiC synthesized by Acheson process from different sources of SiO2

Silva, Mariane Capellari Leite da 27 February 2015 (has links)
Atualmente, há uma forte demanda por cerâmicas como materiais estruturais para substituição de metais e ligas de elevada dureza e para uso em ambientes hostis. Dentre as famílias das cerâmicas estruturais, o SiC se destaca devido ao seu conjunto de propriedades: alta resistência à oxidação/corrosão, elevada resistência à abrasão, elevada condutividade térmica, baixa massa específica, elevada dureza, boa resistência ao choque térmico e manutenção da maioria destas propriedades em temperaturas elevadas. O processo Acheson se caracteriza, industrialmente, como o principal processo de síntese do SiC, consistindo em dois eletrodos sólidos, conectados a pó de grafite compactado, circundados por uma mistura de sílica e coque, em que o aquecimento é realizado eletricamente entre temperaturas de 2200 a 2600 oC [SOMIYA, 1991]. A formação do SiC é dependente da pressão parcial dos gases, da temperatura, do tamanho de grão dos reagentes, das propriedades individuais de cada grão, assim como da área de contato e do grau de mistura entre SiO2 e C [LINDSTAD, 2002]. O SiC produzido pelo processo Acheson contém impurezas como Al, Fe, Ti, Na, provindas da matéria-prima, que durante a síntese têm seu comportamento influenciado pela variação de temperatura. Partículas metálicas ou carbetos dessas impurezas estão distribuídos na matriz de SiC, sendo encontrados à medida que a temperatura diminui, com exceção do Al que se encontra em solução sólida com o SiC, substituindo os átomos de Si na rede cristalina [WEIMER, 1997]. Os objetivos deste trabalho se concentraram na caracterização e avaliação da influência da matéria-prima e das condições de processo no SiC obtido pelo processo Acheson. Podendo-se observar, através das análises químicas, mineralógicas e microestruturais, que a distribuição das impurezas, ao longo da secção transversal do SiC, é independente da matéria-prima precursora, sendo que estas se concentram nas regiões mais distantes do núcleo de grafite, porém seus teores são superiores para o SiC sintetizado a partir de uma matéria-prima menos pura, as quais ainda apresentaram temperatura de início do processo de oxidação do SiC pelo menos 50 oC menor, quando comparado ao SiC sinterizados a partir de matérias-primas com maior grau de pureza. / Currently, there is a strong demand for ceramics as structural materials to replace metals and alloys with high hardness for use in hostile environments. Among structural ceramics families, silicon carbide stands out due to its unique properties combination: high corrosion/oxidation resistance, high abrasion resistance, low density, high hardness, high thermal conductivity, good thermal shock resistance and maintenance of the majority of these properties at elevated temperatures. The Acheson process is industrially the main synthesis process of silicon carbide, consisting of two solid electrodes connected to compacted graphite powder, surrounded by a mixture of silica and petroleum coke, wherein the heating is performed electrically between 2200 to 2600 oC [SOMIYA, 1991]. The formation of SiC depends on the partial pressure of gases, temperature, reactants grain size, the properties of each individual grain as well as the contact area and the degree of mixing between SiO2 and C [LIDSTAD, 2002]. The SiC produced by the Acheson process contains impurities from the raw materials, such as Al, Fe, Ti and Na, which during the synthesis are influenced by the temperature gradient. Metal or carbides particles of these impurities are distributed in SiC matrix, being found as the temperature decreases, with exception of Al that forms solid solution with SiC by replacing the Si atoms in the crystal lattice [WEIMER, 1997]. The objectives of this work was the characterization and evaluation of the influence of raw materials and process conditions on the behavior of silicon carbide synthesized by Acheson process. It was observed, through chemical, mineralogical and microstructural analyzes, that the distribution of impurities along the cross section of synthesized SiC is independent of the raw material precursor, and these are concentrated in the most distant regions of the graphite core, but its contents are superior to SiC synthesized from a less pure raw material, which also showed a change in the beginning of the SiC oxidation process, at least 50 ° C lower, than the synthesized SiC from raw material with higher purity.
9

Tratamento físico químico da vinhaça de destilaria de etanol com biopolímero à base de cálcio / Physical chemical treatment of distillery vinasse of ethanol with calcium-based biopolymer

