• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Design of Composite Stainless Steel Concrete Filled Columns

Lam, Dennis, Gardner, L. January 2007 (has links)
No / This paper presents the behaviour and design of axially loaded concrete filled stainless steel circular and square hollow sections. The experimental investigation was Conducted using different concrete cube strengths varied from 30 to 100 MPa. The column strengths and load-axial shortening curves were evaluated. The study is limited to cross-section capacity and has not been validated at member level. Comparisons of the tests results together with other available results from the literature have been made with existing design methods for composite carbon steel sections-Eurocode 4 and ACI. It was found that existing design guidance for carbon steel may generally be safely applied to concrete filled stainless steel tubes. though it tends to be over-conservative. A continuous strength method is proposed and it is found to provide the most accurate and consistent prediction of the axial capacity of the composite concrete filled stainless steel hollow sections due largely to the more precise assessment of the contribution of the stainless steel tube to the composite resistance.
2

Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubes

De Nardin, Silvana 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.
3

Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubes

Silvana De Nardin 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.

Page generated in 0.031 seconds