Análise e dimensionamento de pórticos mistos aço-betãoGuimarães, Jorge Agostinho Teixeira January 2009 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Estruturas). Faculdade de Engenharia. Universidade do Porto. 2009
|
2 |
Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubesDe Nardin, Silvana 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.
|
3 |
Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubesSilvana De Nardin 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.
|
4 |
S?ntese e caracteriza??o de argilas pilarizadas com pilares mistos Al/Co / Clays. Pillaring. Al/Co mixed pillars. Layer double hydroxideBertella, Francine 22 May 2014 (has links)
Made available in DSpace on 2014-12-17T15:42:15Z (GMT). No. of bitstreams: 1
FrancineB_DISSERT.pdf: 3873354 bytes, checksum: 665d87a2180d2517b91bf821d327dc87 (MD5)
Previous issue date: 2014-05-22 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / Two pillaring methods were tested to synthesize pillared clays containing mixed Al/Co
pillars. Using the first method, based on the traditional procedure, were obtained materials
containing different Co concentrations: 10, 25, 50, 75 and 100 % of Co in the pillaring
solution. Just the experiments with low concentrations (10 and 25 % of Co) has formed
pillared clays, whereas the sample with 25 % of cobalt showed best results compared with the
one obtained just using Al as pillaring agent (basal spacing higher than 18 ? and surface area
bigger than 300 m?/g). The 27Al NMR results pointed out the formation of mixed Al/Co pillars
due to decreased between the intensities of AlVI/AlIV signals, indicating that the AlIV content
decreased while Co content increased, suggesting the isomorphic substitution of Al atoms for
Co in the Keggin ion structure (pillaring agent). For the samples containing 75 and 100 % of
cobalt, it was verified the formation of others materials, which could be identified as
hydrotalcite like compounds. The second pillarization method was named mixed layers,
because the objective was to intercalate clay layers with hydrotalcite layers. Thus, after
calcination, the hydrotalcite layers would dehydroxylate, resulting just in the metals oxides,
intercalated between the clay sheets, thus generating, a pillared clay. For this purpose, were
tested 4 synthesis procedures: physical mixture, mixture in water, ionic exchange under reflux
and in situ synthesis. Of these, the method which showed the best results was the in situ
synthesis, in which basal spacings of 14 ? (after calcination) were obtained, indicating that
the samples are intercalated with metal oxides (Mg and Al). This procedure was reproduced
with a Co-Al LDH (layered double hydroxide) and similar results were obtained, testifying
the method reproducibility / Dois m?todos de pilariza??o de argilas foram testados a fim de se obter argilas pilarizadas
com pilares mistos Al/Co. Utilizando o primeiro m?todo, baseado no procedimento
tradicional, foram obtidos materiais contendo diferentes teores de Co: 10, 25, 50, 75 e 100 %
de Co na solu??o pilarizante. Apenas os m?todos contendo baixos teores (10 e 25 % de Co)
resultaram na forma??o de argilas pilarizadas, sendo que, a amostra contendo 25 % de cobalto
apresentou resultados superiores aos obtidos apenas com Al (espa?amento basal acima de 18
? e ?rea espec?fica BET maior que 300 m?/g). Os resultados de RMN de 27Al indicaram a
forma??o de pilares mistos Al/Co devido ? diminui??o entre as intensidades dos sinais
AlVI/AlIV, indicando que o teor de AlVI diminuiu conforme ocorreu o aumento do teor de Co,
sugerindo a substitui??o isom?rfica de ?tomos de Al por Co na estrutura do ?on de Keggin
(agente pilarizante). Para as amostras contendo 75 e 100 % de cobalto, verificou-se a
forma??o de outros materiais, os quais foram identificados como sendo compostos do tipo
hidrotalcita. O segundo m?todo de pilariza??o foi chamado de lamelas mistas, pois o objetivo
era intercalar lamelas de argila com lamelas de hidrotalcita, assim ap?s a calcina??o, ocorreria
a desidroxila??o da camada de HDL (hidr?xido duplo lamelar), resultando apenas nos ?xidos
de metais, intercalados entre as lamelas da argila, gerando uma argila pilarizada. Para tal,
foram testados 4 procedimentos de s?ntese: mistura f?sica, mistura em ?gua, troca i?nica em
refluxo e s?ntese in situ. Desses, o m?todo que apresentou os resultados mais promissores foi
o de s?ntese in situ, no qual espa?amentos da ordem de 14 ? (ap?s calcinar) foram obtidos,
indicando que as amostras est?o intercaladas com ?xidos de metais (Mg e Al). Esse
procedimento foi reproduzido com uma HDL contendo Co-Al, e resultados semelhantes
foram obtidos, comprovando a reprodutibilidade do m?todo
|
5 |
[en] EXPERIMENTAL STUDY ON THE BEHAVIOR OF COMPOSITE COLUMNS SUBJECTED TO COMPRESSION AND BENDING / [pt] ESTUDO EXPERIMENTAL DO COMPORTAMENTO DE PILARES MISTOS SUJEITOS A FLEXO-COMPRESSÃOFABIANA FREITAS NOGUEIRA 15 December 2003 (has links)
[pt] Pilares mistos são pilares compostos de perfis metálicos,
concreto e vergalhões. Um tipo destes pilares é aquele em
que um perfil metálico fechado é preenchido com concreto
armado, que é o tipo de pilar adotado neste trabalho. Uma
de suas vantagens é a facilidade de execução. O objetivo
deste trabalho é estudar experimentalmente o comportamento
dos pilares mistos quando sujeitos à flexão-compressão.
