• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Preparação e caracterização de fases estacionarias para CLAE de poli(metilfenilsiloxano) sobre silica sorvida e imobilizada por radiação microonda / Preparation and characterization of sorbed and microwave immobilized HPLC stationary phases of poly (metilfenilsiloxane) on silica

Fioravanti, Livia Maria Andrekowisk 28 November 2007 (has links)
Orientador: Isabel Cristina Sales Fontes Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-10T09:05:57Z (GMT). No. of bitstreams: 1 Fioravanti_LiviaMariaAndrekowisk_M.pdf: 984234 bytes, checksum: 0c41c940c79a927bb0f835b15b3739d0 (MD5) Previous issue date: 2007 / Resumo: Em cromatografia líquida de alta eficiência (CLAE), a coluna é um dos principais componentes do sistema cromatográfico, pois é nela que ocorre a separação. Dessa forma, a busca por fases estacionárias (FE) capazes de realizar separações com alta eficiência e bom desempenho tem sido uma constante em muitos laboratórios de pesquisa. Polissiloxanos substituídos com grupos fenil têm sido intensamente utilizados em cromatografia gasosa, mas a sua aplicação em CLAE tem despertado pouca atenção. Este trabalho apresenta a preparação de FE para CLAE a partir da imobilização de poli(metilfenilsiloxano), por radiação microonda, sobre suporte de sílica. As FE foram caracterizadas por testes físico-químicos e cromatográficos. Escolheu-se a radiação microonda por se mostrar promissora e pouco estudada para imobilização de FE. Para a escolha das melhores condições de radiação foi aplicado um planejamento fatorial, sendo que a potência e o tempo de radiação que resultaram em fases com melhor desempenho cromatográfico foram de 720 W por 70 minutos. Nestas condições, as FE apresentaram alta eficiência (78.000 pratos m), picos simétricos (com fator de assimetria entre 0,9 e 1,2) para compostos apolares e básicos e boa resolução entre os compostos analisados. Os parâmetros cromatográficos indicaram que a radiação microonda melhorou o desempenho das FE, proporcionou um aumento da sua estabilidade frente à fase móvel alcalina e forneceu um bom recobrimento da superfície da sílica pelo polímero. A FE preparada mostrou-se promissora na separação de compostos aromáticos neutros e básicos, como fármacos contendo grupos nitrogenados e agrotóxicos / Abstract: In high performance liquid chromatography (HPLC), the column is one of the most important components of the chromatographic system, because it is in the column that the separation occurs. In this way, the search for stationary phases (SP) able to achieve separations with high efficiency has been a constant in many research laboratories. Phenyl substituted polysiloxanes have been used extensively in gas chromatography, but their application in HPLC has received little attention. This work presents the development of stationary phases for use in HPLC by immobilization of poly(methylphenylsiloxane) by microwave radiation on a silica support. The SP were characterized by physiochemical and chromatographic tests. Microwave radiation was chosen because it appears to be promising and has been little studied for SP immobilization. The best conditions of radiation were chosen using an experimental design, with the microwave power and the radiation time that provided phases with the best chromatographic performance, these being 720 W and 70 minutes. In these conditions, the SP showed high efficiency (78000 plates m), symmetrical peaks (asymmetry factor between 0.9 and 1.2) for nonpolar and basic compounds and good separation for the compounds analyzed. The chromatographic parameters show that microwave radiation improved the performance of the SP and provided an increase in stability in alkaline mobile phases. Besides, it provided a good polymer cover on silica surface, being a promising SP for the separation of neutral and basic aromatic compounds, such as pharmaceuticals with nitrogen groups and agrochemicals / Mestrado / Quimica Analitica / Mestre em Química
2

Desenvolvimento de fases estacionárias C18 termicamente imobilizadas sobre sílica e sílicas metalizadas e suas caracterizações químicas, físicas e cromatográficas utilizando a cromatografia líquida de alta eficiência (CLAE) e a cromatografia com fluido supercrítico (CFS) / Development of C18 stationary phases immobilized onto silica and metalized silicas and their chemical, physical and chromatographic characterizations using high performance liquid chromatography (HPLC) and supercritical fluid chromatography (SFC)

