• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 122
  • 10
  • 2
  • 2
  • 2
  • Tagged with
  • 140
  • 80
  • 58
  • 56
  • 56
  • 49
  • 37
  • 33
  • 32
  • 32
  • 31
  • 26
  • 26
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação de pilares de concreto armado colorido de alta resistência, submetidos a elevadas temperaturas. / Evaluation of reinforced HSCC columns at high temperature.

Carlos Amado Britez 23 March 2011 (has links)
Apesar da quantidade de variáveis envolvidas, ainda persiste uma dúvida na comunidade acadêmica sobre o comportamento do concreto de alta resistência em situação de incêndio, considerando-o como mais ou menos suscetível à ocorrência do fenômeno de desplacamento (spalling) tipo explosivo. Em parte, essa dúvida decorre do fato de que, muitas vezes, os programas experimentais são conduzidos em amostras envolvendo corpos-de-prova padronizados, cilíndricos ou cúbicos, que não levam em consideração a influência de parâmetros relacionados com as dimensões dos elementos estruturais nem com a taxa e configuração das armaduras. Outros aspectos relevantes, como o tipo de agregado utilizado na mistura de concreto, bem como a idade e umidade interna do elemento ensaiado, dificilmente são abordados nas pesquisas e, muitas vezes, simplesmente são omitidos, o que dificulta a visão ampla e real do comportamento térmico do concreto de alta resistência. Esta pesquisa apresenta um programa experimental pioneiro realizado no Brasil em um pilar de concreto de alta resistência, armado, colorido, com idade de oito anos, fc,8anos de 140MPa, agregado graúdo basáltico, agregado miúdo quartzoso, seção transversal de 70cm x 70cm, 200cm de altura, ensaiado sem carregamento e com exposição de três faces pelo período de 180 minutos (3h), sob as temperaturas da curva-padrão de incêndio ISO 834. O pilar protótipo ensaiado é réplica dos pilares reais do edifício e-Tower, construído em 2002, na cidade de São Paulo, Brasil. Os resultados obtidos demonstraram que, neste caso, o concreto colorido de alta resistência comportou-se de forma íntegra frente ao fogo e que a utilização de pigmento à base de óxido de ferro, pode atuar também como um excelente termômetro natural, auxiliando na avaliação da condição da estrutura pósincêndio. / In spite of the several factors that influence the behavior of concrete columns under fire conditions, there is a belief among the research community, that the high-strength concrete is more susceptible to explosive spalling than normal-strength concrete. This doubt, in part, is attributed to the small unreinforced concrete samples (specimens) used in experimental programs, to evaluate the fire resistance of structural concrete. On the other hand, relevant aspects as the coarse aggregate type used in the concrete mixture, as well as the age and content moisture (relative humidity) are not considered in the researches and sometimes simply omitted. This research presents a pioneer experimental program, carried out in Brazil on a high strength colored reinforced concrete column (HSCC) with 200cm high, eight yearsold, fc,8years of 140MPa, basalt coarse aggregate, cross section of 700mm x 700mm, tested under no load and with three faces exposed to a standard fire curve ISO 834 for a period of 180min (3h). The column prototype is a replica of the actual columns of the e-Tower Building, constructed in 2002 in São Paulo city, Brazil. The results demonstrated concrete column integrity under experimental fire and that the iron oxide pigments can work as an excellent natural thermometer, contributing in the evaluation of the structure post-fire.
112

Estudo experimental de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos e solda / Experimental study of a precast concrete beam-column connection using welded steel shapes

