Spelling suggestions: "subject:"prótese dentária"" "subject:"próteses dentária""
111 |
Discrepâncias de assentamento ocorrido em coroas totais metálicas, com e sem alívio interno, variando-se os términos cervicais e os agentes cimentantes /Figueiredo, Aldari Raimundo January 1997 (has links)
Orientador: Marco Antonio Bottino / Banca: Pedro Tortamano Neto / Banca: Orlando Magalhães Filho / Banca: José Eduardo Junho de Araujo / Banca: Ruy Fonseca Brunetti / Resumo: Foi feita uma análise das discrepâncias de assentamento ocorridas na cimentação de coroas totais metálicas aliviadas ou não, internamente, sobre preparos com término cervical em chanfro; linha zero ou lâmina de faca; plano inclinado em 135°; ombro reto ou degrau em 90° e ombro reto ou degrau em 90°, associado a um bisel em 45°. Empregaram-se quatro tipos de cimentos, sendo três classificados como temporários à base de óxido de zinco e eugenol (Temp Bond e Provy) e outro sem eugenol (Temp Bond NE); e um quarto indicado para cimentações definitivas, cimento de Fosfato de Zinco. Idealizou-se modelos-padrão usinados em aço inoxidável, com características de um preparo para coroa total metálica em um primeiro molar inferior variando-se os términos cervicais conforme estabelecido. Foram obtidas cápsulas metálicas usinadas em aço inoxidável e perfeitamente adaptadas aos modelos-padrão com os términos cervicais correspondentes, nas condições de estarem aliviadas internamente ou não. Empregou-se uma técnica de cimentação padronizada para assentamento destas cápsulas metálicas nos modelos-padrão respectivos. Através de metodologia original promoveu-se a mensuração da discrepância de assentamento nos corpos-de-prova, com o aparelho Metroscópio Horizontal. Concluiu-se que: a) o alívio executado nas superfícies internas das coroas diminui de forma estatisticamente significante a discrepância marginal após a cimentação, independentemente do tipo de cimento empregado e da forma do término cervical adotada; b) o término cervical do preparo no modelo-padrão tipo Lâmina de Faca foi o que apresentou menor discrepância, independente do cimento empregado, seguido pelo Plano Inclinado, Chanfro, Ombro Biselado e Ombro Reto; c) os términos cervicais em Chanfro, Plano Inclinado e Lâmina de Faca, quando analisadas as amostras dos corpos-de-prova com alívio, .... / Abstract: Seating discrepancies during cementation of complete metal crowns internally relieved or not with various finishing lines and cementing agents. This study evaluated the discrepancies during cementation of complete metal crowns either relieved or not on preparation with various margin designs: chamfer, knife edge, 135 degree shoulder, 90 degree shoulder, 90 degree shoulder with 45 degree bevel. Four types of cements, three temporary and one definitive were used: 1- zinc oxide and eugenol temporary cement (Temp Bond); 2- zinc oxide and eugenol temporary cement (Provy); 3- no eugenol temporary cement (Temp Bond NE) and 4- zinc phosphate cement (S.S.White). Machined stainless dies were fabricated to resemble complete crown preparations for a lower first molar with various finishing lines. Machined stainless steel copings, either internally relieved or not were also fabricated to fit the metal dies. A controlled technique was developed to assess seating discrepancies under the horizontal metroscope. Results showed: a) the internally relieved crowns showed after cementation statistically significant reduction of marginal discrepancies regardless of cement type or margin desing; b) knife edge finishing lines showed least dicrepancies regardless of cement type followed by the 135 degree shoulder, chamfer, bevelled 90 degree shoulder and 90 degree shoulder; c) internally relieved copings with chamfer, 135 degree shoulder and knife edge finishing lines showed no statiscally significant marginal discrepancies. This indicates that any of them yields favorable results; d) regarding cements, the least marginal discrepancies were found with Temp Bond NE followed by Temp Bond, Provy and finally by the Zinc Phosphate Cement (S.S.White) / Doutor
|
112 |
Avaliação da força mastigatória e da atividade eletromiográfica dos músculos masseter e temporal em função de diferentes tratamentos reabilitadores /Gomes, Isabela Silva. January 2011 (has links)