Inicialmente foi realizada uma série de ensaios em corpos
de prova mistos com a finalidade de se obter a curva tensão-
deformação do concreto confinado. Em seguida foram
realizados 15 ensaios de pilares mistos onde as variáveis
estudadas foram o comprimento de flambagem do pilar, a
excentricidade da carga e a taxa de armadura. Os resultados
experimentais foram comparados com as resistências
calculadas de acordo com os métodos propostos nas normas
técnicas NBR 14323 e no EuroCode 4. De uma forma geral,
todos os métodos de cálculo forneceram bons resultados. / [en] Composite columns are a structural members subjected to
compression and bending, made of concrete and structural
steel. One particular type of composite column consists of
rectangular steel hollow sections completely filled with
concrete and reinforcing bars, which is the type of column
considered in this work. One of the advantages of this
column is the construction facility. The objective of this
work is to study experimentally the behaviour of composite
columns when subjected to combined compression and bending.
Initially a series of tests of composite specimens was
carried out in order to obtain the stress-strain curve for
the concrete confined by the steel section. Following that,
15 composite columns were tested with the purpose of
studying the effect of the buckling length, load
eccentricity and reinforcement ratio on the column strength.
The experimental results were compared to theoretical
resistances calculated by the NBR 14323 and EuroCode 4 Code
Requirements. In general, a good agreement was found
between the experimental and theoretical results.
|
6 |
[pt] MODELAGEM DO COMPORTAMENTO DE PILARES MISTOS DE SEÇÃO COMPOSTA PREENCHIDOS COM CONCRETO ARMADO / [en] MODELING THE BEHAVIOR OF COMPOSITE BEAM-COLUMNS COMPOSED OF BUILT-UP SECTIONS FILLED WITH REINFORCED CONCRETEGABRIEL AMOS ALVES CRUZ LIMA 21 January 2021 (has links)
[pt] A obtenção de estruturas mais resistentes e rígidas, e economicamente
viáveis, é uma preocupação cada vez maior na construção civil. Sob essa ótica,
este trabalho tem o objetivo de avaliar o comportamento de pilares mistos de
seção composta através de uma modelagem numérica. Foram estudados dois
tipos de seções, uma composta por dois perfis I laminados, e outra por dois perfis
U enrijecidos, em ambos os casos conectados por perfis I e preenchidos com concreto
armado. Com o uso do software ABAQUS, foi avaliado o comportamento
estrutural dos elementos submetidos a carregamentos de flexão, compressão e
flexo-compressão. O modelo foi validado através da comparação com dados
experimentais de estudos anteriores e resultados previstos pela norma técnica
brasileira, conseguindo representar adequadamente o comportamento das curvas
momento-deslocamento e força-deslocamento. As resistências obtidas a partir
dos modelos numéricos foram superiores aos valores esperados pela solução
teórica, principalmente no carregamento de compressão. De modo a avaliar a
viabilidade econômica do sistema misto proposto, foi realizado o dimensionamento
de um galpão industrial, que evidenciou ganho significativo de inércia
em relação a um sistema composto apenas por perfis de aço, resultando em uma
economia de até 11 por cento na massa equivalente em aço. Por fim, desenvolveu-se um
estudo paramétrico para investigar a influência do número de conectores, da sua
disposição, da resistência do concreto e do diâmetro da armadura na resistência
do pilar. / [en] A growing concern in civil construction is to obtain structures that are
more resistant, rigid and economically feasible. This study aims to evaluate
the behavior of steel-concrete columns of composite section, through numerical
modeling. The studied cross-sections were composed of two rolled I profiles,
and other with C-lip channels, connected by I profiles, and filled with reinforced
concrete. The ABAQUS software was used to evaluate the structural behavior of
the columns subjected to flexural, compression and eccentric compression loads.
