• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Propriedades cromatográficas e estabilidade de fases estacionárias preparadas pela imobilização térmica de polissiloxanos sobre a sílica / Chromatographic and stability evaluations of stationary phases prepared by thermal immobilization of polysiloxanes onto silica surfaces

Souza, Endler Marcel Borges de 04 January 2011 (has links)
Orientador: Carol Hollingworth Collins / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-18T09:08:43Z (GMT). No. of bitstreams: 1 Souza_EndlerMarcelBorgesde_D.pdf: 24501631 bytes, checksum: 4fd1866c1e1f40857962b738d98e6eb5 (MD5) Previous issue date: 2011 / Resumo: As propriedades cromatográficas e a estabilidade de fases estacionárias preparadas pela imobilização térmica do poli(metiloctilsiloxano) ou do poli(metiltetradecilsiloxano) sobre a sílica foram avaliadas. Para isso, fora empregados os testes de Engelhardt, Tanaka e SRM 870. O estudo dos mecanismos envolvidos na retenção de solutos básicos nestas fases estacionárias foi feita com um teste desenvolvido em nosso laboratório, que consiste em avaliar os fatores de retenção e a assimetria de solutos hidrofóbicas e hidrofílicas em fases móveis com diferentes valores de pH, preparadas com diferentes tipos e concentrações de tampão. A avaliação das fases estacionárias com os testes SRM 870 e de Tanaka mostram uma alta contribuição dos fenômenos de troca iônica para retenção dos solutos básicos e a comparação dos valores obtidos com o teste de Tanaka, segundo o modelo de Euerby, mostrou que estas fases estacionárias apresentam propriedades cromatográficas distintas da maioria das fases comerciais, embora alguma similaridade tenha sido observada com as fases estacionárias que também apresentam altas contribuições de fenômenos de troca iônica na retenção de solutos básicos. O novo teste desenvolvido mostrou que a retenção de solutos básicos acontece devido a interações sinérgicas dos silanóis residuais com os polisiloxanos imobilizados na forma de gotas sobre a sílica. Devido a estas interações, o pH da fase móvel, o tipo e a concentração de tampão afetam intensamente os fatores de retenção e a assimetria de solutos básicos. Algumas das fases estacionárias apresentaram boa seletividade e picos simétricos para solutos básicos em fases móveis neutras, onde os solutos estam protonados e os silanóis residuais estão desprotonados. Os testes de estabilidade demonstraram que algumas das fases estacionárias são altamente estáveis em fases móveis neutras em temperatura ambiente e em fases móveis ácidas, mesmo a altas temperaturas. No entanto, estas se mostraram instáveis em fases móveis alcalinas mesmo em temperatura ambiente, conforme esperado para fases estacionárias preparadas pela imobilização de polissiloxanos sobre a sílica / Abstract: This work has evaluated the chromatographic properties and the stability of stationary phases prepared by with poly(methyloctylsiloxane) or poly(methyltetradecylsiloxane) thermally immobilized onto a silica surface. The stationary phases were chromatographically evaluated using the Engelhardt, SRM 870 and Tanaka tests. The retention mechanisms involved during the separation of basic solutes with these stationary phases were evaluated using a test developed in our laboratory that evaluates the effect of the mobile phases with different pH, and type and concentration of buffer on the retention factors and asymmetry of several basic solutes (with hydrophobic or hydrophilic characteristics). Evaluations with the SRM 870 and Tanaka tests showed that there is a high contribution of ionexchange interactions at neutral pH. Classifications using the Euerby¿s procedure indicate that the stationary phases developed in this work are different from most commercial ones, although some similarity was found with the phases that have high ion-exchange interactions. Also, the retention of basic solutes occurs due to synergetic interactions between the free silanols with the immobilized polysiloxanes, which are in the form of plugs on the silica surface. Due to these interactions the pH of the mobile phase, and the type and concentration of buffer have a strong effect on the retention factors and asymmetry factors of basic solutes. The stationary phases present good selectivity at near neutral pH, where both the basic solutes and free silanols are protonated, suggesting the use of intermediate pH for basic solute analyses. Stability tests show that the stationary phases have high stability in neutral mobile phases at room temperature and also in acidic mobile phases, even at high temperatures. However, these phases have low stability in alkaline mobile phases, even at room temperature, which was expected for polysiloxanes immobilized onto silica / Doutorado / Quimica Analitica / Doutor em Ciências
2

