• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 35
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 102
  • 102
  • 33
  • 31
  • 17
  • 15
  • 12
  • 12
  • 12
  • 12
  • 12
  • 10
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Einstellung von PI-Reglern bei Send-on-Delta-Abtastung: Regelkreisoptimierung unter Berücksichtigung von Energieeffizienz, Netzlast und Regelgüte

Hensel, Burkhard 25 October 2017 (has links)
Energieeffizienz hat in Forschung und Alltag eine zentrale Bedeutung. Arbeiten verschiedene elektronische Geräte zusammen, um gemeinsam eine Regelungsaufgabe zu lösen, müssen sie miteinander kommunizieren. Ein Beispiel aus dem Alltag sind Funk-Raumtemperaturregler, bei denen ein batteriebetriebener Temperatursensor und ein Heizungsaktor (Stellantrieb am Heizungsventil) über drahtlose Kommunikation zusammenarbeiten. Diese Kommunikation benötigt oft mehr Energie als der Betrieb der eigentlichen (elektronischen) Funktionalität der Teilsysteme. Energieeffizienter als die in Regelkreisen übliche periodische (äquidistante) Abtastung ist – durch eine Verringerung der Nachrichtenrate – eine ereignisbasierte Abtastung. Send-on-Delta-Abtastung ist die am weitesten verbreitete Art der ereignisbasierten Abtastung. Dabei wird der Wert der Regelgröße (im Beispiel die Raumtemperatur) nicht in konstanten Zeitintervallen übertragen, sondern nur dann, wenn er sich um einen bestimmten Betrag geändert hat. Der mit einem Anteil von über 90 % im Praxiseinsatz am weitesten verbreitete Reglertyp ist der PID-Regler, wobei die meisten als „PID-Regler“ bezeichneten Regler aus verschiedenen Gründen keinen D-Anteil (Differential-Anteil) verwenden und daher als „PI-Regler“ bezeichnet werden können. Die vorliegende Arbeit verfolgt das Ziel, systematisch zu untersuchen, wie man PI-Regler einstellen sollte, um neben dem Erreichen einer hohen Regelgüte auch die Vorteile der Send-on-Delta-Abtastung bezüglich der Netzlastreduktion und Energieeffizienz bestmöglich auszunutzen. Die „Gewichtung“ dieser sich teilweise widersprechenden Kriterien ist anwendungsspezifisch einstellbar. / Energy efficiency is very important both in science and everyday life. If different electronic devices work together, for example for solving a control task together, they have to communicate with each other. An everyday life example are room temperature controllers using radio communication between a battery-powered temperature sensor and a heating actuator. This communication often needs more energy than the operation of the actual (electronic) functionality of the components. More energy-efficient than the commonly used periodic sampling is event-based sampling, due to the reduction of the message rate. Send-on-delta sampling is the most widely-known kind of event-based sampling. In that case, the value of the controlled variable (e.g. the room temperature) is not transmitted equidistantly but only when it has changed by a specific amount. The most successful controller in practice is the PID controller. The most so-called “PID controllers” do not use the D part (differential action) for several reasons and can therefore be called “PI controllers”. This work analyses systematically how the parameters of a PI controller should be tuned to reach besides a high control quality also a good exploitation of the advantages of send-on-delta sampling regarding network load reduction and energy efficiency. The “weighting” of these partially contradicting criteria is application specifically adjustable.
102

Development of Test Methodology for Electromechanical Linear Actuators

Linder, Isak January 2022 (has links)
This master thesis aims to develop a test methodology for electromechanical linear actuators. A linear actuator acts as a linear motor, converting a power source to linear motion. The electromechanical linear actuator in this project has an electric motor as its power source and uses a rack and pinion system to transfer that power to linear motion.  The test methodology is to impose a force onto the rack of the actuator, to ensure that operation under a load scenario is within specification. To accomplish this, the design of a test rig implementation is analyzed. The test rig consists of the test unit, which is to be tested, the load unit, which is to provide the load force, and a control system for the load unit. The load unit is another linear actuator and is controlled via a load cell. The load cell gives out the load force being applied, and the controller gives out the corresponding appropriate motor command to the load unit to ensure the load force is as desired. This analysis is done through simulation of the setup. Viable options for the setup were first analyzed in order to implement the deemed promising options for a setup into a simulation environment. The simulation environment in this project was Simscape, an extension of MATLAB’s Simulink. In simulation the parameters for the test rig were rigorously analyzed, in order to determine acceptable thresholds. The primary load unit tested was another electromechanical linear actuator from Cascade Drives, the model A-100-8P. Two secondary setups, one using the same model as being tested, and another setup using two of the models being tested. Simulation found that the suggested options’ applied load force have a poor rise time, large overshoot and substantial oscillation errors. The primary source for this was determined to be the latency between load cell input, and motor command output in the controller. The poor metrics from the result could lead to problems when emergency braking, and with a long honing period, which would render most test data unusable.

Page generated in 0.0352 seconds