• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • 2
  • 1
  • Tagged with
  • 16
  • 16
  • 16
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise crítica da rota tecnológica adotada no desenvolvimento de equipamento sinalizador de faltas para redes aéreas de distribuição de energia elétrica. / Critical analysis of the technological route adopted for development of faulted circuit indicator equipment for aerial power distribution network.

Andrade, Fábio José de 20 April 2012 (has links)
Um equipamento sinalizador luminoso de faltas foi desenvolvido pela Companhia Paulista de Força e Luz (CPFL) em parceria com a Escola Politécnica da USP e a empresa Expertise Engenharia Ltda., através de uma série de projetos de pesquisa incluídos no programa de pesquisa e desenvolvimento (P&D) regido pela Agência Nacional de Energia Elétrica (ANEEL) brasileira. Neste trabalho é feita uma análise crítica da rota tecnológica adotada no desenvolvimento do sinalizador de faltas, apontando detalhes e justificativas das escolhas tecnológicas adotadas, além de novas possibilidades de melhoria do equipamento face aos avanços tecnológicos detectados nos últimos anos. Para tanto, é proposto e aplicado um novo método, associado a uma sistematização, para análise comparativa de tecnologias, que considera dados quantitativos, qualitativos e estratégicos diretamente comparáveis entre si. Ao longo do trabalho são analisados as escolhas dos princípios de detecção de faltas e funcionalidades agregadas, o desenvolvimento da eletrônica e dos circuitos integrados do detector de faltas, a fonte de alimentação, a sinalização luminosa e o gabinete do equipamento. Como resultado da linha de pesquisa do sinalizador luminoso de faltas foram obtidos protótipos de prova de conceito, cabeça-de-série e de lote pioneiro, estes últimos prontos e certificados para inserção no mercado. Obtiveram-se também diversas publicações em congressos nacionais, a geração de dois pedidos de patentes e um sistema computacional de alocação otimizada de sinalizadores de faltas em redes de distribuição aérea de energia elétrica. / Within the R&D program governed by the National Agency of Electric Energy of Brazil, a luminous faulted circuit indicator equipment (FCI) was developed by the Companhia Paulista de Força e Luz (CPFL) in partnership with the Escola Politécnica da USP and the company Expertise Engenharia Ltda. In this work it is presented a critical analysis of the technological route adopted for development of this new FCI, indicating details and justifications of technological choices adopted, and new detected possibilities for improvements, taken into account the technological advances in recent years. For such purpose, it is proposed a new method, associated to a practical systematization, for comparative analysis of technologies that accounts for quantitative, qualitative and strategic data directly comparable. The work presents analyses on the choices of fault detection principles and related functions, the development of integrated circuits and fault detector electronics, the power supply, the luminous signaling and the equipment case. As results of the research and development of the FCI there were obtained proof of concept, prototype and pilot equipments, the last ones certified and ready for sale. There were also obtained several publications in national conferences, submission of two patent applications and a software for optimization of FCIs allocation on overhead power distribution networks.
12

ANÁLISE PROBABILÍSTICA DA CONFORMIDADE DE TENSÃO EM REDES DE DISTRIBUIÇÃO CONSIDERANDO A PRESENÇA DE GERAÇÃO DISTRIBUÍDA. / Probabilistic analysis of voltage conformity in distribution networks considering distributed generation presence.

