Spelling suggestions: "subject:"prótese"" "subject:"próteses""
1 |
Complicações pós-operatórias e avaliação microbiológica relacionadas a pacientes submetidos à instalação de implantes osseointegráveis para confecção de próteses auriculares implantorretidasSantos, Leandro Nascimento Rodrigues dos 26 June 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Marília Freitas (marilia@bce.unb.br) on 2015-10-26T11:37:41Z
No. of bitstreams: 1
2015_LeandroNascimentoRodriguesdosSantos.pdf: 10965703 bytes, checksum: 840d334305e17dabcd30137d13145e6c (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2015-11-12T13:10:28Z (GMT) No. of bitstreams: 1
2015_LeandroNascimentoRodriguesdosSantos.pdf: 10965703 bytes, checksum: 840d334305e17dabcd30137d13145e6c (MD5) / Made available in DSpace on 2015-11-12T13:10:28Z (GMT). No. of bitstreams: 1
2015_LeandroNascimentoRodriguesdosSantos.pdf: 10965703 bytes, checksum: 840d334305e17dabcd30137d13145e6c (MD5) / Defeitos faciais podem ser gerados por traumas, malformações congênitas e ressecções para tratamento de patologias. Independente da causa, a perda de substância facial promove prejuízos funcionais e estéticos, impacto psicológico e limita interações sociais. A reabilitação dos defeitos faciais pode ser realizada por meio cirúrgico e/ou protético. Próteses faciais apoiadas em implantes extraorais são uma opção de tratamento que permitem boa simetria e similaridade de cor e detalhes anatômicos, sendo uma opção alternativa após falhas do tratamento cirúrgico. Os objetivos do presente estudo são avaliar taxas de sobrevida e complicações, relacionadas à cirurgia de implantes com finalidade de reabilitação por próteses auriculares por meio de revisão bibliográfica; analisar diferenças microbiológicas na junção plataforma-pilar protético, considerando os efeitos da higienização do sistema, e ainda descrever o perfil microbiológico de dois pacientes reabilitados por próteses auriculares implantossuportadas. Para tal, um levantamento bibliográfico envolvendo vocabulário controlado e termos livres foi realizado na base de dados do PubMed. Em seguida foi conduzido um estudo in vitro em diferentes plataformas e conexões, para estabelecer diferenças no padrão microbiológico após métodos de higienização com solução de clorexidina. Por fim, foram descritas as diferenças no perfil de colonização e manejo de dois casos clínicos reabilitados por próteses auriculares, que apresentavam reações de tecidos moles. Perda de implantes e reações de pele/mucosa foram as complicações mais citadas. As taxas de sucesso variaram em torno de 90-100% de sucesso, dependendo de fatores como o local de instalação do implante e radiação prévia. Em laboratório, procedimentos de higienização com solução alcoólica de clorexidina à 2% se mostraram eficazes, sem diferenças entre os sistemas ou se as peças eram mantidas unidas ou desconectadas antes da limpeza. Os pacientes avaliados apresentaram diferenças tanto no aspecto clínico quanto no padrão microbiológico e resposta à sensibilidade antibiótica. Conclui-se que a retenção por implantes é confiável e segura para a reconstrução protética craniofacial, porém higiene cuidadosa, cuidados posteriores e manutenções regulares são importantes para minimizar complicações. A clorexidina tem valor se usada como antisséptico tópico local, tanto em análises laboratoriais quanto clínicas, mas fatores de retenção como a presença de componentes transcutâneos podem reduzir a resposta ao antisséptico. / Facial defects may be generated by traumas, congenital anomalies and resections for treating pathologies. Whatever the cause, the loss of facial substance promotes functional and aesthetic losses, psychological impact and restricts social relationships. The rehabilitation of facial defects can be realized by surgery and/or by prostheses. Facial prostheses supported by extraoral implants are treatment options that allow good symmetry and similarity of color and anatomical details, being an alternative option after surgical treatment failure. The aims of this study are to evaluate survival rates and complications related to implant surgery with auricular prostheses rehabilitation purpose, through a literature review; analyze microbiological differences in prosthesis implant-abutment interface, considering the effects of cleaning, and describe the microbiological profile of two patients rehabilitated by auricular prostheses supported by implants. A literature review, involving controlled vocabulary and free terms, was conducted in the PubMed database. Then an in vitro study was conducted on different platforms and connections to establish microbiological differences of cleaning plataforms with chlorhexidine solution. Finally, the colonization differences and the management of and two cases rehabilitated with auricular prostheses, which had soft tissue reactions, were described. Loss of implants and reactions of skin/mucosa were the most cited complications. Survival rates ranged around 90-100%, depending on factors such as the installation site of the implant and previous radiation. In the laboratory, hygienic procedures with alcoholic solution of chlorhexidine at 2% have been proven effective, with no differences between the systems evaluated or whether the parts were held together or disconnected before cleaning. The patients evaluated showed differences in the clinical aspects, microbiological profile and antibiotic sensitivity. It was concluded that the retention by implants is reliable and safe for craniofacial prosthetic reconstruction, but careful hygiene, aftercare and regular maintenance are important to minimize complications. Chlorhexidine has a value if used as a topic antiseptic, both in laboratory and clinical analysis, but retention factors; such transcutaneous components can reduce the response to the antiseptic.