André Marcon Trotta 03 September 2012 (has links)
Nesta pesquisa estudou-se o comportamento de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos embutidos nos elementos estruturais. O modelo da ligação estudada permite a transmissão de momentos fletores positivo e negativo. Para a continuidade de momento fletor negativo, utilizam-se um consolo metálico com seção \"U\" embutido no pilar e dentes metálicos com seção tubular retangular embutidos nas vigas, soldados. Para a continuidade de momento positivo, utilizam-se cantoneiras metálicas embutidas no pilar que são soldadas à armadura positiva da viga. O estudo consistiu em análise experimental de um modelo cruciforme em duas etapas. Na primeira etapa o modelo foi solicitado a carregamentos cíclicos reversíveis por meio de um atuador servo hidráulico acoplado sobre o topo do pilar. Na segunda etapa, o modelo foi solicitado a carregamento estático monotônico por meio de macacos hidráulicos dispostos sob o pilar para causar a ruptura com momento negativo. O modelo apresentou uma considerável facilidade de montagem, já que na fase transitória a ligação é articulada e o consolo do pilar em perfil \"U\" permite a estabilidade lateral da viga. O consolo metálico embutido no pilar escoou muito antes de atingir a capacidade resistente dos outros componentes da ligação, pois na seção da ligação junto à face do pilar, apenas o consolo resiste à flexão. / In this research the behavior of a beam-column connection in precast concrete system using welded steel shapes built-in structural elements was studied. The model of the studied connection allows transmission of positive and negative moments. For the continuity of negative moment, is used a steel \"U\" shaped corbel inserted in the column welded with tubular section steel hangers inserted in each beam. For the continuity of positive moment, use is made of metal embedded in abutment ledges that are welded to the positive reinforcement of the beam. The study consisted on experimental analysis of a cross-shaped specimen in two steps. In the first step was applied to the specimen a cyclic load using hydraulic actuator coupled to the column head. In the second step was applied in the specimen a static load using hydraulic jack positioned under the column to cause rupture with negative moment. The connection model showed a considerably easy assembly, as in the transitional phase the connection is articulated and the steel \"U\" shaped corbel of the column allows the lateral stability of the beam. The rupture occurred by yielding of the steel U shaped corbel in the section near the column. The steel corbel inserted in the column yielded before reaches the resistant capacity of other components of the connection, because of the section in the connection close of the column, only steel corbel resists the negative moment.
113

Estudo teórico-experimental do efeito da laje na transferência de forças em ligações viga-pilar misto preenchido / Experimental and theorical analysis of slab effect on the force transfer strength of steel beam to concrete filled columns connection

Rômulo da Silva Farias 07 May 2008 (has links)
Este trabalho tem como objetivo analisar a influência da laje de concreto armado em uma ligação viga-pilar misto mediante um estudo experimental e uma modelagem numérica. A ligação considerada é constituída por uma viga de aço unida a um pilar misto preenchido através de barras rosqueadas que trabalham como parafusos passantes. Esse tipo de ligação já foi investigado em trabalhos anteriores, mediante análise experimental em modelos que não incluíam a laje, resultando em uma indesejável ruptura dos parafusos. A análise da ligação completa, com a presença da laje de concreto tornando a ligação uma ligação mista, além de ser mais realista, melhora as características de resistência e rigidez do modelo, além de tornar mais dúctil o seu comportamento. Para isso foram analisados três modelos experimentais que se diferenciam pela ausência ou tipo de conector de cisalhamento presente na região interna do pilar misto. Os resultados obtidos mostraram que a ruptura da ligação passou a ser determinada pela laje, associada ao escoamento da armadura longitudinal sem que a ligação viga-pilar fosse comprometida. Para a análise numérica foi utilizado o pacote computacional DIANA®, baseado no método dos elementos finitos. Os modelos numéricos foram desenvolvidos e calibrados pelos resultados experimentais, produzindo resultados bastante satisfatórios. Finalmente foi realizada uma análise numérica paramétrica variando a armadura longitudinal da laje e a resistência do concreto com o objetivo de se entender melhor a influência desses parâmetros no comportamento da ligação investigada. / The main objective of this work was to analyze the contribution of the concrete slab for the behavior of a steel beam-concrete filled composite column connection through an experimental program and also a numerical modeling. The considered connection was constituted of steel beams connected to a concrete filled tubular column of rectangular cross section by means of passing bars. This type of connection was studied before through an experimental analysis of connections that did not include the slab, resulting in failure of the passing bars. In the present study, the presence of the slab is considered, turning the connection a composite one. The studied model is more representative of the real structure, and also improves the resistance and the stiffness of the connection, turning the behavior more ductile. Three specimens were tested, where the studied variable was the type of shear connector, angles or stud-bolts, and one specimen without connectors as a reference. The obtained results showed that the failure was determined by the slab, associated to the yielding of the longitudinal reinforcement, without affecting the beam column connection. The finite element based software DIANA® was used to the numerical analysis. The numerical models were developed and calibrated by the experimental results, producing a good agreement. Finally, a parametric analysis was done, varying the slab longitudinal reinforcement and the concrete strength in order to better understand the influence of these parameters in the behavior of the studied connection.
114

