• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 575
  • 35
  • 21
  • 8
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 641
  • 237
  • 138
  • 106
  • 95
  • 94
  • 93
  • 89
  • 76
  • 74
  • 73
  • 55
  • 54
  • 52
  • 47
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estimativa de deformações por observações geodésicas associadas a eventos sísmicos na área de abrangência da Rede Sirgas-CON

Marotta, Giuliano Sant'Anna 25 March 2013 (has links)
Tese (doutorado)—Universidade de Brasília, Instituto de Geociências, Curso de Pós-Graduação em Geociências Aplicadas, 2013. / Submitted by Luiza Silva Almeida (luizaalmeida@bce.unb.br) on 2013-07-31T15:08:17Z No. of bitstreams: 1 2013_ GiulianoSant'AnnaMarotta.pdf: 4457661 bytes, checksum: 9a140863dbb2c321635f7aee8bbe5071 (MD5) / Approved for entry into archive by Leandro Silva Borges(leandroborges@bce.unb.br) on 2013-07-31T20:38:08Z (GMT) No. of bitstreams: 1 2013_ GiulianoSant'AnnaMarotta.pdf: 4457661 bytes, checksum: 9a140863dbb2c321635f7aee8bbe5071 (MD5) / Made available in DSpace on 2013-07-31T20:38:08Z (GMT). No. of bitstreams: 1 2013_ GiulianoSant'AnnaMarotta.pdf: 4457661 bytes, checksum: 9a140863dbb2c321635f7aee8bbe5071 (MD5) / Neste estudo, foram investigadas as deformações que ocorrem na superfície terrestre utilizando dados oriundos de observações geodésicas, geológicas e sismológicas. Primeiramente, foram estudadas as deformações entre períodos pré e pós-sísmico na América Latina, por meio da análise das variações dos valores de coordenadas terrestres estimadas por técnicas de posicionamento GNSS em uma rede denominada SIRGAS-CON. Baseando-se nos dados de 23 eventos sísmicos extraídos do USGS para o período de 2000-2011 e após aplicação do teste de Congruência Global na rede geodésica, foram identificados quatro eventos associados a pontos geodésicos instáveis, com deslocamentos dos pontos entre aproximadamente 1 cm e 3 m. Após o cálculo das deformações e da verificação dos resultados, para os quatro eventos selecionados, foi possível analisar as interações entre diferentes placas litosféricas pelas direções de contração e extensão estimadas. Porém, não foi possível relacionar deformações na rede geodésica com eventos sísmicos. Posteriormente, por meio de uma solução multianual da rede SIRGASCON, foram investigadas as taxas de deformação da superfície terrestre estimadas a partir das variações de direção dos vetores de velocidade de 140 pontos geodésicos localizados na placa Sul Americana. A partir dos resultados, foi possível sugerir que, na porção oeste da placa a deformação é mais significativa, tal como esperado, pois a região está próxima à zona de subducção da placa de Nazca sob a placa Sul Americana. Utilizando vetores de Euler, para inferir o movimento da placa de Nazca, foi possível estimar as taxas de convergência da placa de Nazca e a taxa que é absorvida pela placa Sul Americana. Por fim, foram estimadas as deformações na Província Borborema, localizada na região nordeste do Brasil. Para isto, foram utilizadas estações de rastreio com mínimo de 2 anos de dados provenientes da RBMC e da rede denominada GPS Potiguar, mantido pelo Departamento de Geologia da UFRN. Os dados foram processados utilizando o software GIPSY versão 6.2, disponibilizado pelo JPL do Instituto de Tecnologia da Califórnia, e o método utilizado foi o PPP. A partir de uma solução anual onde as coordenadas e velocidades foram estimadas com suas devidas precisões, foram calculadas as taxas de deformação utilizando a triangulação de Delaunay e o método de Elementos Finitos. As deformações foram comparadas com dados de esforços da região, obtidos por estudos geológicos (breakouts) e sismológicos (mecanismos focais) coletados em bibliografias existentes e foi possível sugerir correlação entre eles. Foi possível com os estudos realizados: correlacionar a interação dos esforços tectônicos aplicados nas placas analisadas com movimentos observados na superfície terrestre; identificar, do ponto de vista geodésico, as regiões estáveis e instáveis na placa Sul Americana e; confirmar a sensibilidade da rede geodésica aos esforços aplicados na região intraplaca Sul Americana. ______________________________________________________________________________ ABSTRACT / In this study were investigated the strains that occur on the earth’s surface using data from geodesic, geologic and seismologic observations. First, the strains between pre and post seismic events in Latin America were studied, by analyzing variation of terrestrial coordinates values estimated by GNSS positioning techniques in a network called SIRGAS-CON. Based in 23 seismic events data, provided by USGS, for the period of 2000-2011, and after the Global Congruence test in the geodesic network, four events associated to instable geodesic points were identified, with points displaced from 1 cm to 3 m approximately. After the strains calculations and verification of the results for the four selected events, it was possible to analyze the interactions among different lithospheric plates by estimating contraction and extension directions. However, it was not possible to correlate strains in the seismic events on geodesic network. Second, using a multiannual solution from SIRGAS-CON network, the strain rates on earth surface estimated from the direction variation of velocity vectors in 140 geodesic points located into South American plate were investigated. From those results, it was suggested that the strain was more significant in the western portion of the plate, as thought, because the region is near to the Nazca subduction zone over the South American plate. Using Euler vectors to determinate the Nazca plate movement, it was possible to estimate the convergence rates of Nazca plate and also the rate that is absorbed by the South American plate. Tthe strains in Borborema Province, in the Brazilian northeastern region, were estimated. For that purpose, tracking stations were used with at least 2 years of data provided from RBMC and the network called GPS Potiguar, controlled by the Geology Department of UFRN. Those data were processed with the GIPSY 6.2 software, offered by the California Technology Institute, and the method was the PPP. Based on an annual solution, where the coordinates and velocities were estimated with the proper precisions, the strain rates using Delaunay’s triangulation and finite elements method were calculated. The strains were compared with of region effort data, obtained by geological (breakouts) and seismologic (focal mechanisms) data collected in bibliographic references and was possible to suggest correlation among them. From the accomplished studies it was possible: to correlate the interaction of the tectonic efforts applied on the plates analyzed from movements noticed on earth surface; to identify, from the geodesic point of view the stable and instable regions in South American plate and; to confirm the sensibility of the geodesic network to the tectonic efforts applied in South American intraplate region.
12