|
2 |
Avaliação do desajuste e do destorque em pilares protéticos com conexão tipo hexágono externo e internoKano, Stefania Carvalho 21 February 2005 (has links)
Objetivou-se com este trabalho foi avaliar o desajuste marginal e o efeito da aplicação de carga cíclica no destorque dos parafusos de retenção de pilares protéticos usinados, sobrefundidos e fundidos com conexão tipo hexágono externo (HE) e interno (HI). Foram avaliados 12 pilares protéticos para cada grupo com HE:(A1) usinados em titânio; (A2) com cinta metálica em paládio-prata, sobrefundidos com paládio-prata; (A3) plásticos fundidos em NiCr e (A4) plásticos fundidos em CoCr; e 12 pilares protéticos para cada grupo com HI: (B1) usinados em titânio e (B2) com cinta metálica em paládio-prata, sobrefundidos com paládio-prata. Foram realizadas análises de desajuste marginal (profundidade de fenda, desajuste vertical e horizontal) e de desajuste rotacional na interface implante/pilar protético. Os valores de destorque foram registrados antes e depois da aplicação de cargas cíclicas. As médias de cada grupo, para cada análise, foram calculadas e comparadas com ANOVA, Student-Newman Keuls (p<0,05). Os resultados obtidos foram: profundidade de fenda (µm): (A1) 54,1±127,75, (A2) 49,4±36,56, (A3) 21,2±21,36, (A4) 33,1±23,81, (B1) 8,4±13,74 e (B2) 34,9±20,49; desajuste horizontal (µm): (A1) 89,1 ± 14,15, (A2) 39,2 ± 16,87, (A3) 13,5 ± 9,48, (A4) 23,0 ± 21,42, (B1) 10,9 ± 5,68 e (B2) 18,2 ± 10,31; desajuste vertical (µm): (A1) 5,6 ± 6,46, (A2) 11,1 ± 8,22, (A3) 8,0 ± 9,35, (A4) 6,9 ± 3,78, (B1) 2,1 ± 3,21 e (B2) 12,1 ± 4,75; desajuste rotacional (em graus): (A1) 1,2 ± 0,57, (A2) 1,8 ± 1,31, (A3) 2,0 ± 0,73, (A4) 2,8 ± 1,14, (B1) 2,8 ± 1,08 e (B2) 2,0 ± 1,03; destorque inicial (%): (A1) 92,3 ±3,0, (A2) 81,6 ± 5,0, (A3) 86,4 ± 4,6, (A4) 84,0 ± 7,7, (B1) 88,8 ± 6,8 e (B2) 84,9 ± 2,4 e destorque final (%): (A1) 41,1 ± 19,3, (A2) 19,8 ± 13,0, (A3) 27,9 ± 6,5, (A4) 37,5 ± 16,2, (B1) 17,1 ± 16,2 e (B2) 23,3 ± 10,9. Para as análises de desajuste marginal, os resultados demonstraram que as diferenças entre pilares usinados, sobrefundidos e fundidos foram variáveis. Todos os grupos apresentaram desajuste rotacional inferior a 5º, indicando adequada estabilidade das conexões estudadas. Para a conexão tipo hexágono externo avaliada neste estudo, os pilares usinados apresentaram maior destorque inicial, entretanto, o destorque final foi igual para os pilares