Comportamento de chumbadores grauteados de ligações viga-pilar parcialmente resistentes a momento fletor / Behavior of grouted dowel of partial moment resistant beam-to-column connections

Eduardo Aurélio Barros Aguiar 05 May 2010 (has links)
Neste trabalho estudou-se o comportamento dos chumbadores grauteados, usados em ligações viga-pilar parcialmente resistentes a momento fletor. O foco da pesquisa foi a análise teórica e experimental do mecanismo resistente do chumbador inclinado. O programa experimental englobou 15 modelos, sendo que as variáveis analisados foram: a) diâmetros dos chumbadores, de 16 mm, 20 mm e 25 mm; b) inclinações dos chumbadores, de 0º (chumbador normal à interface), 45º e 60º; c) resistência à compressão do concreto adjacente ao chumbador, sendo usado concreto das classes C35 e C50; d) aplicação de força de compressão normal à interface. Os resultados experimentais indicaram aumentos significativos tanto na capacidade última quanto na rigidez a cisalhamento do chumbador. Foram realizadas simulações numéricas, onde foi verificada a sensibilidade dos resultados aos parâmetros inerentes à interface concreto - almofada de apoio, sendo desenvolvidas expressões para estimar tais parâmetros. Com base na análise experimental e em análises numéricas, foram propostos modelos analíticos que conseguiram representar de forma satisfatória a influência da inclinação e demais parâmetros analisados no mecanismo resistente do chumbador. / This research deals with the behavior of grouted dowels, used in partial moment resistant beam-to-column connections. The focus of the research was the theoretical and experimental analysis of dowels resistant mechanism. The experimental program include 15 models, and its variables analyzed were: a) the dowel diameter of 16 mm, 20 mm and 25 mm; b) the dowel inclination of 0° (dowels perpendicular to the interface), 45° and 60°; c) compressive strength of concrete adjacent to the dowels of classes C35 and C50, d) application of compression load, normal to the interface. Experimental results indicated significant increases in ultimate capacity and the shear stiffness of the dowels. Numerical simulations were carried out which identified the sensitivity of results to the parameters of the interface concrete bearing pad, and developed expressions to estimate such parameters are given. Based on experimental and numerical analysis analytical models have been proposed that could adequately represent the influence of inclination and other parameters in the mechanism resistant dowels.
115

Ligações de montagem viga-pilar para estruturas de concreto pré-moldado: estudo de caso / Assembly connections beam-column for structures of precast concrete: case study