Análise de placas pelo método dos elementos finitos

Hennemann, Jose Carlos Ferraz January 1972 (has links)
O objetivo deste trabalho é a resolução, pelo método dos Elementos Finitos, de placas com contorno poligonal sujeitas a cargas uniformemente distribuídas e concentradas utilizando elementos triangulares e retangulares. O programa desenvolvido ex linguagem FORTRAN-IV para o computador IBM-1130, podendo, com poucas alterações, ser utilizado em qualquer outro sistema. / This paper is an application of Finite Elements Method to plates of any shape with distributed and concentrated loads usiag triangular and retangular elements. The program was developpeii in FORTRAN-IV language, for IBM-1130, and it can be used i n an other computer with a few modifications.
13

Avaliação da resistência flexural e rugosidade de resinas acrílicas termopolimerizáveis, empregadas na confecção de placas oclusais, variando técnica e tempo de polimerização / Evaluation of flexural strength and surface roughness of termopolymerized acrylic resins used to fabricate occlusal splints, varying polymerization and curing time

Maia, Alana Paula da Matta 11 February 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2014-05-21T14:02:06Z No. of bitstreams: 1 2014_AlanaPaulaMattaMaia.pdf: 1387064 bytes, checksum: f7ba951b281f5c623f7b6f76cf8a0135 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-05-23T12:23:06Z (GMT) No. of bitstreams: 1 2014_AlanaPaulaMattaMaia.pdf: 1387064 bytes, checksum: f7ba951b281f5c623f7b6f76cf8a0135 (MD5) / Made available in DSpace on 2014-05-23T12:23:06Z (GMT). No. of bitstreams: 1 2014_AlanaPaulaMattaMaia.pdf: 1387064 bytes, checksum: f7ba951b281f5c623f7b6f76cf8a0135 (MD5) / A desordem temporomandibular (DTM) é uma doença complexa, cuja natureza não está completamente esclarecida. É a maior causadora de dores faciais e possui etiologia multifatorial. Uma das principais formas de tratamento e controle da sintomatologia da DTM é a placa oclusal, comumente confeccionada em resina acrílica termopolimerizável. O objetivo desse estudo foi o de avaliar a resistência à flexão e rugosidade superficial de resinas acrílicas termopolimerizáveis em função do tempo e técnica de polimerização. Uma resina acrílica termopolimerizável pelo método convencional (Clássico - A. O. Clássico Ltda., Brasil) e duas por energia de micro-ondas (Onda Cryl – A. O. Clássico Ltda., Brasil; e VIPI WAVE - Vipi Produtos Odontológicos Ltda, Brasil) foram estudadas. Para o estudo, foram obtidas 60 amostras, distribuídas em 6 grupos (n= 10). Dos 6 grupos, 3 foram confeccionados de acordo com o tempo recomendado pelo fabricante (grupos I, III e V) e os outros 3 foram confeccionados com aumento de 50% do tempo recomendado pelo fabricante (grupos II, IV e VI). Os testes de resistência à flexão foram realizados por meio de uma máquina de ensaio universal EMIC modelo DL 3000 (EMIC – Equipamentos e Sistemas de Ensaio Ltda., São José dos Pinhais, PR, Brasil) e a análise da rugosidade superficial foi realizada por meio de um rugosímetro (Mitutoyo, Japão). Os valores obtidos foram analisados estatisticamente pela Análise de Variância de três fatores e pelo teste de Tukey a 5% de significância. Para o teste de resistência a flexão todos os grupos apresentaram diferença estatisticamente significativa, sendo a resina Clássico aquela que obteve os melhores resultados quando polimerizada pelo tempo recomendado pelo fabricante; quando o tempo de polimerização foi aumentado em 50%, apenas a resina Onda Cryl apresentou melhoras no desempenho. Para o teste de rugosidade, o único grupo que apresentou diferenças estatísticas significativas foi o grupo da resina VIPI WAVE, que quando polimerizado com aumento de 50% do tempo recomendado pelo fabricante apresentou aumento nos valores de rugosidade superficial. As variáveis tempo e técnica de polimerização influenciaram na resistência à flexão de resinas termopolimerizáveis, com diferença estatística