Silva, Carla Grazieli Azevedo da, 1978- 22 August 2018 (has links)
Orientador: Carol Hollingworth Collins / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T07:24:16Z (GMT). No. of bitstreams: 1 Silva_CarlaGrazieliAzevedoda_D.pdf: 4489958 bytes, checksum: f1c0299f6db7beed410c437dcdfc5886 (MD5) Previous issue date: 2013 / Resumo: Este trabalho apresenta o desenvolvimento de fases estacionárias (FE) para cromatografia líquida de alta eficiência em fase reversa (CLAE-FR) e cromatografia com fluido supercrítico (CFS) a partir da imobilização térmica de poli(metiloctadecilsiloxano) (PMODS) sobre suportes de sílicas metalizadas com zircônio e titânio. O processo de imobilização térmica do PMODS foi otimizado aplicando-se planejamento composto central. O polímero, os suportes e as fases estacionárias foram caracterizados por testes físicoquímicos e cromatográficos. As fases estacionárias Si(PMODS), Si-Zr(PMODS) e Si-Ti(PMODS) apresentaram os melhores resultados quando foi aplicada a temperatura de 120 °C por 16 horas. As melhores FE foram submetidas ao processo de capeamento. Estas FE mostraram eficiências entre 82.000 e 90.000 pratos m e boas separações com picos simétricos para compostos apolares e picos com simetria adequada, segundo parâmetros estabelecidos pela Farmacopéia Americana (United States Pharmacopeia), para compostos polares, avaliados pelos testes de Engelhardt, Tanaka, Neue, SRM 870 e pelo modelo dos parâmetros de solvatação utilizando CFS. A presença do óxido metálico no suporte resultou em FE com maior estabilidade química em condições drásticas de fase móvel (pH 1,7 e pH 10 a 50 °C), quando comparada com fases similares baseadas em sílica nua. A reação de capeamento melhorou a estabilidade química das FE e diminuiu o número de silanóis residuais. As FE Si-Zr(PMODS), Si-Ti(PMODS), Si-Zr(PMODS)ec e Si- Ti(PMODS)ec apresentam potencialidade na separação de fármacos psicoativos, filtros ultravioleta (UV), xantinas e hidrocarbonetos policíclicos aromáticos (HPA), utilizando CLAE e CFS. / Abstract: This work presents the development of stationary phases (SP) for high performance liquid chromatography in the reversed phase (RP-HPLC) and for supercritical fluid chromatography (SFC) prepared by the sorption and thermal immobilization of poly(methyloctadecylsiloxane) (PMODS) onto silica and metalized silica supports modified with zirconium and titanium. The immobilization process was optimized using central composite design for determination of the best conditions of time and temperature. The polymer, supports and stationary phases were characterized with physico-chemical and chromatographic tests. The stationary phases Si(PMODS), Si-Zr(PMODS) and Si-Ti(PMODS) presented the best results when a temperature of 120 °C for 16 hours was applied. The best SP were submitted to endcapping processes. These SP showed efficiencies between 82,000 and 90,000 plates m and good separations with symmetric peaks for apolar and polar compounds evaluated by the Engelhardt, Tanaka, Neue and SRM 870 tests and the solvation parameter model using supercritical fluid chromatography (SFC). The presence of metallic oxide on the supports resulted in stationary phases with better chemical stability under drastic conditions of mobile phase (pH 1.7 and pH 10 at 50 °C), when compared to similar stationary phases based on bare silica. The endcapping reaction improved the chemical stability. The SP Si-Zr(PMODS), Si- Ti(PMODS), Si-Zr(PMODS)ec e Si-Ti(PMODS)ec presented potentialities for the separation different pharmaceutical compounds used as psychotropic drugs, ultraviolet (UV) filters, xanthines, and polycyclic aromatic hydrocarbons (PAH), using separations in HPLC and SFC. / Doutorado / Quimica Analitica / Doutor em Ciências

Page generated in 0.0422 seconds