VIEIRA, Carlos Henrique da Silva 09 November 2012 (has links)
Submitted by Maria Aparecida (cidazen@gmail.com) on 2017-08-24T15:21:43Z No. of bitstreams: 1 Carlos Henrique.pdf: 3192728 bytes, checksum: b409baf77eae63d413fff22f89c2f1d9 (MD5) / Made available in DSpace on 2017-08-24T15:21:43Z (GMT). No. of bitstreams: 1 Carlos Henrique.pdf: 3192728 bytes, checksum: b409baf77eae63d413fff22f89c2f1d9 (MD5) Previous issue date: 2012-11-09 / FAPEMA / Currently, there is growing concern about the Power Quality (PQ) problems due to: introduction of automation in industrial processes, presence of personal computers and electronically controlled devices, load equipments with low capacity to withstand small PQ disturbances and increased perception of residential and industrial consumers with regard to PQ disturbances. In this context, an important issue with relation to PQ is the voltage conformity. That is, the adequacy of service voltage to the limits specified by regulatory agencies. The concern about compliance is due to the following problems caused by sustained undervoltages and overvoltages: improper or less-efficient equipment operation, tripping of sensitive loads, overheating of induction motors due to undervoltages, equipment damage or failure due to overvoltages and higher no-load losses in transformers caused by sustained overvoltages. Furthermore, there have been various incentives for connection of Distributed Generation (DG) in distribution networks due to: incentives for the using of electricity generation based on renewable energy sources and free access of independent energy producers to transmission and distribution networks owing to deregulation of the electric sector. In principle, the voltage profile of a distribution network can be improved with connection of DG. However, it is possible to notice severe deteriorations in the voltage profile of distribution networks in DG post-failure scenarios. These failures are caused by problems in the DG components, such as: cooling system, gears, turbines, etc. During the time period in which the DG is under repair, active and reactive power supports to correct the voltage profile are unavailable. Consequently, the voltage profile tends to deteriorate while the DG is disconnected. In this way, it is important to carry out studies to assess the impact of the DG installation on the voltage conformity indices considering the following issues: DG unavailability after an intrinsic failure and load curve. These aspects are subject to uncertainties due its random nature. Due to this, the most suitable approaches to assess the impact of uncertainties associated with load fluctuations and DG failures on the voltage conformity indices are the probabilistic methods. The main advantage of these methods is its capability to combine severity and probability to truly express the system risk. The main objective of this dissertation is the development of a method that models the random behavior of the distribution network in the voltage conformity indices estimation through the probabilistic methods. Models and techniques to incorporate stochastic variations in the demand and DG unavailability in voltage conformity indices estimation are proposed. The technique proposed in this dissertation to carry a Predictive Assessment of Voltage Conformity (PAVC) is based on the combination of the following techniques: power flow for radial distribution networks via current summation method, Quasi-Sequential Monte Carlo Simulation and Fourier analysis of time series. The PAVC model proposed in this dissertation was tested in 32 buses system. The results obtained with this system demonstrated that the DG has a great potential to improve the voltage conformity indices in the distribution network. However, the most significant improvements in the voltage conformity indices are associated with load points distant from the substation. Furthermore, it can be observed that the uncertainties associated with DG failures cause significant variations in the voltage conformity indices. Additionally, a sensitivity study demonstrated that the voltage conformity indices are worse (better) for systems where the load is modeled as