significativa para todos os grupos. Por outro lado, as mesmas variáveis não promoveram diferenças estatisticamente significativas sobre a rugosidade superficial, com exceção do grupo da resina VIPI WAVE com tempo alterado (grupo II) em relação aos demais grupos que receberam o mesmo tratamento. Para resinas polimerizadas por energia de micro-ondas, parece haver dependência entre as variáveis potência do micro-ondas e tempo de polimerização. ______________________________________________________________________________ ABSTRACT / The temporomandibular disorder (TMD) is a complex disease whose origin is not completely clear. It is a disease that causes most of the facial pain related and its etiology is multifactorial. The most common treatment approach to the TMD is occlusal splints, and these are usually made of termopolymerized acrylic resins. The purpose of this study was to evaluate the flexural strength and superficial roughness of termopolymerized acrylic resins in function of polymerization technique and curing time. We used one termopolymerized acrylic resin for the conventional method (Clássico- A. O. Clássico Ltd, Brazil), and two for microwaves (Onda Cryl -. A. O. Clássico Ltd, Brazil; VIPI WAVE - Vipi Produtos Odontológicos Ltd, Brazil). For the study, 60 samples created 6 groups (n = 10). From the 6 groups, 3 of them were polymerized as the manufacturer proposed (groups I, III and V) and the other 3 were polymerized with an increase of 50% on the time proposed by the manufacturer (groups II, IV and VI). The analysis was obtained by the use of a universal testing machine (EMIC modelo DL 3000 (EMIC, Brazil), which performed the three point flexural tests and a roughmeter (Mitutoyo, Japan). These measures were submitted to the Analysis of Variance of three factors and Tukey test at a significance level of p = 0.05. For the three point flexural test all groups presented significative statistic differences. The resin Clássico presented the greater values when polymerized as the manufacturer recommended; on the other hand, when polymerization time was increased by 50%, only the resin Onda Cryl presented improvement in its performance. For the surface roughness test, the only group that presented statistically significant difference was the one of VIPI WAVE resin, which presented the higher values of superficial roughness when polymerization time recommended by the manufacturer was increased by 50%. We conclude that the variables time and polymerization method did influence the flexural strength of the termopolymerized resins, with statistically significant difference for all groups. To the contrary, the same variables did not show statistically significant difference on the surface roughness except for group II, which presented statistically significant difference in relation to the other groups that were submitted to the same change of protocol. There seems to be a connection between the variables time of polymerization and power of the microwave for the resins that are polymerized by this source of heat.
14

Análise de placas pelo método dos elementos finitos

Hennemann, Jose Carlos Ferraz January 1972 (has links)
O objetivo deste trabalho é a resolução, pelo método dos Elementos Finitos, de placas com contorno poligonal sujeitas a cargas uniformemente distribuídas e concentradas utilizando elementos triangulares e retangulares. O programa desenvolvido ex linguagem FORTRAN-IV para o computador IBM-1130, podendo, com poucas alterações, ser utilizado em qualquer outro sistema. / This paper is an application of Finite Elements Method to plates of any shape with distributed and concentrated loads usiag triangular and retangular elements. The program was developpeii in FORTRAN-IV language, for IBM-1130, and it can be used i n an other computer with a few modifications.
15

Efeito Casimir em Placas de Plasma e a Energia de Condensação do Supercondutor do Tipo (Hg, Pb) Ba2-xSrxCa2Cu3O8+δ.

