Spelling suggestions: "subject:"power system"" "subject:"lower system""
21 |
The identification of electric power system dynamic equivalents from on-line measurements /Morris, Timothy John. January 1978 (has links) (PDF)
Thesis (M.E.) -- University of Adelaide, Dept. of Electrical Engineering, 1980. / Typescript (photocopy).
|
22 |
A real-time wide-area control for mitigating small-signal instability in large electric power systemsRestrepo, Jaime Quintero, January 2005 (has links) (PDF)
Thesis (Ph. D.)--Washington State University. / Includes bibliographical references.
|
23 |
Design of power system stabilizers based on modal and eigenvalue sensitivity analyses /Tse, Chi-tong. January 1990 (has links)
Thesis (Ph. D.)--University of Hong Kong, 1990.
|
24 |
Knowledge-based assessment and enhancement of voltage stability /Zhu, Tai-xiu. January 1996 (has links)
Thesis (Ph. D.)--University of Hong Kong, 1997. / Includes bibliographical references.
|
25 |
Methodologies for analysis of multiterminal HVDC systemsSánchez de Horcajo, J. J. January 1983 (has links)
Thesis (Ph. D.)--University of Wisconsin--Madison, 1983. / Typescript. Vita. eContent provider-neutral record in process. Description based on print version record. Bibliography; leaves 159-166.
|
26 |
Application of wide area frequency information from FNET to Power System Stabilizer (PSS) a thesis presented to the faculty of the Graduate School, Tennessee Technological University /Abhyankar, Shounak, January 2009 (has links)
Thesis (M.S.)--Tennessee Technological University, 2009. / Title from title page screen (viewed on June 29, 2010). Bibliography: leaves 105-108.
|
27 |
Interfacing dynamic phasor based system equivalents to an electromagnetic transient simulationKonara Mudiyanselage, Harshani Koushalya Konara 12 January 2016 (has links)
This thesis presents a method to do transient simulation of a large power system using dynamic phasors and electromagnetic transient simulation. A novel hybrid simulation technique using dynamic phasor equivalent is presented to analyse a part of a large power system. Electromagnetic transient simulation is used to model the part of the network that needs detailed simulation. The synchronous reference frame phase locked loop is implemented as the interface between the electromagnetic transient model and the dynamic phasor model. Two types of positive sequence filters i) sinusoidal signal integrator phase locked loop ii) extended phase locked loop are presented to eliminate the voltage unbalance effect in a phase locked loop. A comparison of the performance of the two filters is presented. The validation of the proposed interface is done using EMT simulation on real time digital simulator. Finally the numerical problems involved in this hybrid method are discussed. / February 2016
|
28 |
The application of contingency analysis to stability and security planning of the Blue Nile GridKarrar, Abdel Rahman Ali January 1991 (has links)
The Blue Nile Grid of Sudan, which supplies Electrical Power to the central region including the capital, Khartoum, has experienced a history of problems, of which the most important are the instability of the system and the generation shortages, which become particularly acute during certain months of the year. These problems have been complicated by a lack of real understanding of the system's behaviour, especially as it grows in size and complexity, and as the demand increases.
|
29 |
Optimal fault locationKnezev, Maja 15 May 2009 (has links)
Basic goal of power system is to continuously provide electrical energy to the users.
Like with any other system, failures in power system can occur. In those situations it is
critical that correct remedial actions are applied as soon as possible after the accurate fault
condition and location are detected. This thesis has been focusing on automated fault
location procedure.
Different fault location algorithms, classified according to the spatial placement of
physical measurements on single ended, multiple ended and sparse system-wide, are
investigated. As outcome of this review, methods are listed as function of different
parameters that influence their accuracy. This comparison is than used for generating
procedure for optimal fault location algorithm selection. According to available data, and
position of the fault with respect to the data, proposed procedure decides between
different algorithms and selects an optimal one. A new approach is developed by utilizing
different data structures such as binary tree and serialization in order to efficiently
implement algorithm decision engine.
After accuracy of algorithms is strongly influenced by available input data, different
data sources are recommended in proposed architecture such as the digital fault
recorders, circuit breaker monitoring, SCADA, power system model and etc. Algorithm
for determining faulted section is proposed based on the data from circuit breaker
monitoring devices. This algorithm works in real time by recognizing to which sequence
of events newly obtained recording belongs.
Software prototype of the proposed automated fault location analysis is developed
using Java programming language. Fault location analysis is automatically triggered by
appearance of new event files in a specific folder. The tests were carried out using the real
life transmission system as an example.
|
30 |
Optimal fault locationKnezev, Maja 10 October 2008 (has links)
Basic goal of power system is to continuously provide electrical energy to the users.
Like with any other system, failures in power system can occur. In those situations it is
critical that correct remedial actions are applied as soon as possible after the accurate fault
condition and location are detected. This thesis has been focusing on automated fault
location procedure.
Different fault location algorithms, classified according to the spatial placement of
physical measurements on single ended, multiple ended and sparse system-wide, are
investigated. As outcome of this review, methods are listed as function of different
parameters that influence their accuracy. This comparison is than used for generating
procedure for optimal fault location algorithm selection. According to available data, and
position of the fault with respect to the data, proposed procedure decides between
different algorithms and selects an optimal one. A new approach is developed by utilizing
different data structures such as binary tree and serialization in order to efficiently
implement algorithm decision engine.
After accuracy of algorithms is strongly influenced by available input data, different
data sources are recommended in proposed architecture such as the digital fault
recorders, circuit breaker monitoring, SCADA, power system model and etc. Algorithm
for determining faulted section is proposed based on the data from circuit breaker
monitoring devices. This algorithm works in real time by recognizing to which sequence
of events newly obtained recording belongs.
Software prototype of the proposed automated fault location analysis is developed
using Java programming language. Fault location analysis is automatically triggered by
appearance of new event files in a specific folder. The tests were carried out using the real
life transmission system as an example.
|
Page generated in 2.027 seconds