Lisiane Pereira Prado 19 September 2014 (has links)
A pesquisa em questão é direcionada ao estudo de uma ligação provisória entre o pilar e a viga pré-moldada para que possa servir de suporte durante a execução da ligação de estrutura, que consiste na utilização de barras de aço salientes do pilar e da viga, traspassando entre si, finalizada por concreto com adição de fibras. O uso de consolo metálico formado por perfil tipo \"U\" e dente metálico constituído de um perfil de seção retangular vazado foi o método proposto para a ligação provisória, na qual a montagem da viga no pilar se dá pelo encaixe dos elementos. O modelo adotado como dente metálico é denominado \"Cazaly Hanger\". Para avaliar o comportamento da ligação estudada foram analisados os modelos analíticos referentes aos elementos da ligação e, posteriormente, foi montado um pórtico estrutural com a ligação provisória em estudo, para analisar o seu comportamento sob um carregamento estático e monotônico. Inicialmente foi aplicada uma força referente a 71,75% da capacidade da ligação, no meio do vão da viga e excêntrico ao seu eixo para analisar a torção na ligação, simulando uma possível força acidental que venha a ocorrer durante a montagem dos elementos. Na segunda etapa foi aplicada uma força a 1/2,94 do vão da viga a fim de determinar a capacidade do dente metálico e, na terceira e última etapa, o carregamento foi aplicado a 1/7,14 do vão da viga, na extremidade oposta a força aplicada na etapa 2, para determinar a capacidade de suporte do consolo metálico. Os resultados dos ensaios mostraram que a capacidade resistida pelo dente metálico foi 33% maior que o determinado no modelo analítico e, o estado limite último do consolo metálico constituído por perfil \"U\" foi caracterizado pela deformação excessiva da alma, na região superior do consolo. Pode-se concluir que o modelo de cálculo usado no trabalho foi coerente com os resultados encontrados para o dente metálico, mas, para os consolos metálicos, os valores teóricos não foram compatíveis com os resultados encontrados no modelo prático. / The research is directed to the study of a beam-column temporary connections to provide support during the execution of structure connection, which consist on using steel bars protruding from the column and beam finalized by addition of concrete with fibers. The use of steel \"U\" shaped corbel in the column and a steel hangers rectangular hollow core section in the beam was proposed for temporary connection method, in which the erecting the beam in the columns occurs by the nest of the elements. To evaluate the behavior of the studied connections it was analyzed the analytical models of connections and, after were building a structural portico with the connection to analyze their behavior under static and monotonic loading. Initially it was applied a load corresponding to 71,75% of the connection capacity, mid-span of the beam and its eccentric to check the torsion moment on the connection, simulating a possible live load that may occur during assembly of the elements. In the second stage was applied a load of 1/2,94 span beam to determine the capacity of steel hanger rectangular hollow core section and the third and last step the load was applied at 1/7,14 span of the beam, the end opposite the load applied in step 2, to determine the ability of the steel \"U\" shaped corbel. The results showed that the steel hanger inserted capacity was 33% higher than determined in the analytical model and the ultimate limit state of the steel \"U\" shaped corbel was characterized by excessive deformation of vertical plate, in the upper region of corbel. Can conclude that the calculation model used in the study was consistent with the results found for the steel hangers rectangular hollow core section, but for the steel \"U\" shaped corbel, the theoretical values were not consistent with the results found in practical model.
116

Ligação viga-pilar em elementos pré-moldados de concreto solidarizados por concreto reforçado com fibras de aço: análises estática e dinâmica / Beam-column connection in precast concrete structures using steel fiber reinforced concrete

Luiz Álvaro de Oliveira Júnior 13 June 2012 (has links)
No presente trabalho, utiliza-se concreto com fibras de aço, traspasse de armaduras e chaves de cisalhamento para desenvolver uma ligação viga-pilar capaz de resistir a ações cíclicas e dinâmicas e que possa ser empregada na pré-moldagem de estruturas de casas de força de usinas hidrelétricas. Para atingir este objetivo, inicialmente foram realizados ensaios de caracterização dos materiais, cujos resultados mostraram aumentos de 34% na resistência à tração na flexão, 16% na resistência à compressão e 33% na tenacidade, comprovando os efeitos benéficos das fibras de aço nas propriedades mecânicas do concreto. Em seguida, foram realizados ensaios de tração em tirantes, cujos resultados sugeriram que um comprimento de 15Ø é suficiente para que a emenda desenvolva as tensões de aderência de modo adequado; e ensaios de cisalhamento, cujos resultados mostraram que a ligação viga-pilar resiste a tensões de cisalhamento direto de até 0,77 MPa. Na sequencia, foram realizados ensaios cíclicos em dois modelos cruciformes para caracterização da ligação (um monolítico e outro de concreto pré-moldado, o qual empregava concreto com 1% de fibras na região da ligação), sendo o carregamento aplicado em cinco níveis de força, cada um com dez ciclos de carregamento e descarregamento. Os resultados desses ensaios mostraram que a ligação do modelo em concreto pré-moldado apresentou 85% da resistência do modelo monolítico e ruptura governada por flexão. Por fim, os ensaios dinâmicos foram realizados nos modelos cruciformes em três diferentes situações (íntegros, fraturados e após ruptura da ligação) para estimar o coeficiente de amortecimento, o qual sofreu uma redução de 31% após o ensaio cíclico. Simulações computacionais foram realizadas para complementar a investigação realizada neste trabalho. Elas mostraram representação aceitável da rigidez, mas não da resistência do modelo. / In the present work, steel fiber reinforced concrete, splicing bars and shear keys are used in order to develop a beam-column connection able to support cyclic and dynamic loadings and which can be used in precasting power houses structures of power plants. To achieve this goal, tests were carried out to characterize the materials, which showed increases of 34% in flexural tensile strength, 16% in compressive strength and 33% in toughness factor, confirming the beneficial effects of steel fibers in mechanical properties of the concrete. Then, tensile tests were carried out on rods, whose results suggested that a length of 15Ø can assure appropriate development of bond stresses through the splice; and shear tests, whose results showed that the beam-column connection resists to shear stresses of up to 0,77 MPa on shear key. After, cyclic tests were performed in two cruciform models in order to characterize the beam-column connection (one monolithic and the other precast concrete, which employed 1% steel fiber reinforced concrete in connection region, being the loading applied in five loading levels, each one in 10 cycles of loading and unloading. Results of these tests showed that precast beam-column connection presented 85% of the strength presented by the monolithic model and bending failure. Finally, dynamic tests were performed in cruciform models in three different situations (uncracked, cracked and after failure) for estimating the damping ratio, which was reduced by 31% after cycles. Computer simulations were performed to complement the research developed in this work. They showed acceptable representation of stiffness, but the strength of the model.
117