AMORIM, L. S. 08 June 2010 (has links)
Made available in DSpace on 2018-08-01T22:29:32Z (GMT). No. of bitstreams: 1 tese_4555_.pdf: 283528 bytes, checksum: 49eb6d68ed848005fb4b7127c37cb296 (MD5) Previous issue date: 2010-06-08 / Neste trabalho é apresentada uma descrição do comportamento da temperatura crítica (Tc ) em supercondutores do tipo (Hg, Pb ) Ba2-x Srx Ca2 Cu3 O8+δ (Hg-1223). Aqui é sugerido que energia de condensação do supercondutor se dá pela energia de Casimir dos planos de CuO, considerando que estes sejam placas finas de plasma. A partir dessa hipótese chega-se a uma equação para a temperatura de transição que depende de variáveis da estrutura cristalina do supercondutor, bem como de constantes universais, e dentre essas variáveis, está o parâmetro de correção de massa efetivados pares de Cooper (α ). O objetivo aqui visado é obter uma aproximação de Tc para a família cerâmica supracitada em comparação a dados experimentais, e com valores de α arbitrariamente ajustados, mas de forma consistente e plausível.
16

Efeito da placa estabilizadora do tipo Michigan sobre a atividade eletrica dos musculos temporal anterior e masseter de pacientes com habito de bruxismo

Ferreira, Juvenil Alves Neves Diniz 02 May 2001 (has links)
Orientadores : Renata Cunha Matheus Rodrigues Garcia, Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:40:46Z (GMT). No. of bitstreams: 1 Ferreira_JuvenilAlvesNevesDiniz_M.pdf: 6172901 bytes, checksum: 80b8f53361bd5da5776d9993c5d7b5e1 (MD5) Previous issue date: 2001 / Resumo: O propósito deste estudo foi avaliar os achados eletromiográficos dos músculos temporal anterior e masseter de pacientes com hábito de bruxismo, antes e durante o uso de placas estabilizadoras do tipo Michigan. Foram avaliados dois grupos de voluntários: grupo 1 (grupo bruxista), composto de 16 pacientes bruxistas sendo que 6 eram do sexo masculino e 10 do sexo feminino com idade média de 35,68 anos (D.P.= 10,20) e grupo 2 (grupo - controle), composto de 16 voluntários as sintomáticos sendo 9 do sexo masculino e 7 do sexo feminino com idade média de 29,25 anos (D.P.= 5,27). Os voluntários do Grupo 1 fizeram uso de placas do tipo Michigan, o que não ocorreu para o Grupo 2. Entretanto, todos foram submetidos a ciclos de movimentos isotônicos (IST) de 14 segundos de duração e a contrações isométricas (ISO) com contração voluntária máxima de 5 segundos de duração. Para a avaliação da dor foi aplicada a escala visual analógica (EV A) após a contração isométrica. O exame eletromiográfico foi realizado em todos os voluntários por meio de um sistema de aquisição de sinais, com eletrodos diferenciais ativos de prata pura de superficie no interior da gaiola eletrostática de Faraday, durante os diferentes tempos (TO, TI, T2, T3 e T4). Para a análise dos dados utilizou-se o teste t para dados pareados (ao comparar a amplitude nos diferentes músculos e nos diferentes tempos além da EV A) e o teste t para duas amostras independentes (ao comparar a amplitude entre os grupos 1 e 2 e essa entre os movimentos ISO e 1ST). Os resultados mostraram que ao se comparar os Grupos 1 e 2, no movimento ISO, verificou-se que no tempo T4 as médias de amplitude dos músculos temporal esquerdo, temporal direito e masseter direito do Grupo 1 foram menores do que as do Grupo 2, para o masseter esquerdo este comportamento se deu no tempo TI. A partir dos resultados concluiu-se que a placa do tipo Michigan promoveu um significativo alívio da dor nos voluntários do Grupo I além de reduzir significativamente a amplitude do sinal eletromiográfico nos músculos mastigatórios do Grupo I durante o uso da mesma / Abstract: The aim of this study was to evaluate the electromyographic findings of temporal and masseter musc1es of patients with bruxism, before and during the use of Michigan occ1usal splints. Two groups were evaluated: Group 1 (bruxer's group), with 16 bruxers, being 6 men and 10 women, with mean age of 35.68 years (S.D.= 10.20) and Group 2 (control group), with healthy subjects, being 9 men and 7 women, with mean age of 29.25 years (S.D.= 5.27). The subjects from Group 1 used Michigan occ1usal splints, witch were not used in Group 2. However, alI the subjects were submitted to isotonic movements (1ST) of 14 seconds and to isometric contractions with maximum voluntary contraction (MVC) of 5 seconds. To evaluate the pain, an visual analogue scale (V AS) was used after the isometric contraction. AlI the subjects were electromyographicaly examined by a sign acquisition system, with silver surface electrodes inside Faraday electrostatic cages, during different periods of time (TO, TI, T2, T3 and T4). The t test was used to analyze the paired data (when comparing A VS in group 1, the amplitude in different musc1es and in different periods of time in both groups) and the t test for independent samples (when comparing the amplitude between the groups 1 and 2 and this amplitude between the ISO and 1ST movement). When comparing Groups 1 and 2 during the MVC movement, the results showed that in the period oftime T4, the amplitude means ofthe left temporal, the right temporal and the right masseter musc1es of group 1 were lower than those from Group 2. In the left masseter musc1e, this behavior occurred during the period of promoted a significant pain release in the subjects of Group 1, also significantly reducing the electromyographic amplitude sign in the mastigatory musc1es of Group 1 during its use / Mestrado / Protese Dental / Mestre em Clínica Odontológica
17