Resumo: A função mastigatória é um dos mais complexos mecanismos neuropsicológicos no desempenho motor humano, dependendo de vários fatores como força de mordida, coordenação dos músculos, morfologia e número de dentes em oclusão. O objetivo desse trabalho é quantificar a força mastigatória máxima e analisar eletromiograficamente os músculos elevadores mandibulares de pacientes dentados totais (n=52) e reabilitados com prótese total (PT) (n=28) e prótese parcial removível (PPR) (n=27), a fim de verificar a influência de diferentes tratamentos reabilitadores na força mastigatória e atividade dos músculos masseter e temporal. A coleta dos dados de força de mordida (FM) e atividade eletromiográfica (EMG) foi realizada em triplicata em repouso e em contração isométrica através de um transdutor de força de mordida (desenvolvido pelos autores) e um eletromiógrafo EMG-800c de oito canais (EMG System do Brasil Ltda). Outras variáveis como gênero, idade, peso, estresse, prática de atividade física, lado preferencial da mastigação, formato facial e consistência da alimentação também foram levantadas e comparadas às variáveis FM e EMG em função dos grupos experimentais. Os valores de força de mordida (em Kgf) e os sinais eletromiográficos (em voltagem RMS) dos músculos masseter e temporal direito e esquerdo foram submetidos à estatística descritiva e comparados em função dos grupos experimentais por meio do teste estatístico de Análise de Variância 1 fator (ANOVA) e ao teste Tukey com nível de significância de 5%. Com relação à FM, o grupo controle (51,49 ± 16,24)A apresentou média estatisticamente superior (p=0,00<0,05) ao grupo PPR(28,45 ± 15,43)B e PT (13,11 ± 7,69)C . Com relação à EMG, em repouso... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The chewing is one of the most complex neuropsychological mechanisms in human motor performance, depending on various factors such as bite force, muscle coordination, morphology and number of teeth in occlusion. The aim of this study is to quantify the maximum bite force and analysis electromyographic of the jaw elevators muscles of dentate patients (n = 52) and rehabilitated with complete denture (CD) (n = 28) and removable partial dentures (RPD) (n = 27) in order to check the influence of different rehabilitation treatments in bite force and activity of the masseter and temporal. Data collection of bite force (BF) and electromyographic activity (EMG) was performed in triplicate at rest and during isometric contraction with a bite force transducer (developed by the authors) and an electromyograph EMG-800c eight-channel (EMG System do Brazil Ltda.) Other variations such as gender, age, weight, stress, physical activity, preferred side of chewing, facial shape and consistency of supply were also raised compared to variables BF and EMG as a function of the experimental groups. The values of bite force (kgf) and the electromyographic signals (RMS voltage) of the masseter and temporal right and left were subjected to descriptive statistics and compared on the basis of the experimental groups using the statistical test of a factor analysis of variance (ANOVA) and Tukey's test at a significance level of 5%. With respect to BF, the control group (51.49 ± 16.24) had statistically significant higher (p = 0.00 <0.05)A than PPR group (28.45 ± 15.43)B and PT (13 , 11 ± 7.69)C. Regarding the EMG at rest showed no statistical difference between any of the muscles (p> 0.05). In isometric contraction, however, the control group... (Complete abstract click electronic access below) / Orientador: Clovis Pagani / Coorientador: José Benedito Oliveira Amorim / Banca: Eduardo Galera da Silva / Banca: Rubens Côrte Real de Carvalho / Mestre
|
113 |
Avaliação mecânica e microbiológica de resinas acrílicas reforçadas com partículas de sílica revestidas com prata /Sacorague, Sâmia Carolina Mota Cacalcanti. January 2016 (has links)
Orientador: Tarcisio José de Arruda Paes-Junior / Co-orientador: Fernando Henrique Cristovan / Banca: Alexandre Luiz Souto Borges / Banca: Regina Tamaki / Banca: Marina Amaral / Banca: Lafayette Nogueira Junior / Resumo: O objetivo desta pesquisa foi sintetizar e caracterizar partículas de sílica recobertas com nanopartículas de prata, e avaliar a influência destas quando incorporadas à resina acrílica termicamente ativada e reembasador rígido, em suas características mecânicas e microbiológicas. Uma solução de sílica foi sintetizada pelo método de hidrólise controlada do tetraetilortosilicato (TEOS) em meio alcoólico. Foi adicionada a essa uma solução de nitrato de prata, em duas molaridades (10 mmols e 30 mmols) formando partículas do tipo núcleo-casca. Após centrifugação e secagem, cada pó obtido foi adicionado em duas concentrações: 0.5% e 2%, às resinas analisadas. Foram confeccionadas barras retangulares (n=9) de 30 x 10x 3mm para realização do teste de resistência a flexão de três pontos, rugosidade e ângulo de contato; e 120 amostras em forma de disco (2 mmx10 mm) para análise microbiológica. Como grupo controle teve-se amostras sem nanopartículas. As nanopartículas foram analisadas em microscopia eletrônica de varredura com microanalisador por energia dispersiva de raios-X integrado (EDS), Difratômetro de Raios-X e microscopia eletrônica de transmissão. Uma suspensão de Candida albicans foi utilizada para análise de aderência fúngica, halo de inibição e concentração inibitória mínima. As fotomicrografias mostraram que as nanopartículas de 10 mmols apresentam uma distribuição mais homogênea e menor agregação das nanopartículas de prata na superfície da sílica do que as de 30 mmols. Os resultados indicaram que a resistência a flexão foi afetada negativamente, em ambos materiais, com a