constant power (impedance). / Atualmente há um interesse crescente com relação a problemas de Qualidade de Energia Elétrica (QEE) devido a: introdução de automação em processos industriais; presença de computadores pessoais e dispositivos controlados eletronicamente em instalações residenciais; equipamentos de carga com baixa capacidade para suportar pequenos distúrbios de qualidade de energia; e aumento da percepção dos consumidores industriais e residenciais com relação a distúrbios de QEE. Neste contexto, um aspecto importante com relação a QEE é a conformidade de tensão da rede de distribuição. Ou seja, a adequação da tensão de atendimento aos limites especificados pelos órgãos reguladores. A preocupação com a conformidade de tensão é devido aos seguintes problemas causados por subtensões e sobretensões sustentadas: operação indevida ou com baixa eficiência dos equipamentos elétricos dos consumidores; desligamento de cargas sensíveis; aquecimento de motores de indução devido à subtensões; danos ou falhas em equipamentos devido à sobretensões e aumento nas perdas em vazio nos transformadores causado pela presença de sobretensões sustentadas. Além disso, tem havido diversos incentivos para conexão de Geração Distribuída (GD) na rede de distribuição devido a: incentivo para utilização de sistemas de geração de energia elétrica baseados em fontes de energia renováveis; e livre acesso dos produtores independentes de energia às redes de transmissão e distribuição devido a desregulamentação do setor elétrico. Em princípio, o perfil de tensão de uma rede de distribuição pode ser melhorado com a conexão da GD. Contudo é possível observar deteriorações severas no perfil de tensão de redes de distribuição em cenários pós-falha da GD. Estas falhas são causadas por problemas nos componentes da GD, tais como: sistema de refrigeração, engrenagens, turbina, etc. Durante o período de tempo em que a GD está em reparo, o suporte de potência ativa e reativa da GD, para corrigir o perfil de tensão, está indisponível. Consequentemente, o perfil de tensão tende a se deteriorar enquanto a GD estiver desconectada. Desta forma, é importante realizar estudos para avaliar o impacto da instalação da GD nos índices de conformidade de tensão considerando os seguintes aspectos: indisponibilidade da GD após uma falha intrínseca e a curva de carga. Estes aspectos estão sujeitos a incertezas devido a sua natureza aleatória. Devido a isto, as técnicas mais adequadas para avaliar o impacto de incertezas associadas com flutuações de carga e falhas na GD nos índices de conformidade de tensão são os métodos probabilísticos. A principal vantagem destes métodos é a sua capacidade para combinar severidade e probabilidade para expressar verdadeiramente o risco do sistema. O principal objetivo desta dissertação é o desenvolvimento de um método que modele o comportamento aleatório da rede de distribuição na estimação dos índices de conformidade de tensão através de métodos probabilísticos. Modelos e técnicas para incorporar variações estocásticas na demanda e a indisponibilidade da GD na estimação dos índices de conformidade de tensão são propostos. A técnica proposta nesta dissertação para realizar uma Avaliação Preditiva da Conformidade de Tensão (APCT) se baseia na combinação das seguintes técnicas: fluxo de potência para redes de distribuição radiais via método de soma de correntes; simulação Monte Carlo Quasi-Sequencial e análise de Fourier de séries temporais. O modelo de APCT proposto neste artigo foi testado em um sistema de 32 barras. Os resultados obtidos neste sistema demonstraram que a GD tem um grande potencial para melhorar os índices de conformidade de tensão na rede de distribuição. Contudo, as melhorias mais significativas nos índices de conformidade estão associadas com os pontos de carga mais distantes da subestação. Além disso, pode-se observar que as incertezas associadas com as falhas na GD causam variações significativas nos índices de conformidade de tensão. Adicionalmente, um estudo de sensibilidade demonstrou que os índices de conformidade de tensão são piores (melhores) para sistemas onde a carga é modelada como potência (impedância) constante.
13