usinados e fundidos. O destorque final dos pilares usinados com hexágono externo avaliados neste estudo foi maior que dos pilares usinados com hexágono interno. / Marginal misfit and the effect of cyclic loading on screw joint stability were analyzed for machined, cast-on and cast abutments with external and internal connection. Twelve samples from each abutment type for external hexagonal implants were included: (A1) machined titanium; (A2) metal premachined with plastic sleeve cast-on with palladium alloy; (A3) plastic abutment cast with NiCr alloy, and (A4) plastic abutment cast with CoCr alloy. And 24 samples for internal hexagonal implants: (B1) machined titanium, and (B2) metal premachined with plastic sleeve cast-on with palladium. Horizontal depth gap, vertical and horizontal gap and rotational misfit were analyzed at the implant/abutment interface. Detorque values were obtained for each group before and after cyclic loading. Mean values for each group for each analysis were evaluated for difference using ANOVA and Student-Newman Keuls. Results were: horizontal depth gap (A1) 54.1±127.75, (A2) 49.4±36.56, (A3) 21.2±21.36, (A4) 33.1±23.81, (B1) 8.4±13.74 and (B2) 34.9±20.49; horizontal gap: (A1) 89.1 ± 14.15, (A2) 39.2 ± 16.87, (A3) 13.5 ± 9.48, (A4) 23.0 ± 21.42, (B1) 10.9 ± 5.68 and (B2) 18.2 ± 10.31; vertical gap: (A1) 5.6 ± 6.46, (A2) 11.1 ± 8.22, (A3) 8.0 ± 9.35, (A4) 6.9 ± 3.78, (B1) 2.1 ± 3.21 and (B2) 12.1 ± 4.75; rotational misfit: (A1) 1.2 ± 0.57, (A2) 1.8 ± 1.31, (A3) 2.0 ± 0.73, (A4) 2.8 ± 1.14, (B1) 2.8 ± 1.08 and (B2) 2.0 ± 1.03; initial detorque: (A1) 92.3 ±3.0, (A2) 81.6 ± 5.0, (A3) 86.4 ± 4.6, (A4) 84.0 ± 7.7, (B1) 88.8 ± 6.8 and (B2) 84.9 ± 2.4 and final detorque: (A1) 41.1 ± 19.3, (A2) 19.8 ± 13.0, (A3) 27.9 ± 6.5, (A4) 37.5 ± 16.2, (B1) 17.1 ± 16.2 and (B2) 23.3 ± 10.9. Marginal gap analysis showed no major differences among all groups. All groups presented less than 5 degrees of rotational misfit, indicating good screw joint stability. External hexagonal machined abutments presented higher initial detorque than all groups, however, no differences were found for final detorque values when compared to cast-on and cast abutments. External hexagonal cast abutments presented higher final detorque when compared to cast-on abutments. External hexagonal machined abutments also presented higher final detorque values when compared to internal hexagonal machined abutments.