adição de 2% de partículas, independente da molaridade. A adição das partículas não alterou a molhabilidade da superfície dos materiais, nem a rugosidade, exceto do grupo de reembasador com partículas de 10mmols, em ambas concentrações. As partículas não apresentaram ação antifúngica para os.... / Abstract: This research aimed to synthesize, characterize, and evaluate the influence of the addition of silica-silver core/shell particles in mechanical and antifungal characteristics of thermally active acrylic resins or hard reliner . Silica solution was produced by controlled hydrolysis method of tetraethylorthosilicate (TEOS) in an alcoholic. It was added a silver nitrate solution in two molarities, 10 and 30 milimols, forming core-shell particles. After centrifugation and drying, each obtained powder was added in two concentrations 0.5% and 2% in the resins analyzed. Rectangular samples (n=9) with 30 x10 x3 mm were made to three point bend test), roughness and contact angle, and 120 samples in disc (2 mmx10 mm) for microbiological analysis Samples without particles were used as control. The nanoparticles were analyzed by scanning electron microscopy with dispersive energy microanalyzer integrated X-rays (EDS), X-ray diffractometer and transmission electron microscopy. Candida albicans suspension was used to adhesion test, inhibition zone and minimum inhibitory concentration. Photomicrograph showed that nanoparticles with 10 milimols show a distribution more uniform and less aggregation of silver nanoparticles on the silica surface than 30 millimols. The Three point bend test results showed that the flexural strength was negatively affected in both materials, with the addition of 2% particles, in both molarity. The addition of the nanoparticles did not change the surface wettability or roughness of the materials, except for except the reliner group with 10mmols, in both concentrations. The nanoparticles showed no antifungal action for the materials tested at any concentration, neither was zone innibition. However, the solution presented minimal inhibitory concentration to 2.000 ppm. We conclude that low concentrations nanoparticles do not affect the mechanical characteristics and surface of ... / Doutor
|
114 |
Influência do tratamento de superfície e do tipo de cimento na retenção de coroas YTZP /Rippe, Marília Pivetta. January 2013 (has links)
Orientador: Marco Antonio Bottino / Co-orientador: Luiz Felipe Valandro / Banca: Paulo Francisco César / Banca: Estevam Augusto Bonfante / Banca: Renata Marques de Melo Marinho / Banca: Alexandre Luiz Souto Borges / Resumo: Comparar a retenção de coroas de zircônia YTZP em função do protocolo de cimentação. Foram preparados para coroa total 108 molares extraídos (n = 12). Pinos de fibra de vidro foram cimentados e núcleos de resina composta construídos. Infraestruturas de zircônia YTZP foram fresadas e 72 espécimes foram alocados em 6 grupos conforme os fatores: cimento - Multilink (Mult) e Relyx ARC (Rel); e tratamento de superfície da zircônia - álcool (controle) (C), silicatização (S) e vitrificação (V). Os outros 36 espécimes foram divididos em 3 grupos cimentados com Relyx Luting (Ion), Relyx U100 (Self) e fosfato de zinco (Zinc) sem tratamento da zircônia. Todos os espécimes foram termociclados (5 - 55 ºC, 6000 ciclos) e os dados do teste de tração foram analisados pelo teste de Kruskal Wallis e Dunn. Os valores da mediana e distância interquartil foram os seguintes: MultC: 20,0 (± 5,5); MultS: 28,5 (± 22,0); MultV: 32,5 (± 28,5); RelC: 21,5 (± 8,5); RelS: 22,0 (± 10,0); RelV: 24,0 (± 7,3); Ion: 5,1 (± 6,4); Self: 3,5 (± 5,2); Zinc: 7,7 (± 14,2). O tipo de cimento resinoso (a base de Bis-GMA e HEMA) não afetaram os valores de retenção das coroas. O tratamento de superfície da cerâmica vitrificação somente foi capaz de melhorar os valores de retenção para o cimento a base de HEMA. Para superfícies cerâmicas não tratadas, os cimentos resinosos mostraram significantemente maiores valores de retenção do que aqueles obtidos para os cimentos auto-adesivo, de inonômero de vidro e de fosfato de zinco / Abstract: To compare the retention of YTZP zirconia crowns cemented to different cementation protocols. 108 extracted molars were prepared for full crown (n = 12); and the core was reconstructed with glass fiber post and composite resin core. YTZP zirconia copings were milled and 72 specimens were divided into 6 groups according to the factors: cements- Multilink (Mult) and Relyx ARC (Rel); and zirconia surface treatments- alcohol (control) (C), silica coating (S) and vitrification (V). The remaining 36 specimens were divided into 3 groups cemented with Relyx Luting (Ion), Relyx U100 (Self) and Zinc phosphate (Zinc) on untreated zirconia. The specimens were thermally cycled (5 - 55 °C, 6000 cycles) and data from the tensile test were analyzed by Kruskal Wallis and Dunn test. The median and interquartil range were: MultC: 20.0 (± 5.5); MultS: 28.5 (± 22.0); MultV: 32.5 (± 28.5); RelC: 21.5 (± 8.5); RelS: 22.0 (± 10.0); RelV: 24.0 (± 7.3); Ion: 5.1 (± 6.4); Self: 3.5 (± 5.2); Zinc: 7.7 (± 14.2). The type of resin cement (BIS-GMA- or HEMA- based) did not affect the crown retention values. The treatment involving vitrification of the cementation surface was only capable to improve the retention force for the HEMA based-cement. For untreated intaglio surfaces of YTZP crowns, resin cements showed significantly higher retention than those obtained for self-adhesive, glass ionomer and zinc phosphate cements / Doutor
