• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do contra-íon usado na eletrossíntese do polipirrol em sua resposta como biossensor eletroquímico após a imobilização da polifenol oxidase / Influence of counter-ion used in the electrosynthesis of polypyrrole in your response as electrochemical biosensors after polyphenol oxidase immobilization

Barioto, Valquiria da Cruz Rodrigues 16 July 2009 (has links)
Neste trabalho, foram fabricados biossensores amperométricos a partir do uso da polifenol oxidase (PFO), obtida do abacate como fonte enzimática, imobilizada em filmes de polipirrol (PPI) e que foram eletrossintetizados em meio de três diferentes eletrólitos de suporte (NaCl e NaClO4 e NaDDS). O método de imobilização enzimática foi o da adsorção, sendo a solução de enzima adicionada à solução com o pirrol e o eletrólito durante o processo de eletropolimerização. Os filmes de PPI/PFO foram caracterizados por técnicas eletroquímicas, principalmente por voltametria cíclica. A detecção de compostos fenólicos (catecol e pirogalol) foi realizada pela técnica de cronoamperometria após se variar a concentração do analito. A morfologia dos filmes foi estudada por microscopia de força atômica (AFM), sendo observado que a presença da enzima no filme polimérico assim como o uso de diferentes eletrólitos de suporte levou a diferenças na superfície dos filmes. Além disto, verificou-se que o biossensor construído a partir do uso do NaCl, apresentava uma resposta mais eficiente, ou seja, ele foi capaz de detectar catecol e pirogalol em um menor limite de detecção. / In this study amperometric biosensors were manufactured from the use of polyphenol oxidase (PPO) obtained from avocado as a source of enzyme immobilized in polypyrrole (PPY) films that were electrosynthesized with three different support electrolytes (NaCl, NaClO4 and NaDDS). The method of enzyme immobilization was the adsorption. The PPO was added in the solution containing pyrrole and electrolyte during electropolymerization. The PPY/PPO films were characterized by electrochemical techniques mainly by cyclic voltammetry. Detection of phenolic compounds (catechol and pyrogallol) was performed by the technique of chronoamperometry after varying the concentration of the analyte. The morphology of the films was studied by the atomic force microscopy (AFM) and observed that the presence of the enzyme in the polymer film and the use of different electrolytes support led to differences in the surface of films. However it was found that the biosensor constructed from the use of NaCl showed more efficient response and it was able to detect catechol and pyrogallol in a lower limit of detection.
2

Estudos sobre a imobilização da polifenoloxidase em filmes de polipirrol/poli-3-metiltiofeno e uso destes filmes em biossensores amperométricos / Studies on the immobilization of polyphenoloxidase polypyrrole/poly-3-methylthiophene films and their use in amperometric biosensors