|
3 |
Avaliação do desajuste e do destorque em pilares protéticos com conexão tipo hexágono externo e internoStefania Carvalho Kano 21 February 2005 (has links)
Objetivou-se com este trabalho foi avaliar o desajuste marginal e o efeito da aplicação de carga cíclica no destorque dos parafusos de retenção de pilares protéticos usinados, sobrefundidos e fundidos com conexão tipo hexágono externo (HE) e interno (HI). Foram avaliados 12 pilares protéticos para cada grupo com HE:(A1) usinados em titânio; (A2) com cinta metálica em paládio-prata, sobrefundidos com paládio-prata; (A3) plásticos fundidos em NiCr e (A4) plásticos fundidos em CoCr; e 12 pilares protéticos para cada grupo com HI: (B1) usinados em titânio e (B2) com cinta metálica em paládio-prata, sobrefundidos com paládio-prata. Foram realizadas análises de desajuste marginal (profundidade de fenda, desajuste vertical e horizontal) e de desajuste rotacional na interface implante/pilar protético. Os valores de destorque foram registrados antes e depois da aplicação de cargas cíclicas. As médias de cada grupo, para cada análise, foram calculadas e comparadas com ANOVA, Student-Newman Keuls (p<0,05). Os resultados obtidos foram: profundidade de fenda (µm): (A1) 54,1±127,75, (A2) 49,4±36,56, (A3) 21,2±21,36, (A4) 33,1±23,81, (B1) 8,4±13,74 e (B2) 34,9±20,49; desajuste horizontal (µm): (A1) 89,1 ± 14,15, (A2) 39,2 ± 16,87, (A3) 13,5 ± 9,48, (A4) 23,0 ± 21,42, (B1) 10,9 ± 5,68 e (B2) 18,2 ± 10,31; desajuste vertical (µm): (A1) 5,6 ± 6,46, (A2) 11,1 ± 8,22, (A3) 8,0 ± 9,35, (A4) 6,9 ± 3,78, (B1) 2,1 ± 3,21 e (B2) 12,1 ± 4,75; desajuste rotacional (em graus): (A1) 1,2 ± 0,57, (A2) 1,8 ± 1,31, (A3) 2,0 ± 0,73, (A4) 2,8 ± 1,14, (B1) 2,8 ± 1,08 e (B2) 2,0 ± 1,03; destorque inicial (%): (A1) 92,3 ±3,0, (A2) 81,6 ± 5,0, (A3) 86,4 ± 4,6, (A4) 84,0 ± 7,7, (B1) 88,8 ± 6,8 e (B2) 84,9 ± 2,4 e destorque final (%): (A1) 41,1 ± 19,3, (A2) 19,8 ± 13,0, (A3) 27,9 ± 6,5, (A4) 37,5 ± 16,2, (B1) 17,1 ± 16,2 e (B2) 23,3 ± 10,9. Para as análises de desajuste marginal, os resultados demonstraram que as diferenças entre pilares usinados, sobrefundidos e fundidos foram variáveis. Todos os grupos apresentaram desajuste rotacional inferior a 5º, indicando adequada estabilidade das conexões estudadas. Para a conexão tipo hexágono externo avaliada neste estudo, os pilares usinados apresentaram maior destorque inicial, entretanto, o destorque final foi igual para os pilares usinados e fundidos. O destorque final dos pilares usinados com hexágono externo avaliados neste estudo foi maior que dos pilares usinados com hexágono interno. / Marginal misfit and the effect of cyclic loading on screw joint stability were analyzed for machined, cast-on and cast abutments with external and internal connection. Twelve samples from each abutment type for external hexagonal implants were included: (A1) machined titanium; (A2) metal premachined with plastic sleeve cast-on with palladium alloy; (A3) plastic abutment cast with NiCr alloy, and (A4) plastic abutment cast with CoCr alloy. And 24 samples for internal hexagonal implants: (B1) machined titanium, and (B2) metal premachined with plastic sleeve cast-on with palladium. Horizontal depth gap, vertical and horizontal gap and rotational misfit were analyzed at the implant/abutment interface. Detorque values were obtained for each group before and after cyclic loading. Mean values for each group for each analysis were evaluated for difference using ANOVA and Student-Newman Keuls. Results were: horizontal depth gap (A1) 54.1±127.75, (A2) 49.4±36.56, (A3) 21.2±21.36, (A4) 33.1±23.81, (B1) 8.4±13.74 and (B2) 34.9±20.49; horizontal gap: (A1) 89.1 ± 14.15, (A2) 39.2 ± 16.87, (A3) 13.5 ± 9.48, (A4) 23.0 ± 21.42, (B1) 10.9 ± 5.68 and (B2) 18.2 ± 10.31; vertical gap: (A1) 5.6 ± 6.46, (A2) 11.1 ± 8.22, (A3) 8.0 ± 9.35, (A4) 6.9 ± 3.78, (B1) 2.1 ± 3.21 and (B2) 12.1 ± 4.75; rotational misfit: (A1) 1.2 ± 0.57, (A2) 1.8 ± 1.31, (A3) 2.0 ± 0.73, (A4) 2.8 ± 1.14, (B1) 2.8 ± 1.08 and (B2) 2.0 ± 1.03; initial detorque: (A1) 92.3 ±3.0, (A2) 81.6 ± 5.0, (A3) 86.4 ± 4.6, (A4) 84.0 ± 7.7, (B1) 88.8 ± 6.8 and (B2) 84.9 ± 2.4 and final detorque: (A1) 41.1 ± 19.3, (A2) 19.8 ± 13.0, (A3) 27.9 ± 6.5, (A4) 37.5 ± 16.2, (B1) 17.1 ± 16.2 and (B2) 23.3 ± 10.9. Marginal gap analysis showed no major differences among all groups. All groups presented less than 5 degrees of rotational misfit, indicating good screw joint stability. External hexagonal machined abutments presented higher initial detorque than all groups, however, no differences were found for final detorque values when compared to cast-on and cast abutments. External hexagonal cast abutments presented higher final detorque when compared to cast-on abutments. External hexagonal machined abutments also presented higher final detorque values when compared to internal hexagonal machined abutments.