Reforço e incremento da rigidez à flexão de ligações viga-pilar de estruturas de concreto pré-moldado com polímero reforçado com fibra de carbono (PRFC) / Flexural strengthening and stiffness increasing of precast beam-to-column connections by NSM CFRP strips

Tatiana de Cássia Coutinho Silva da Fonseca 18 December 2007 (has links)
Este trabalho apresenta o desenvolvimento de uma técnica de incremento da resistência e da rigidez à flexão de ligações de elementos de concreto pré-moldado, com aplicação de laminados de polímero reforçado com fibra de carbono (PRFC). O procedimento adotado consiste na colagem dos laminados de PRFC em entalhes no concreto de cobrimento, de acordo com a técnica conhecida como \"near-surface mounted\" (NSM), de modo a incorporar à ligação novos elementos resistentes à tração. Para solidarizar a ligação e possibilitar a transferência de esforços de compressão entre os elementos de concreto existentes, preenchem-se os espaços vazios (grauteamento) com argamassa fluida à base de cimento Portland. Foram desenvolvidos modelos em escala reduzida, com o intuito de representar os mecanismos resistentes de uma ligação viga-pilar composta por encaixe de dente Gerber e consolo, com uso de chumbador, almofada de apoio e graute. Esse tipo de ligação é muito utilizado na construção de galpões e tem, na sua concepção original, comportamento essencialmente de articulação. Em uma etapa preliminar, realizaram-se ensaios para a caracterização da aderência segundo a configuração de reforço proposta. Os resultados dessa análise subsidiaram a fixação do comprimento de laminado a ancorar e a escolha do tipo de resina a empregar para colagem do reforço. Os modelos representativos da técnica de reforço proposta foram preparados, cada um deles, pela montagem de um elemento de pilar-consolo com elementos de viga nos respectivos chumbadores e almofadas. Foram também preparados modelos de referência para o estudo da influência da almofada de apoio e do grauteamento no comportamento resistente e da deformabilidade da ligação. Nesses modelos, as juntas eram perfeitamente conjugadas, isto é, os trechos de viga foram concretados com um elemento pré-moldado de pilar-consolo posicionado dentro da fôrma, sem disposição de almofadas. Todos os modelos de ligação foram reforçados e submetidos a ensaios estáticos. Esses ensaios consistiram na aplicação de carregamento cíclico alternado de curta duração, solicitando-se os modelos a momento fletor positivo ou negativo. Este trabalho também apresenta procedimento executivo de ensaios dinâmicos para avaliação da rigidez dos modelos de ligação em três condições: modelo íntegro reforçado, modelo reforçado fissurado (após aplicação de carregamento de aproximadamente 30% do carregamento de ruptura da ligação, em ensaio estático) e modelo reforçado rompido. Com o reforço, a ligação apresentou comportamento semi-rígido e adquiriu resistência à flexão compatível à de estrutura monolítica armada com barras de PRF. / This work presents the development of a technique for flexural strengthening and stiffness increasing of precast beam-to-column connections by the embedding of FRP strips into grooves made on the concrete cover. According to this technique, the tension in the connection is transferred by the Near-Surface Mounted (NSM) FRP strips. To allow the transference of compression efforts among the concrete elements, the empty spaces are filled out with grout. Small-scale specimens were developed to represent the resistant mechanisms of pined beam-to-column connection composed by elastomeric cushion and dowels. Preliminary experimental tests on bond behavior of NSM strips were carried out. The results analysis conducted the decision about the adhesive type and bond length to be employed in the beam-to-column connection specimens. Each specimen was made of the assembly of a column section connected to beam sections through their respective dowels and cushions. The connection specimens were reinforced by embedding CFRP strips in the lateral concrete cover and filling out the spaces between beams and column. In addition, control specimens were prepared to study the influence of the cushion and grout in the connection performance. In those models, the joints were conjugated perfectly, which means that the beam sections were laid inside the wooden forms and cast together with a precast column section with no cushions between them. Experimental static and dynamic tests were done. The tests results show that strengthened connection exhibits semi-rigid behavior and acquires flexural strength compatible to monolithic structure reinforced with FRP bars.
118

