• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Identification of antistatic/antifogging agents in polymers, including used plastic packaging / Identifiering av antistatiska och antifogging additiv i polymerer, inklusive använda plastförpackningar

Lund, Rebecka, Ibrahim, Raam, Johansson, Emil January 2021 (has links)
Huvudmålet i projektet var att analysera det vanligt förekommande additivet glycerolmonostearat, GMS, i plastprover. Projektet är en del av ett samarbete mellan KTH och det norska företaget Norner. Projektgruppen har jobbat för att utvärdera och optimera företagets nuvarande analysmetod samt att identifiera glycerolmonostearat i polypropylen. Olika lösningsmedel och derivatiseringsreagens testades, såväl som olika temperaturprofiler, för gaskromatografen jämfördes under projektet. Resultaten visade att glycerolmonostearat kunde derivatiseras genom silylering. Alla prover har sammanfattats i en slutgiltig metod som är lämpad för analys av polyolefiner som innehåller glycerolmonostearat. Slutmetoden saknade möjligheten för kvantitativ analys och kan därför förbättras i framtiden. / The main task was to analyze the very common additive, glycerol monostearate, GMS in plastic samples. The project was a collaboration between KTH students and the Norwegian company Norner. The goal was to evaluate and optimize the company's current method of analysis and identification of the content of GMS in polyolefins. Different solvents, derivatization agents and methods for gas chromatography were compared to find an effective process by which additives in polypropylene samples can be analyzed. The results showed that glycerol monostearate can be derivatized through a process called silylation. All different attempts have been summarized into one final method that was most suitable for the analysis of polyolefins containing glycerol monostearate. The final method was reproducible but lacked a properly determined quantification analysis. The final method can be improved further after this project. To give a few examples there are a lot more potential derivatization agents and solvents that can be substituted which requires further research.
2

Analytical Methods for High Molecular Weight UV Stabilizers / Analytiska metoder för UV-stabilisatorer med hög molekylvikt

Ljungström, Elin January 2022 (has links)
Utomhusprodukter gjorda i plast är sårbara för nedbrytning på grund av UV-energi från solljus. För att stoppa denna fotonedbrytning används UV-stabilisatorer i plastmaterial; en av huvudkategorierna är hindrade aminljusstabilisatorer (HALS, hindered amine light stabilizers). Detta projekt ämnade att utveckla analytiska metoder passande för polymera HALS-föreningar som används i polyolefin-produkter. Huvudfokuset låg på vätskekromatografi med antingen UV eller masspektrometri (MS) detektion. Identifiering lyckades till viss del, extraktion misslyckades, och det gjordes inga kvantifieringsförsök. Detta examensarbete utfördes som ett samarbete mellan KTH och företaget Norner AS. På grund av detta har detaljerna såsom vilka HALS som användes, hur sammansättningen av elueringsgradienter förändrades och masspektrum från MS analys tagits bort eller ändrats till generiska termer. Högpresterande vätskekromatografi (HPLC, high-performance liquid chromatography) med metoden normalfas (normal phase) ansågs vara ett otillfredsställande alternativ på grund av begränsningen av lämpliga lösningsmedel. Både för HPLC och LC-MS-analys användes omvänd fas (reverse phase) med en C18 50 mm kolonn. Gällande HPLC-analys visade sig en våglängd på 240 nm för UV-detektion vara lämplig. För MS-detektion användes positiv elektrosprayjonisering på grund av föreningarnas basiska pKa-värden. Elueringsgradienten med de mest tillfredsställande resultaten var gradientversion 5, med vatten som lösningsmedel A och metanol som lösningsmedel B. En variant av denna gradient användes för LC-MS; gradientversion 5 mod följer samma mönster men med vatten + Y vol% syra som lösningsmedel A, för att möjliggöra jonisering. Additiv UV 2 har låg löslighet i polära lösningsmedel, men genom förtvålning kunde additiv UV 2 lösas i metanol. Med gradientversion 5 mod har förtvålad additiv UV 2 en retentionstid på 1,2 minuter i både HPLC och LC-MS-analys. För HPLC-analys av additiv UV 3 användes gradientversion 5 som resulterade med en retentionstid på 16,8 minuter, och för LC-MS med gradientversion 5 mod 16 minuter. Analys av additiv UV 5 med HPLC gav en retentionstid på 2 minuter med gradientversion 5, och för LC-MS-analys med gradientversion 5 mod var retentionstiden 1,3 minuter. På grund av inkonsekventa resultat mellan HPLC-analyser eller mellan HPLC och LC-MS-resultat kunde inte retentionstid för identifiering av additiven UV 1, UV 4 och UV 6 bestämmas. Extraktion av polymerprover med olika HALS gjordes i toluen vid 80 °C under en timme. I HPLC var det ingen skillnad i kromatogrammen mellan de olika HALS-produkterna. Resultaten från LC-MS stödde resultaten från HPLC, så slutsatsen att extraktionsmetoden inte var framgångsrik drogs. En anledning till detta kan vara att detektionsgränsen i MS och UV överstiger den extraherade halten av HALS. / Outdoor plastic products are vulnerable to degradation due to UV energy from sunlight. To hinder this photodegradation UV stabilizers are used in plastic materials; one of the main categories is hindered amine light stabilizers (HALS). This project aimed to develop analytical methods suitable for polymeric HALS used in polyolefin products. Liquid chromatography was the primary analytical method, with either UV or mass spectrometry (MS) detection. Identification of HALS was partially successful, the attempted extraction was unsuccessful, and there was no attempt at quantification. This thesis was performed as a collaboration between KTH and the company Norner AS. Due to this, the details such as which HALS were used, how the composition of elution gradients changed, and the mass spectrum from MS analysis have been removed or changed to generic terms. The high-performance liquid chromatography (HPLC) method normal phase was deemed as an unsatisfactory option due to the limitation of appropriate solvents. For HPLC and LC-MS analysis reversed phase with a C18 50 mm column was used. In HPLC analysis, a wavelength of 240 nm for UV detection was found to be suitable. For MS detection, positive electrospray ionization was used due to the compounds' basic pKa values. The elution gradient with the most satisfactory results was gradient version 5, with water as solvent A and methanol as solvent B. A variant of this gradient was used for LC-MS; gradient version 5 mod follows the same pattern but with water + Y vol% acid as solvent A, to enable ionization. UV 2 has low solubility in polar solvents, but through saponification UV 2 could be dissolved in methanol. With gradient version 5 mod, saponified UV 2 has a retention time of 1.2 minutes in both HPLC and LC-MS analysis. For HPLC analysis of additive UV 3, gradient version 5 was used which resulted in a retention time of 16.8 minutes, and for LC-MS with gradient version 5 mod 16 minutes. Analysis of UV 5 with HPLC gave a retention time of 2 minutes with gradient version 5, and for LC-MS analysis with gradient version 5 mod the retention time was 1.3 minutes. Due to inconsistency in results between HPLC analysis or between HPLC and LC-MS results, retention time for identification of additives UV 1, UV 4, and UV 6 could not be stated.  Extraction of polymer samples with different HALS was done in toluene at 80 ॰C for one hour. In HPLC, there was no difference in the chromatograms between the different HALS compounds. The results from LC-MS supported the results from HPLC, thus it was concluded that the extraction method was not successful. A reason for this could be that the detection limit in MS and UV might exceed the extracted amounts of the compounds.
3