|
4 |
Protese com encaixe de semi-precisãoMeneghel, Ataualpa Francisco Pacheco 03 August 2018 (has links)
Orientador: Krunislave Antonio Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T10:26:37Z (GMT). No. of bitstreams: 1
Meneghel_AtaualpaFranciscoPacheco_D.pdf: 1909368 bytes, checksum: ef9926c97acbeb1e5cb8439d56adf20d (MD5)
Previous issue date: 1971 / Resumo: Não informado / Abstract: Not informed / Doutorado / Protese Dental / Doutor em Ciências
|
5 |
Comparação entre dois metodos para o registro dos contatos oclusaisCabral, Claudio Wilson Lima Ferro 03 August 2018 (has links)
Orientador : Frederico Andrade e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T14:40:21Z (GMT). No. of bitstreams: 1
Cabral_ClaudioWilsonLimaFerro_M.pdf: 3085734 bytes, checksum: ad46f1bae9a606eea7f81afa3cdd1248 (MD5)
Previous issue date: 2003 / Mestrado
|
6 |
Reprodução dos dentes remanescentes nas proteses imediatas : (uma tecnica para contribuição ao seu estudo)Mazzonetto, Sergio Francisco, 1936- 20 July 2018 (has links)
Orientador: Krunislave Antonio Nobilo / Tese (doutorado) - Universidade de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T13:35:34Z (GMT). No. of bitstreams: 1
Mazzonetto_SergioFrancisco_D.pdf: 1140028 bytes, checksum: a9fde08ed472d8db9b6aead3f38b900d (MD5)
Previous issue date: 1967 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Protese Dental / Doutor em Ciências
|
7 |
Efeito protetor da vitima E(ɑ-TOCOFEROL) contra a atividade citotóxica do peróxido de hidrogenênio /Vargas, Fernanda da Silveira. January 2013 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Gelson Luis Adabo / Banca: Adriano Fonseca de Lima / Resumo: O clareamento dental de consultório, realizado com géis que apresentam elevada concentração de peróxido de hidrogênio (PH), pode causar danos intensos para as células da polpa dentária. Dentro deste contexto, a administração de agentes antioxidantes previamente ao clareamento dental, tem sido considerada uma terapia promissora, pois pode eliminar ou pelo menos minimizar os efeitos adversos deste procedimento clínico estético. Assim, o objetivo do presente estudo foi avaliar o possível efeito protetor da Vitamina E (alfa-Tocoferol / α-T) contra à ação citotóxica do PH sobre células odontoblastóides (MDPC-23). Para isto, células foram semeadas em placas de 96 wells durante 72 horas e então submetidas a diferentes tempos de pré-tratamento (1, 4, 8 e 24 horas) com variadas concentrações de α-T (1, 3, 5 e 10 mM). Após os períodos de pré-tratamento, as células foram expostas ou não ao PH (0,018%) durante 30 minutos. Nos grupos controle positivo e negativo, as células foram somente expostas a uma solução de PH (0,018%) ou meio de cultura, respectivamente. O metabolismo celular foi avaliado pelo teste de MTT. A absorbância foi transformada em porcentagem e analisada pelo Teste de Kruskal-Wallis, complementado por Mann-Whitney (α=0,05%). Todas as concentrações de α-T e tempos de pré-tratamento propostos neste estudo apresentaram proteção das células contra os efeitos citotóxicos do PH. Porém, os melhores resultados foram obtidos com as concentrações de 1 e 3 mM (126% e 97%, respectivamente) por 24 horas em relação a 41% de metabolismo celular do grupo controle positivo (p<0,05). Portanto, as células pré-tratadas com α-T por 24 horas, em concentrações baixas (1 e 3 mM), apresentaram os melhores resultados de viabilidade celular, ou seja, maior efeito protetor frente à agressão direta do PH / Abstract: The in-office tooth bleaching using gels with high concentrations of hydrogen peroxide (HP) may cause irreversible damage to pulp tissue. Therefore, the administration of antioxidazing agents previously to the tooth bleaching procedures has been considered as a promising therapy, mainly due the capacity of these agents to prevent, or at last reduce, the negative side-effects caused by toxic products used in this esthetic treatment. Therefore, the aim of the present in vitro study was to evaluate the protective activity of vitamin E (alfa-Tocoferol / α-T) against the toxic effects of HP applied to cultured odontoblast-like cells (MDPC-23). Cells were seeded in wells of 96-well plates for 72 hs and then pre-treated with different concentrations of α-T (1, 3, 5, and 10 mM) for variable periods (1, 4, 8, and 24 hs). Following, the cells were exposed to a HP solution (0,018%) for 30 min. In positive and negative control groups, the cells were exposed only to HP solution (0,018%) or culture medium, respectively. The cell metabolism was assessed by MTT assay and the absorbance numeric data, expressed as percentage values, were subjected to the statistical analysis of Kruskal-Wallis complemented by Mann-Whitney test (α=0.05%). All α-T concentrations and pre-treatments evaluated in this study showed cell protection against the cytotoxic effects of HP. However, considering the MDPC-23 cells in the negative control group as presenting 100% metabolism, it was observed that the most relevant data occurred when the cells were pre-treated with α-T at 1 and 3 mM (126% and 97% of cell metabolism, respectively) for 24hs compared to the positive control group (41%) (p<0.05). Based upon the methodology used in the present investigation, it can be concluded that low concentrations of α-T (1 and 3 mM) applied for 24 hs to the cultured odontoblast-like MDPC-23 cells provide the best protective effects against the cytotoxicity caused by hydrogen peroxide / Mestre
|
8 |
Dentaduras completas : alterações dimensionais de algumas medidas horizontais e verticaisPacheco, Fernando Antonio de Azevedo, 1936- 20 July 2018 (has links)
Orientador: Krunislave Antonio Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T17:11:37Z (GMT). No. of bitstreams: 1
Pacheco_FernandoAntoniodeAzevedo_D.pdf: 1244971 bytes, checksum: 3cb6ab8c68ceb8d092f75b76ed0d4078 (MD5)
Previous issue date: 1968 / Resumo: Não informado / Abstract: Not informed. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
9 |
Avaliação da estabilidade cromática da pintura de íris em próteses oculares polimerizadas por energia de microondas, variando a cor, a tinta e o método de secagem /Fernandes, Aline Úrsula Rocha. January 2004 (has links)
Orientador: Marcelo Coelho Goiato / Resumo: A íris artificial é a estrutura da prótese ocular responsável pela sua dissimulação e estética. O propósito do presente trabalho foi avaliar a alteração de cor de tintas utilizadas na pintura de íris em próteses oculares polimerizadas por energia de microondas, variando-se tinta, cor e método de secagem. Para o estudo, foram confeccionados cinco discos em resina termopolimerizável por microondas para cada tinta analisada: acrílica hidrossolúvel, automotiva à base de nitrocelulose, guache hidrossolúvel e a óleo, nas cores marrom e azul, para os métodos de secagem natural e por radiação infravermelha, perfazendo um total de 80 corpos-de-prova. Cada corpo-de-prova foi constituído por um disco de resina acrílica incolor e outro, de igual dimensão, de resina acrílica de coloração branca de esclera e, entre os dois discos, a pintura. Os corposde- prova foram submetidos a uma câmara de envelhecimento acelerado sob radiação ultravioleta, por 1008 horas. Para avaliar as variações de cor foi usado um espectrofotômetro de reflexão. Os resultados foram analisados estatisticamente por Análise de Variância e teste de Tukey a 5% de significância. Todas as tintas sofreram alteração cromática. A tinta a óleo apresentou a maior resistência frente ao envelhecimento acelerado, independente da cor e do método de secagem. / Abstract: The artificial iris is the structure of the ocular prosthesis responsible for its dissimulation and aesthetics. The objective of the present study was to evaluate the color stability of paint used for iris painting for ocular prosthesis polymerized with microwaves, varying painting, color and drying method. For the study, 80 discs in heat-curing for microwaves acrylic resin were made, five discs for each paint analyzed: acrylic water-soluble paints, automotive nitrocellulose paints, watercolor paints