Estudo teórico-experimental da ligação entre pilares mistos preenchidos e vigas pré-moldadas de concreto / Experimental and theoretical study of precast concrete beam to concrete-filled steel tube column connection

Leonardo Melo Bezerra 27 May 2011 (has links)
Neste trabalho, ligações entre vigas pré-moldadas de concreto e pilares mistos preenchidos foram propostas com a finalidade de transferir momento de flexão e força cortante das vigas para os pilares mobilizando os núcleos de concreto. Foi realizado um estudo numérico-experimental das ligações onde foi avaliada a viabilidade e a eficiência destas na transferência dos esforços. Em uma primeira fase, modelos compostos por pilar misto e consolo metálico (modelos 1 e 2) foram confeccionados, testados experimentalmente e modelados numericamente (método dos elementos finitos) para avaliar a eficiência do consolo na transferência da força cortante. Observou-se que a transferência da força cortante do consolo para o tubo metálico foi eficaz. O consolo se comportou de maneira previsível e suportou cargas elevadas. O uso de conectores de cisalhamento internos aos pilares aumentou a capacidade de carga e o desempenho dos mesmos. Na etapa seguinte da pesquisa foram confeccionados dois modelos, compostos por: pilar, viga pré-moldada, laje e consolo formando pórticos. Em um destes modelos (modelo 4) uma caixa metálica foi incorporada à viga pré-moldada e parafusado ao consolo metálico com a finalidade de transferir os momentos positivos, enquanto que outro modelo foi confeccionado e estudado sem este elemento (modelo 3). Nestes modelos foi avaliada a capacidade de transferência do momento de flexão (positivo e negativo) e forças cortantes com a ligação submetida a ciclos de carga. No modelo 3, a ligação transferiu de forma eficiente o momento negativo, porém o desempenho para o momento positivo não foi satisfatório, com baixa resistência e rigidez ao longo dos ciclos de carga. No modelo 4 foi observado considerável aumento da resistência e rigidez se comparado com o modelo anterior. Entretanto, a caixa metálica incorporada à viga pré-moldada não foi capaz de fazer com que a ligação resistisse aos momentos positivos como a mesma eficiência que resistiu aos negativos e houve degradação de suas características estruturais ao longo dos ciclos de carga. / In this work, connections of precast concrete beam to concrete-filled steel tube column were proposed to transfer the bending moment and shear forces from the beam to the composite column, mobilizing the concrete core. Was performed a numerical and experimental study of the proposed connections to evaluate the feasibility and effectiveness of them in the transfer of bending and shear forces from the beam to the column. In a first stage, models composed by column and steel corbel (models 1 e 2) were numerically and experimentally tested aiming the efficiency of the connection in shear transfer. It was observed that the transfer of shear to the steel tube was guaranteed. The corbel behaved in a predictable way and supported high loads. The use of shear connectors in the column increased the load capacity and improved the connection performance. In next stage of the research work, two models were prepared, composed by: column, precast concrete beam, steel corbel and slabs constituting frames. In one of these models (model 4) a steel box was incorporated into the precast beam and bolted to the steel corbel in order to transfer the positive moments, whereas another model was built and studied without this device (model 3). In this models were evaluated the efficiency in the transfer of bending moments (positive and negative) and shear forces with the models subjected to a cyclic loads. In the model 3, the connection transferred efficiently the negative bending, but the performance for the positive bending was not satisfactory, with reduced strength and stiffness over the load cycles. In model 4 was observed considerable increase in strength and stiffness compared with the previous model. However, the device incorporated in the precast beam was unable to make the connection resist to the positive moments with the same efficiency observed when subjected to the negative moments and a degradation of their structural characteristics was observed during the loading cycles.
119