Analise mecanica e fotoelastica das tecnica de fixação interna rigida da osteotomia sagital utilizando placa convencional e placa com sistema de travamento em avanços mandibulares / Mechanical and photoelastic analysis of two methods of rigid internal fixation in mandfibular advancement

Lyrio, Mariana Camilo Negreiros, 1980- 03 June 2009 (has links)
Orientadores: Marcio de Moraes, Luciana Asprino / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T02:18:28Z (GMT). No. of bitstreams: 1 Lyrio_MarianaCamiloNegreiros_M.pdf: 2393437 bytes, checksum: f0dfbf68baaeb080347c83445d15e1e9 (MD5) Previous issue date: 2009 / Resumo: O propósito neste estudo foi realizar avaliação mecânica e fotoelástica de dois diferentes sistemas de fixação interna rígida (FIR): placas convencionais e placas com sistema de travamento. Para avaliação mecânica foi realizado teste de carregamento linear em réplicas de hemimandíbulas humanas dentadas seccionadas na região de ramo mandibular, representando uma osteotomia sagital, e fixadas com avanço mandibular de 5 mm. No grupo I a fixação foi realizada com placas convencionais e parafusos monocorticais do sistema 2,0mm e no grupo II utilizou-se placas e parafusos monocorticais com sistema de travamento do sistema 2,0 mm. Para análise estatística foram aplicados Anova e teste de Tukey em nível de significância de 5%, os quais demonstraram não haver diferenças entre os grupos I e II nos testes mecânicos. Para os testes fotoelásticos foram confeccionadas hemimandíbulas humanas dentadas em resina fotoelástica, também seccionadas simulando a osteotomia sagital e fixadas com avanço mandibular de 5 mm, com os mesmos grupos utilizados para os testes mecânicos. Em relação à distribuição de tensões, pode-se observar que as mesmas se concentram ao redor dos parafusos, principalmente naqueles próximos à área de osteotomia para ambos os grupos. Dessa forma, pode-se afirmar que os sistemas de fixação utilizando placa e parafusos convencionais ou com sistema de travamento não apresentaram diferenças estatísticas quanto à resistência, e que a maior concentração de forças está nas áreas próximas às osteotomias, consideradas regiões de maior fragilidade após a OSRM. / Abstract: The aim of this study was evaluate the mechanical and photoelastic behavior of two methods of rigid internal fixation (RIF): conventional plates and locking plates. For mechanical tests polyurethane synthetic hemimandible with seccional sagittal ramus split was used, simulating an advancement of 5 mm. The fixation performed on the Group I was a 2.0 mm conventional plates with monocortical screws and fixation used on group II was a 2.0 locking plates with monocortical locking screws. Anova and Tukey tests were applied (P<5) and no statistical differences were noted between the groups. Hemimandibles were made in photoelastic resin with same groups used in mechanical tests and submitted to photoelastical analysis. In relation to tension distribution in photoelastic analysis, the fringes were concentrated around screws, mainly in areas near the osteotomy for both groups. Based in this fact, the conventional and locking fixations systems did not present statistical differences on resistence, and the major forces was concentrated in regions near the osteotomies lines, that considered fragility before sagittal split osteotomy. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
18