AVALIAÇÃO PROBABILÍSTICA DO IMPACTO DA GERAÇÃO DISTRIBUÍDA EÓLICA NOS AFUNDAMENTOS DE TENSÃO DE CURTA DURAÇÃO. / PROBABILISTIC ASSESSMENT OF THE IMPACT OF DISTRIBUTED GENERATION WIND POWER IN THE SHORT TERM VOLTAGE SAGS .

SILVA, Tiago Alencar 09 November 2012 (has links)
Submitted by Maria Aparecida (cidazen@gmail.com) on 2017-08-29T13:12:16Z No. of bitstreams: 1 Tiago Silva.pdf: 3175763 bytes, checksum: 8eba0f17a1a1f6fa2606a5235969987e (MD5) / Made available in DSpace on 2017-08-29T13:12:16Z (GMT). No. of bitstreams: 1 Tiago Silva.pdf: 3175763 bytes, checksum: 8eba0f17a1a1f6fa2606a5235969987e (MD5) Previous issue date: 2012-11-09 / CNPQ / The Distributed Generation (DG) can improve the power quality indices associated with Short Duration Voltage Variations (SDVV) due to the reduction in the electric network loading, which in turn causes an improvement in the pre-fault voltage profile. On the other hand, the DG can also deteriorates the power quality indices related to SDVV due to the increasing in the fault currents, which in turns reduce the post-fault voltages. Furthermore, the assessment of the DG impact on SDVV is more difficult with the presence of renewable energy resources. This complexity is due to fluctuations in output power caused by stochastic variations in the primary energy source (sun, wind, tide levels, etc.). Additionally, the bibliographical review on Predictive Assessment of Short Duration Voltage Variations (PAVV) revealed that none of the existing methodology considered the impact of fluctuations in the output power of a wind DG on power quality indices related to SDVV. It was also noticed that the load variations during the study period are ignored in the papers on SDVV. The existence of these deficiencies and the governmental incentives for the use of wind generation motivated this research. The main aim of this dissertation is the development of a methodology for the PAVV capable of recognizing uncertainties associated with wind DG and load fluctuations. The modeling of these uncertainties was carried out using NonSequential Monte Carlo Simulation (MCS). The nodal voltages in the fault scenarios generated by MCS were evaluated using the Admittance Summation Method (ASM) in phase coordinates. The combination of the MCS with the ASM allowed estimating the following indices related to SDVV: the expected value of the SARFI (“System Average RMS – Variation – Frequency Index”) and expected nodal frequency of SDVV. Furthermore, the probability distributions and box plots of the SARFI index have been obtained. The proposed method for the PAVV was tested and validated in a test system with 32 buses. The tests results demonstrated that the DG insertion causes an improvement in the power quality indices associated with SDVV. Additionally, the substitution of conventional DG by wind DG cause a small deterioration in the power quality indices related to SDVV due to fluctuations in the output power of the wind DG. Finally, it was observed that the load fluctuations during the study period cause significant variations in the SARFI index. / A Geração Distribuída (GD) pode melhorar os índices de qualidade de energia associados com as Variações de Tensão de Curta Duração (VTCD) devido a redução no carregamento da rede elétrica, que por sua vez causa uma melhoria no perfil de tensão pré- falta. Por outro lado, a GD também pode degradar os índices de qualidade de energia associados com VTCD devido ao aumento nas correntes de falta, que por sua vez reduzem as tensões pós-falta. Além disso, a avaliação do impacto da DG sobre VTCD é mais difícil com a presença de fontes de energia renováveis. Esta complexidade se deve as flutuações na potência de saída causadas pelas variações estocásticas na fonte de energia primária (sol, vento, níveis de maré, etc.). Adicionalmente, a revisão bibliográfica realizada sobre Avaliação Preditiva de VTCD (APVT) revelou que nenhuma metodologia existente considerou o impacto de flutuações na potência de saída de geradores eólicos nos índices de qualidade referentes às VTCD. Também foi observado que flutuações de carga ao longo do período de estudo são desconsideradas nos artigos sobre APVT. A existência destas deficiências nos métodos de APVT e os incentivos governamentais para o uso de geração eólica motivaram esta pesquisa. O principal objetivo desta dissertação é o desenvolvimento de uma metodologia para a APVT capaz de reconhecer as incertezas associadas com a GD eólica e flutuações de carga. A modelagem destas incertezas na APVT foi realizada através do uso da Simulação Monte Carlo (SMC) não-sequencial. As tensões nodais nos cenários de falta gerados pela Simulação Monte Carlo (SMC) foram calculadas usando-se o Método de Soma de Admitância (MSA) em coordenadas de fase. A combinação da SMC com o MSA permitiu estimar os seguintes índices probabilísticos relacionados com as VTCD: valor esperado do SARFI (“System Average RMS – Variation – Frequency Index”) e frequência nodal esperada de VTCD. Além disso, foram obtidas distribuições de probabilidade e diagramas de caixa associados com o SARFI. O método proposto nesta dissertação para a APVT foi testado em uma rede de distribuição de 32 barras. Os resultados dos testes mostram que a inserção de GD causa uma melhoria nos índices de qualidade associados com as VTCD. Adicionalmente, a substituição de GD convencional por GD eólica causa uma pequena deterioração nos índices de qualidade referentes às VTCD devido as flutuações na potência de saída da GD eólica. Finalmente, também foi observado que as flutuações na carga ao longo do período de estudo causam variações significativas no índice SARFI.
14

Algoritmos de inteligência computacional utilizados na detecção de fraudes nas redes de distribuição de energia elétrica / Fraud detection in distribution networks using computacional intelligence algorithms