Preparo, caracterização e aplicação de fases estacionárias de poli(dimetilsiloxano-co-metilfenilsiloxano) sorvidas e imobilizadas sobre sílica e sílica zirconizada / Preparation, characterization and application of stationary phases based on poly(dimethylsiloxane-co-methylphenylsiloxane), sorbed and immobilized onto silica and zirconized silica

Segato, Milena Pinotti 18 August 2018 (has links)
Orientador: Isabel Cristina Sales Fontes Jardim / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-18T09:12:26Z (GMT). No. of bitstreams: 1 Segato_MilenaPinotti_D.pdf: 2442383 bytes, checksum: e69a88b2ce9ec4c5ba2780755d0a6c2f (MD5) Previous issue date: 2011 / Resumo: Este trabalho descreve o desenvolvimento de novas fases estacionárias (FE) sorvidas e imobilizadas para cromatografia líquida de alta eficiência em fase reversa (CLAE-FR), utilizando-se suporte de sílica não modificada e metalizada com zircônia, recobertos com o polímero poli(dimetilsiloxano-co-metilfenilsiloxano) (PDMFS). O processo de imobilização do polímero foi feito por tratamento térmico e as condições que forneceram FE com o melhor desempenho cromatográfico foram 140 ºC e 6 h. As FE preparadas sob estas condições apresentaram porcentagens de carbono entre 10 e 11 % e espessura de camada entre 0,6 e 0,7 nm. Foi feito o capeamento das FE buscando-se um melhor recobrimento dos sítios ativos do suporte e, após este procedimento, houve um aumento de cerca de 2 % na porcentagem de carbono e redução do número de silanóis livres e vicinais nos suportes cromatográficos. A caracterização físico-química das FE sugere que o PDMFS está fisicamente adsorvido e quimicamente ligado aos suportes, sendo que as interações com o suporte metalizado são mais intensas. As FE foram avaliadas cromatograficamente por meio da separação de algumas misturas teste e seus desempenhos foram similares aos de colunas comerciais tradicionais, com eficiências superiores a 70000 pratos m para o acenafteno, nas FE não capeadas, e acima de 56000 pratos m nas FE capeadas. As características cromatográficas das FE preparadas foram similares no que diz respeito às seletividades hidrofóbica, estérica e aromática. As FE capeadas apresentaram maior hidrofobicidade e menor capacidade de formação de ligações de hidrogênio que as FE não capeadas. A zirconização aumentou a acidez dos sítios ativos e a capacidade de troca iônica das sílicas zirconizadas. Por outro lado, a combinação da zirconização do suporte com o capeamento é uma estratégia importante para a obtenção de FE com estabilidade elevada. As FE desenvolvidas neste trabalho apresentam potencial para serem aplicadas na separação de compostos aromáticos de diferentes polaridades, agrotóxicos e fármacos contendo grupos básicos / Abstract: This work describes the development of new stationary phases (SP) based on poly(dimethylsiloxane-co-methylphenylsiloxane) sorbed and immobilized onto silica and zirconized silica for reversed phase high performance liquid chromatography. The polymer was immobilized by thermal treatment at 140 °C during 6 h, which were the conditions that produced SP with the best chromatographic performance. The SP prepared using these conditions presented carbon loadings between 10 and 11 % and polymeric thicknesses between 0.6 and 0.7 nm. The SP were end-capped aiming at a better coverage of the active sites of the support. This procedure increased the carbon loadings by about 2 % and reduced the number of free and vicinal silanols on the chromatographic supports. Physico-chemical characterization of the SP suggests that PDMFS is physically absorbed and chemically bonded to the supports and that the interactions with the metalized support are stronger. The SP were chromatographically evaluated by the separation of some test mixtures and the performances were similar to those of traditional commercial columns, with column efficiencies higher than 70000 plates m for acenaphthene on the SP without endcapping, and above 56000 plates m with the end-capped SP. The chromatographic characteristics of the SP were similar with regard to hydrophobic, spatial and aromatic selectivities. The end-capped SP presented higher hydrophobicity and lower hydrogen bonding capacity than the not end-capped SP. The metallization procedure increased the acidity of active sites and the ion exchange capacity of zirconized silica. However, the combination of zirconization of the support and the end-capping procedure is an important strategy to obtain SP with high stability. The SP presented potential for the separations of aromatic compounds with different polarities, of pesticides and of pharmaceuticals having basic groups / Doutorado / Quimica Analitica / Doutor em Ciências
3