The model was calibrated through experimentally obtained data from previous
studies, and results provided by the Brazilian National Standards, and it was able
to properly reproduce the moment-displacement and load-displacement curves.
The obtained resistances from the numerical models were greater than the ones
expected by the theoretical solution, especially under compression load. In order
to evaluate the economic feasibility of the proposed composite model, a design
example of an industrial shed was conducted, and it showed a significant increase
in moment of inertia when compared to steel-only box sections, which resulted in
savings of up to 11 percent in equivalent mass of steel. Finally, a parametric study was
made to investigate the influence of the number and disposition of the connectors,
and the contribution of the concrete resistance and reinforcement s diameter in
the strength of the columns.
|
7 |
Sobre o projeto de edifícios em estrutura mista aço-concreto / On the design of buildings with composite structuresAlva, Gerson Moacyr Sisniegas 27 April 2000 (has links)
Este trabalho apresenta uma abordagem abrangente das estruturas mistas aço-concreto, com ênfase em edifícios, e dos principais elementos que compõem esse sistema: as vigas mistas, simplesmente apoiadas e contínuas, as lajes mistas e os pilares mistos. São abordados os aspectos construtivos, o comportamento estrutural e os procedimentos para dimensionamento recomendados pelas principais normas aplicáveis, enfatizando a norma norte-americana do AISC e o EUROCODE 4. O projeto em situação de incêndio também é analisado, considerando o comportamento e o dimensionamento de elementos mistos frente à ação do fogo. No final, são desenvolvidos exemplos de dimensionamento, onde procura-se comparar e discutir os resultados obtidos pelas principais normas / This study consists of a broad analysis of composite structures, with particular emphasis on buildings, and the principal elements that make up this system, i.e., continuous and simply supported composite beams, composite slabs and composite columns. Several aspects of construction are broached, as well as structural behavior and the procedures for design recommended by the main codes, mainly the American AISC and the EUROCODE 4 codes. Fire design is also analyzed, considering the behavior and design of composite elements under fire conditions. The study concludes with some examples of design, comparing and discussing the results achieved by the principal codes
|
8 |
[en] EXPERIMENTAL STUDY OF COMPOSITE BEAM-COLUMNS WITH HIGH STRENGTH STEEL SECTIONS / [pt] ESTUDO EXPERIMENTAL DO COMPORTAMENTO DE PILARES MISTOS COM PERFIS DE AÇO DE ALTA RESISTÊNCIADAIANA SANTOS ERINGER 16 May 2018 (has links)
[pt] Estruturas mistas de aço e concreto estão se tornando cada vez mais viáveis do ponto de vista de execução com custos mais competitivos. Graças às pesquisas e aos estudos desenvolvidos que visam aproveitar ao máximo as vantagens oferecidas pelos materiais concreto e aço, as estruturas mistas vêm sendo cada vez mais utilizadas na construção civil. Neste estudo são apresentadas as configurações estruturais dos pilares mistos e recomendações de projeto de normas vigentes. O objetivo dessa dissertação é avaliar o comportamento experimental de pilares mistos com perfis de aço de alta resistência submetidos a ensaios em escala real. Para tal avaliação, levou-se em consideração as características e propriedades dos materiais que compõem as peças: concreto, aço das armaduras e aço de alta resistência dos perfis U de chapa dobrada. Para atingir o objetivo deste trabalho, foram testados seis elementos mistos com seção transversal formada por dois perfis U de chapa dobrada e concreto armado, formando uma seção retangular. Inicialmente duas colunas foram submetidas à compressão centrada e duas vigas foram testadas à flexão. Posteriormente os dois pilares mistos foram ensaiados com excentricidade de 40 mm no carregamento. Os resultados experimentais foram, então, analisados e comparados com os resultados teóricos calculados com as recomendações da norma brasileira ABNT NBR 8800:2008 e do Eurocode 4, 2004. E os resultados experimentais foram em média coerentes com os teóricos calculados. / [en] Composite structures of steel and concrete are becoming increasingly feasible from the execution point of view, with more competitive costs. Thanks to the work and studies developed that aim to make the most of the advantages offered by both materials, they have been increasingly used in building construction. This study presents the structural configurations of the composite beam-columns and design recommendations using current codes. The objective of this dissertation is to evaluate the experimental behavior of composite beam-columns with high strength steel profiles tested in real scale specimens. For this analysis, the characteristics and properties of the materials that compose the structure were taken into consideration: concrete, reinforcing steel and high strength steel of the cold formed sections. To reach the aims of this work, six composite elements with cross section formed by two channel profiles of folded sheet and reinforced concrete were tested. Initially two columns were subjected to centered compression and two beams were subjected to flexural tests. Subsequently, the composite beam-columns were tested with a 40 mm eccentricity at loading. The experimental results were then analyzed and compared with the theoretical ones, which were calculated with the recommendations of the Brazilian standard ABNT NBR 8800:2008 and the Eurocode 4, 2004. The experimental results, obtained were consistent with the theoretical predictions.