|
115 |
Perda óssea marginal em implantes distais em próteses fixas implantossuportadas: desenvolvimento metodológico para estudo prospectivo radiográficoCamargo, Bernardo Alievi January 2014 (has links)
Made available in DSpace on 2014-06-28T02:02:15Z (GMT). No. of bitstreams: 1
000458942-Texto+Completo-0.pdf: 1319347 bytes, checksum: 53009a393ff35022421155e36d99405d (MD5)
Previous issue date: 2014 / Previous biomechanical studies show a great stress concentration at the distal region of implants adjacent to the cantilever in fixed implant-supported complete dentures (FISCD). Thus, it is necessary to evaluate the marginal bone levels in this region by means of intraoral radiographs. The objectives of this study were: 1) to develop a specific methodological approach for the radiographic evaluation of marginal bone loss (MBL) around the most distal implants adjacent to prosthetic cantilever in FISCD, 2) to investigate possible correlation between MBL, cantilever extension and mesio-distal inclination of the distal implants.Seven patients with 10 FICSD (n=20 implants) were accompanied during one year at the clinics of Faculty of Dentistry of PUCRS. Measurements of the cantilever extension of the metallic infrastructures were carried out during the prosthetic rehabilitation. The mesio-distal inclinations of the implants relative to the occlusal plane were defined through the cone beam computer tomography (CBCT). Intra-oral digital radiographs were obtained by customized positioning devices following delivery of the prostheses (baseline) and one year after the delivery. Cantilever extension, inclination and MBL of the distal implants were analyzed descriptively and inferentially: the correlation between MBL, cantilever extension and inclination of the implants were evaluated by Spearman‟s correlation coefficient with significance level of 5%.The mean values and their variability were; cantilever extension 9,80± 3,69 mm, distal inclination 2,50 (1,00; 10,50) degrees, mesial inclination -3,00(-5,00; -1,00) degrees, mesial MBL -0,08 (-0,28; 0,05) mm and distal MBL -0,04(-0,35; 0,09) mm. No statistical correlation was detected neither between MBL and cantilever extension nor between MBL and inclination of the distal implants. The proposed radiographic and methodological technique used in this study was reliable and reproducible. The findings of MBL after 1 year of follow-up were in accordance with the literature. / Estudos biomecânicos anteriores mostram que há uma maior concentração de forças na região distal dos implantes adjacentes ao cantilever protético em Próteses Totais Fixas Implantossuportadas (PTFIs), o que leva à necessidade de avaliação óssea periimplantar nessa região com radiografias intra-orais. Os objetivos deste trabalho foram o desenvolvimento de uma metodologia específica para avaliar radiograficamente a perda óssea linear em implantes mais distais, adjacentes ao cantilever protético em PTFIs e investigar sua possível correlação com extensão de cantilever e inclinação mésio-distal do implante.Foram acompanhados sete pacientes com 10 PTFIs (N=20 implantes) durante um ano, nas clínicas da Faculdade de Odontologia da PUCRS. A medição da extensão de cantilever protético na infraestrutura metálica foi realizada durante o tratamento. A inclinação mésio-distal dos implantes foi adquirida através de Tomografia computadorizada Cone Beam (CBCT) considerando o plano oclusal como referência. Foram realizadas radiografias intra-orais digitais, utilizando posicionadores customizados, após a entrega da prótese (baseline) e no acompanhamento de um ano. Extensão de cantilever, inclinação dos implantes e perda óssea foram analisados de forma descritiva e inferencial; a correlação entre perda óssea, extensão de cantilever e inclinação do implante foi efetuada com coeficiente de correlação de Spearman ao nível de significância de 5%.Os valores médios e sua variabilidade foram: extensão de cantilever 9,80± 3,69 mm, Inclinação Distal 2,50 (1,00; 10,50) graus, Inclinação Mesial -3,00 (-5,00; -1,00) graus e perda óssea M -0,08 (-0,28; 0,05) mm e perda óssea D -0,04 (-0,35; 0,09) mm. Não houve correlação estatística nem entre perda óssea marginal e extensão de cantilever protético nem entre perda óssea marginal inclinação dos implantes mais distais. Este trabalho demonstrou que a técnica de obtenção e análise das imagens radiográficas é confiável e reprodutível. Os achados de perda óssea em um ano estão de acordo com a literatura.