Avaliação da eficácia de placas estabilizadoras com padrão de guia balanceada bilateral no controle dos desarranjos internos da ATM / EVALUATION OF THE EFFECTIVITY OF STABILIZATION SPLINTS WITH BILATERAL BALANCED GUIDANCE FOR THE CONTROL OF INTERNAL TMJ DERANGEMENTS

Carlos Neanes Santos 30 April 2003 (has links)
O objetivo deste estudo foi avaliar o efeito de placas estabilizadoras com guia balanceada bilateral, placas com guia pelo canino e placa não oclusiva. Para tal, utilizou-se uma amostra de 57 indivíduos, portadores de sinais e sintomas de deslocamento do disco com redução, com queixa de dor na ATM e sensibilidade à palpação na mesma, em pelo menos um dos lados os quais foram aleatoriamente distribuídos em três grupos: 1º grupo: composto por 19 indivíduos que receberam, como forma de tratamento, uma placa estabilizadora modificada, cujo desenho permita que durante os movimento excursivos houvesse sempre contato simultâneo de parte dos dentes em todos os segmentos da placa. 2º grupo: composto por 20 indivíduos que receberam como forma de tratamento uma placa estabilizadora convencional com guia pelo canino que estabelecia desoclusão de todos os outros dentes nos movimentos excursivos. 3º grupo: composto por 18 indivíduos que receberam uma placa não oclusiva cujo desenho não interferia com a oclusão. Toda a amostra foi acompanhada durante 6 meses, sendo avaliada através da escala de análise visual (EAV); palpação da ATM, dos músculos elevadores da mandíbula, análise dos movimentos da mandíbula e ruído articular. Uma avaliação do relato do paciente em relação ao ruído articular, alteração da oclusão e conforto também foi feita. Os resultados demonstraram que o tipo de guia não influenciou o comportamento de redução da dor, porém ambas as placas oclusais foram superiores à não-oclusiva em relação à escala de dor. E que, estatisticamente, apesar da obtenção de resultados semelhantes com relação aos movimentos de abertura, lateralidade esquerda, protrusivo, dor articular à palpação e na dor à palpação da maioria dos músculos analisados, nesse experimento, as placas com guia balanceada (grupo I) e as com guia pelo canino tiveram melhores resultados clínicos, nesses itens analisados. Com relação ao relato dos indivíduos para o conforto com a placa e ruído articular, houve uma melhor associação para o grupo I e II. Baseados no acima exposto, conclui-se que não há diferença entre a guia balanceada e a guia pelo canino no tratamento de indivíduos com deslocamento do disco com redução. / The aim of this study was to evaluate the effect of balanced splints with bilateral balanced guidance, canine guidance and nonoccluding splints. For that purpose, a study sample was employed comprising 57 individuals presenting with signs and symptoms of disc displacement with reduction and complaint of TMJ pain and tenderness to palpation of the TMJ at least at one side, who were randomly assigned to three groups: 1st group: 19 individuals submitted to therapy with a modified splint, the design of which allowed simultaneous contact of part of the teeth on all parts of the splint during excursive movements. 2nd group: 20 individuals submitted to therapy with a splint with canine guidance, which established disocclusion of all other teeth during excursive movements. 3rd group (control group): 18 individuals who received a nonoccluding splint that did not interfere with the occlusion. The entire sample was followed for 6 months and submitted to evaluation by means of the visual analogue scale (VAS), palpation of the TMJ and jaw elevator muscles and analysis of the mandibular movements and joint sounds. An evaluation concerning the patient’s report regarding the joint sounds, occlusal changes and comfort was also performed. The results demonstrated that the type of guidance did not influence the behavior as to pain reduction, yet both occlusion splints were better than the nonoccluding splint as to the pain scale. Besides, despite of the achievement of similar outcomes in relation to opening, left lateral movement, protrusive movement, TMJ pain to palpation and also pain to palpation of most muscles analyzed, there were statistically better outcomes for the splints with balanced guidance (group I) and the splints with canine guidance. Concerning the subject’s reports for comfort with the splint and joint sound, there was a better association for groups I and II. On this basis, it was concluded that there is no difference between the balanced guidance and the canine guidance for the treatment of individuals with disc displacement with reduction.
19