Sousa, Lívia Maria de Castro 07 June 2013 (has links)
Nesta dissertação, foram estudados os métodos de síntese de filmes poliméricos como matrizes hospedeiras da enzima tirosinase vislumbrando o desenvolvimento de biossensores mais seletivos e duradouros na detecção de compostos fenólicos. Os polímeros utilizados e preparados por cronoamperometria em acetonitrila foram: polipirrol (PPI), polimetiltiofeno (PMET) e copolímero PPI-PMET. Os filmes PPI-PMET apresentaram características intermediárias às dos filmes PPI e PMET, conforme se verificaram em espectros na região do infravermelho (FTIR), voltametria cíclica e microscopia de força atômica (AFM), evidenciando, assim, a formação de uma nova matriz polimérica. O processo de superoxidação do filme PPI-PMET foi estudado visando a uma imobilização mais eficiente da enzima, quando se obteve uma condição na qual a superoxidação ocorre somente nas cadeias de PPI. Biossensores amperométricos foram preparados a partir do uso da tirosinase extraída do abacate como fonte enzimática por imobilização física e realizada de maneiras diferentes em filmes não superoxidados e superoxidados. Foi feita a otimização das respostas dos filmes variando-se o pH, potencial de trabalho, concentração da enzima e tempo de imobilização da enzima para a detecção de catecol. Os resultados indicaram que a superoxidação do PPI nos filmes PPI-PMET favoreceu a imobilização da enzima, embora não fosse tão eficiente quando se comparou aos filmes com o PPI não superoxidado. Contudo, os biossensores, em geral, apresentaram grande sensibilidade ao catecol, com um limite de detecção baixo, da ordem de 0,12 µmol/L. / The synthesis methods of polymer films as host matrices of the enzyme tyrosinase were studied in this dissertation. It was expected the development of selective and everlasting biosensors for the detection of phenolic compounds. The used polymers were prepared by chronoamperometry in acetonitrile as followed: polypyrrole (PPI), polymethylthiophene (PMET) and copolymer PPI-PMET. The PPI-PMET films showed intermediate characteristics as the PPI and PMET films, as observed in the infrared spectra (FTIR), cyclic voltammetry and atomic force microscopy (AFM), thus indicating the formation of a new polymeric matrix . The process of overoxidized of PPI-PMET film was studied in order to achieve a more efficient immobilization of the enzyme, whilst it was achieved a condition in which overoxidized occurs only in the PPI chain. Amperometric biosensors were prepared from the use of tyrosinase extracted from avocado as an enzyme source by physical immobilization and performed in different ways in both overoxidized and non-overoxidized films. It was performed the optimization of the responses of the films by varying pH, operacuonial potential, enzyme concentration and time in the enzyme immobilization for the detection of catechol. The results showed that the overoxidized PPI in the films PPI-PMET favored the immobilization of the enzyme, although not as efficient when compared to the films with nom overoxidized PPI. Neverthless, the catechol biosensors showed a high sensitivity with a low detection limit in the order of 0.12 µmol/L.
3

Filmes de polipirrol como matrizes para a imobilização da polifenol oxidase e aplicação como biossensores amperométricos na análise de compostos fenólicos / Polypyrrole film as matrix for the immobilization of polyphenol oxidase and application as amperometric biosensors in the analysis of phenolic

Ferreira, Elys Raquel Andrade 14 December 2007 (has links)
Nesta dissertação, a polifenol oxidase (PFO) como extrato bruto de abacate (Persea americana) foi imobilizada em filmes de polipirrol (PPI) sintetizados eletroquimicamente utilizando o glutaraldeído (GA) como um agente de ligação entrecruzada. Os filmes PPI e PPI/PFO-GA foram caracterizados por eletroquímica, principalmente voltametria cíclica, sendo avaliadas a eletroatividade e a reversibilidade eletroquímica. A detecção de compostos fenólicos em soluções padrão foi feita por cronoamperometria, tendo um controle sobre a concentração dos compostos. O processo de transferência de massa foi monitorado com uma microbalança de cristal de quartzo eletroquímica. Os resultados indicaram uma boa reprodutibilidade das medidas na detecção dos compostos fenólicos. A estabilidade do biossensor em uma solução tampão manteve-se durante 27 dias, um resultado aceitável já que é encontrado na literatura um tempo de vida estável para sistemas semelhantes em tomo de 30 dias / In this dissertation, polyphenol oxidase (PPO) as crude extract of avocado (Persea americana) was immobilized on electrochemical1y synthesized polypyrrole (PPY) films using glutaraldehyde (GA) as a crosslinking agent. PPY and PPY/PPO-GA films were electrochemical1y characterized, mainly by cyclic voltametry, where electroactivity and electrochemical reversibility were evaluated. The detection of phenolic compounds in standard samples was made by chronoamperometry with a control over the compound concentration. The process of mass transfer was monitored with an electrochemical quartz crystal microbalance (EQCM). Our results indicated a good repeatability of the measurements for the detection of phenolic compounds. The stability of biosensor in a buffer solution has remained for 27 days, a result acceptable since it is found in the literature a time of life stable for similar systems around 30 days
4