and oil paints, for the colors brown and blue, for both natural and infrared drying methods. Each specimen was constituted of one disc in colorless acrylic resin and another colored with a basic sclera pigment. The painting was accomplished in one of the surfaces of one of the discs. The specimens were submitted to an artificial aging chamber under ultraviolet light, during 1008 hours. To evaluate color changes a reflective spectrophotometer was used. The data were statistically analyzed by Variance Analysis and Tukey's test. All paints suffered color alteration. The oil paints presented the highest resistance to artificial aging regardless the pigment and the drying method. / Mestre
|
10 |
Comparação da força de ruptura de alimentos teste entre três diferentes esquemas oclusais para próteses totais /Medeiros, Flávia Regina Machado de. January 2013 (has links)
Orientador: Sergio Sualdini Nogueira / Banca: Juliana Alvares Duarte Bonini Campos / Banca: João Neudenir Arioli Filho / Banca: João Gustavo Rabelo Ribeiro / Banca: Luís Eduardo Butignon / Resumo: Frente ao reconhecimento de que os movimentos mandibulares são influenciados pela oclusão e, que se pode assumir que o mais efetivo padrão de mastigação para um indivíduo específico irá depender da natureza de sua oclusão, observa-se não existir na literatura correlações concretas entre tipos de oclusões no que diz respeito à função mastigatória. Neste contexto, esse trabalho tem o objetivo de realizar um estudo comparativo laboratorial da força necessária para que ocorra a ruptura de alimentos teste entre os três tipos de esquemas oclusais para próteses totais: Oclusão Convencional, Oclusão Lingualizada e Oclusão Monoplano. Para tanto foi utilizada uma máquina de ensaio universal EMIC a qual se realizou força de compressão sobre um verticulador dotado de dispositivos com os esquemas oclusais em estudo, simulando a força de mordida. A amostra foi formada por três grupos, cada um representando um tipo de oclusão a ser estudada e em cada grupo 5 alimentos teste avaliados, sendo 4 alimentos teste naturais: amêndoa, amendoim, cenoura e café e um alimento teste artificial representado pela silicone (optosil). As oclusões formadas por dentes anatômicos (convencional e lingualizada) tiveram maior desempenho, precisando assim de uma força de mordida menor para realizar a ruptura do alimento teste em relação a oclusão com dentes não anatômicos (monoplano). Houve diferença estatística na maioria das comparações entre os esquemas oclusais estudados em relação à força necessária para causar ruptura dos alimentos-teste, mas nenhum esquema em particular foi melhor do que os outros para todos os tipos de alimento teste. / Abstract: Three popular occlusal schemes for complete dentures are: conventional balanced occlusion; lingualized balanced occlusion and monoplane occlusion. It was observed that there is few scientific data that allow effective correlation related to the masticatory function between the cited occlusion schemes. In this context, the purpose of this study is to describe a laboratory comparative study of the occlusal force necessary to cause rupture in certain test foods between the conventional, lingualized and monoplane occlusal schemes used to construct complete dentures. The occlusal force was generated by an EMIC universal tests machine compressing the upper side of an articulator where occlusal patterns resembles representing the studied occlusal schemes were fixed. Five different test foods were used in this research, four out five were natural foods (almond, peanut, coffee and carrot) and one was artificial (silicone). It was concluded that: 1. In most comparisons, there were significant statistical differences in the forces applied by the studied occlusal schemes to cause rupture of the test foods, but there was no particular scheme better than the others; 2. In most comparisons the monoplane scheme of occlusion required higher forces to cause the rupture of the test foods. / Doutor
|
Page generated in 0.0467 seconds