Analise eletromiografica da fadiga nos musculos temporal anterior e masseter de pacientes com habito de bruxismo submetidos a terapia com placas estabilizadoras do tipo Michigan

Ferreira, Juvenil Alves Neves Diniz 20 November 2002 (has links)
Orientadores : Mauro Antonio de Arruda Nobilo, Fausto Berzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:48:18Z (GMT). No. of bitstreams: 1 Ferreira_JuvenilAlvesNevesDiniz_D.pdf: 30004201 bytes, checksum: 087a9e5e0054dd19563db2fb013c4dad (MD5) Previous issue date: 2002 / Resumo: O propósito deste estudo foi avaliar bilateralmente, por meio de eletromiografia de superfície, o fenômeno da fadiga nos Mm. masseter e porção anterior do temporal em pacientes com hábito de bruxismo, antes e durante a terapia de uso das placas estabilizadoras do tipo Michigan. Foram avaliados dois grupos de voluntários: grupo 1 (grupo bruxista), composto de 16 pacientes bruxistas, sendo que 6 eram do sexo masculino e 10 do sexo feminino, com idade média de 35,68 anos (D.P.= 10,20) e grupo 2 (grupo-controle), composto de 16 voluntários assintomáticos sendo 9 do sexo masculino e 7 do sexo feminino, com idade média de 29,25 anos (D.P.= 5,27). Os voluntários do Grupo 1 fizeram uso de placas do tipo Michigan, o que não ocorreu para o Grupo 2. Entretanto, todos foram submetidos a contrações isométricas (ISO) com contração voluntária máxima de 5 segundos de duração. Após as contrações isométricas foi aplicada a escala visual analógica (EVA) para a avaliação da dor. O exame eletromiográfico foi realizado em todos os voluntários por meio de um sistema de aquisição de sinais, com eletrodos diferenciais ativos de prata pura de superfície, no interior da gaiola eletrostática de Faraday, durante os diferentes tempos (TO, T1, T2, T3 e T4). Para a análise dos dados utilizou-se o teste t para dados pareados (ao comparar a freqüência e a amplitude nos diferentes músculos além da EVA) e o teste t para duas amostras independentes (ao comparar a freqüência e a amplitude entre os grupos 1 e 2 no movimento ISO). Os resultados mostraram que, ao se comparar os Grupos 1 e 2, constatou-se fadiga localizada nos Mm. masseter e porção anterior do temporal no tempo TO. A partir dos resultados, concluiu-se que a placa do tipo Michigan foi efetiva na redução do fenômeno da fadiga muscular localizada nos voluntários com hábito de bruxismo, pois promoveu aumento na freqüência mediana, redução na amplitude do sinal eletromiográfico e redução da sensação dolorosa após a prática de exercícios de isometria / Abstract: The aim of this study was to evaluate, by surface electromyography, the fatigue of anterior part of temporal is and masseter muscles bilaterally in bruxers, before and during the use of Michigan occlusal splints. Two groups were evaluated: group 1 (patients with bruxism) with 16 patients, being 6 men and 10 women with a mean age of 35.68 years (SD = 10.20) and group 2 (control group) with 16 healthy subjects, being 9 men and 7 women, with a mean age of 29.25 years (SD = 5.27). The subjects from group 1 used Michigan occlusal splints, with were not used by subjects of group 2. However, ali the subjects were submitted to isometric contractions (ISO) with maximum voluntary contraction (MVC) of 5 seconds. After the isometric contractions, a visual analogue scale (V AS) was used to evaluate the pain. The electromyography exam was made in all the subjects by a sign acquisition system, with differential silver active surface electrodes that were kept inside Faraday electrostatic cages, in different periods of time (TO, T1, T2, T3 and T4). The t test was used to analyze the paired data (when comparing frequency and amplitude in the examined muscles and VAS) and the t test for independent samples was used to compare the frequency and amplitude in groups 1 and 2 during ISO movements). The comparison of the results of groups 1 and 2 showed a localized fatigue in masseter and anterior part of temporal is muscles during period of time TO. It was concluded that Michigan occlusal splint was effective in reducing the muscular fatigue phenomenon in bruxers, inducing an increase in the median frequency, decreasing the amplitude of the electromiographic sign and also relieving the pain after isometric contractions / Doutorado / Protese Dental / Doutor em Clínica Odontológica
20