Estudos sobre a imobilização da polifenoloxidase em filmes de polipirrol/poli-3-metiltiofeno e uso destes filmes em biossensores amperométricos / Studies on the immobilization of polyphenoloxidase polypyrrole/poly-3-methylthiophene films and their use in amperometric biosensors

Lívia Maria de Castro Sousa 07 June 2013 (has links)
Nesta dissertação, foram estudados os métodos de síntese de filmes poliméricos como matrizes hospedeiras da enzima tirosinase vislumbrando o desenvolvimento de biossensores mais seletivos e duradouros na detecção de compostos fenólicos. Os polímeros utilizados e preparados por cronoamperometria em acetonitrila foram: polipirrol (PPI), polimetiltiofeno (PMET) e copolímero PPI-PMET. Os filmes PPI-PMET apresentaram características intermediárias às dos filmes PPI e PMET, conforme se verificaram em espectros na região do infravermelho (FTIR), voltametria cíclica e microscopia de força atômica (AFM), evidenciando, assim, a formação de uma nova matriz polimérica. O processo de superoxidação do filme PPI-PMET foi estudado visando a uma imobilização mais eficiente da enzima, quando se obteve uma condição na qual a superoxidação ocorre somente nas cadeias de PPI. Biossensores amperométricos foram preparados a partir do uso da tirosinase extraída do abacate como fonte enzimática por imobilização física e realizada de maneiras diferentes em filmes não superoxidados e superoxidados. Foi feita a otimização das respostas dos filmes variando-se o pH, potencial de trabalho, concentração da enzima e tempo de imobilização da enzima para a detecção de catecol. Os resultados indicaram que a superoxidação do PPI nos filmes PPI-PMET favoreceu a imobilização da enzima, embora não fosse tão eficiente quando se comparou aos filmes com o PPI não superoxidado. Contudo, os biossensores, em geral, apresentaram grande sensibilidade ao catecol, com um limite de detecção baixo, da ordem de 0,12 µmol/L. / The synthesis methods of polymer films as host matrices of the enzyme tyrosinase were studied in this dissertation. It was expected the development of selective and everlasting biosensors for the detection of phenolic compounds. The used polymers were prepared by chronoamperometry in acetonitrile as followed: polypyrrole (PPI), polymethylthiophene (PMET) and copolymer PPI-PMET. The PPI-PMET films showed intermediate characteristics as the PPI and PMET films, as observed in the infrared spectra (FTIR), cyclic voltammetry and atomic force microscopy (AFM), thus indicating the formation of a new polymeric matrix . The process of overoxidized of PPI-PMET film was studied in order to achieve a more efficient immobilization of the enzyme, whilst it was achieved a condition in which overoxidized occurs only in the PPI chain. Amperometric biosensors were prepared from the use of tyrosinase extracted from avocado as an enzyme source by physical immobilization and performed in different ways in both overoxidized and non-overoxidized films. It was performed the optimization of the responses of the films by varying pH, operacuonial potential, enzyme concentration and time in the enzyme immobilization for the detection of catechol. The results showed that the overoxidized PPI in the films PPI-PMET favored the immobilization of the enzyme, although not as efficient when compared to the films with nom overoxidized PPI. Neverthless, the catechol biosensors showed a high sensitivity with a low detection limit in the order of 0.12 µmol/L.
5

Filmes de polipirrol como matrizes para a imobilização da polifenol oxidase e aplicação como biossensores amperométricos na análise de compostos fenólicos / Polypyrrole film as matrix for the immobilization of polyphenol oxidase and application as amperometric biosensors in the analysis of phenolic

