• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Planejamento e otimização de um método quimiluminescente para determinação de vitamina B12 usando um sistema fluxo-batelada / Design and Optimization of Chemiluminescent Method for Determination of Vitamin B12 in Drugs by Using a Flow-Batch System

Moreira, Pablo Nogueira Teles 25 July 2008 (has links)
Made available in DSpace on 2015-05-14T13:21:37Z (GMT). No. of bitstreams: 1 parte1.pdf: 2426440 bytes, checksum: ed3c18b465357e2c561cffbd380b983f (MD5) Previous issue date: 2008-07-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The chemiluminescence (CL) of luminol-cobalt(II) reaction has been used in analytical systems for capillary electrophoresis, chromatography, -TAS (microTotal Analysis System), etc. Even with the diversity of applications, the steps of this reaction have not been completely elucidated and have been still a subject of research and controversy. Many works reported only to the isolated studies of the influence of each variable in the luminol-cobalt(II) reaction and, as such studies do not consider the interactions among variables, they do not exploit the total performance of this reaction in order to increase the chemiluminescent intensity (ICL). In this context, the use of an experimental design and a ChemiLumimetric Flow-Batch System (CLFBS) is proposed in this work in order to study and to optimize this reaction, aiming at to develop an automatic method to determine vitamin B12 (VB12) in drugs. For optimization purpose, a 24 factorial design was carried out fixing the cobalt concentration at 3.0 g L-1 and varying the concentration of luminol, hydrogen peroxide, sodium hydroxide and the order of mixture of these reagents. Sixteen assays were performed in five replicates, generating a total of eighty experiments. The analysis using normal plot of the experimental design revealed that the luminol concentration and the order of mixture of the reagents are variables more important than the NaOH or H2O2 concentrations to luminol-cobalt(II) reaction. These two parameters were responsible to enhance the chemiluminescent signal in about 80%. Another study was carried out in order to evaluate the CLFBS performance by using the optimized variables which were suggested by the factorial design study. Calibration curves were built by using standard solution of Co(II) and VB12 and the analytical parameters for Co(II) curve were: ΔICL = -21.39 +1771.37[Co2+] (r2 = 0.9996), LD and LQ = 12.0 ng L-1, RSD = 1.8% (n = 5), analytical sensitivity = 1947.29 W/g L-1; and VB12 curve were: ΔICL = -186.71 + 12.90 [VB12] (r2 = 0.9999), LD = 14.53 mg L-1 and LQ = 14.70 mg L-1, RSD = 2.1% (n = 4) and analytical sensitivity = 10.76 W/μg L-1. The results of the vitamin B12 analysis in drug samples employing the luminol-cobalt(II) reaction and CLFBS were enough satisfactory. Relative errors smaller than 4% were obtained by using curve calibration or standard addition method. The recovery studies yield very good values, which were of 97 to 103%. In addition, a good agreement was obtained when a drug sample was analyzed by the proposed and the reference (HPLC) method. Thus, the automatic chemilumimetric method, which was here developed and optimized, can be considered a promising alternative to quality control of vitamin B12 in drugs. / A quimiluminescência (QL) da reação luminol-cobalto(II) vem sendo empregada em sistemas analíticos de eletroforese capilar, cromatografia, -TAS (microTotal Analysis System), etc. Mesmo com a diversidade de aplicações, essa reação possui etapas pouco elucidadas que continuam sendo alvo de pesquisas e polêmicas. Muitos trabalhos relatam apenas estudos isolados da influência de cada variável na reação luminol-cobalto(II) e, por não considerar as interações entre as variáveis, estes estudos não exploram ao máximo a performance analítica desta reação. Neste contexto, foi proposto neste trabalho o uso de um planejamento experimental e de um Sistema Quimilumimétrico Fluxo-Batelada (SQLFB) para o estudo e a otimização desta reação com vista a desenvolver um método automático para a determinação de vitamina B12 (VB12) em medicamentos. Na otimização, foi utilizado um planejamento fatorial 24 em que foi mantido constante a concentração de cobalto(II) em 3,0 g L-1 enquanto variou-se as concentrações de luminol, peróxido de hidrogênio, hidróxido de sódio e a ordem de mistura destes constituintes. Foram efetuados dezesseis ensaios em quintuplicata, perfazendo um total de 80 experimentos realizados. A análise usando o gráfico normal do planejamento experimental revelou que a concentração de luminol ([Lu]) e a ordem da mistura (OM) dos reagentes são variáveis mais importante do que a concentração de NaOH e H2O2 para a reação luminol-cobalto(II). Ambas variáveis [Lu] e OM foram responsáveis por aumentar o sinal quimiluminescente em cerca de 80%. Um outro estudo foi realizado para avaliar a performance do SQLFB, empregando as variáveis otimizadas que foram sugeridas pelo estudo do planejamento fatorial. Curvas de calibração foram construídas utilizando soluções padrão de Co(II) e de VB12 e os parâmetros analíticos para a curva Co(II) foram: ΔIQL=-21,39+1771,37[Co2+](r2 = 0,9996), LD=1,54 ng L-1 e LQ=5,13 ng L-1, DPR=1,8% (n=5) e sensibilidade analítica=1947,29 Watts/μg L-1; e para a curva VB12 foram: ΔIQL= -186,71 + 12,90[VB12] (r2 = 0,9999), LD=0,89 μg L-1 e LQ = 2,98 μg L-1, DPR=2,1% (n=4) e sensibilidade analítica=10,76 Watts/μg L-1. Os resultados obtidos nas análises de vitamina B12 em medicamentos empregando a reação luminol-cobalto(II) e o SQLFB foram bastante satisfatórios. Erros relativos menores do que 4% foram obtidos empregando as técnicas de curva de calibração e de adição de padrão. Em estudos de recuperação, os valores foram também muito bons, ficando entre 97 e 103%. Além disso, uma boa concordância entre os resultados foi obtida quando uma amostra foi analisada empregando o método aqui proposto e o método de referência (HPLC). Portanto, o método quimilumimétrico automático aqui desenvolvido e otimizado pode ser considerado uma alternativa promissora para o controle de qualidade de vitamina B12 em medicamentos.

Page generated in 0.153 seconds