Tolkning av spektrum från Fourier transform infraröd spektroskopi (FTIR) på industriella termoplaster

Schön, Martin, Andersson, Daniel January 2007 (has links)
Polykemi AB använder kontinuerligt FTIR-analys för materialidentifiering, felsökning och utveckling. Företaget har ett omfattande referensbibliotek med spektra för råvaror i form av polymerer, additiv, fyllmedel och förstärkningsmedel. Företaget köper rena polymerer som modifieras genom att polymer och fyllmedel blandas i en extruder och en plastsammansättning erhålls.Den praktiska delen av examensarbetet inleddes med upptagande av FTIR-spektrer från några av de termoplaster, additiv, fyllmedel och förstärkningsmedel som företaget använder. Slutligen upptogs spektrer från ett antal modifierade plaster. Dessa spektrer tolkades och de ingående ämnena identifierades.Två olika metoder har använts vid analyserna: filmteknik och diffus reflektans. Vid studien av de modifierade plasterna användes även utbränning av proverna för att underlätta identifikation av oorganiska fyllmedel.Syftet är att examensarbetet ska kunna användas för att öka den befintliga kompetensnivån avseende FTIR-analys. / Polykemi AB uses FTIR-analysis continuously in material identification, trouble shooting and development. The company has an extensive library of references containing spectra of raw material (polymers, additives, filling materials and fortifiers). The company buy pure polymers which are modified by mixing with filling material in an extruder, which result in a polymeric compound. The practical part of this bachelor thesis was initiated with collecting of FTIR-spectra from some of the thermopolymers, additives, filling materials and fortifiers which the company uses. Finally spectra of some polymeric compounds were collected.These spectra were interpreted and the included materials were identified.Two different methods were used to collect spectra: polymer film and diffuse reflectance. In the study of modified polymers burnout was used to facilitate the identification of inorganic filling materials.The purpose of this bachelor thesis is intended to increase the existing level of competence regarding FTIR-analysis.

Page generated in 0.0311 seconds