Elys Raquel Andrade Ferreira 14 December 2007 (has links)
Nesta dissertação, a polifenol oxidase (PFO) como extrato bruto de abacate (Persea americana) foi imobilizada em filmes de polipirrol (PPI) sintetizados eletroquimicamente utilizando o glutaraldeído (GA) como um agente de ligação entrecruzada. Os filmes PPI e PPI/PFO-GA foram caracterizados por eletroquímica, principalmente voltametria cíclica, sendo avaliadas a eletroatividade e a reversibilidade eletroquímica. A detecção de compostos fenólicos em soluções padrão foi feita por cronoamperometria, tendo um controle sobre a concentração dos compostos. O processo de transferência de massa foi monitorado com uma microbalança de cristal de quartzo eletroquímica. Os resultados indicaram uma boa reprodutibilidade das medidas na detecção dos compostos fenólicos. A estabilidade do biossensor em uma solução tampão manteve-se durante 27 dias, um resultado aceitável já que é encontrado na literatura um tempo de vida estável para sistemas semelhantes em tomo de 30 dias / In this dissertation, polyphenol oxidase (PPO) as crude extract of avocado (Persea americana) was immobilized on electrochemical1y synthesized polypyrrole (PPY) films using glutaraldehyde (GA) as a crosslinking agent. PPY and PPY/PPO-GA films were electrochemical1y characterized, mainly by cyclic voltametry, where electroactivity and electrochemical reversibility were evaluated. The detection of phenolic compounds in standard samples was made by chronoamperometry with a control over the compound concentration. The process of mass transfer was monitored with an electrochemical quartz crystal microbalance (EQCM). Our results indicated a good repeatability of the measurements for the detection of phenolic compounds. The stability of biosensor in a buffer solution has remained for 27 days, a result acceptable since it is found in the literature a time of life stable for similar systems around 30 days
6

Influência do contra-íon usado na eletrossíntese do polipirrol em sua resposta como biossensor eletroquímico após a imobilização da polifenol oxidase / Influence of counter-ion used in the electrosynthesis of polypyrrole in your response as electrochemical biosensors after polyphenol oxidase immobilization

Valquiria da Cruz Rodrigues Barioto 16 July 2009 (has links)
Neste trabalho, foram fabricados biossensores amperométricos a partir do uso da polifenol oxidase (PFO), obtida do abacate como fonte enzimática, imobilizada em filmes de polipirrol (PPI) e que foram eletrossintetizados em meio de três diferentes eletrólitos de suporte (NaCl e NaClO4 e NaDDS). O método de imobilização enzimática foi o da adsorção, sendo a solução de enzima adicionada à solução com o pirrol e o eletrólito durante o processo de eletropolimerização. Os filmes de PPI/PFO foram caracterizados por técnicas eletroquímicas, principalmente por voltametria cíclica. A detecção de compostos fenólicos (catecol e pirogalol) foi realizada pela técnica de cronoamperometria após se variar a concentração do analito. A morfologia dos filmes foi estudada por microscopia de força atômica (AFM), sendo observado que a presença da enzima no filme polimérico assim como o uso de diferentes eletrólitos de suporte levou a diferenças na superfície dos filmes. Além disto, verificou-se que o biossensor construído a partir do uso do NaCl, apresentava uma resposta mais eficiente, ou seja, ele foi capaz de detectar catecol e pirogalol em um menor limite de detecção. / In this study amperometric biosensors were manufactured from the use of polyphenol oxidase (PPO) obtained from avocado as a source of enzyme immobilized in polypyrrole (PPY) films that were electrosynthesized with three different support electrolytes (NaCl, NaClO4 and NaDDS). The method of enzyme immobilization was the adsorption. The PPO was added in the solution containing pyrrole and electrolyte during electropolymerization. The PPY/PPO films were characterized by electrochemical techniques mainly by cyclic voltammetry. Detection of phenolic compounds (catechol and pyrogallol) was performed by the technique of chronoamperometry after varying the concentration of the analyte. The morphology of the films was studied by the atomic force microscopy (AFM) and observed that the presence of the enzyme in the polymer film and the use of different electrolytes support led to differences in the surface of films. However it was found that the biosensor constructed from the use of NaCl showed more efficient response and it was able to detect catechol and pyrogallol in a lower limit of detection.

Page generated in 0.0287 seconds