Preparação e caracterização de fase estacionária reversa fenil-propil-metil-siloxano, imobilizada por micro-ondas, para cromatografia líquida de alta eficiência / Preparation and characterization of microwave-immobilized phenyl-propyl-methyl-siloxane stationary phase for reversed-phase high-performance liquid chromatography

Begnini, Fernanda Ribeiro 08 January 2011 (has links)
Orientador: Isabel Cristina Sales Fontes Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-19T02:08:02Z (GMT). No. of bitstreams: 1 Begnini_FernandaRibeiro_M.pdf: 1951363 bytes, checksum: fe0989f49b67e9b16db7e81f2c1544f5 (MD5) Previous issue date: 2011 / Resumo: Novas fases estacionárias (FE) para Cromatografia Líquida de Alta Eficiência em fase reversa (CLAE-FR) foram preparadas a partir da sorção e imobilização por micro-ondas do copolímero poli(2- fenilpropil)metilsiloxano (PFPMS) sobre suporte de sílica Kromasil (tipo B, esférica, 5 mm). A FE preparada com carga do copolímero de 50%, imobilizada a 540 W por 80 minutos e extraída com clorofórmio (3 horas) e metanol (2 horas) após 8 dias de imobilização, apresentou desempenho cromatográfico satisfatório, com eficiências acima de 60000 pratos/m e parâmetros cromatográficos na faixa aceita pela literatura. Através da caracterização físico-química da FE preparada, pelas técnicas de RMN Si e C, e espectroscopia de absorção no infravermelho, entre outras, foi possível sugerir que o PFPMS encontra-se fisicamente sorvido e quimicamente ligado à sílica. A caracterização cromatográfica mostrou que a FE possui seletividade hidrofóbica, seletividade estérica, pouca interação com analitos polares e grupos silanóis residuais, sendo características apropriadas para uma FR. A FE preparada apresenta grande potencial na separação de agrotóxicos, fármacos e hidrocarbonetos policíclicos aromáticos, além de possuir estabilidade em meio ácido / Abstract: A new stationary phase for reversed-phase high-performance liquid chromatography (RP-HPLC) was prepared by sorption and microwave immobilization of the copolymer poly(2- phenylpropyl)methylsiloxane (PPPMS) onto a silica support (Kromasil®, type B, 5 mm). The stationary phase prepared with copolymeric content of 50%, immobilized at 540 W for 80 min and extracted with chloroform (3 hours) and methanol (2 hours) eight days after immobilization, showed satisfactory chromatographic performance, with efficiency above 60000 plates/m and symmetrical peaks. The physical¿chemical characterization of the new microwave immobilized stationary phase using solid-state NMR spectroscopy and infrared spectroscopy suggested that the copolymer is physically sorbed and chemically bonded onto the silica support. The chromatographic characterization showed that the stationary phase has hydrophobic selectivity, steric selectivity, low interaction with polar analytes and residual silanols, suggesting that the stationary phase prepared is promising to be used in RP-HPLC. The microwave immobilized stationary phase presented chemical stability and potential applicability to separation of pesticides, pharmaceutical drugs and polycyclic aromatic hydrocarbons / Mestrado / Quimica Analitica / Mestre em Química
4

Desenvolvimento de fases estacionarias para cromatografia liquida de alta eficiencia em fase reversa a partir da adsorção e imobilização do poli(metiltetradecilsiloxano) sobre silica metalizada / Development of stationary phases for reservesed-phase hight-performance liquid chromatography by adsortion and immobilization of poly(metyltetradecysiloxane) onto metalized silica supports

Faria, Anizio Marcio de 12 January 2006 (has links)
Orientador: Carol Hollingworth Collins / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-07T20:37:42Z (GMT). No. of bitstreams: 1 Faria_AnizioMarciode_D.pdf: 2871302 bytes, checksum: 58d9a466b2a4724df83a92414de3d9a9 (MD5) Previous issue date: 2006 / Doutorado / Quimica Analitica / Doutor em Quimica
5