Estudo teórico-experimental de ligação viga-pilar com almofada de argamassa e chumbador para estruturas de concreto pré-moldado / Theoretical and experimental study of beam-to-column connection with pad of mortar and bolts for precast concrete structures

Fábio Yoshio Sawasaki 05 May 2010 (has links)
As ligações com chumbador e almofada, sem continuidade estrutural, são comumente empregadas em obras de concreto pré-moldado como galpões, edifícios de poucos pavimentos e no topo de pilares. Na análise estrutural, este tipo de ligação é caracterizado como articulado. Este trabalho teve como objetivo fazer um estudo com este tipo de ligação levando em conta que a transferência de momento fletor ocorrerá em função da rigidez proporcionada por uma almofada de compósito de argamassa e por chumbadores de aço. A idéia é considerar o benefício da redução das solicitações nos elementos de concreto pré-moldado, particularmente, na base dos pilares. A análise experimental foi feita com modelos em escala reduzida 1:2. Foram ensaiados quatro modelos da ligação que são: a) Modelo 1 - chumbadores de aço CA-25 e almofada de compósito de argamassa; b) Modelo 2 - chumbadores de aço CA-25 e almofada de policloropreno; c) Modelo 3 - chumbadores de aço CA-50 e almofada de compósito de argamassa e; d) Modelo 4 - chumbadores de aço CA-50 e pilar com largura igual a 50% maior que os casos anteriores e almofada de argamassa. Foi feita ainda a análise numérica tridimensional dos modelos da ligação utilizando o software Ansys e análises de pórtico plano para avaliar a distribuição de solicitações ao longo de estruturas representativas. Foi desenvolvido um modelo de projeto para prever o comportamento da ligação. Com as simulações de pórtico plano, onde foram consideradas as semirigidezes das ligações, obteve-se uma redução de até 48% do momento fletor na base dos pilares para um edifício de quatro pavimentos, cujas ligações viga-pilares apresentavam um consolo de 40 cm, e de 21,8% para um edifício de um pavimento do tipo galpão, cujas ligações continham quatro chumbadores, considerando apenas a carga de frenagem. A análise de deslocamentos nos pórticos planos também aponta o benefício da consideração da semirigidez nas ligações. Uma redução de deslocamento horizontal do topo do pórtico do tipo galpão de até 32,8% para o modelo com ligações com quatro chumbadores e somente força horizontal, e de até 71,9% para o edifício de quatro pavimentos considerando as ligações semirígidas com consolos de 40 cm. / Connections with bolts and pad, without structural continuity, are commonly used in construction of precast concrete as one-storey building, building with a few storeys and on top of columns. In structural analysis, this type of connection is characterized as pinned, that is, without restriction of the rotation on the connection. This work aims to make a study of this type of connection taking into account that the transfer of bending moment will occur due to the stiffness provided by a pad of mortar composite and the steel bolts. The idea is to consider the benefit of reducing the demands on the elements of precast concrete, particularly at the base of the columns. The experimental analysis was done with models scale 1:2. Four models of connection were tested: a) Model 1 - steel bolts CA-25 and pad of mortar composite, b) Model 2 - steel bolts CA-25 and chloroprene rubber pad, c) Model 3 - bolts of CA-50 steel and pad of mortar composite, and d) Model 4 - steel bolts CA-50 and column with a width of 50% larger that the others and mortar pad. It was still a three-dimensional numerical analysis of the lead models using Ansys software and frame plan analysis to evaluate the stress distribution along the representative structures. A model design to predict the behavior of the connection was developed. Based on the numerical simulations on precast concrete frames, semi-rigidity of connections was take in to account, it was obtained a reduction of up to 48% of the bending moment at the base of the columns of a four-storey building, which beam-to-column connections had a corbel 40 cm, and 21,8% for a one-storey building, which connections contained four bolts, considering only the horizontal load. The analysis of displacements in the plane frame also shows the benefit of considering the semi-rigidity connections. Reduction in horizontal displacement of the top of the one-storey building to 32,8% for the model with four bolts in the connections with only horizontal force, and 71,9% for the four-storey buildings with semi-rigid connections considering the corbels of 40 cm.
120