Queiroz, Altamira de Souza 19 February 2016 (has links)
Made available in DSpace on 2017-07-10T16:41:32Z (GMT). No. of bitstreams: 1 Dissertacao Altamira Queiroz2.pdf: 2299194 bytes, checksum: 07ecb127ebc11ad21a0cb551e23c2f1b (MD5) Previous issue date: 2016-02-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / One of the main problems currently faced by electric utilities is the occurrence of energy losses in the distribution network caused by fraud and electricity theft. Because of the financial losses and risks to public safety, the development of solutions to detect and combat fraud in the distribution networks is of the utmost importance. This work presents an analysis of computational intelligence algorithms to extract knowledge in databases with information from monthly energy consumption to identify consumption patterns with anomalies which could represent fraud. The algorithms Artificial Neural Networks and Support Vector Machines were tested to see which one perform better on the identification consumption patterns with abnormalities. Tests have shown that the algorithms used are able to detect patterns in electricity consumption curves, including special situations of fraud that manual techniques did not detect. / Um dos principais problemas que enfrentam atualmente as empresas concessionárias de energia elétrica é a ocorrência de perdas de energia na rede de distribuição, causadas por fraudes e furtos de energia elétrica. Sendo que tais problemas provocam prejuízos financeiros e também colocam em risco a segurança pública, é de grande interesse das concessionárias encontrar soluções para detectar e combater fraudes nas redes de distribuição de energia elétrica. Neste conceito, o presente trabalho apresenta uma análise dos algoritmos de Inteligência Computacional para extrair conhecimento de bases de dados de informações de consumo mensal de energia elétricas de usuários de uma determinada concessionária, a fim de identificar padrões de consumo com anomalias que representem possíveis fraudes nas redes de distribuição de energia elétrica. Para detectar padrões nas curvas de consumo, foram utilizados algoritmos de Redes Neurais Artificiais e Máquinas de Vetores de Suporte. Após a criação dos modelos, estes foram testados para verificar qual seria o melhor algoritmo para a detecção de padrões de consumo com anomalias, e os resultados obtidos, foram então, comparados com uma base de dados fornecida pela concessionária com a verificação manual dos usuários. Os testes demonstraram que os algoritmos utilizados são capazes de detectar padrões nas curvas de consumo de energia elétrica, inclusive detectando situações especiais de fraudes que técnicas manuais não detectaram.
15

Análise crítica da rota tecnológica adotada no desenvolvimento de equipamento sinalizador de faltas para redes aéreas de distribuição de energia elétrica. / Critical analysis of the technological route adopted for development of faulted circuit indicator equipment for aerial power distribution network.

Fábio José de Andrade 20 April 2012 (has links)
Um equipamento sinalizador luminoso de faltas foi desenvolvido pela Companhia Paulista de Força e Luz (CPFL) em parceria com a Escola Politécnica da USP e a empresa Expertise Engenharia Ltda., através de uma série de projetos de pesquisa incluídos no programa de pesquisa e desenvolvimento (P&D) regido pela Agência Nacional de Energia Elétrica (ANEEL) brasileira. Neste trabalho é feita uma análise crítica da rota tecnológica adotada no desenvolvimento do sinalizador de faltas, apontando detalhes e justificativas das escolhas tecnológicas adotadas, além de novas possibilidades de melhoria do equipamento face aos avanços tecnológicos detectados nos últimos anos. Para tanto, é proposto e aplicado um novo método, associado a uma sistematização, para análise comparativa de tecnologias, que considera dados quantitativos, qualitativos e estratégicos diretamente comparáveis entre si. Ao longo do trabalho são analisados as escolhas dos princípios de detecção de faltas e funcionalidades agregadas, o desenvolvimento da eletrônica e dos circuitos integrados do detector de faltas, a fonte de alimentação, a sinalização luminosa e o gabinete do equipamento. Como resultado da linha de pesquisa do sinalizador luminoso de faltas foram obtidos protótipos de prova de conceito, cabeça-de-série e de lote pioneiro, estes últimos prontos e certificados para inserção no mercado. Obtiveram-se também diversas publicações em congressos nacionais, a geração de dois pedidos de patentes e um sistema computacional de alocação otimizada de sinalizadores de faltas em redes de distribuição aérea de energia elétrica. / Within the R&D program governed by the National Agency of Electric Energy of Brazil, a luminous faulted circuit indicator equipment (FCI) was developed by the Companhia Paulista de Força e Luz (CPFL) in partnership with the Escola Politécnica da USP and the company Expertise Engenharia Ltda. In this work it is presented a critical analysis of the technological route adopted for development of this new FCI, indicating details and justifications of technological choices adopted, and new detected possibilities for improvements, taken into account the technological advances in recent years. For such purpose, it is proposed a new method, associated to a practical systematization, for comparative analysis of technologies that accounts for quantitative, qualitative and strategic data directly comparable. The work presents analyses on the choices of fault detection principles and related functions, the development of integrated circuits and fault detector electronics, the power supply, the luminous signaling and the equipment case. As results of the research and development of the FCI there were obtained proof of concept, prototype and pilot equipments, the last ones certified and ready for sale. There were also obtained several publications in national conferences, submission of two patent applications and a software for optimization of FCIs allocation on overhead power distribution networks.
16