Desenvolvimento de fases estacionárias C18 termicamente imobilizadas sobre sílica e sílicas metalizadas e suas caracterizações químicas, físicas e cromatográficas utilizando a cromatografia líquida de alta eficiência (CLAE) e a cromatografia com fluido supercrítico (CFS) / Development of C18 stationary phases immobilized onto silica and metalized silicas and their chemical, physical and chromatographic characterizations using high performance liquid chromatography (HPLC) and supercritical fluid chromatography (SFC)

Silva, Carla Grazieli Azevedo da, 1978- 22 August 2018 (has links)
Orientador: Carol Hollingworth Collins / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T07:24:16Z (GMT). No. of bitstreams: 1 Silva_CarlaGrazieliAzevedoda_D.pdf: 4489958 bytes, checksum: f1c0299f6db7beed410c437dcdfc5886 (MD5) Previous issue date: 2013 / Resumo: Este trabalho apresenta o desenvolvimento de fases estacionárias (FE) para cromatografia líquida de alta eficiência em fase reversa (CLAE-FR) e cromatografia com fluido supercrítico (CFS) a partir da imobilização térmica de poli(metiloctadecilsiloxano) (PMODS) sobre suportes de sílicas metalizadas com zircônio e titânio. O processo de imobilização térmica do PMODS foi otimizado aplicando-se planejamento composto central. O polímero, os suportes e as fases estacionárias foram caracterizados por testes físicoquímicos e cromatográficos. As fases estacionárias Si(PMODS), Si-Zr(PMODS) e Si-Ti(PMODS) apresentaram os melhores resultados quando foi aplicada a temperatura de 120 °C por 16 horas. As melhores FE foram submetidas ao processo de capeamento. Estas FE mostraram eficiências entre 82.000 e 90.000 pratos m e boas separações com picos simétricos para compostos apolares e picos com simetria adequada, segundo parâmetros estabelecidos pela Farmacopéia Americana (United States Pharmacopeia), para compostos polares, avaliados pelos testes de Engelhardt, Tanaka, Neue, SRM 870 e pelo modelo dos parâmetros de solvatação utilizando CFS. A presença do óxido metálico no suporte resultou em FE com maior estabilidade química em condições drásticas de fase móvel (pH 1,7 e pH 10 a 50 °C), quando comparada com fases similares baseadas em sílica nua. A reação de capeamento melhorou a estabilidade química das FE e diminuiu o número de silanóis residuais. As FE Si-Zr(PMODS), Si-Ti(PMODS), Si-Zr(PMODS)ec e Si- Ti(PMODS)ec apresentam potencialidade na separação de fármacos psicoativos, filtros ultravioleta (UV), xantinas e hidrocarbonetos policíclicos aromáticos (HPA), utilizando CLAE e CFS. / Abstract: This work presents the development of stationary phases (SP) for high performance liquid chromatography in the reversed phase (RP-HPLC) and for supercritical fluid chromatography (SFC) prepared by the sorption and thermal immobilization of poly(methyloctadecylsiloxane) (PMODS) onto silica and metalized silica supports modified with zirconium and titanium. The immobilization process was optimized using central composite design for determination of the best conditions of time and temperature. The polymer, supports and stationary phases were characterized with physico-chemical and chromatographic tests. The stationary phases Si(PMODS), Si-Zr(PMODS) and Si-Ti(PMODS) presented the best results when a temperature of 120 °C for 16 hours was applied. The best SP were submitted to endcapping processes. These SP showed efficiencies between 82,000 and 90,000 plates m and good separations with symmetric peaks for apolar and polar compounds evaluated by the Engelhardt, Tanaka, Neue and SRM 870 tests and the solvation parameter model using supercritical fluid chromatography (SFC). The presence of metallic oxide on the supports resulted in stationary phases with better chemical stability under drastic conditions of mobile phase (pH 1.7 and pH 10 at 50 °C), when compared to similar stationary phases based on bare silica. The endcapping reaction improved the chemical stability. The SP Si-Zr(PMODS), Si- Ti(PMODS), Si-Zr(PMODS)ec e Si-Ti(PMODS)ec presented potentialities for the separation different pharmaceutical compounds used as psychotropic drugs, ultraviolet (UV) filters, xanthines, and polycyclic aromatic hydrocarbons (PAH), using separations in HPLC and SFC. / Doutorado / Quimica Analitica / Doutor em Ciências

Page generated in 0.1503 seconds