Análise experimental de pilares de concreto armado submetidos à flexo-compressão, reforçados com comcreto auto-adensável e chumbadores / EXPERIMENTAL ANALYSIS OF REINFORCED CONCRETE COLUMNS SUBMITTED TO FLEXURAL COMPRESSION, STRENGTHENED SELF COMPACT CONCRETE AND ANCHORS

SAHB, Keyla Fabrícia Pereira 28 October 2008 (has links)
Made available in DSpace on 2014-07-29T15:03:36Z (GMT). No. of bitstreams: 1 pretext.pdf: 126548 bytes, checksum: 75b886ac104c5eb27a1e4f83ca04924f (MD5) Previous issue date: 2008-10-28 / The reinforced concrete structures are subject to interference from many factors that affect its stability and its performance and may generate the need for interventions and eventual reinforcement. There are several techniques of enhancing that can be employed and in the case of columns, the increase of the section with reinforced concrete is quite usual. This type of enhancement requires the attendance requirements to ensure its effectiveness, among which stand out in importance: meeting the needs and characteristics of project, the appropriate sizing, and the adhesion between concrete of different ages. Although the reinforcement of structures involve risk situations, and in many cases, are costly and uncertain, does not exist in the country a specific normalization for their specific design and implementation, thus they have been executed considering the normative disposals for project and execution of structures of armed concrete and in personal experiences. This research was evaluated the behavior of reinforced concrete columns required to flexural compression, with an initial section of 120 mm x 250 mm and height of 2000 mm in the compressed section and enhanced with a layer of 35 mm of self compact concrete and anchors. Was varied the amount of anchors and kept the other variables such as the concrete strength of the original columns and the enhanced columns, the initial rate of reinforcement, the eccentricity of the load test, the thickness of the reinforcement and the preparation of the substratum method. The strengthened columns had presented increasing load by increasing the amount of anchors used in the interface between the concrete of different ages. The improvement in the performance of the interface was observed, slowing the sputting and in one case, the column with a larger amount of anchors, with the crushing of concrete and sputting, almost simultaneously. There was a reduction of displacements caused by the decrease in ductility. These evidences indicate that the adopted technique of reinforcement if showed efficient, promoting consolidation of the composed section better / As estruturas de concreto armado estão sujeitas à interferência de diversos fatores que alteram sua estabilidade e seu desempenho podendo gerar a necessidade de intervenções e eventualmente reforço. Diversas são as técnicas de reforço que podem ser empregadas e, no caso dos pilares, o aumento da seção com concreto armado é bastante usual. Esse tipo de reforço exige o atendimento a requisitos que garantam a sua eficácia, dentre os quais se destacam em importância: o atendimento às necessidades e características de projeto; o adequado dimensionamento; e a aderência entre concretos de diferentes idades. Apesar de o reforço de estruturas envolver situações de risco e, em muitos casos, ser oneroso e incerto, não existe no país uma normalização específica para seu projeto e execução; assim têm sido executados considerando as disposições normativas para projeto e execução de estruturas de concreto armado e em experiências pessoais. Nesta pesquisa foi avaliado o comportamento de pilares de concreto armado solicitados à flexo-compressão reta, com uma seção inicial de 120 mm x 250 mm e altura de 2000 mm e reforçados na região comprimida com uma camada de 35 mm de concreto auto-adensável e chumbadores. Foi variada a quantidade de chumbadores e mantidas as demais variáveis como: as resistências dos concretos dos pilares originais e do reforço, a taxa de armadura inicial, a excentricidade de ensaio do carregamento, a espessura da camada de reforço e o método de preparação do substrato. Os pilares reforçados apresentaram ganhos crescentes de carga com o aumento da quantidade de chumbadores utilizada na interface entre os concretos de diferentes idades. Foi observada melhora no desempenho da interface, retardando o desplacamento e em um dos casos, no pilar com maior quantidade de chumbadores, ocorrendo o desplacamento e esmagamento do concreto quase simultaneamente. Houve redução dos deslocamentos horizontais dos pilares, provocada pela diminuição da ductilidade. Estas evidências indicam que a técnica de reforço adotada se mostrou eficiente, promovendo melhor consolidação da seção composta

Page generated in 0.0425 seconds