Comunicação digital em canais PLC: técnicas de transmissão, detecção e caracterização de canais PLC outdoor brasileiros

Picorone, Antonio Angelo Missiaggia 22 August 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-25T12:36:15Z No. of bitstreams: 1 antonioangelomissiaggiapicorone.pdf: 6590019 bytes, checksum: 115ef6e90742599945ac5e9c8c44cb2c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-25T15:26:22Z (GMT) No. of bitstreams: 1 antonioangelomissiaggiapicorone.pdf: 6590019 bytes, checksum: 115ef6e90742599945ac5e9c8c44cb2c (MD5) / Made available in DSpace on 2017-04-25T15:26:22Z (GMT). No. of bitstreams: 1 antonioangelomissiaggiapicorone.pdf: 6590019 bytes, checksum: 115ef6e90742599945ac5e9c8c44cb2c (MD5) Previous issue date: 2014-08-22 / Esta tese discute a medição e a caracterização das redes de distribuição de energia elétrica de baixa tensão (RDE-BT) e externa (outdoor) como meio de comunicação de dados para sistemas power line communication (PLC). São apresentados e discutidos diversos parâmetros obtidos a partir de uma campanha de medição realizada na RDE-BT de uma concessionária brasileira. Dentre os parâmetros analisados destacam-se o tempo de coerência, banda de coerência, espalhamento do atraso, comprimento da resposta ao impulso do canal e capacidade do canal, quando se considera as bandas de frequências de 1,7 a 30 MHz, 1,7 a 50 MHz e 1,7 a 100 MHz. As análises estatísticas evidenciam o potencial da rede de energia elétrica como meio de comunicação e discute os limites dessa potencialidade. Além disso, são propostos modelos de densidade espectral de potência dos ruídos, caracterização esparsa de canais PLC e proposto um modelo para geração de canais PLC variantes no tempo, cujo tempo de coerência entre as realizações dos canais é controlado. A estimação de canais PLC é apresentada como uma oportunidade de aplicação das técnicas de amostragem compressiva. Os resultados relacionados com as modelagens propostas constituem um ferramental de grande utilidade para projetar e analisar o desempenho de sistemas PLC. / This dissertation aims at discussing the measurement and characterization of outdoor electric power grid of low voltage as communication medium (power line communication - PLC). Statistical analyses carried out on several parameters such as average channel gain, coherence time, coherence bandwidth, delay spread, length of the channel impulse response, and channel capacity, when it is considered the frequency bands from 1.7 to 30 MHz, from 1.7 up to 50 MHz, and from 1.7 up to 100 MHz, are presented. These analyses reveal the circumstances in which outdoor and low-voltage electric power grids can be advantageous to support a reliable and efficient PLC system operation. Moreover, power spectral density models of additive noise and sparse representation of PLC channels are proposed. Also, a PLC time-varying channels model generator that makes use of coherence time is introduced. The proposed model generator, which is validated with measured PLC channels, is an effective tool to carry out performance analysis of PLC systems. Finally, PLC channel estimation is highlighted as an opportunity for the application of compressive sampling-based techniques. The use of traditional OFDM - based channel estimation techniques and the ones based on compressive sensing gives some directions for advancing channel estimation techniques for PLC channels.

Page generated in 0.1194 seconds