|
9 |
Sobre o projeto de edifícios em estrutura mista aço-concreto / On the design of buildings with composite structuresGerson Moacyr Sisniegas Alva 27 April 2000 (has links)
Este trabalho apresenta uma abordagem abrangente das estruturas mistas aço-concreto, com ênfase em edifícios, e dos principais elementos que compõem esse sistema: as vigas mistas, simplesmente apoiadas e contínuas, as lajes mistas e os pilares mistos. São abordados os aspectos construtivos, o comportamento estrutural e os procedimentos para dimensionamento recomendados pelas principais normas aplicáveis, enfatizando a norma norte-americana do AISC e o EUROCODE 4. O projeto em situação de incêndio também é analisado, considerando o comportamento e o dimensionamento de elementos mistos frente à ação do fogo. No final, são desenvolvidos exemplos de dimensionamento, onde procura-se comparar e discutir os resultados obtidos pelas principais normas / This study consists of a broad analysis of composite structures, with particular emphasis on buildings, and the principal elements that make up this system, i.e., continuous and simply supported composite beams, composite slabs and composite columns. Several aspects of construction are broached, as well as structural behavior and the procedures for design recommended by the main codes, mainly the American AISC and the EUROCODE 4 codes. Fire design is also analyzed, considering the behavior and design of composite elements under fire conditions. The study concludes with some examples of design, comparing and discussing the results achieved by the principal codes
|
10 |
[pt] ESTUDO EXPERIMENTAL DO COMPORTAMENTO DE ELEMENTOS MISTOS CONSTITUÍDOS DE PERFIS DUPLO I PREENCHIDOS COM CONCRETO ARMADO / [en] EXPERIMENTAL STUDY OF THE BEHAVIOR OF COMPOSITE MEMBERS COMPOSED OF DOUBLE I SECTIONS FILLED WITH REINFORCED CONCRETERODRIGO POMPERMAYER SOARES 09 March 2021 (has links)
[pt] Nesta dissertação, foi desenvolvido um estudo experimental de um sistema de pilares mistos. O modelo estrutural consiste em dois perfis I laminados ligados por conectores soldados na região das almas, e com concreto armado preenchendo a região entre os perfis. Além dos conectores ligando as almas dos perfis principais do pilar, também se têm a presença de conectores do tipo stud bolt soldados nas almas, permitindo maior interação aço-concreto e evitando a flambagem de alma. Neste trabalho, são apresentados os detalhes do sistema construtivo, evidenciando a melhor maneira de executar a fabricação do sistema misto, assim como as recomendações de projeto. Com base em resultados teóricos iniciais e nos custos inerentes à produção do sistema, desenvolveu-se um programa experimental no Laboratório de Estruturas e Materiais da PUC-Rio. Este programa experimental teve como objetivo avaliar o comportamento estrutural do sistema proposto quando sub-metido à flexão, determinar o comportamento carga x deslocamento da estrutura, a carga última de plastificação da estrutura, as dificuldades de montagem do sistema, assim como o custo benefício ao levar em conta todos os processos realizados. / [en] In this work, an experimental study on a new composite column system is developed. It consists on a double I section column connected by the webs and filled with reinforced concrete between the I sections. It also includes stud bolt connectors welded to the webs, allowing a higher steel-concrete interaction and avoiding web buckling. Throughout this work, details on the best way to fabricate the system will be provided and also project recommendations will be given. An experimental programme was developed at the Structures and Materials Laboratory of PUC-Rio. The objective of this programme was to evaluate the structural behaviour of the proposed system when submitted to a bending test, determining its load vs displacement behaviour, the ultimate plastic load, the difficulties of fabrication and the cost-benefit after considering all of the steps developed.
|