|
116 |
Influência da inclinação do implante distal e da extensão do cantilever na remodelação óssea periimplantar em próteses totais fixas: um estudo metodológico em tomografias computadorizadasDrummond, Luis Gustavo Rabello January 2014 (has links)
Made available in DSpace on 2014-07-12T02:02:11Z (GMT). No. of bitstreams: 1
000459186-Texto+Completo-0.pdf: 2996537 bytes, checksum: 329a4372d6198e24dbad12bffd381c67 (MD5)
Previous issue date: 2014 / Studies have been shown that for the treatment of the edentulous arches with Branemark protocol the inclination of the most posterior implants with distal cantilever extensions does not appear to have harmful effects on the bone structure. The objectives of this study were; 1) to develop a methodological approach for the evaluation of implant inclination and periimpllant bone remodeling (PBR) through the cone beam computer tomography (CBCT), 2) to investigate the influence of the implant inclination and cantilever extension on the PBR of most distal implants adjacent to prosthetic cantilever in fixed implant-supported complete dentures (FISCD). Twenty distal implants of 10 FISCD were evaluated from 7 patients treated at the clinics of the Faculty of Dentistry of PUCRS.To measure the PBR and inclination of the implants, CBCT scans at the prosthetic delivery phase and 1 year after delivery were used. With the Kodak CS 3D software the central region of the implant was determined and reference lines were traced on coronal and sagittal planes, on the center of the implant and perpendicular to this central line at the apex of the implant in order to measure the periimplant bone level (PBL). To evaluate the mesio-distal and vestibulo-lingual/palatinal implant inclination a reference line was traced on the occlusal plane and the angle between the central line of the implant was measured. The data of mesial, distal, vestibular and lingual/palatinal PBLs were collected in two moments to evaluate PBR in 1 year.The results show that, inclination of the implants adjacent to cantilever presented variations in mesio-distal and vestibulo-lingual/palatinal directions relative to occlusal plane. In general, bone loss occurred on mesial, distal, vestibular and lingual/palatinal faces of the distal implants. Higher bone loss values were obtained on distal and vestibular faces. A direct moderate/strong correlation was detected between cantilever extension and distal PBR in maxilla. This study has demonstrated that, the proposed methodological technique and was reliable and reproducible to evaluate PBR in mesio-distal and vestibulo-lingual/palatinal dimensions. / Estudos têm mostrado que para o tratamento de rebordo ósseo desdentado, através do tratamento tipo protocolo, a inclinação dos implantes mais posteriores com o uso de cantilever protético parece não ter efeitos prejudiciais à estrutura óssea. Assim, os objetivos deste estudo foram: 1) desenvolver uma metodologia para avaliar a inclinação dos implantes distais e avaliar a remodelação óssea periimplantar com o auxílio de tomografia computadorizada cone beam (CBCT); e 2) testar a influência da inclinação do implante mais distal e da extensão do cantilever protético sobre a remodelação óssea periimplantar. Foram avaliados 20 implantes distais de 10 Próteses Totais Fixas Implantossuportadas (PTFIs) em 7 pacientes atendidos na Faculdade de Odontologia da PUCRS.Para as mensurações de remodelação óssea de inclinação dos implantes foram utilizadas aquisições através de CBCT´s no momento da instalação da prótese e após um ano. Com auxílio de ferramentas do software CS 3D da Kodak, a região mais central do implante foi determinada para que linhas de referência pudessem ser traçadas no plano coronal e sagital, na região central e perpendicular a esta no ápice do implante para mensuração do nível ósseo periimplantar. Para avaliar a inclinação dos implantes no sentido mésio-distal e vestíbulo-lingual/palatino foi traçada uma linha no plano oclusal, sendo mensurada a inclinação com a linha central do implante. Os dados do nível ósseo mesial, distal, vestibular e palatino/lingual foram coletados em dois momentos para avaliar a remodelação em um ano.Os resultados mostraram que a inclinação do implante adjacente ao cantilever apresentou variações nos sentidos vestíbulo-lingual e mésio-distal, em relação ao plano oclusal. Em média houve perda óssea nas faces mesial, distal, vestibular e lingual dos implantes adjacentes ao cantilever, sendo que os maiores valores ocorreram nas faces distal e vestibular. Houve correlação direta moderada/forte entre a extensão do cantilever da PTFI e a remodelação óssea distal em maxila. Este trabalho demonstrou que a técnica de obtenção e análise das imagens tomográficas é confiável e reprodutível para avaliar a perda óssea periimplantar nas faces mesial, distal, vestibular e lingual/palatina, bem como para avaliar as inclinações mésio-distal e vestíbulo-lingual/palatino dos implantes.