Efeito do triclosan e associações na atividade de enzimas tipo tripsina na placa dental e na formação de compostos sulfurados volateis durante a gengivite experimental : estudo comparativo em humanos

Nogueira Filho, Getulio da Rocha 07 February 1999 (has links)
Orientadores: Sergio de Toledo, Jaime A. Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T05:44:26Z (GMT). No. of bitstreams: 1 NogueiraFilho_GetuliodaRocha_D.pdf: 5451496 bytes, checksum: ac5b6bc096e984985648f3e85b41957c (MD5) Previous issue date: 1999 / Resumo: O objetivo deste estudo foi avaliar o efeito de dentifrícios contendo tri dosan-copo límero (E), tri closan- zi nco (D), tri closan-copolímero- zi nco pirofosfato (C), triclosan-pirofosfato (B) quando comparados a um dentifrício placebo (A), na atividade de enzimas tipo tripsina (BAPNA) presente na placa dental e na formação de compostos sulfurados voláteis (CSV) com o uso de um monitor de sulfetos portátil (HALIMETER, Interscan-USA), através do modelo da gengivite experimental. Durante a fase clínica, foi realizado um estudo cruzado, duplo cego, de cinco períodos, onde a escovação dental foi suprimida por 21 dias, no quarto quadrante da boca de 19 voluntários. Em cada período, os voluntários aplicaram um dos dentifrícios na região teste, três vezes ao dia, com o auxílio de uma matriz, isolando esta da escovação, a qual foi realizada no restante da boca. Intervalos de 30 dias aconteceram entre os períodos. Para a fase laboratorial, foram coletados a placa dental e o hálito bucal dos voluntários quando estes completaram os 21 dias de cada período. Os resultados estatístiços (p=0,05) dos dados obtidos com o teste BAPNA (nmol do produto/mg de placa x min), para cada tratamento, foram os seguintes: A- 10,98a ::t 0,61; B- 11,35a ::t 1,75; C- 2,82b::t 0,43; D- 9,41a::t 1,95; E- 6,03c::t 1,17. Para a formação dos CSV (ppb): A- 81,840 ::t 4,22; B- 48,79b ::t 1,98; C- 40,21c ::t 2,67; D- 71,16d ::t 2,98; E- 44,53bc ::t 1,94 (médias seguidas de letras diferentes, estatisticamente, diferem entre si). Concluiu-se que os dentifrícios contendo as formulações triclosan-copolímero-zinco-pirofosfato e triclosan-copolímero, apresentaram os melhores resultados na redução da atividade tipo tripsina e da formação de CSV durante a gengivite experimental / Abstract: The objective of this study was to compare the effectO of dentifrices containing triclosan-copolymer (E), triclosan-zinc (D), triclosan-copolymer-zinc pyrophosphate (C), triclosan-pyrophosphate (D), with that of a placebo dentifrice without triclosan (A), on the trypsin activity (BAPNA) in dental plaque and on volatile sulphide compounds (VSC) formation by a portable sulphide monitor (HALIMETER, Interscan-USA). A double blind, cross over, experimental gingivitis study was conducted on 19 dental students during a 21 day period without toothbrushing, by a partial mouth experimental mode!. Subjects were randomly assigned to one of five dentifrices using groups. Undiluted test or placebo dentifrices were applied to the experimental teeth via toothshield. Thirty-day-wash-out i ntervals happened among the experimental periods. The data from baseline were subjected to statistical analysis (p=0,05), according to the "Cross Over" designo The results for trypsin activity (nmolproduct/mgxmin) showed that at the day 21: A- 10,98a:t 0,61; B11,35a:t 1,75; C- 2,82b:t 0,43; D- 9,41a:t 1,95; E- 6,03c:t 1,17. For VSC (ppb) formation: A- 81,84a :t 4,22; B- 48,79b :t 1,98; C- 40,21c :t 2,67; D- 71-,16d :t 2,98; E- 44,53bc :t 1,94 (means followed by different letters differs nstatistically). It was concluded that the dentifrices containing triclosancopolymer-zinc-pyrophosphate and triclosan-copolymer presented the best results for VSC and trypsin activity reduction during experimentaI9ingivi~ / Doutorado / Periodontia / Doutor em Clínica Odontológica

Page generated in 0.6158 seconds