• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de diferentes materiais de cobertura, inclinações e exposições de telhado na temperatura interna em modelos reduzidos de instalações zootécnicas

Melo, Thiago Vasconcelos [UNESP] 17 November 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-11-17Bitstream added on 2014-06-13T20:25:12Z : No. of bitstreams: 1 melo_tv_dr_jabo.pdf: 821013 bytes, checksum: 4769ca1d18e7f8df5a7aba46280f6610 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho foi desenvolvido junto aos Departamentos de Engenharia Rural e Morfologia e Fisiologia Animal da FCAV/Unesp, Jaboticabal, SP. Teve como objetivo verificar a influencia da inclinação e exposição norte e sul com a telha de telha cerâmica, aço galvanizado e fibrocimento sobre a temperatura interna de modelos reduzidos de instalações zootécnica. Para o desenvolvimento do projeto de pesquisa foram utilizados 48 modelos reduzidos nas dimensões de 1,00 x 1,00 x 0,50 metros. A cobertura foi de uma água, dispostos nas exposições Norte-Sul, laterais e piso de compensado de madeira, sendo 24 modelos na exposição norte e 24 na sul. Foram utilizadas na cobertura, telha de cerâmica, aço galvanizado e fibrocimento. As inclinações variaram de 20, 30, 40 e 50% para telha de cerâmica e 10, 30, 40 e 50% para as demais. No interior dos modelos foram realizadas leituras de temperatura, de hora em hora durante um ano, pelo sistema de aquisição de dados Marca Campbell Scientific-Ínc. Externamente foram medidas e registradas a temperatura do ar, radiação solar global incidente, precipitação, velocidade e umidade relativa do ar pela estação meteorológica do departamento de Ciências Exatas da FCAV/Unesp, Jaboticabal, SP. Os resultados obtidos foram avaliados num modelo linear geral no esquema fatorial aninhado 3X4X2, em que foram considerados: tipo de telha, grau de inclinação e exposição, onde os efeitos de cobertura e exposição foram aninhados no fator inclinação. As médias obtidas foram comparadas pelo teste de Tukey a 5% de probabilidade. Foram analisadas a temperatura interna, calor retido e diferença de temperatura máxima interna – temperatura máxima externa. Após analise dos dados observa-se que com o aumento da inclinação na exposição sul, houve decréscimo da temperatura interna no interior do modelo nas coordenadas geográficas da cidade de Jaboticabal / The present study was developed in Departamentos de Engenharia Rural e Morfologia e Fisiologia Animal da FCAV/Unesp, Jaboticabal, SP with the objective of evaluating different covering materials, inclinations and exhibitions of the roof in inside temperature in reduced models in zootechnics installations. For the development of the research project 48 built reduced models of wood were used with dimensions of 1,00 x 1,00 x 0,50 meters. The covering was one water, lateral and wood floor, disposed in the exhibitions North-south, being 24 prototypes in the north exhibition and 24 in the south. Were used in the covering roofs of ceramic type, galvanized steel and asbestos. The inclinations varied of 20, 30, 40 and 50% for ceramic tile and 10, 30, 40 and 50% for the others and with two repetitions for inclination. Inside the reduced models temperature readings were accomplished, of hour in hour during one year, for the system of acquisition of Data Logger Campbell Scientific-Ínc and externally the temperature of the air, incident radiation global solar, precipitation, speed and relative humidity of the air were measured. The results obtained during the experimental period of one year were appraised statistically for the statistical package SAS in the factorial outline, where three factors were considered: tile type, inclination degree and exhibition. The obtained averages were compared through the test of Tukey to 5% of probability. After analyzing the data we found that with increasing slope, there was a decrease in inside temperature in the cover prototypes, therefore, using steeper slopes with 50% of tipping ceramics and asbestos, with greater coverage on display South, we have lower temperatures in poultry houses in the geographic coordinates of the city of Jaboticabal
2

Avaliação de diferentes materiais de cobertura, inclinações e exposições de telhado na temperatura interna em modelos reduzidos de instalações zootécnicas /