|
117 |
Caracterização da interface entre cilindros pré-fabricados para prótese sobre implante e ligas fundidas de CoCrOzkomur, Ahmet January 2013 (has links)
Made available in DSpace on 2014-08-12T02:02:44Z (GMT). No. of bitstreams: 1
000460170-Texto+Parcial-0.pdf: 509347 bytes, checksum: 29dfc11c712477cbb23fef987bdd59f9 (MD5)
Previous issue date: 2013 / Purpose: The purpose of this study was to evaluate the metallurgical interfacial compatibility between CoCr dental casting alloys and a prefabricated CoCr dental implant cast-to-cylinder and the possible effects of porcelain firing cycles on this interface. Materials and methods: A cobalt-chromium base metal alloy was cast to the prefabricated CoCr implant cylinder. The specimens were cross-sectioned longitudinally and randomly divided into as-cast and heat-treated groups. After surface preparations, microstructures of the specimens were evaluated by optical and scanning electron microscopy. Elemental composition of the as-received prefabricated implant cylinders and diffusion characteristics of the cast interfacial regions were determined by Energy Dispersive X-Ray Spectroscopy. Vickers hardness values were defined across the interface as well as for the as-received implant cylinders. For statistical evaluation of hardness values ANOVA multivariate analysis and Bonferroni-adjusted t-tests were used. Results: CoCr cast alloy exhibited a solid solution matrix in a typical dendritic arrangement regardless of the specimen condition. No significant reaction regions and/or porosity were present in the interface. The microstructural aspect and interdiffusion indicated a metal-metal bond between CoCr implant cylinder and cast alloy. The mean hardness values demonstrated a significant raise across the interface from the wrought cylinder to the cast alloy for both conditions. Conclusions: CoCr casting alloy cast on to the prefabricated CoCr implant cylinders provided interfaces which appear to fulfill requirements of the established criteria. / O objetivo deste estudo foi avaliar a compatibilidade metalúrgica interfacial entre ligas de fundição de CoCr e um cilindro de sobrefundição de CoCr para prótese implanto-suportada e os possíveis efeitos dos ciclos de queima de porcelana nesta interface. Uma liga metálica de cobalto-cromo indicada para a técnica de sobrefundição foi fundida ao cilindro pré-fabricado de CoCr. As amostras compostas de cilindro e liga foram preparadas e posteriormente seccionadas longitudinalmente e divididas aleatoriamente em dois grupos: um termicamente tratado e outro sem tratamento. Após a preparação das superfícies, as microestruturas presentes na interface cilindro-liga fundida resultantes do processo de fundição foram avaliadas por microscopia eletrônica de varredura óptica. A composição química dos cilindros pré-fabricados como recebidos do fabricante e as características de difusão das regiões interfaciais fundidas foram determinadas por Espectroscopia por Energia Dispersiva de Raios-X. Os valores de dureza Vickers foram definidos para a interface cilindro-liga fundida assim como para os cilindros de implante como recebidos do fabricante. Resultados das análises indicaram uma matriz de solução sólida para a liga fundida de CoCr disposta em um arranjo tipicamente dendrítico independente do grupo analisado. Nenhuma região de reação negativa e/ou porosidade significativa estavam presentes na interface. O aspecto microestrutural e a interdifusão indicaram uma união estável entre o cilindro do implante de CoCr e a liga fundida. Os valores médios de dureza demonstraram, em ambas as condições, um aumento significante através da interface partindo do cilindro usinado em direção à liga fundida.A liga de fundição de CoCr fundida aos cilindros de implante pré-fabricados de CoCr forneceram interfaces que parecem preencher os requisitos dos critérios estabelecidos.
|
118 |
Avaliação do tântalo após tratamento de superfície com oxidação por plasma eletrolítico (PEO)Goularte, Marcelo Augusto Pinto Cardoso January 2014 (has links)
Made available in DSpace on 2015-03-13T02:01:27Z (GMT). No. of bitstreams: 1
000466188-Texto+Completo-0.pdf: 3447258 bytes, checksum: 508bf181d5a5fbbd572dfa7dfa3c800a (MD5)
Previous issue date: 2014 / Every year scientists and biomedical manufacturers bring to the market new biocompatible materials to use as prosthetic devices for the human body. Following that trend, oral implants manufactured with a Tantalum alloy started to be marketed in 2010 by a top orthopedic company. Although this metal has already been tested in dentistry and did not show satisfactory results from an experimental as well as a clinical standpoint in the past, the lack of a successful record was due to a poor comprehension of many important factors involved in the Osseointegration phenomenon. From the fixture design to the understanding of bone biology, the years of research have shown that survival and success in oral implantology is much more than the alloy can tell. And since bone histology has proved that Tantalum has a good healing response, we decided to subject this metal to a surface treatment similar to those regularly applied to Titanium fixtures. Using an especially PEO (Plasma Electrolytic Oxidation) devised protocol we have tried to evaluate the production of a surface oxidation and salt deposition on the metal surface and verify them using SEM (Scanning Electron Microscopy) and EDS (Energy Dispersive X-Ray Detector or EDX). For that matter, four groups were prepared: Group 1 – non-altered Tantalum metal sheets surfaces; Group 2 – Tantalum metal sheets exposed to PEO for 1 minute; Group 3 – Tantalum metal sheets exposed to PEO for 3 minutes; Group 4 – Tantalum metal sheets exposed to PEO for 5 