Sapla, Rudner Brancalhoni 06 June 2012 (has links)
Este presente trabalho teve como objetivo a investigação do desempenho de um biopolímero experimental à base de cálcio, desenvolvido e fornecido por uma empresa americana, na coagulação, floculação e sedimentação da vinhaça bruta como tratamento físico-químico na remoção de carga orgânica e na concentração de compostos fertilizantes no lodo. O estudo do tratamento da vinhaça por meio da aplicação deste biopolímero possibilitaria, hipoteticamente, uma redução significativa da carga orgânica como tratamento inicial da vinhaça, além de concentrar os nutrientes presentes na vinhaça no lodo gerado para uso fertilizante. Foram realizados ensaios com coagulantes convencionais (sulfato ferroso, cloreto férrico e óxido de cálcio) para efeito de comparação entre estes e o biopolímero. Os ensaios de coagulação, floculação e sedimentação foram realizados em escala de laboratório com uso do equipamento Jar Test. Os ensaios foram divididos em três etapas. Na primeira etapa foram realizados ensaios aplicando-se determinadas dosagens de biopolímero e variando-se os tempos de coagulação, velocidades de rotação, além de realizar ou não a mistura lenta após a etapa de coagulação, a fim de verificar se estes parâmetros poderiam otimizar o processo de tratamento com o aplicação do biopolímero. Para segunda etapa do procedimento experimental foram realizados ensaios com os outros coagulantes: óxido de cálcio, sulfato férrico e cloreto férrico. Os ensaios com o cloreto férrico e o sulfato férrico foram realizados nas seguintes condições: velocidade de mistura rápida de 200 rpm por um período de tempo de 30 segundos e velocidade de mistura lenta de 80 rpm por um período de 20 minutos. Já os ensaios com óxido de cálcio foram realizados com apenas velocidade de mistura rápida de 200 rpm variando os períodos de tempo em 1, 5 e 10 minutos. O tempo de sedimentação para separação dos flocos formados foi de 2 horas para todas as etapas. O tratamento com biopolímero experimental apresentou resultados de remoção de matéria orgânica abaixo dos valores esperados, que era na faixa de 60% a 80%. Os resultados limitaram-se a valores de 10% a 35% de remoção de DQO. Porém, a remoção de turbidez atingiu valores elevados, próximos a 90%. Para os compostos relacionados à fertilização NPK (nitrogênio, fósforo e potássio), o tratamento com biopolímero experimental obteve as melhores eficiências de remoção de fósforo (48,3%) e de NTK (17,2%) em relação aos demais coagulantes, porém não apresentou remoção de potássio. Não houve diferença significativa na eficiência de remoção de DQO quando se alteram as condições operacionais de velocidade de agitação. Já o aumento no tempo de agitação diminui a eficiência de remoção de DQO. / This work aimed to investigate the performance of an experimental biopolymer calcium-based, developed and supplied by an American company, on gross vinasse coagulation, flocculation and sedimentation as a physical chemical treatment on organic load removal and on fertilizer compounds concentration in sludge. The study of the vinasse treatment through the application of this biopolymer would allow, hypothetically a significant reduction of the organic load as vinasse initial treatment, besides concentrating the vinasse found nutrients in the sludge created for fertilizer use. Assays were performed with conventional coagulants (ferrous sulfate, ferric chloride and calcium oxide) for comparison between them and the biopolymer. Tests of coagulation, flocculation and sedimentation were carried out in laboratory scale using Jar Test equipment. The experiments were divided in three stages. In the first stage assays were performed applying certain dosages of biopolymer and varying the clotting time, rotational speeds in addition to performing or not performing the slow mixture after the clotting stage in order to check if these parameters could optimize the treatment process with the biopolymer application. For the second stage of the experimental procedure tests were developed with other coagulants: calcium oxide, ferric sulphate and ferric chloride. Tests with ferric chloride and ferric sulphate were performed under the following conditions: fast mixing speed of 200 rpm for a period of 30 seconds and slow mixing speed of 80 rpm for a period of 20 minutes. Considering the assays with calcium oxide, they were carried out using only rapid mixing speed of 200 rpm by varying the time periods at 1, 5 and 10 minutes. The sedimentation time to the formed flakes separation was two hours for all stages. Treatment with experimental biopolymer presented results of removal of organic matter below the expected values, which was in the range 60% to80%. The results limited to values of 10% to 35% of COD clearance. However, the removal of turbidity reached high values near 90%. For compounds related to NPK (nitrogen, phosphorus and potassium) fertilization, the treatment with experimental biopolymer obtained the best efficiency of phosphorus removal (48,3) and TKN removal (17.2%) in comparison with the other coagulants, but showed no removal of potassium. There was no significant difference in COD removal efficiency when the operating conditions of agitation speed are changed. Regarding to the increase in the agitation time, it reduces the efficiency of COD removal.
10

Desenvolvimento e ensaios de um sistema de mensuração de condutividade elétrica do solo. / Development and field evaluation of a soil electrical conductivity measuring system.