Melo, Thiago Vasconcelos. January 2010 (has links)
Resumo: O presente trabalho foi desenvolvido junto aos Departamentos de Engenharia Rural e Morfologia e Fisiologia Animal da FCAV/Unesp, Jaboticabal, SP. Teve como objetivo verificar a influencia da inclinação e exposição norte e sul com a telha de telha cerâmica, aço galvanizado e fibrocimento sobre a temperatura interna de modelos reduzidos de instalações zootécnica. Para o desenvolvimento do projeto de pesquisa foram utilizados 48 modelos reduzidos nas dimensões de 1,00 x 1,00 x 0,50 metros. A cobertura foi de uma água, dispostos nas exposições Norte-Sul, laterais e piso de compensado de madeira, sendo 24 modelos na exposição norte e 24 na sul. Foram utilizadas na cobertura, telha de cerâmica, aço galvanizado e fibrocimento. As inclinações variaram de 20, 30, 40 e 50% para telha de cerâmica e 10, 30, 40 e 50% para as demais. No interior dos modelos foram realizadas leituras de temperatura, de hora em hora durante um ano, pelo sistema de aquisição de dados Marca Campbell Scientific-Ínc. Externamente foram medidas e registradas a temperatura do ar, radiação solar global incidente, precipitação, velocidade e umidade relativa do ar pela estação meteorológica do departamento de Ciências Exatas da FCAV/Unesp, Jaboticabal, SP. Os resultados obtidos foram avaliados num modelo linear geral no esquema fatorial aninhado 3X4X2, em que foram considerados: tipo de telha, grau de inclinação e exposição, onde os efeitos de cobertura e exposição foram aninhados no fator inclinação. As médias obtidas foram comparadas pelo teste de Tukey a 5% de probabilidade. Foram analisadas a temperatura interna, calor retido e diferença de temperatura máxima interna - temperatura máxima externa. Após analise dos dados observa-se que com o aumento da inclinação na exposição sul, houve decréscimo da temperatura interna no interior do modelo nas coordenadas geográficas da cidade de Jaboticabal / Abstract: The present study was developed in Departamentos de Engenharia Rural e Morfologia e Fisiologia Animal da FCAV/Unesp, Jaboticabal, SP with the objective of evaluating different covering materials, inclinations and exhibitions of the roof in inside temperature in reduced models in zootechnics installations. For the development of the research project 48 built reduced models of wood were used with dimensions of 1,00 x 1,00 x 0,50 meters. The covering was one water, lateral and wood floor, disposed in the exhibitions North-south, being 24 prototypes in the north exhibition and 24 in the south. Were used in the covering roofs of ceramic type, galvanized steel and asbestos. The inclinations varied of 20, 30, 40 and 50% for ceramic tile and 10, 30, 40 and 50% for the others and with two repetitions for inclination. Inside the reduced models temperature readings were accomplished, of hour in hour during one year, for the system of acquisition of Data Logger Campbell Scientific-Ínc and externally the temperature of the air, incident radiation global solar, precipitation, speed and relative humidity of the air were measured. The results obtained during the experimental period of one year were appraised statistically for the statistical package SAS in the factorial outline, where three factors were considered: tile type, inclination degree and exhibition. The obtained averages were compared through the test of Tukey to 5% of probability. After analyzing the data we found that with increasing slope, there was a decrease in inside temperature in the cover prototypes, therefore, using steeper slopes with 50% of tipping ceramics and asbestos, with greater coverage on display South, we have lower temperatures in poultry houses in the geographic coordinates of the city of Jaboticabal / Orientador: Renato Luis Furlan / Coorientador: Adhemar Pitelli Milani / Banca: Adolpho Marlon Antoniol de Moura / Banca: Danísio Prado Munar / Banca: Fernando Augusto Curvello / Banca: Jorge de Lucas Junior / Doutor
3

Comparação de projetos arquitetônicos para otimização de eficiência energética e conforto ambiental em aviários de frangos de corte para o oeste do Paraná / Comparison of architectural projects to optimize energy efficiency and environmental comfort in broiler house in the western region of Paraná State, Brazil

Dalmina Júnior, Moacir José 09 March 2018 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-06-26T14:49:41Z No. of bitstreams: 2 Moacir_Dalmina_Junior.pdf: 4328726 bytes, checksum: 62b2315c55523ed5b1130daa6a03b4ce (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-26T14:49:41Z (GMT). No. of bitstreams: 2 Moacir_Dalmina_Junior.pdf: 4328726 bytes, checksum: 62b2315c55523ed5b1130daa6a03b4ce (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-09 / The high cost of production is one of the greatest challenges in poultry and the energy cost is one of the main factors for the final value of the product. So, the proposed study seeks to minimize and enhance the energetic lighting and ventilation system of broiler houses in the western region of Paraná state, Brazil. The objective of the present study was to develop a comparison of three design models of broiler houses to improve energy efficiency and environmental comfort of confined poultry. Thus the research analyzed two models of broiler houses existing in the market, the open-sided broiler house and the dark house models, in addition to a third model the proposed system that has as characteristics a brise-soleil system and cross ventilation, which uses natural resources to help in the thermal efficiency of the broiler house, minimizing energy costs and providing better animal comfort.Therefore, they result in a production gain, which helps the systems currently used. Thus, the study sought to develop a mixed system between project actions to better use of natural lighting and ventilation, as well as the use of electric heating and ventilation systems that have been used in commercial broiler houses. The models were developed using Autodesk Revit™ software, and the results were obtained through Green Building Studio™. The methodology used was the comparison of the models and analysis of the energy consumption of the buildings during the year. The outcome allowed us to conclude that the broiler house model proposed for this study was 20.97% more efficient than the open-sided model and 58.21% more efficient than the dark house model. / O alto custo de produção é um dos maiores desafios na avicultura de corte e o custo energético é um dos principais fatores pelo valor final do produto, por isso o estudo proposto busca minimizar e tornar mais eficiente energeticamente o sistema de iluminação e ventilação de aviários de corte no oeste do Paraná. O objetivo do presente estudo foi desenvolver uma comparação de três modelos de projeto para melhor eficiência energética e conforto ambiental de aves de cortes em confinamento. Assim a pesquisa analisou dois modelos de aviários existentes no mercado, o convencional aberto e o dark house, além de um terceiro modelo o sistema proposto que tem como características realizar um sistema de brises bloqueadores solares e de ventilação cruzada, que utilizem recursos naturais para auxiliar na eficiência térmica do aviário, minimizando custos com energia e proporcionando um melhor conforto dos animais. Desta forma resultem em ganho de produção, que vem servir de auxílio aos sistemas atualmente utilizados. Assim o estudo buscou desenvolver um sistema misto entre ações de projeto para melhor aproveitamento de iluminação e ventilação natural, mas com a utilização conjunta de sistemas elétricos de aquecimento e ventilação que atualmente são utilizados em aviários comerciais. Os modelos foram desenvolvidos através do software Revit da Autodesk, e os resultados foram obtidos através Green Building Studio. A metodologia utilizada foi a comparação dos modelos e análise do consumo energético das edificações durante o ano. Os resultados permitiram concluir que o modelo de aviário proposto para o estudo foi 20,97% mais eficiente que o modelo aberto convencional e 58,21% mais eficiente do que o modelo dark house.

Page generated in 0.0346 seconds