minutes. The results were very satisfactory regarding salt deposition and surface modification and similar to those already seen on Titanium after anodization. / A cada ano, cientistas e empresas biomédicas trazem ao mercado novos materiais biocompatíveis para o uso em dispositivos protéticos para o corpo humano. Seguindo esse propósito, implantes dentários fabricados com uma liga de Tântalo foram introduzidos no mercado em 2010 por uma empresa líder em produtos ortopédicos. Embora esse metal já tenha sido utilizado sem muito sucesso tanto do ponto de vista experimental quanto clinico, na odontologia, a falta de uma resposta satisfatória foi devido à pouca compreensão de muitos fatores importantes envolvidos no fenômeno da Osseointegração. Do desenho do implante ao entendimento da biologia óssea, os anos de pesquisas mostraram que a sobrevivência e o sucesso dos implantes dentários são muito mais do que uma liga metálica possa representar. E já que a histologia óssea tem mostrado que o Tântalo tem uma boa resposta cicatricial, nós decidimos submeter esse metal a um tratamento superficial similar àqueles normalmente utilizados nos implantes de Titânio. Usando especialmente um protocolo desenvolvido para anodização PEO (Oxidação por Plasma Eletrolítico), nós tentamos avaliar a produção de oxidação superficial e deposição de sais sobre a superfície do metal e verificamos os resultados no MEV (Microscópio Eletrônico de Varredura) e o EDS (Espectroscopia por Dispersão de Energia Raio-X). Para a pesquisa, quatro grupos foram preparados: Grupo 1 – Lâminas de Tântalo não tratadas; Grupo 2 – Lâminas de Tântalo expostas ao PEO por 1 minuto; Grupo 3 - Lâminas de Tântalo expostas ao PEO por 3 minutos; Grupo 4 - Lâminas de Tântalo expostas ao PEO por 5 minutos. Os resultados foram muito satisfatórios ao considerar a deposição de sais e modificação superficial, muito similar àqueles já vistos no Titânio depois de exposto ao processo de anodização.
|
119 |
Protocolo de reabilitação bucal com inserção imediata de implante cone morse e prótese provisória unitária em alvéolos após exodontiaCauduro, Fernando Santos January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:09Z (GMT). No. of bitstreams: 2
000410373-0.pdf: 2008762 bytes, checksum: cda69846ce6e231d888b1e3a08fc8c22 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The present study describes a protocol for oral rehabilitation by means of osseointegrated implants with taper connection and installation of a provisional prosthesis, immediately after exodontia, and evaluates retrospectively, through the analysis of patient charts and complementary examinations, the result of the protocol instituted, for a postoperative follow-up period of up to five years. Fifty-seven consecutive patients, treated in the private clinic, were submitted to oral rehabilitation using a protocol for the insertion of an Ankylos® implant with a taper connection and the installation of a single provisional crown, immediately after exodontia. The protocol is characterized by its rapid and minimally traumatic surgical techniques, in which exodontia is performed without incision or mucoperiosteal detachment, only syndesmotomy, thereby dispensing with sutures; also, the immediate provisional crown effaces the alveolar opening, keeping the blood clot stable. The protocol does not recommend the use of grafts or other bone substitute biomaterials, nor the use of membranes for guided bone regeneration. The data on periimplantar tissue behavior with the application of the proposed protocol were collected and submitted to statistical analysis, where they were presented using tables, graphs, descriptive statistics (means and standard deviation) and statistical tests (Kolmogorov- Smirnov test, Fisher‟s exact test, analysis of variance-ANOVA, Tukey‟s test, and Kruskal- Wallis test) in the comparison or correlation between the variables related to the insertion protocol and to the postoperative clinical and radiographic characteristics. The success rate of the treatment was 98. 25% (56 implants), where there was a loss of one implant (1. 75%). The protocol appears to be reliable according to the clinical and radiographic results recorded in the patient charts. It is recommended to establish a surgical area with support in the palatine wall, mesial and distal, avoiding intentionally the vestibular wall and not following the orientation of the original alveolus. Implants of smaller diameter are utilized, provided that initial stability is obtained, facilitating the formation of the blood clot between the implant and vestibular alveolar wall, with the aim of filling it with neoformed bone. The taper connection implant allows the installation of the implant deeply (at least 3 mm below the bone crest), for the purpose of favoring and/or maintaining the bone neoformation at the top of the implant and consequent support for the soft tissues. In some cases, there is a discrete horizontal vestibular bone loss, resulting in the planning of the convexity of the vestibular alveolar wall, without interfering significantly with aesthetics. / O presente estudo descreve um protocolo de reabilitação bucal por meio de implantes osseointegráveis cone morse e instalação de prótese provisória, imediatamente após exodontia, e avalia retrospectivamente, por meio de análise de prontuários e exames complementares, o resultado do protocolo instituído, por um período de até cinco anos de acompanhamento pós-operatório. Cinqüenta e sete pacientes consecutivos, tratados em clínica privada, foram submetidos à reabilitação bucal com o protocolo de inserção de implante cone morse (Ankylos®) e instalação de coroa provisória unitária, imediatamente após exodontia. O protocolo caracteriza-se por técnicas