André Luis Sacomano Pincelli 03 December 2004 (has links)
A correlação entre as medidas de condutividade elétrica e propriedades físico-químicas do solo é uma das linhas de estudo que vem sendo exploradas onde os conceitos de agricultura de precisão estão mais avançados. Este estudo teve como objetivo avaliar a eficiência do monitoramento da condutividade elétrica do solo a partir do desenvolvimento de dois sistemas. O primeiro, denominado de Resistência Elétrica do Solo (RES), consiste em definir a condutividade elétrica de um material através de uma amostra de dimensões conhecidas, para medir a sua resistência elétrica utilizando dois eletrodos. O segundo, denominado de Duas Pontas (DP), consiste em definir a condutividade elétrica de um material aplicando uma corrente elétrica em uma amostra para medir a alteração no potencial elétrico, gerado pelo meio em que a corrente elétrica transitou, utilizando dois eletrodos dispostos linearmente. Para a avaliação dos resultados obtidos pelos sistemas desenvolvidos foi utilizado como referência um sistema comercial de origem norte americana e algumas propriedades do solo. Os equipamentos de condutividade elétrica do solo foram aplicados em duas áreas pertencentes à Escola Superior de Agricultura “Luiz de Queiroz” e em época distintas. Na Área 1, com 4,97 ha, o levantamento dos dados foi feito na primeira quinzena de Agosto de 2003 e na Área 2, com 1,3 ha, o levantamento dos dados foi feito na segunda quinzena de Dezembro de 2003. Após a aquisição dos dados experimentais foram feitas análises estatísticas descritivas e exploratórias, análises geoestatísticas, construção de mapas de superfície, análises de correlação e regressão linear múltipla a fim de avaliar os sistemas. De acordo com a metodologia desenvolvida e análises de funcionamento dos equipamentos, foi possível verificar que os sistemas construídos para a coleta, transformação e armazenagem dos dados foram eficientes no levantamento dos pontos amostrais. No entanto os sistemas de condutividade elétrica do solo não apresentaram a eficiência desejada no monitoramento das propriedades do solo em ambas as áreas experimentais. Quando os sistemas desenvolvidos foram comparados ao sistema comercial, também foi possível observar que não houve correlação no monitoramento, o que sugere a necessidade da continuidade e aprofundamento no desenvolvimento desses sistemas. / The correlation between electrical conductivity and physical-chemical properties of the soil is one of the research areas that have been explored where precision agriculture concepts are more advanced. This study had the objective of evaluating the soil electrical conductivity mapping efficiency of different measuring systems. The first one, known as Electrical Resistance of the Soil consists in defining the electrical conductivity of any given material using a sample of known dimensions, to measure its electrical resistance using two electrodes. The second one, the Two Edges method, consists in defining the electrical conductivity of a material applying an electric current in a sample to measure any change on the electric potential, generated by the environment in which the electric current transited through, using two linearly displaced electrodes. To evaluate the results obtained by the developed systems some soil properties and a commercial soil electrical conductivity measuring system where used as guidelines. The soil electrical conductivity equipments mapped two fields, at the Escola Superior de Agricultura “Luiz de Queiroz”. In Field 1 (4,97 ha) the data collecting process took place in the first fortnight of august 2003, and, in Field 2 (1,3 ha), the sampling process took place in the second fortnight of December 2003. After the acquisition of the experimental data, descriptive and exploratory statistical and geostatistical analysis were made, electrical conductivity surface maps were obtained and correlation and multiple linear regression analysis, in order to evaluate both systems, were made. In accordance to the developed methodology and analysis of the equipment, it was possible to check that the systems developed to acquire, transform and store the data were efficient in mapping the sampling points. However, the soil electrical conductivity systems did not show the desired efficiency in mapping the soil properties in both experimental fields. When the developed systems were compared to a commercial one it was also possible to observe that there was no correlation in the measurements, which suggests the necessity of new developments on these systems.

Page generated in 0.0772 seconds