cirúrgicas rápidas e minimamente traumáticas onde a exodontia é realizada sem incisão ou descolamento mucoperiostal, apenas sindesmotomia, dispensando suturas, e a coroa provisória imediata oblitera a abertura alveolar, mantendo o coágulo estável. O protocolo não preconiza enxertos ou outros biomateriais substitutos ósseos, bem como o uso de membranas para regeneração óssea guiada. Os dados sobre o comportamento tecidual periimplantar com a aplicação do protocolo proposto, foram coletados e submetidos à análise estatística, sendo apresentados através de tabelas, gráficos, estatísticas descritivas (média e desvio-padrão) e testes estatísticos (Kolmogorov-Smirnov, Exato de Fisher, Análise de Variância (ANOVA), Teste de Tukey e Teste de Kruskal-Wallis) na comparação ou correlação entre as variáveis relacionadas ao protocolo de inserção e às características clínicas e radiográficas pós-operatórias. O índice de sucesso do tratamento foi de 98,25% (56 implantes), havendo perda de um implante (1,75%).A partir da experiência clínica registrada nos prontuários, o protocolo sugere confiabilidade pelos resultados clínicos e radiográficos. Preconiza-se estabelecer uma loja cirúrgica com apoio na parede palatina, mesial e distal, afastando propositalmente da parede vestibular, não seguindo a orientação do alvéolo original, utilizando implantes com menor diâmetro, desde que obtida estabilidade inicial, possibilitando formação de coágulo sangüíneo entre o implante e a parede alveolar vestibular, visando o preenchimento com osso neoformado. O implante cone morse permite a instalação do implante profundamente (no mínimo 3mm abaixo da crista óssea), com intuito de favorecer e/ou manter a neoformação óssea sobre o espelho do implante e conseqüente suporte para os tecidos moles. Em alguns casos, ocorre uma discreta perda óssea vestibular horizontal, resultando em aplainamento da convexidade da parede alveolar vestibular, sem interferir significativamente na estética.
|
120 |
Efeito da reabsorção óssea na distribuição de tensões em overdenture implanto-muco-suportada: análise por elemento finito tridimensionalMariano, Luiz Oscar Honorato January 2008 (has links)
Made available in DSpace on 2011-12-27T14:14:12Z (GMT). No. of bitstreams: 2
000425580-0.pdf: 6525596 bytes, checksum: 2a348677d2212a5df654daf011e048d0 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study using 3D-finite element analysis aimed to evaluate the effect of bone resorption on the stress distribution generated by a static load on overdentures in cases of bone loss around implants and at the distal ridge. Tridimensional models were built from the images of a computerized tomography of a mandible and 3D laser digitalization of implants, abutments, mucosa, and complete denture. The geometric models of implants and abutments were mounted at the canine region to build the standard model (model 1 - absence of bone resorption). To build the experimental models the borders of the mandible geometric solid was modified to simulate bone loss around implants (model 2) and resorption of the distal ridge (model 3). The geometric models were converted into finite element models using a commercial software. The materials were considered homogeneous, isotropic, and linearly elastic. A 100 N load simulating a masticatory bolus was applied at the first molar region of each model. The von Mises stress distributions were analyzed and compared in selected points. The results showed that the bone resorption of the distal ridge associated with bone resorption around implants promoted higher stress concentration in dental implants, abutments, and marginal bone around implants. The highest stress concentration at marginal bone and implants occurred on the same side of the vertical load application for all models. / Este trabalho teve por objetivo avaliar, através da análise por elementos finitos com modelo tridimensional, o efeito da reabsorção óssea na distribuição de tensões geradas por uma carga estática simulada em prótese tipo overdenture, em situações de perda óssea ao redor dos implantes e reabsorção do rebordo posterior. Foram gerados modelos tridimensionais de uma mandíbula a partir das imagens de uma tomografia computadorizada helicoidal e dos intermediários protéticos, da prótese total, da placa resiliente e do implante através de um sistema de digitalização a laser em três planos. Os modelos geométricos dos implantes e intermediários protéticos foram montados na região dos caninos no modelo mandibular, constituindo o modelo padrão (modelo 1 - ausência de reabsorção óssea). Para a construção dos modelos experimentais, o contorno do modelo geométrico da mandíbula foi alterado para simular a perda óssea nos implantes (modelo 2) e a reabsorção do rebordo posterior associada à perda óssea marginal nos implantes (modelo 3). Os modelos geométricos foram inseridos em um programa comercial, no qual foi gerada a malha de elementos finitos. Os materiais foram considerados homogêneos, isotrópicos e linearmente elásticos. Uma carga de 100 N foi aplicada indiretamente, sobre uma simulação de bolo alimentar, na região de primeiro molar inferior direito em cada um dos três modelos. Foram analisadas e comparadas as distribuições de tensão de von Mises em pontos pré-determinados. Os resultados mostraram que a reabsorção óssea do rebordo posterior associada à perda óssea do osso periimplantar promoveu maior concentração de tensões nos implantes, nos componentes protéticos e no tecido ósseo marginal aos implantes. Houve maior concentração de tensões no tecido ósseo periimplantar e nos implantes localizados no mesmo lado do ponto de aplicação da carga vertical estática de 100 N, em todos os modelos analisados.
|
Page generated in 0.0895 seconds